Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38211896

RESUMEN

OBJECTIVE: Severe congenital aortic valve pathology in the growing patient remains a challenging clinical scenario. Bicuspidization of the diseased aortic valve has proven to be a promising repair technique with acceptable durability. However, most understanding of the procedure is empirical and retrospective. This work seeks to design the optimal gross morphology associated with surgical bicuspidization with simulations based on the hypothesis that modifications to the free edge length cause or relieve stenosis. METHODS: Model bicuspid valves were constructed with varying free edge lengths and gross morphology. Fluid-structure interaction simulations were conducted in a single patient-specific model geometry. The models were evaluated for primary targets of stenosis and regurgitation. Secondary targets were assessed and included qualitative hemodynamics, geometric height, effective height, orifice area, and billow. RESULTS: Stenosis decreased with increasing free edge length and was pronounced with free edge length less than or equal to 1.3 times the annular diameter d. With free edge length 1.5d or greater, no stenosis occurred. All models were free of regurgitation. Substantial billow occurred with free edge length 1.7d or greater. CONCLUSIONS: Free edge length 1.5d or greater was required to avoid aortic stenosis in simulations. Cases with free edge length 1.7d or greater showed excessive billow and other changes in gross morphology. Cases with free edge length 1.5d to 1.6d have a total free edge length approximately equal to the annular circumference and appeared optimal. These effects should be studied in vitro and in animal studies.

2.
ArXiv ; 2023 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-37808095

RESUMEN

OBJECTIVE: Severe congenital aortic valve pathology in the growing patient remains a challenging clinical scenario. Bicuspidization of the diseased aortic valve has proven to be a promising repair technique with acceptable durability. However, most understanding of the procedure is empirical and retrospective. This work seeks to design the optimal gross morphology associated with surgical bicuspidization with simulations, based on the hypothesis that modifications to the free edge length cause or relieve stenosis. METHODS: Model bicuspid valves were constructed with varying free edge lengths and gross morphology. Fluid-structure interaction simulations were conducted in a single patient-specific model geometry. The models were evaluated for primary targets of stenosis and regurgitation. Secondary targets were assessed and included qualitative hemodynamics, geometric height, effective height, orifice area and prolapse. RESULTS: Stenosis decreased with increasing free edge length and was pronounced with free edge length less than or equal to 1.3 times the annular diameter d. With free edge length 1.5d or greater, no stenosis occurred. All models were free of regurgitation. Substantial prolapse occurred with free edge length greater than or equal to 1.7d. CONCLUSIONS: Free edge length greater than or equal to 1.5d was required to avoid aortic stenosis in simulations. Cases with free edge length greater than or equal to 1.7d showed excessive prolapse and other changes in gross morphology. Cases with free edge length 1.5-1.6d have a total free edge length approximately equal to the annular circumference and appeared optimal. These effects should be studied in vitro and in animal studies.

3.
Eur J Cardiothorac Surg ; 56(3): 541-548, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-30897200

RESUMEN

OBJECTIVES: A double orifice of the left atrioventricular valve (LAVV) associated with atrioventricular septal defects (AVSD) can significantly complicate surgical repair. This study reports our experience of AVSD repair over 3 decades, with special attention to the zone of apposition (ZoA) of the main orifice, and presents a technique of hemivalve pericardial extension in specific situations. METHODS: We performed a retrospective study from 1987 to 2016 on 1067 patients with AVSD of whom 43 (4%) had a double orifice, plus 2 additional patients who required LAVV pericardial enlargement. Median age at repair was 1.3 years. Mean follow-up was 8.2 years (1 month-32 years). RESULTS: Associated abnormalities of the LAVV subvalvular apparatus were found in 7 patients (5 parachute LAVV and 2 absence of LAVV subvalvular apparatus). ZoA was noted in 4 patients (9%): partially closed in 15 (35%) and completely closed in 24 (56%). Four patients required, either at first repair or secondarily, a hemivalve enlargement using a pericardial patch without closure of the ZoA. The early mortality rate was 7% (n = 3), all before 2000. Two patients had unbalanced ventricles and the third had a single papillary muscle. There were no late deaths. Six patients (14%) required 7 reoperations (3 early and 4 late reoperations) for LAVV regurgitation and/or dysfunction, of whom 4 (9%) required mechanical LAVV replacement (all before 2000). Freedom from late LAVV reoperation was 97% at 1 year, 94% at 5 years and 87% at 10, 20 and 30 years. Unbalanced ventricles (P = 0.045), subvalvular abnormalities (P = 0.0037) and grade >2 LAVV postoperative regurgitation (P = 0.017) were identified as risk factors for LAVV reoperations. Freedom from LAVV mechanical valve replacement was 95% at 1 year, 90% at 5 years and 85% at 10, 20 and 30 years. An anomalous LAVV subvalvular apparatus was identified as a risk factor for mechanical valve replacement (P = 0.010). None of the patients who underwent LAVV pericardial extension had significant LAVV regurgitation at the last follow-up examination. CONCLUSIONS: Repair of AVSD and double orifice can be tricky. Preoperative LAVV regurgitation was not identified as an independent predictor of surgical outcome. LAVV hemivalve extension appears to be a useful and effective alternate surgical strategy when the ZoA cannot be closed.


Asunto(s)
Defectos de los Tabiques Cardíacos/patología , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Femenino , Defectos de los Tabiques Cardíacos/mortalidad , Defectos de los Tabiques Cardíacos/cirugía , Humanos , Lactante , Masculino , Reoperación , Estudios Retrospectivos , Válvula Tricúspide/anomalías , Válvula Tricúspide/cirugía
4.
Front Pediatr ; 7: 23, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30805324

RESUMEN

Background: 3D technology support is an emerging technology in the field of congenital heart diseases (CHD). The goals of 3D printings or models is mainly a better analysis of complex anatomies to optimize the surgical repair or intervention planning. Method: We performed a systematic review to evaluate the accuracy and reliability of CHD modelization and 3D printing, as well as the proof of concept of the benefit of 3D printing in planning interventions. Results: Correlation studies showed good results with anatomical measurements. This technique can therefore be considered reliable with the limit of the operator's subjectivity in modelizing the defect. In cases series, the benefits of the 3D technology have been shown for describing the vessels anatomy and guiding the surgical approach. For intra-cardiac complex anatomy, 3D models have been shown helpful for the planification of intracardiac repair. However, there is still lack of evidence based approach for the usefulness of 3D models in CHD in changing outcomes after surgery or interventional procedures due to the difficulty to design a prospective study with comprehensive and clinically meaningful end-points. Conclusion: 3D technology can be used to improve the understanding of anatomy of complex CHD and to guide surgical strategy. However, there is a need to design clinical studies to identify the place of this approach in the current clinical practice.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA