Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Exp Toxicol Pathol ; 69(6): 359-365, 2017 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-28262483

RESUMEN

The exposure of cellular based systems cultivated on microporous membranes at the air-liquid interface (ALI) has been accepted as an appropriate approach to simulate the exposure of cells of the respiratory tract to native airborne substances. The efficiency of such an exposure procedure with regard to stability and reproducibility depends on the optimal design at the interface between the cellular test system and the exposure technique. The actual exposure systems favor the dynamic guidance of the airborne substances to the surface of the cells in specially designed exposure devices. Two module types, based on a linear or radial feed of the test atmosphere to the test system, were used for these studies. In our technical history, the development started with the linear designed version, the CULTEX® glass modules, fulfilling basic requirements for running ALI exposure studies (Mohr and Durst, 2005). The instability in the distribution of different atmospheres to the cells caused us to create a new exposure module, characterized by a stable and reproducible radial guidance of the aerosol to the cells. The outcome was the CULTEX® RFS (Mohr et al., 2010). In this study, we describe the differences between the two systems with regard to particle distribution and deposition clarifying the advantages and disadvantages of a radial to a linear aerosol distribution concept.


Asunto(s)
Aerosoles/toxicidad , Técnicas de Cultivo de Célula/métodos , Técnicas In Vitro/instrumentación , Técnicas In Vitro/métodos , Animales , Diseño de Equipo , Humanos , Exposición por Inhalación
2.
Biomed Res Int ; 2013: 734137, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23509768

RESUMEN

The EU Regulation on Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) demands the implementation of alternative methods for analyzing the hazardous effects of chemicals including particulate formulations. In the field of inhalation toxicology, a variety of in vitro models have been developed for such studies. To simulate the in vivo situation, an adequate exposure device is necessary for the direct exposure of cultivated lung cells at the air-liquid interface (ALI). The CULTEX RFS fulfills these requirements and has been optimized for the exposure of cells to atomized suspensions, gases, and volatile compounds as well as micro- and nanosized particles. This study provides information on the construction and functional aspects of the exposure device. By using the Computational Fluid Dynamics (CFD) analysis, the technical design was optimized to realize a stable, reproducible, and homogeneous deposition of particles. The efficiency of the exposure procedure is demonstrated by exposing A549 cells dose dependently to lactose monohydrate, copper(II) sulfate, copper(II) oxide, and micro- and nanoparticles. All copper compounds induced cytotoxic effects, most pronounced for soluble copper(II) sulfate. Micro- and nanosized copper(II) oxide also showed a dose-dependent decrease in the cell viability, whereby the nanosized particles decreased the metabolic activity of the cells more severely.


Asunto(s)
Contaminantes Atmosféricos/toxicidad , Técnicas de Cultivo de Célula/métodos , Células Epiteliales/efectos de los fármacos , Material Particulado/toxicidad , Aire , Adhesión Celular , Línea Celular Tumoral , Supervivencia Celular , Simulación por Computador , Cobre/toxicidad , Relación Dosis-Respuesta a Droga , Diseño de Equipo , Humanos , Hidrodinámica , Pulmón/citología , Nanopartículas/toxicidad , Tamaño de la Partícula
3.
Anal Bioanal Chem ; 401(10): 3213-20, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21695378

RESUMEN

In the field of inhalation toxicology, progress in the development of in vitro methods and efficient exposure strategies now offers the implementation of cellular-based systems. These can be used to analyze the hazardous potency of airborne substances like gases, particles, and complex mixtures (combustion products). In addition, the regulatory authorities require the integration of such approaches to reduce or replace animal experiments. Although the animal experiment currently still has to provide the last proof of the toxicological potency and classification of a certain compound, in vitro testing is gaining more and more importance in toxicological considerations. This paper gives a brief characterization of the CULTEX® Radial Flow System exposure device, which allows the exposure of cultivated cells as well as bacteria under reproducible and stable conditions for studying cellular and genotoxic effects after the exposure at the air-liquid or air-agar interface, respectively. A commercial bronchial epithelial cell line (16HBE14o-) as well as Salmonella typhimurium tester strains were exposed to smoke of different research and commercial available cigarettes. A dose-dependent reduction of cell viability was found in the case of 16HBE14o- cells; S. typhimurium responded with a dose-dependent induction of revertants. The promising results recommend the integration of cellular studies in the field of inhalation toxicology and their regulatory acceptance by advancing appropriate validation studies.


Asunto(s)
Contaminantes Atmosféricos/toxicidad , Citostáticos/toxicidad , Material Particulado/toxicidad , Salmonella typhimurium/efectos de los fármacos , Pruebas de Toxicidad/métodos , Contaminantes Atmosféricos/análisis , Supervivencia Celular/efectos de los fármacos , Células Epiteliales/citología , Células Epiteliales/efectos de los fármacos , Humanos , Pruebas de Mutagenicidad/métodos , Material Particulado/análisis , Humo/efectos adversos , Nicotiana/química
4.
J Biomech ; 43(4): 652-7, 2010 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-19889415

RESUMEN

There is no published data about mask features that impact skin contact pressure during mask ventilation. To investigate the physical factors of skin contact pressure formation. We measured masks with original and reduced air cushion size and recorded contact pressure. We determined cushion contact and mask areas by planimetric measurements. Contact pressures necessary to prevent air leakage during inspiration exceed inspiratory pressure by 1.01+/-0.41 hPa independent of cushion size. Contact area, ventilator pressure and mask area during inspiration and expiration impact contact pressure. Mask contact pressures are higher during expiration. The contact pressure increases with increase in inspiratory pressures independent of the ventilator cycle. During expiration, the contact pressure will increase in proportion to the expiratory pressure reduction of the ventilator. The mask with reduced air cushion size developed higher contact pressures. Contact pressure can be reduced by selecting masks with a small mask area in combination with a large mask cushion.


Asunto(s)
Máscaras , Modelos Biológicos , Respiración Artificial/instrumentación , Mecánica Respiratoria/fisiología , Fenómenos Fisiológicos de la Piel , Simulación por Computador , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Presión
5.
J Aerosol Med ; 18(3): 273-82, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16181002

RESUMEN

Apart from particle size distribution, spray velocity is one of the most important aerosol characteristics that influence lung deposition of inhaled drugs. The time period over which the aerosol is released (spray duration) is also important for coordination of inhalation. Respimat Soft Mist Inhaler (SMI) is a new generation, propellant-free inhaler that delivers drug to the lung much more efficiently than pressurised metered dose inhalers (pMDIs). The objective of this study was to compare the velocity and spray duration of aerosol clouds produced by Respimat SMI with those from a variety of chlorofluorocarbon (CFC) and hydrofluoroalkane (HFA) pMDIs. All inhalers contained solutions or suspensions of bronchodilators. A videorecording method was used to determine the aerosol velocity. For spray duration, the time for generation of the Soft Mist by Respimat SMI was initially determined using three different methods (videorecording [techniques A and B], laser light diffraction and rotating disc). Videorecording was then used to compare the spray duration of Respimat SMI with those from the other inhalers. The Soft Mist produced by Respimat SMI moved much more slowly and had a more prolonged duration than aerosol clouds from pMDIs (mean velocity at a 10-cm distance from the nozzle: Respimat SMI, 0.8 m/sec; pMDIs, 2.0-8.4 m/sec; mean duration: Respimat SMI, 1.5 sec; pMDIs, 0.15-0.36 sec). These characteristics should result in improved lung and reduced oropharyngeal deposition, and are likely to simplify coordination of inhaler actuation and inhalation compared with pMDIs.


Asunto(s)
Aerosoles/administración & dosificación , Inhaladores de Dosis Medida , Nebulizadores y Vaporizadores , Propelentes de Aerosoles/química , Aerosoles/química , Albuterol/administración & dosificación , Albuterol/análogos & derivados , Androstadienos/administración & dosificación , Broncodilatadores/administración & dosificación , Clorofluorocarburos/química , Diseño de Equipo , Fenoterol/administración & dosificación , Fluticasona , Humanos , Hidrocarburos Fluorados/química , Ipratropio/administración & dosificación , Rayos Láser , Tamaño de la Partícula , Reología , Xinafoato de Salmeterol , Factores de Tiempo , Grabación en Video
6.
J Aerosol Med ; 16(3): 283-99, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-14572326

RESUMEN

A new cascade impactor has been designed specifically for pharmaceutical inhaler testing. This impactor, called the Next Generation Pharmaceutical Impactor (NGI), has seven stages and is intended to operate at any inlet flow rate between 30 and 100 L/min. It spans a cut size (D50) range from 0.54-microm to 11.7-microm aerodynamic diameter at 30 L/min and 0.24 microm to 6.12 microm at 100 L/min. The aerodynamics of the impactor follow established scientific principles, giving confident particle size fractionation behavior over the design flow range. The NGI has several features to enhance its utility for inhaler testing. One such feature is that particles are deposited on collection cups that are held in a tray. This tray is removed from the impactor as a single unit, facilitating quick sample turn-around times if multiple trays are used. For accomplishing drug recovery, the user can add up to approximately 40 mL of an appropriate solvent directly to the cups. Another unique feature is a micro-orifice collector (MOC) that captures in a collection cup extremely small particles normally collected on the final filter in other impactors. The particles captured in the MOC cup can be analyzed in the same manner as the particles collected in the other impactor stage cups. The user-friendly features and the aerodynamic design principles together provide an impactor well suited to the needs of the inhaler testing community.


Asunto(s)
Aerosoles , Nebulizadores y Vaporizadores , Administración por Inhalación , Diseño de Equipo , Humanos , Tamaño de la Partícula
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...