Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
PLoS One ; 18(6): e0287381, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37390069

RESUMEN

The objective of this study was to provide an overarching description of the inter-subject variability of the equine femur and tibia morphology using statistical shape modeling. Fifteen femora and fourteen tibiae were used for building the femur and tibia statistical shape models, respectively. Geometric variations in each mode were explained by biometrics measured on ±3 standard deviation instances generated by the shape models. Approximately 95% of shape variations within the population were described by 6 and 3 modes in the femur and tibia shape models, respectively. In the femur shape model, the first mode of variation was scaling, followed by notable variation in the femoral mechanical-anatomical angle and femoral neck angle in mode 2. Orientation of the femoral trochlear tubercle and femoral version angle were described in mode 3 and mode 4, respectively. In the tibia shape model, the main mode of variation was also scaling. In mode 2 and mode 3, the angles of the coronal tibial plateau and the medial and lateral caudal tibial slope were described, showing the lateral caudal tibial slope angle being significantly larger than the medial. The presented femur and tibia shape models with quantified biometrics, such as femoral version angle and posterior tibial slope, could serve as a baseline for future investigations on correlation between the equine stifle morphology and joint disorders due to altered biomechanics, as well as facilitate the development of novel surgical treatment and implant design. By generating instances matching patient-specific femorotibial joint anatomy with radiographs, the shape model could assist virtual surgical planning and provide clinicians with opportunities to practice on 3D printed models.


Asunto(s)
Extremidad Inferior , Tibia , Animales , Caballos , Tibia/diagnóstico por imagen , Fémur/diagnóstico por imagen , Cuello Femoral , Fenómenos Biomecánicos
2.
Am J Vet Res ; 84(2)2023 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-36576802

RESUMEN

OBJECTIVE: This study aims to quantitatively characterize the passive kinematics of the healthy, soft tissue-intact equine stifle to establish an objective foundation for providing insights into the etiology of stifle disorders and developing a possible surgical treatment for stifle degenerative disease. ANIMALS: 5 whole-horse specimens. PROCEDURES: Reflective markers with intracortical bone pins and a motion capture system were used to investigate the stifle joint kinematics. Kinematics of 5 whole-horse specimens euthanized within 2 hours were calculated for internal/external rotation, adduction/abduction, and cranial/caudal translation of the medial and lateral femoral condyles and estimated joint contact centroids as functions of joint extension angle. RESULTS: From 41.7° to 121.6° (mean ± SD, range of motion: 107.5° ± 7.2°) of joint extension, 13° ± 3.7° of tibial external rotation and 6° ± 2.7° of adduction were observed. The lateral femoral condyle demonstrated significantly greater cranial translation than the medial during extension (23.7 mm ± 9.3 mm vs. 14.3 mm ± 7.0 mm, P = .01). No significant difference was found between the cranial/caudal translation of estimated joint contact centroids in the medial and lateral compartment (13.3 mm ± 7.7 mm vs. 16.4 mm ± 5.8 mm, P = .16). CLINICAL RELEVANCE: The findings share similarities with kinematics for human knees and sheep and dog stifles, suggesting it may be possible to translate what has been learned in human arthroplasty to treatment for equine stifles.


Asunto(s)
Caballos , Rodilla de Cuadrúpedos , Animales , Fenómenos Biomecánicos , Movimiento , Rango del Movimiento Articular , Rodilla de Cuadrúpedos/fisiología
3.
Front Vet Sci ; 8: 706046, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34746274

RESUMEN

The use of magnetic resonance imaging (MRI) has led to increased clinical and research applications using 3D segmentation and reconstructed volumetric data in musculoskeletal imaging. Lesions of the deep digital flexor tendon (DDFT) are a common pathology in horses undergoing MRI. Three-dimensional MRI reconstruction performed for volumetric tendon analysis in horses has not previously been documented. The aim of this proof-of-concept study was to evaluate the 3D segmentation of horses undergoing repeated MRI at several time points and to perform an analysis of the segmented DDFTs across time. MRI DICOM files were acquired from six horses undergoing repeated MRI examination of the foot for DDFT injury. Once segmented, volumetric tendon surface tessellation language (STL) files were created. Thickness and volumetric data were acquired for each tendon in addition to a tendon comparison across timepoints within each horse. Pearson correlation coefficients were calculated for comparison of MRI reports to computer analysis. There was a significant and positive correlation between MRI and medial record reports of clinical improvement or deterioration and computer analysis (r = 0.56, p = 0.01). The lower end range limit for tendon thickness varied between 0.16 and 1.74 mm. The upper end range limit for DDFT thickness varied between 4.6 and 23.6 mm. During tendon part comparison, changes in DDFT were reported between -3.0 and + 14.3 mm. Changes in DDFT size were non-uniform and demonstrated fluctuations throughout the tendon. The study was successful in establishing the volumetric appearance and thickness of the DDFT as it courses in the foot and tracking this over time. We encountered difficulties in accurate segmentation of the distal insertion of the DDFT as it blends with the distal phalanx. The data demonstrated that the DDFT can be segmented and volumetric studies based on size and shape can be performed using an in silico approach.