Acta Biomater ; 180: 46-60, 2024 May.
Article En | MEDLINE | ID: mdl-38615811

Blood-contacting medical devices often succumb to thrombosis, limiting their durability and safety in clinical applications. Thrombosis is fundamentally initiated by the nonspecific adsorption of proteins to the material surface, which is strongly governed by thermodynamic factors established by the nature of the interaction between the material surface, surrounding water molecules, and the protein itself. Along these lines, different surface materials (such as polymeric, metallic, ceramic, or composite) induce different entropic and enthalpic changes at the surface-protein interface, with material wettability significantly impacting this behavior. Consequently, protein adsorption on medical devices can be modulated by altering their wettability and surface energy. A plethora of polymeric coating modifications have been utilized for this purpose; hydrophobic modifications may promote or inhibit protein adsorption determined by van der Waals forces, while hydrophilic materials achieve this by mainly relying on hydrogen bonding, or unbalanced/balanced electrostatic interactions. This review offers a cohesive understanding of the thermodynamics governing these phenomena, to specifically aid in the design and selection of hemocompatible polymeric coatings for biomedical applications. STATEMENT OF SIGNIFICANCE: Blood-contacting medical devices often succumb to thrombosis, limiting their durability and safety in clinical applications. A plethora of polymeric coating modifications have been utilized for addressing this issue. This review offers a cohesive understanding of the thermodynamics governing these phenomena, to specifically aid in the design and selection of hemocompatible polymeric coatings for biomedical applications.


Coated Materials, Biocompatible , Polymers , Thermodynamics , Adsorption , Humans , Polymers/chemistry , Coated Materials, Biocompatible/chemistry , Surface Properties , Thrombosis/prevention & control , Animals , Blood Proteins/chemistry , Blood Proteins/metabolism
2.
JTCVS Open ; 15: 113-124, 2023 Sep.
Article En | MEDLINE | ID: mdl-37808055

Background: Polymeric heart valves (PHVs) may address the limitations of mechanical and tissue valves in the treatment of valvular heart disease. In this study, a bioinspired valve was designed, assessed in silico, and validated by an in vitro model to develop a valve with optimum function for pediatric applications. Methods: A bioinspired heart valve was created computationally with leaflet curvature derived from native valve anatomies. A valve diameter of 18 mm was chosen to approach sizes suitable for younger patients. Valves of different thicknesses were fabricated via dip-coating with siloxane-based polyurethane and tested in a pulse duplicator for their hydrodynamic function. The same valves were tested computationally using an arbitrary Lagrangian-Eulerian plus immersed solid approach, in which the fluid-structure interaction between the valves and fluid passing through them was studied and compared with experimental data. Results: Computational analysis showed that valves of 110 to 200 µm thickness had effective orifice areas (EOAs) of 1.20 to 1.30 cm2, with thinner valves exhibiting larger openings. In vitro tests demonstrated that PHVs of similar thickness had EOAs of 1.05 to 1.35 cm2 and regurgitant fractions (RFs) <7%. Valves with thinner leaflets exhibited optimal systolic performance, whereas thicker valves had lower RFs. Conclusions: Bioinspired PHVs demonstrated good hydrodynamic performance that exceeded ISO 5840-2 standards. Both methods of analysis showed similar correlations between leaflet thickness and valve systolic function. Further development of this PHV may lead to enhanced durability and thus a more reliable heart valve replacement than contemporary options.

...