RESUMEN
The use of computational tools for the development of technologies in fields such as medicine and engineering has facilitated the process of designing new components and devices for these areas. In this work, two proposals focused on a hollow microneedle array (MNA) for the administration of an analgesic drug are shown and evaluated by means of a computational fluid dynamics (CFD) simulation distributed in three stages. In the first stage, the behavior of lidocaine through the MNA was evaluated as a workflow. Then, the possible entry of the drug into the organism, which was established as a porous aqueous medium, was modeled. Finally, a joint simulation was performed to understand the general behavior in the interaction between the outflow of an MNA and the body to which lidocaine is administered. The input parameters to the simulation were set at a velocity of 0.05 mâs-1, at a pressure of 2000 Pa, the dominant behavior was defined as laminar flow, and a resistive pressure at the inlet of 400 Pa. Our results indicate that the vertical flow exhibits a better fluid distribution across the MNAs and favorable infiltration behavior, representing better delivery of the analgesic to the skin capillaries.
RESUMEN
RESUMEN: Introducción: La utilización de instrumental piezoeléctrico en cirugía ortognática ha ido en aumento con el fin de minimizar el riesgo de daño a tejidos blandos en comparación al uso de sierra convencional. Sin embargo, aún existe incertidumbre respecto a las complicaciones asociadas a cada instrumental. Métodos: Realizamos una búsqueda en Epistemonikos, la mayor base de datos de revisiones sistemáticas en salud, la cual es mantenida mediante el cribado de múltiples fuentes de información, incluyendo MEDLINE, EMBASE, Cochrane, entre otras. Extrajimos los datos desde las revisiones identificadas, analizamos los datos de los estudios primarios, realizamos un meta análisis y preparamos una tabla de resumen de los resultados utilizando el método GRADE. Resultados y conclusiones: Identificamos cuatro revisiones sistemáticas que en conjunto incluyeron 10 estudios primarios, de los cuales, cuatro corresponden a ensayos aleatorizados. Concluimos que el uso de instrumental piezoeléctrico en comparación con la sierra convencional podría disminuir el riesgo de daño nervioso grave y disminuir el sangrado grave (>500 mL), pero la certeza de la evidencia es baja. Por otra parte, el uso de instrumental piezoeléctrico podría presentar poca o nula diferencia en el dolor postoperatorio, pero la certeza de la evidencia es baja. Finalmente no es posible establecer con claridad si el uso de instrumental piezoeléctrico disminuye la pérdida de sangre intraoperatoria (variable continua), la inflamación postoperatoria o el tiempo operatorio, ya que la certeza de la evidencia existente ha sido evaluada como muy baja.
ABSTRACT: Introduction: The use of piezoelectric bone surgery in orthognathic surgery has been increasing to minimize the risk of soft tissue damage compared to conventional saws. However, there is still uncertainty regarding the complications associated with each instrument. Methods: We searched in Epistemonikos, the largest database of systematic reviews in health, which is maintained by screening multiple information sources, including MEDLINE, EMBASE, Cochrane, among others. We extracted data from the systematic reviews, reanalyzed primary studies' data, conducted a meta-analysis and generated a summary of findings table using the GRADE approach. Results and conclusions: We identified four systematic reviews that included 10 primary studies, four of which corresponded to randomized trials. We conclude that the use of piezoelectric instrumentation compared to the conventional saw may reduce the risk of severe nerve damage and decrease severe bleeding (>500 mL), but the certainty of the evidence is low. On the other hand, the use of piezoelectric bone surgery may make little or no difference in postoperative pain, but the certainty of the evidence is low. Finally, we are uncertain whether piezoelectric bone surgery reduces intraoperative blood loss (continuous variable), postoperative inflammation, and operative time, as the certainty of the evidence has been assessed as very low.
Asunto(s)
Humanos , Osteotomía/métodos , Anomalías Maxilofaciales/cirugía , Cirugía Ortognática/métodos , Osteotomía/instrumentación , Cirugía Ortognática/instrumentación , PiezocirugíaRESUMEN
RESUMEN: Introducción: Tradicionalmente la osteotomía requerida en la exodoncia de terceros molares mandibulares incluidos o semi-incluidos ha sido realizada con instrumental manual o rotatorio. Con el advenimiento de la técnica ultrasónica de la cirugía piezoeléctrica, se hace necesario comparar la seguridad y efectividad de ambas técnicas. Métodos: Realizamos una búsqueda en Epistemonikos, la mayor base de datos de revisiones sistemáticas en salud, la cual es mantenida mediante el cribado de múltiples fuentes de información, incluyendo MEDLINE, EMBASE, Cochrane, entre otras. Extrajimos los datos desde las revisiones identificadas, analizamos los datos de los estudios primarios, realizamos un metanálisis y preparamos una tabla de resumen de los resultados utilizando el método GRADE. Resultados y conclusiones: Identificamos ocho revisiones sistemáticas que en conjunto incluyeron 22 estudios primarios, de los cuales 12 corresponden a ensayos clínicos aleatorizados. Concluimos que el uso de instrumental piezoeléctrico en comparación con el instrumental rotatorio convencional podría aumentar el tiempo quirúrgico y podría disminuir el dolor temprano y tardío, junto con el edema al día siete, pero la certeza de la evidencia es baja. Por otra parte, el uso de instrumental piezoeléctrico podría resultar en poca o nula diferencia en el desarrollo de alteraciones neurológicas postoperatorias ya que la certeza de la evidencia es baja. Además, el uso de piezoeléctrico probablemente resulte en poca o nula diferencia en la apertura bucal.
ABSTRACT: Introduction: Traditionally, osteotomy techniques required in exodontia of included or semi-included mandibular third molars has been performed with manual or rotary instruments. With the advent of the ultrasonic technique of piezoelectric surgery, it is necessary to evaluate the effectiveness and safety of both osteotomy techniques. Methods: We searched in Epistemonikos, the largest database of systematic reviews in health, which is maintained by screening multiple information sources, including MEDLINE, EMBASE, Cochrane, among others. We extracted data from the systematic reviews, reanalyzed primary studies' data, conducted a meta-analysis and generated a summary of findings table using the GRADE approach. Results and conclusions: We identified eight systematic reviews that together included 22 primary studies overall, of which 12 were randomized trials. We conclude that the use of piezoelectric surgery compared with conventional rotary instruments may increase operative time and reduce early and late pain, along with edema at day seven, but the certainty of the evidence is low. On the other hand, the use of piezoelectric instrumentation may result in little or no difference in the development of postoperative neurologic disturbances as the certainty of the evidence is low. Also, piezoelectric use probably makes little or no differences in mouth opening.
Asunto(s)
Humanos , Extracción Dental/instrumentación , Instrumentos Dentales , Tercer Molar/cirugía , Osteotomía/instrumentación , PiezocirugíaRESUMEN
RESUMEN: Introducción: Los abordajes transconjuntival preseptal y subciliar han sido ampliamente utilizados para el manejo quirúrgico de las fracturas orbitarias. Sin embargo, aún existe incertidumbre sobre las complicaciones asociadas a cada uno de estos abordajes. Métodos: Realizamos una búsqueda en Epistemonikos, la mayor base de datos de revisiones sistemáticas en salud, la cual es mantenida mediante el cribado de múltiples fuentes de información, incluyendo MEDLINE, EMBASE, Cochrane, entre otras. Extrajimos los datos desde las revisiones identificadas, analizamos los datos de los estudios primarios. Realizamos un metanálisis y preparamos una tabla de resumen de los resultados utilizando el método GRADE. Resultados y conclusiones: Identificamos seis revisiones sistemáticas que en conjunto incluyeron 21 estudios primarios, de los cuales cuatro corresponden a ensayos aleatorizados. Concluimos que el abordaje transconjuntival preseptal podría disminuir tanto la incidencia de ectropión como de un resultado estético insatisfactorio, pero la certeza de la evidencia es baja. Además, este abordaje probablemente disminuye el riesgo de complicaciones intra y postoperatorias, tales como diplopía, parestesia transitoria, equimosis, exposición escleral, laceración del plato tarsal y laceración palpebral inferior. Por otro lado, el abordaje transconjuntival podría aumentar el riesgo de entropión, pero la certeza de la evidencia también es baja.
ABSTRACT: Introduction: The preseptal transconjunctival and subciliary approach have been widely used for the surgical management of orbital fractures. However, there is still uncertainty about the complications associated with each of these approaches. Methods: We searched in Epistemonikos, the largest database of systematic reviews in health, which is maintained by screening multiple information sources, including MEDLINE, EMBASE, Cochrane, among others. We extracted data from the systematic reviews, reanalyzed data of primary studies, conducted a meta-analysis and generated a summary of findings table using the GRADE approach. Results and conclusions: We identified six systematic reviews that included 21 primary studies, four of which correspond to randomized trials. We conclude that the preseptal transconjunctival approach could decrease the incidence of ectropion and an unsatisfactory aesthetic result, but the certainty of the evidence is low. Furthermore, this approach probably decreases the risk of intra and postoperative complications, such as diplopia, transient paresthesia, ecchymosis, scleral show, tarsal plate laceration and lower palpebral laceration. On the other hand, the transconjunctival approach could increase the risk of entropion, but the certainty of the evidence is also low.
Asunto(s)
Humanos , Fracturas Orbitales , Fracturas Óseas , Enfoque GRADERESUMEN
The efficacy of a proactive dengue surveillance system to predict epidemics depends on the laboratory diagnostic capacity for an early detection of virus circulation. This study shows the results of the dengue virologic and serologic surveillance accomplished in Aragua State (Venezuela) from October 1997 to December 1998. Five hundred and forty seven sera from suspected dengue patients were tested using the techniques of Virus Isolation and Immunofluorescence Serotyping (VIIS), Reverse Transcriptase-Polymerase Chain Reaction (RT-PCR), Anti-dengue IgM Capture Enzyme Immunoassay (MAC-ELISA) and Haemagglutination Inhibition test (HI). Of the tested sera, 97.4% resulted positive to at least one technique; of these, 60.4% were classified as confirmed cases (virologically positives) and 39.6% as probable cases (virologically negatives/serologically positives). Though the majority of positive cases occurred during the 1997 and 1998 epidemic periods, the gradual increase of the seropositive rates between both periods suggested the incoming 1998 outbreak. Den-1 (51.2%), Den-2 (37.9%) and Den-4 (10.6%) infected patients were detected as well as one dual infection of Den-2 and Den-4 (0.3%). Dengue hyperendemicity (co-circulation of Den-1, Den-2 and Den-4) in Aragua State was confirmed together with the detection of few cases (6.5%) of Dengue Hemorrhagic Fever/Dengue Shock Syndrome cases (HF/DSS); 38.1% of these cases occurred in patients with secondary infections. The high percentage (85.7%) of DHF/DSS cases infected by Den-2 virus supports the reported virulence of this serotype.
Asunto(s)
Virus del Dengue/aislamiento & purificación , Dengue/diagnóstico , Dengue/sangre , Dengue/epidemiología , Virus del Dengue/clasificación , Virus del Dengue/genética , Ensayo de Inmunoadsorción Enzimática , Hemaglutininas Virales/sangre , Humanos , Inmunoglobulina M/sangre , ARN Viral/análisis , ARN Viral/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Pruebas Serológicas , Serotipificación , Dengue Grave/sangre , Dengue Grave/diagnóstico , Dengue Grave/epidemiología , Venezuela/epidemiologíaRESUMEN
La eficacia de un sistema de vigilancia epidemiológica proactivo para predecir epidemias de dengue de la capacidad del laboratorio para detectar tempranamente la circulación viral. Este estudio muestra los resultados de la vigilancia virológica del dengue, realizada en el estado Aragua (Venezuela) desde octubre 1997 hasta diciembre 1998. Se evluaron 547 sueros de pacientes sospechosos de dengue mediante las técnicas de aislamiento viral y serotipicación por inmunofluorescencia (AVSI), reacción en cadena de la polimerasa con transcriptasa inversa (RT-PCR), inmunoensayo enzimático de captura de IgM anti-dengue (MAC-ELISA) e inhibición de la hemaglutinación (IHA). De los sueros examinados, 97,4 por ciento resultaron positivos a por lo menos una técnica; de estos, 60,4 por ciento fueron clasificados como casos confirmados (virológicamente positivos) y 39,6 por ciento como casos probables (virológicamente negativos, serológicamente positivos). Aunque la gran mayoría de los casos positivos ocurrieron en los períodos epidémicos de 1997 y 1998, el incremento paulatino de las tasas de serotipos entre ambos períodos sugería la llegada de la epidemia de 1998. Se detectaron pacientes infectados con virus Den-1 (51,2 por ciento), Den-2 (37,9 por ciento), Den-4 (10,6 por ciento), y una infección mixta por Den-2 y Den-4 (0,3 por ciento). Se confirma la hiperdemicidad del dengue (co-circulación de Den-1, Den-2 y Den-4) en el estado Aragua, conjuntamente con la detección de pocos pasos (6,5 por ciento) de fiebre hemorrágica de dengue/síndrome de choque por dengue (FHD/SCD); 38,1 por ciento de estos casos ocurrieron en pacientes con infecciones secundarias. El alto porcentaje (85,7 por ciento) de casos de FHD/SCD infectados con el virus Den-2 apoya la reportada virulencia de este serotipo