Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Sci Rep ; 14(1): 15803, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38982100

RESUMEN

We report the photon (PL), electron (CL) and X-ray (XEL) induced luminescence characteristics of high aspect ratio ultra-long (~ 50 µm) ZnO nanorods (NRs) and discuss the potential for fast X-ray detection based on the consistent and efficient visible emission (~ 580 nm) from ZnO NRs. Nanostructured ZnO scintillators were rearranged to form a vertically well-aligned NR design in order to help light absorption and coupling resulting in luminescent and fast scintillation properties. The design of the nanorod array combines the key advantages of a low-cost growth technique together with environmentally friendly and widely available materials. A low temperature hydrothermal method was adopted to grow ZnO NRs in one cycle growth and their structural, optical and X-ray scintillation properties were investigated. The relatively short (~ 10 µm) ZnO NRs emitting in the near-band-edge region were found to be almost insensitive to X-rays. On the other hand, the higher XEL response of long ZnO NRs, which is a key parameter for evaluation of materials to be used as scintillators for high quality X-ray detection and imaging, along with a decay time response in the order of ns confirmed promising scintillation properties for fast and high-resolution X-ray detector applications.

2.
Radiat Environ Biophys ; 63(1): 143-164, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38310599

RESUMEN

The materials which compose the ICRP Voxel phantoms used in the computation of conversion coefficients involve neutron interaction cross-sections that have resonances at specific energies. Depending on the energy bin structure used in the computations, these cross-section resonances may occur at energies that fall between energies at which dose coefficients are computed, thus their effects may not be completely accounted for in the reported coefficients. In the present study, a highly refined energy grid that closely follows the resonance structure in the phantom material cross-sections was identified and used to calculate dose coefficients. Both the equivalent organ/tissue doses for male and female voxel phantoms were computed as well as their summation to obtain the effective dose coefficients. The used refined energy grid tracks very closely the cross-sections in the vicinity of the resonances. The resulting refined energy grid coefficients are compared to coefficients for the coarser energy grid used in ICRP Publication 116. Additionally, reference spectra have been folded with both the fine and coarse sets of conversion coefficients. The resulting total effective doses for these reference spectra are used to assess the adequacy of the dose coefficients calculated on the original ICRP 116 energy grid. The dose coefficients were similarly computed for the local skin dose on the trunk of the body using the ICRU Report 95 phantom. The overall impact of the resonances on the organ/tissue equivalent dose, the effective dose, and the local skin dose are presented and discussed. In general, it was found that resonances can impact neutron dose coefficients, but in most cases the wide range of neutron energies encountered minimized this effect. The impact of resonances was further limited when computing effective dose due to organ/tissue summing and sex-averaging. For the neutron fields studied here, the impact was below 5%.


Asunto(s)
Proteínas Adaptadoras Transductoras de Señales , Neutrones , Masculino , Femenino , Humanos , Dosis de Radiación , Fantasmas de Imagen , Radiometría/métodos , Método de Montecarlo
3.
Materials (Basel) ; 16(20)2023 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-37895699

RESUMEN

ZnO nanoarrays were grown via a low-temperature hydrothermal method. Solutions, each with different additive combinations, were prepared and evaluated. The effects of the additives involved in the growth procedure, i.e., ammonium hydroxide and sodium citrate, were studied in terms of the morphological, optical and scintillation properties of the ZnO nanostructures. Measurement of the nanorod (NR) length, corresponding photoluminescence (PL) and scintillation spectra and their dependence on the additives present in the solution are discussed. ZnO NRs grown on a silica substrate, whose UV transmission was found to be better than glass, showed high-quality structural and optical properties. It was found that the addition of sodium citrate significantly reduced defects and correspondingly increased the intrinsic near-band-edge (NBE) UV emission intensity at ~380 nm. To obtain high-quality nanostructures, samples were annealed in a 10% H2 + 90% N2 atmosphere. The anneal in the forming gas atmosphere enhanced the emission of the UV peak by reducing defects in the nanostructure. NRs are highly tapered towards the end of the structure. The tapering process was monitored using time growth studies, and its effect on PL and reflectance spectra are discussed. A good alpha particle response was obtained for the grown ZnO NRs, confirming its potential to be used as an alpha particle scintillator. After optimizing the reaction parameters, it was concluded that when ammonium hydroxide and sodium citrate were used, vertically well-aligned and long ZnO nanoarrays with highly improved optical and scintillation properties were obtained.

4.
Radiat Prot Dosimetry ; 199(12): 1310-1323, 2023 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-37345708

RESUMEN

During the early response to large-scale radioactive contamination events, people who are potentially affected need to be screened for radioactive contamination and public health staff need to triage individuals who may need immediate decontamination. This is typically done by screening individuals for external contamination using ionising radiation detection equipment. In this study, spatially and temporally dependent isotopic compositions from a simulated nuclear detonation and Monte Carlo methods were used to relate contamination activity levels to the measurable radiation levels at select distances away from an individual with whole-body contamination. Radionuclide-specific air kerma rate coefficients and Geiger-Mueller instrument response coefficients at five select distances from contaminated individuals are presented for 662 radionuclides. Temporally and spatially dependent incident-specific coefficients are presented for a hypothetical surface detonation of a 235U-fueled device.


Asunto(s)
Monitoreo de Radiación , Uranio , Humanos , Radioisótopos/análisis , Triaje/métodos , Dosis de Radiación
5.
Radiat Environ Biophys ; 62(3): 317-329, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37296237

RESUMEN

A significant source of information on radiation-induced biological effects following in-utero irradiation stems from studies of atomic bomb survivors who were pregnant at the time of exposure in Hiroshima, and to a lesser extent, from survivors in Nagasaki. Dose estimates to the developing fetus for these survivors have been assigned in prior dosimetry systems of the Radiation Effects Research Foundation as the dose to the uterine wall within the non-pregnant adult stylized phantom, originally designed for the dosimetry system DS86 and then carried forward in DS02. In a prior study, a new J45 (Japanese 1945) series of high-resolution phantoms of the adult pregnant female at 8 weeks, 15 weeks, 25 weeks, and 38-weeks post-conception was presented. Fetal and maternal organ doses were estimated by computationally exposing the pregnant female phantom series to DS02 free-in-air cumulative photon and neutron fluences at three distances from the hypocenter at both Hiroshima and Nagasaki under idealized frontal (AP) and isotropic (ISO) particle incidence. In this present study, this work was extended using realistic angular fluences (480 directions) from the DS02 system for seven radiation source terms, nine different radiation dose components, and five shielding conditions. In addition, to explore the effects of fetal position within the womb, four new phantoms were created and the same irradiation scenarios were performed. General findings are that the current DS02 fetal dose surrogate overestimates values of fetal organ dose seen in the J45 phantoms towards the cranial end of the fetus, especially in the later stages of pregnancy. For example, for in-open exposures at 1000 m in Hiroshima, the ratio of J45 fetal brain dose to DS02 uterine wall dose is 0.90, 0.82, and 0.70 at 15 weeks, 25 weeks, and 38-weeks, respectively, for total gamma exposures, and are 0.64, 0.44, and 0.37 at these same gestational ages for total neutron exposures. For organs in the abdominal and pelvic regions of the fetus, dose gradients across gestational age flatten and later reverse, so that DS02 fetal dosimetry begins to underestimate values of fetal organ dose as seen in the J45 phantoms. For example, for the same exposure scenario, the ratios of J45 fetal kidney dose to DS02 uterine wall dose are about 1.09 from 15 to 38 weeks for total gamma dose, and are 1.30, 1.56, and 1.75 at 15 weeks, 25 weeks, and 38 weeks, respectively, for the total neutron dose. Results using the new fetal positioning phantoms show this trend reversing for a head-up, breach fetal position. This work supports previous findings that the J45 pregnant female phantom series offers significant opportunities for gestational age-dependent assessment of fetal organ dose without the need to invoke the uterine wall as a fetal organ surrogate.


Asunto(s)
Guerra Nuclear , Traumatismos por Radiación , Adulto , Femenino , Humanos , Embarazo , Supervivientes a la Bomba Atómica , Radiometría/métodos , Sobrevivientes , Feto , Japón
6.
Health Phys ; 125(4): 245-259, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37358430

RESUMEN

ABSTRACT: Organ dosimetry data of the atomic bomb survivors and the resulting cancer risk models derived from these data are currently assessed within the DS02 dosimetry system developed through the Joint US-Japan Dosimetry Working Group. In DS02, the anatomical survivor models are limited to three hermaphroditic stylized phantoms-an adult (55 kg), a child (19.8 kg), and an infant (9.7 kg)-that were originally designed for the preceding DS86 dosimetry system. As such, organ doses needed for assessment of in-utero cancer risks to the fetus have continued to rely upon the use of the uterine wall in the adult non-pregnant stylized phantom as the dose surrogate for all fetal organs regardless of gestational age. To address these limitations, the Radiation Effects Research Foundation (RERF) Working Group on Organ Dose (WGOD) has established the J45 (Japan 1945) series of high-resolution voxel phantoms, which were derived from the UF/NCI series of hybrid phantoms and scaled to match mid-1940s Japanese body morphometries. The series includes male and female phantoms-newborn to adult-and four pregnant female phantoms at gestational ages of 8, 15, 25, and 38 wk post-conception. In previous studies, we have reported organ dose differences between those reported by the DS02 system and those computed by the WGOD using 3D Monte Carlo radiation transport simulations of atomic bomb gamma-ray and neutron fields for the J45 phantoms series in their traditional "standing" posture, with some variations in their facing direction relative to the bomb hypocenter. In this present study, we present the J45 pregnant female phantoms in both a "kneeling" and "lying" posture and assess the dosimetric impact of these more anatomically realistic survivor models in comparison to current organ doses given by the DS02 system. For the kneeling phantoms facing the bomb hypocenter, organ doses from bomb source photon spectra were shown to be overestimated by the DS02 system by up to a factor of 1.45 for certain fetal organs and up to a factor of 1.17 for maternal organs. For lying phantoms with their feet in the direction of the hypocenter, fetal organ doses from bomb source photon spectra were underestimated by the DS02 system by factors as low as 0.77, while maternal organ doses were overestimated by up to a factor of 1.38. Organs doses from neutron contributions to the radiation fields exhibited an increasing overestimation by the DS02 stylized phantoms as gestational age increased. These discrepancies are most evident in fetal organs that are more posterior within the mother's womb, such as the fetal brain. Further analysis revealed that comparison of these postures to the original standing posture indicate significant dose differences for both maternal and fetal organ doses depending on the type of irradiation. Results from this study highlight the degree to which the existing DS02 system can differ from organ dosimetry based upon 3D radiation transport simulations using more anatomically realistic models of those survivors exposed during pregnancy.


Asunto(s)
Supervivientes a la Bomba Atómica , Traumatismos por Radiación , Recién Nacido , Niño , Adulto , Embarazo , Humanos , Masculino , Femenino , Radiometría/métodos , Feto/efectos de la radiación , Postura
7.
Biomed Phys Eng Express ; 9(1)2022 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-36562506

RESUMEN

Monte Carlo (MC) methods are considered the gold-standard approach to dose estimation for normal tissues outside the treatment field (out-of-field) in proton therapy. However, the physics of secondary particle production from high-energy protons are uncertain, particularly for secondary neutrons, due to challenges in performing accurate measurements. Instead, various physics models have been developed over the years to reenact these high-energy interactions based on theory. It should thus be acknowledged that MC users must currently accept some unknown uncertainties in out-of-field dose estimates. In the present study, we compared three MC codes (MCNP6, PHITS, and TOPAS) and their available physics models to investigate the variation in out-of-field normal tissue dosimetry for pencil beam scanning proton therapy patients. Total yield and double-differential (energy and angle) production of two major secondary particles, neutrons and gammas, were determined through irradiation of a water phantom at six proton energies (80, 90, 100, 110, 150, and 200 MeV). Out-of-field normal tissue doses were estimated for intracranial irradiations of 1-, 5-, and 15-year-old patients using whole-body computational phantoms. Notably, the total dose estimates for each out-of-field organ varied by approximately 25% across the three codes, independent of its distance from the treatment volume. Dose discrepancies amongst the codes were linked to the utilized physics model, which impacts the characteristics of the secondary radiation field. Using developer-recommended physics, TOPAS produced both the highest neutron and gamma doses to all out-of-field organs from all examined conditions; this was linked to its highest yields of secondary particles and second hardest energy spectra. Subsequent results when using other physics models found reduced yields and energies, resulting in lower dose estimates. Neutron dose estimates were the most impacted by physics model choice, and thus the variation in out-of-field dose estimates may be even larger than 25% when considering biological effectiveness.


Asunto(s)
Terapia de Protones , Humanos , Terapia de Protones/métodos , Radiometría/métodos , Protones , Dosificación Radioterapéutica , Método de Montecarlo
8.
Life Sci Space Res (Amst) ; 35: 163-169, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36336362

RESUMEN

Implementation of a systematic program for galactic cosmic radiation (GCR) countermeasure discovery will require convenient access to ground-based space radiation analogs. The current gold standard approach for GCR simulation is to use a particle accelerator for sequential irradiation with ion beams representing different GCR components. This has limitations, particularly for studies of non-acute responses, strategies that require robotic instrumentation, or implementation of complex in vitro models that are emerging as alternatives to animal experimentation. Here we explore theoretical and practical issues relating to a different approach to provide a high-LET radiation field for space radiation countermeasure discovery, based on use of compact portable sources to generate neutron-induced charged particles. We present modeling studies showing that DD and DT neutron generators, as well as an AmBe radionuclide-based source, generate charged particles with a linear energy transfer (LET) distribution that, within a range of biological interest extending from about 10 to 200 keV/µm, resembles the LET distribution of reference GCR radiation fields experienced in a spacecraft or on the lunar surface. We also demonstrate the feasibility of using DD neutrons to induce 53BP1 DNA double-strand break repair foci in the HBEC3-KT line of human bronchial epithelial cells, which are widely used for studies of lung carcinogenesis. The neutron-induced foci are larger and more persistent than X ray-induced foci, consistent with the induction of complex, difficult-to-repair DNA damage characteristic of exposure to high-LET (>10 keV/µm) radiation. We discuss limitations of the neutron approach, including low fluence in the low LET range (<10 keV/µm) and the absence of certain long-range features of high charge and energy particle tracks. We present a concept for integration of a compact portable source with a multiplex microfluidic in vitro culture system, and we discuss a pathway for further validation of the use of compact portable sources for countermeasure discovery.


Asunto(s)
Radiación Cósmica , Animales , Humanos , Transferencia Lineal de Energía , Radiación Ionizante , Reparación del ADN , Daño del ADN
9.
Health Phys ; 123(4): 278-286, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35776943

RESUMEN

ABSTRACT: Specific absorbed fractions (SAFs) are key components in the workflow of internal exposure assessment following the intake of a radionuclide, allowing quick conversion of particle energy released in a source region to the expected absorbed dose in target regions throughout the body. For data completeness, SAFs for spontaneous fission neutron emitters are currently needed for the recently adopted ICRP reference pediatric voxel phantom series. With 77 source regions within each reference individual and 28 radionuclides decaying via spontaneous fission, full Monte Carlo simulation requires significant computation time. In order to reduce this burden, a novel method for neutron SAF estimation was undertaken. The Monte Carlo N-Particle version 6.1 (MCNP6) simulation package was chosen to simulate the 252 Cf Watt fission neutron spectrum originating from 15 source regions in each phantom; dose estimation within 41 target tissues allowed for assessment of the SAF value for each source-target pair. For the remaining source regions, chord length distributions were computed using MATLAB code to determine the separation between the source-target pairs within the pediatric phantom series. These distance distributions were used in conjunction with a 252 Cf neutron dose point kernel calculated in soft tissue, which was modified to account for the source region's depth from the surface of the body. Lastly, the 252 Cf SAF dataset was extended to the other 27 spontaneous fission neutron emitters based on differences in the Watt fission spectrum parameters of each radionuclide. This methodology has been shown to accurately estimate spontaneous fission neutron SAFs to within 20% of the Monte Carlo estimated value for most source-target pairs in the ICRP reference pediatric series.


Asunto(s)
Neutrones , Radioisótopos , Niño , Simulación por Computador , Humanos , Método de Montecarlo , Fantasmas de Imagen , Dosis de Radiación , Radiometría/métodos
10.
Radiat Environ Biophys ; 61(1): 73-86, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34718851

RESUMEN

The radiation exposure estimates for the atomic bomb survivors at Hiroshima and Nagasaki have evolved over the past several decades, reflecting a constant strive by the Radiation Effects Research Foundation (RERF) to provide thorough dosimetry to their cohort. Recently, a working group has introduced a new series of anatomical models, called the J45 phantom series, which improves upon those currently used at RERF through greater age resolution, sex distinction, anatomical realism, and organ dose availability. To evaluate the potential dosimetry improvements that would arise from their use in an RERF Dosimetry System, organ doses in the J45 series are evaluated here using environmental fluence data for 20 generalized survivor scenarios pulled directly from the current dosimetry system. The energy- and angle-dependent gamma and neutron fluences were converted to a source term for use in MCNP6, a modern Monte Carlo radiation transport code. Overall, the updated phantom series would be expected to provide dose improvements to several important organs, including the active marrow, colon, and stomach wall (up to 20, 20, and 15% impact on total dose, respectively). The impacts were especially significant for neutron dose estimates (up to a two-fold difference) and within organs which were unavailable in the previous phantom series. These impacts were consistent across the 20 scenarios and are potentially even greater when biological effectiveness of the neutron dose component is considered. The entirety of the dosimetry results for all organs are available as supplementary data, providing confident justification for potential future DS workflows utilizing the J45 phantom series.


Asunto(s)
Supervivientes a la Bomba Atómica , Radiometría , Adulto , Niño , Humanos , Japón , Método de Montecarlo , Fantasmas de Imagen , Radiometría/métodos
15.
Health Phys ; 119(6): 675-676, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33136688
18.
Radiat Res ; 194(4): 390-402, 2020 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-33045092

RESUMEN

Owing to recent advances in computational dosimetry tools, an update is warranted for the dosimetry system for atomic bomb survivors that was established by the Joint U.S.Japan Working Group on the Reassessment of Atomic Bomb Dosimetry in 2002 (DS02). The DS02 system, and its predecessor, DS86, at the Radiation Effects Research Foundation (RERF), are based on adjoint Monte Carlo particle transport simulations coupled with stylized computational human phantoms. In our previous studies, we developed the J45 series of computational voxel phantoms representative of 1945 Japanese adults, children and pregnant females. The dosimetric impact of replacing the DS02/DS86 stylized phantoms by the J45 phantom series was also discussed through computation of organ doses for several idealized exposure scenarios. In the current study, we investigated the possible impact of introducing not only the J45 phantom series but also various methodological upgrades to the DS02 dosimetry system. For this purpose, we calculated organ doses in adults for 12 representative exposure scenarios having realistic particle energy and angular fluence, using different combinations of phantoms and dose calculation methods. Those doses were compared with survivor organ doses given by the DS02 system. It was found that the anatomical improvement in the J45 phantom series is the most important factor leading to potential changes in survivor organ doses. However, methodological upgrades, such as replacement of the adjoint Monte Carlo simulation with kerma approximation by the forward Monte Carlo simulation with secondary electron transport, can also improve the accuracy of organ doses by up to several percent.In addition, this study established a series of response functions, which allows for the rapid conversion of the unidirectional quasi-monoenergetic photon and neutron fluences from the existing DS02 system to organ doses within the J45 adult phantoms. The overall impact of introducing the response functions in the dosimetry system is not so significant, less than 10% in most cases, except for organs in which the calculation method or definition was changed, e.g., colon and bone marrow. This system of response functions can be implemented within a revision to the DS02 dosimetry system and used for future updates to organ doses within the Life Span Study of the atomic bomb survivors.


Asunto(s)
Supervivientes a la Bomba Atómica , Simulación por Computador , Relación Dosis-Respuesta en la Radiación , Modelos Biológicos , Órganos en Riesgo/efectos de la radiación , Fantasmas de Imagen , Absorción de Radiación , Adulto , Femenino , Estudios de Seguimiento , Humanos , Japón , Masculino , Método de Montecarlo , Neutrones , Especificidad de Órganos , Fotones , Exposición a la Radiación , Traumatismos por Radiación , Protección Radiológica , Radiometría/instrumentación , Radiometría/métodos
19.
Sci Rep ; 9(1): 17551, 2019 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-31772191

RESUMEN

Neutron detection is crucial for particle physics experiments, nuclear power, space and international security. Solid state neutron detectors are of great interest due to their superior mechanical robustness, smaller size and lower voltage operation compared to gas detectors. Gallium nitride (GaN), a mature wide bandgap optoelectronic and electronic semiconductor, is attracting research interest for neutron detection due to its radiation hardness and thermal stability. This work investigated thermal neutron scintillation detectors composed of GaN thin films with and without conversion layers or rare-earth doping. Intrinsic GaN-based neutron scintillators are demonstrated via the intrinsic 14N(n, p) reaction, which has a small thermal neutron cross-section at low neutron energies, but is comparable to other reactions at high neutron energies (>1 MeV). Gamma discrimination is shown to be possible with pulse-height in intrinsic GaN-based scintillation detectors. Additionally, GaN-based scintillation detector with a 6LiF neutron conversion layer and Gd-doped GaN detector are compared with intrinsic GaN detectors. These results indicate GaN scintillator is a suitable candidate neutron detector in high-flux applications.

20.
Radiat Res ; 192(5): 538-561, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31469615

RESUMEN

An important cohort of the atomic bomb survivors are women who were pregnant when exposed to the photon and neutron fields at both Hiroshima and Nagasaki, as well as their children who were exposed in utero. Estimates of organ dose to the developing fetus allow for the development of dose-dependent and gestational age-dependent models of deterministic (e.g., organ malformation) and stochastic (e.g., leukemia) risk of in utero exposure. To date, both the 1986 and 2002 dosimetry systems at the Radiation Effects Research Foundation have utilized the uterine wall in the non-pregnant adult female as a dose surrogate for individual fetal organs and tissues. Here we present a new J45 (Japanese 1945) series of high-resolution phantoms of the adult pregnant female at 8-, 15-, 25- and 38-weeks post-conception. These models, which were derived from the University of Florida (UF) series of ICRP Publication 89 compliant reference phantoms, have been rescaled to approximate the pregnant mother using 1945 Japanese morphometry data. Fetal and maternal organ doses were estimated by computationally exposing the pregnant female phantom series to DS02 free-in-air photon and neutron fluences at three distances from the hypocenter at both Hiroshima and Nagasaki under frontal (AP) and isotropic (ISO) particle incidence. As for the fetal organ doses, our results indicate that the uterine wall of the non-pregnant female generally underestimates fetal organ dose within the pregnant female. The magnitude of these differences varies with both radiation type and irradiation geometry, with the smallest differences (5-7%) seen for ISO photon fields and the largest differences (20-30%) seen for AP neutron fields. Significant discrepancies were seen in fetal brain dose and its uterine wall surrogate, particularly for photon AP fields (ratio of uterine wall to brain dose varied from 0.9 to 1.3) and neutron AP fields (dose ratios from 0.75 to 2.0). As for the maternal organ doses, the use of organ doses in a non-pregnant female was shown, in general, to overestimate the corresponding organ doses in the pregnant female, with greater deviations seen at later stages of pregnancy (12-16% for AP photons and 44-53% for AP neutrons). The one exception was the uterine wall dose in pregnancy which was seen to be underestimated by that in the non-pregnant female phantom, particularly for ISO and AP neutron fields. These results demonstrate that the J45 pregnant female phantom series offers the opportunity for significant improvements in both fetal and maternal organ dose assessment within this unique cohort of the atomic bomb survivors.


Asunto(s)
Supervivientes a la Bomba Atómica , Feto/efectos de la radiación , Fantasmas de Imagen , Radiometría/métodos , Antropometría , Femenino , Humanos , Japón , Exposición Materna , Método de Montecarlo , Neutrones , Armas Nucleares , Fotones , Embarazo , Dosis de Radiación , Traumatismos por Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...