Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Tipo de estudio
Intervalo de año de publicación
1.
Brain ; 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39052924

RESUMEN

Brain-responsive neurostimulation is firmly ensconced among treatment options for drug-resistant focal epilepsy, but over a quarter of patients treated with the RNS System do not experience meaningful seizure reduction. Initial titration of RNS therapy is typically similar for all patients, raising the possibility that treatment response might be enhanced by consideration of patient-specific variables. Indeed, small, single-center studies have yielded preliminary evidence that RNS System effectiveness depends on the brain state during which stimulation is applied. The generalizability of these findings remains unclear, however, and it is unknown whether state-dependent effects of responsive neurostimulation are also stratified by location of the seizure onset zone where stimulation is delivered. We aimed to determine whether state-dependent effects of the RNS System are evident in the large, diverse, multi-center cohort of RNS System clinical trial participants and to test whether these effects differ between mesiotemporal and neocortical epilepsies. Eighty-one of 256 patients who were treated with the RNS System across 31 centers during clinical trials met criteria for inclusion in this retrospective study. Risk states were defined in relation to phases of daily and multi-day cycles of interictal epileptiform activity that are thought to determine seizure likelihood. We found that the probabilities of risk state transitions depended on the stimulation parameter being changed, the starting seizure risk state, and the stimulated brain region. Changes in two commonly adjusted stimulation parameters, charge density and stimulation frequency, produced opposite effects on risk state transitions depending on seizure localization. Greater variance in acute risk state transitions was explained by state-dependent responsive neurostimulation for bipolar stimulation for neocortical epilepsies and for monopolar stimulation for mesiotemporal epilepsies. Variability in effectiveness of RNS System therapy across individuals may relate, at least partly, to the fact that current treatment paradigms do not account fully for fluctuations in brain states or locations of simulation sites. State-dependence of electrical brain stimulation may inform development of next-generation closed-loop devices that can detect changes in brain state and deliver adaptive, localization-specific patterns of stimulation to maximize therapeutic effects.

2.
Nat Commun ; 14(1): 2997, 2023 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-37225710

RESUMEN

The neurophysiological mechanisms in the human amygdala that underlie post-traumatic stress disorder (PTSD) remain poorly understood. In a first-of-its-kind pilot study, we recorded intracranial electroencephalographic data longitudinally (over one year) in two male individuals with amygdala electrodes implanted for the management of treatment-resistant PTSD (TR-PTSD) under clinical trial NCT04152993. To determine electrophysiological signatures related to emotionally aversive and clinically relevant states (trial primary endpoint), we characterized neural activity during unpleasant portions of three separate paradigms (negative emotional image viewing, listening to recordings of participant-specific trauma-related memories, and at-home-periods of symptom exacerbation). We found selective increases in amygdala theta (5-9 Hz) bandpower across all three negative experiences. Subsequent use of elevations in low-frequency amygdala bandpower as a trigger for closed-loop neuromodulation led to significant reductions in TR-PTSD symptoms (trial secondary endpoint) following one year of treatment as well as reductions in aversive-related amygdala theta activity. Altogether, our findings provide early evidence that elevated amygdala theta activity across a range of negative-related behavioral states may be a promising target for future closed-loop neuromodulation therapies in PTSD.


Asunto(s)
Gastrópodos , Trastornos por Estrés Postraumático , Humanos , Masculino , Animales , Trastornos por Estrés Postraumático/terapia , Proyectos Piloto , Emociones , Afecto , Amígdala del Cerebelo
3.
Nature ; 589(7842): 420-425, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33361808

RESUMEN

Everyday tasks in social settings require humans to encode neural representations of not only their own spatial location, but also the location of other individuals within an environment. At present, the vast majority of what is known about neural representations of space for self and others stems from research in rodents and other non-human animals1-3. However, it is largely unknown how the human brain represents the location of others, and how aspects of human cognition may affect these location-encoding mechanisms. To address these questions, we examined individuals with chronically implanted electrodes while they carried out real-world spatial navigation and observation tasks. We report boundary-anchored neural representations in the medial temporal lobe that are modulated by one's own as well as another individual's spatial location. These representations depend on one's momentary cognitive state, and are strengthened when encoding of location is of higher behavioural relevance. Together, these results provide evidence for a common encoding mechanism in the human brain that represents the location of oneself and others in shared environments, and shed new light on the neural mechanisms that underlie spatial navigation and awareness of others in real-world scenarios.


Asunto(s)
Neuronas/fisiología , Percepción Espacial/fisiología , Navegación Espacial/fisiología , Adulto , Concienciación/fisiología , Relojes Biológicos , Cognición/fisiología , Electrodos Implantados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Lóbulo Temporal/fisiología
4.
Neuron ; 108(2): 322-334.e9, 2020 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-32946744

RESUMEN

Uncovering the neural mechanisms underlying human natural ambulatory behavior is a major challenge for neuroscience. Current commercially available implantable devices that allow for recording and stimulation of deep brain activity in humans can provide invaluable intrinsic brain signals but are not inherently designed for research and thus lack flexible control and integration with wearable sensors. We developed a mobile deep brain recording and stimulation (Mo-DBRS) platform that enables wireless and programmable intracranial electroencephalographic recording and electrical stimulation integrated and synchronized with virtual reality/augmented reality (VR/AR) and wearables capable of external measurements (e.g., motion capture, heart rate, skin conductance, respiration, eye tracking, and scalp EEG). When used in freely moving humans with implanted neural devices, this platform is adaptable to ecologically valid environments conducive to elucidating the neural mechanisms underlying naturalistic behaviors and to the development of viable therapies for neurologic and psychiatric disorders.


Asunto(s)
Encéfalo/fisiología , Estimulación Encefálica Profunda/instrumentación , Electroencefalografía/instrumentación , Desempeño Psicomotor , Telemetría/instrumentación , Dispositivos Electrónicos Vestibles , Realidad Aumentada , Electroencefalografía/métodos , Humanos , Procesamiento de Señales Asistido por Computador , Programas Informáticos , Realidad Virtual
5.
J Neurosci Methods ; 311: 408-417, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30267724

RESUMEN

BACKGROUND: Electrocorticography studies are typically conducted in patients undergoing video EEG monitoring, but these studies are subject to confounds such as the effects of pain, recent anesthesia, analgesics, drug changes, antibiotics, and implant effects. NEW METHOD: Techniques were developed to obtain electrocorticographic (ECoG) data from freely moving subjects performing navigational tasks using the RNS® System (NeuroPace, Inc., Mountain View, CA), a brain-responsive neurostimulation medical device used to treat focal onset epilepsy, and to align data from the RNS System with cognitive task events with high precision. These subjects had not had recent surgery, and were therefore not confounded by the perioperative variables that affect video EEG studies. RESULTS: Task synchronization using the synchronization marker technique provides a quantitative measure of clock uncertainty, and can align data to task events with less than 4 ms of uncertainty. Hippocampal ECoG activity was found to change immediately before an incorrect response to a math problem compared to hippocampal activity before a correct response. In addition, subjects were found to have variable but significant changes in theta band power in the hippocampus during navigation compared to when subjects were not navigating. We found that there is theta-gamma phase-amplitude coupling in the right hippocampus while subjects stand still during a navigation task. COMPARISON WITH EXISTING METHODS: An alignment technique described in this study improves the upper bound on task-ECoG alignment uncertainty from approximately 30 ms to under 4 ms. The RNS System is one of the first platforms capable of providing untethered ambulatory ECoG recording in humans, allowing for the study of real world instead of virtual navigation. Compared to intracranial video EEG studies, studies using the RNS System platform are not subject to confounds caused by the drugs and recent surgery inherent to the perioperative environment. Furthermore, these subjects provide the opportunity to record from the same electrodes over the course of many years. CONCLUSIONS: The RNS System enables us to study human navigation with unprecedented clarity. While RNS System patients have fewer electrodes implanted than video EEG patients, the lack of external artifact and confounds from recent surgery make this system a useful tool to further human electrophysiology research.


Asunto(s)
Encéfalo/fisiología , Electrocorticografía/instrumentación , Electrocorticografía/métodos , Neuroestimuladores Implantables , Procesos Mentales/fisiología , Adulto , Algoritmos , Electrodos Implantados , Hipocampo/fisiopatología , Humanos , Recuerdo Mental/fisiología , Persona de Mediana Edad , Pruebas Neuropsicológicas , Solución de Problemas/fisiología , Navegación Espacial/fisiología
6.
Curr Biol ; 27(24): 3743-3751.e3, 2017 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-29199073

RESUMEN

The theta rhythm-a slow (6-12 Hz) oscillatory component of the local field potential-plays a critical role in spatial navigation and memory by coordinating the activity of neuronal ensembles within the medial temporal lobe (MTL). Although theta has been extensively studied in freely moving rodents, its presence in humans has been elusive and primarily investigated in stationary subjects. Here we used a unique clinical opportunity to examine theta within the human MTL during untethered, real-world ambulatory movement. We recorded intracranial electroencephalographic activity from participants chronically implanted with the wireless NeuroPace responsive neurostimulator (RNS) and tracked their motion with sub-millimeter precision. Our data revealed that movement-related theta oscillations indeed exist in humans, such that theta power is significantly higher during movement than immobility. Unlike in rodents, however, theta occurs in short bouts, with average durations of ∼400 ms, which are more prevalent during fast versus slow movements. In a rare opportunity to study a congenitally blind participant, we found that both the prevalence and duration of theta bouts were increased relative to the sighted participants. These results provide critical support for conserved neurobiological characteristics of theta oscillations during ambulatory spatial navigation, while highlighting some fundamental differences across species in these oscillations between humans and rodents.


Asunto(s)
Lóbulo Temporal/fisiología , Ritmo Teta/fisiología , Caminata/fisiología , Adulto , Electrocorticografía , Femenino , Humanos , Neuroestimuladores Implantables , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA