Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Cancers (Basel) ; 15(22)2023 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-38001736

RESUMEN

Objectives: We aimed to develop a novel non-linear statistical model integrating primary tumor features on baseline [18F]-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT), molecular subtype, and clinical data for treatment benefit prediction in women with newly diagnosed breast cancer using innovative statistical techniques, as opposed to conventional methodological approaches. Methods: In this single-center retrospective study, we conducted a comprehensive assessment of women newly diagnosed with breast cancer who had undergone a FDG-PET/CT scan for staging prior to treatment. Primary tumor (PT) volume, maximum and mean standardized uptake value (SUVmax and SUVmean), metabolic tumor volume (MTV), and total lesion glycolysis (TLG) were measured on PET/CT. Clinical data including clinical staging (TNM) but also PT anatomical site, histology, receptor status, proliferation index, and molecular subtype were obtained from the medical records. Overall survival (OS), progression-free survival (PFS), and clinical benefit (CB) were assessed as endpoints. A logistic generalized additive model was chosen as the statistical approach to assess the impact of all listed variables on CB. Results: 70 women with newly diagnosed breast cancer (mean age 63.3 ± 15.4 years) were included. The most common location of breast cancer was the upper outer quadrant (40.0%) in the left breast (52.9%). An invasive ductal adenocarcinoma (88.6%) with a high tumor proliferation index (mean ki-67 expression 35.1 ± 24.5%) and molecular subtype B (51.4%) was by far the most detected breast tumor. Most PTs displayed on hybrid imaging a greater volume (12.8 ± 30.4 cm3) with hypermetabolism (mean ± SD of PT maximum SUVmax, SUVmean, MTV, and TLG, respectively: 8.1 ± 7.2, 4.9 ± 4.4, 12.7 ± 30.4, and 47.4 ± 80.2). Higher PT volume (p < 0.01), SUVmax (p = 0.04), SUVmean (p = 0.03), and MTV (<0.01) significantly compromised CB. A considerable majority of patients survived throughout this period (92.8%), while five women died (7.2%). In fact, the OS was 31.7 ± 14.2 months and PFS was 30.2 ± 14.1 months. A multivariate prediction model for CB with excellent accuracy could be developed using age, body mass index (BMI), T, M, PT TLG, and PT volume as predictive parameters. PT volume and PT TLG demonstrated a significant influence on CB in lower ranges; however, beyond a specific cutoff value (respectively, 29.52 cm3 for PT volume and 161.95 cm3 for PT TLG), their impact on CB only reached negligible levels. Ultimately, the absence of distant metastasis M displayed a strong positive impact on CB far ahead of the tumor size T (standardized average estimate 0.88 vs. 0.4). Conclusions: Our results emphasized the pivotal role played by FDG-PET/CT prior to treatment in forecasting treatment outcomes in women newly diagnosed with breast cancer. Nevertheless, careful consideration is required when selecting the methodological approach, as our innovative statistical techniques unveiled non-linear influences of predictive biomarkers on treatment benefit, highlighting also the importance of early breast cancer diagnosis.

2.
J Clin Med ; 12(11)2023 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-37297920

RESUMEN

OBJECTIVES: We aimed to assess the predictive value of the total metabolic tumor burden prior to treatment in patients with advanced non-small-cell lung cancer (NSCLC) receiving immune checkpoint inhibitors (ICIs). METHODS: Pre-treatment 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography (PET/CT) scans performed in two consecutive years for staging in adult patients with confirmed NSCLC were considered. Volume, maximum/mean standardized uptake value (SUVmax/SUVmean), metabolic tumor volume (MTV) and total lesion glycolysis (TLG) were assessed per delineated malignant lesion (including primary tumor, regional lymph nodes and distant metastases) in addition to the morphology of the primary tumor and clinical data. Total metabolic tumor burden was captured by totalMTV and totalTLG. Overall survival (OS), progression-free survival (PFS) and clinical benefit (CB) were used as endpoints for response to treatment. RESULTS: A total of 125 NSCLC patients were included. Osseous metastases were the most frequent distant metastases (n = 17), followed by thoracal distant metastases (pulmonal = 14 and pleural = 13). Total metabolic tumor burden prior to treatment was significantly higher in patients treated with ICIs (mean totalMTV ± standard deviation (SD) 72.2 ± 78.7; mean totalTLG ± SD 462.2 ± 538.9) compared to those without ICI treatment (mean totalMTV ± SD 58.1 ± 233.8; mean totalTLG ± SD 290.0 ± 784.2). Among the patients who received ICIs, a solid morphology of the primary tumor on imaging prior to treatment was the strongest outcome predictor for OS (Hazard ratio HR 28.04, p < 0.01), PFS (HR 30.89, p < 0.01) and CB (parameter estimation PE 3.46, p < 0.01), followed by the metabolic features of the primary tumor. Interestingly, total metabolic tumor burden prior to immunotherapy showed a negligible impact on OS (p = 0.04) and PFS (p = 0.01) after treatment given the hazard ratios of 1.00, but also on CB (p = 0.01) given the PE < 0.01. Overall, biomarkers on pre-treatment PET/CT scans showed greater predictive power in patients receiving ICIs, compared to patients without ICI treatment. CONCLUSIONS: Morphological and metabolic properties of the primary tumors prior to treatment in advanced NSCLC patients treated with ICI showed great outcome prediction performances, as opposed to the pre-treatment total metabolic tumor burdens, captured by totalMTV and totalTLG, both with negligible impact on OS, PFS and CB. However, the outcome prediction performance of the total metabolic tumor burden might be influenced by the value itself (e.g., poorer prediction performance at very high or very low values of total metabolic tumor burden). Further studies including subgroup analysis with regards to different values of total metabolic tumor burden and their respective outcome prediction performances might be needed.

3.
Cancers (Basel) ; 15(5)2023 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-36900312

RESUMEN

We aimed to assess the frequency of additional primary malignancies detected incidentally on [18F]fluoro-D-glucose positron emission tomography/computed tomography (FDG-PET/CT) at staging in NSCLC patients. Moreover, their impact on patient management and survival was assessed. Consecutive NSCLC patients with available staging FDG-PET/CT between 2020 and 2021 were retrospectively enrolled. We reported whether further investigations of suspicious findings presumably not related to NSCLC were recommended and performed after FDG-PET/CT. Any additional imaging, surgery or multimodal management was considered as an impact on patient management. Patient survival was defined using overall survival OS and progression-free survival PFS. A total of 125 NSCLC patients were included, while 26 findings in 26 different patients were suspicious for an additional malignancy on FDG-PET/CT at staging. The most frequent anatomical site was the colon. A total of 54.2% of all additional suspicious lesions turned out to be malignant. Almost every malignant finding had an impact on patient management. No significant differences were found between NSCLC patients with suspicious findings versus no suspicious findings with regards to their survival. FDG-PET/CT performed for staging might be a valuable tool to identify additional primary tumors in NSCLC patients. Identification of additional primary tumors might have substantial implications for patient management. An early detection together with interdisciplinary patient management could prevent a worsening of survival compared to patients with NSCLC only.

4.
Cancers (Basel) ; 14(24)2022 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-36551581

RESUMEN

Objectives: We aimed to investigate the predictive value of baseline 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography (FDG-PET/CT) for durable responses to immune checkpoint inhibitors (ICIs) by linking the morphological and metabolic features of primary tumors (PTs) in nonsmall cell lung cancer (NSCLC) patients. Methods: For the purpose of this single-center study, the imaging data of the patients with a first diagnosis of NSCLC and an available baseline FDG-PET/CT between 2020 and 2021 were retrospectively assessed. The baseline characteristics were collected based on clinical reports and interdisciplinary tumor board documentation. The metabolic (such as standardized uptake value SUV maximum and mean (SUVmax, SUV mean), metabolic tumor volume (MTV), total lesion glycolysis (TLG)) and morphological (such as volume, morphology, margin, and presence of lymphangiosis through imaging) features of all the PTs were retrospectively assessed using FDG-PET/CT. Overall survival (OS), progression-free survival (PFS), clinical benefit (CB) and mortality rate were used as endpoints to define the long-term response to therapy. A backward, stepwise logistic regression analysis was performed in order to define the best model for predicting lasting responses to treatment. Statistical significance was assumed at p < 0.05. Results: A total of 125 patients (median age ± standard deviation (SD) 72.0 ± 9.5 years) were enrolled: 64 men (51.2%) and 61 women (48.8%). Adenocarcinoma was by far the most common histological subtype of NSCLC (47.2%). At the initial diagnosis, the vast majority of all the included patients showed either locally advanced disease (34.4%) or metastatic disease (36.8%). Fifty patients were treated with ICIs either as a first-line (20%) or second-line (20%) therapy, while 75 patients did not receive ICIs. The median values ± SD of PT SUVmax, mean, MTV, and TLG were respectively 10.1 ± 6.0, 6.1 ± 3.5, 13.5 ± 30.7, and 71.4 ± 247.7. The median volume of PT ± SD was 13.7 ± 30.7 cm3. The PTs were most frequently solid (86.4%) with irregular margins (76.8%). Furthermore, in one out of five cases, the morphological evidence of lymphangiosis was seen through imaging (n = 25). The median follow-up ± SD was 18.93 ± 6.98 months. The median values ± SD of OS and PFS were, respectively, 14.80 ± 8.68 months and 14.03 ± 9.02 months. Age, PT volume, SUVmax, TLG, the presence of lymphangiosis features through imaging, and clinical stage IV were very strong long-term outcome predictors of patients treated with ICIs, while no significant outcome predictors could be found for the cohort with no ICI treatment. The optimal cut-off values were determined for PT volume (26.94 cm3) and SUVmax (15.05). Finally, 58% of NSCLC patients treated with ICIs had a CB vs. 78.7% of patients in the cohort with no ICI treatment. However, almost all patients treated with ICIs and with disease progression over time died (mortality in the case of disease progression 95% vs. 62.5% in the cohort without ICIs). Conclusion: Baseline FDG-PET/CT could be used to predict a durable response to ICIs in NSCLC patients. Age, clinical stage IV, lymphangiosis features through imaging, PT volume (thus PT MTV due to a previously demonstrated linear correlation), PT SUVmax, and TLG were very strong long-term outcome predictors. Our results highlight the importance of linking clinical data, as much as morphological features, to the metabolic parameters of primary tumors in a multivariate outcome-predicting model using baseline FDG-PET/CT.

5.
Commun Med (Lond) ; 2: 11, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35603298

RESUMEN

Background: Focal nodular hyperplasia (FNH) is typically considered a benign tumor of the liver without malignant potential. The co-occurrence of FNH and hepatocellular carcinoma (HCC) has been reported in rare cases. In this study we sought to investigate the clonal relationship between these lesions in a patient with FNH-HCC co-occurrence. Methods: A 74-year-old female patient underwent liver tumor resection. The resected nodule was subjected to histologic analyses using hematoxylin and eosin stain and immunohistochemistry. DNA extracted from microdissected FNH and HCC regions was subjected to whole exome sequencing. Clonality analysis were performed using PyClone. Results: Histologic analysis reveals that the nodule consists of an FNH and two adjoining HCC components with distinct histopathological features. Immunophenotypic characterization and genomic analyses suggest that the FNH is clonally related to the HCC components, and is composed of multiple clones at diagnosis, that are likely to have progressed to HCC through clonal selection and/or the acquisition of additional genetic events. Conclusion: To the best of our knowledge, our work is the first study showing a clonal relationship between FNH and HCC. We show that FNH may possess the capability to undergo malignant transformation and to progress to HCC in very rare cases.

6.
HPB (Oxford) ; 24(6): 963-973, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34865990

RESUMEN

BACKGROUND: Percutaneous cholecystostomy (PC) is a treatment option for acute cholecystitis (AC) in cases where cholecystectomy (CCY) is not feasible due to limited health conditions. The use of PC remains questionable. The aim was to retrospectively analyse the outcome of patients after PC. METHODS: All patients who underwent PC for AC at a tertiary referral hospital over 10 years were included. Descriptive statistics, analysed mortality with and without CCY after PC, and a multivariable logistic regression for potential confounder and a landmark sensitivity analysis for immortal time bias were used. RESULTS: Of 158 patients, 79 were treated with PC alone and 79 had PC with subsequent CCY. Without CCY, 48% (38 patients) died compared to 9% with CCY. In the multivariable analysis CCY was associated with 85% lower risk of mortality. The landmark analysis was compatible with the main analyses. Direct PC-complications occurred in 17% patients. Histologically, 22/75 (29%) specimens showed chronic cholecystitis, and 76% AC. CONCLUSION: Due to the high mortality rate of PC alone, performing up-front CCY is proposed. PC represents no definitive treatment for AC and should remain a short-term solution because of the persistent inflammatory focus. According to these findings, almost all specimens showed persistent inflammation.


Asunto(s)
Colecistitis Aguda , Colecistostomía , Colecistectomía/efectos adversos , Colecistostomía/efectos adversos , Humanos , Modelos Logísticos , Estudios Retrospectivos , Resultado del Tratamiento
7.
Acad Radiol ; 22(6): 697-703, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25754800

RESUMEN

RATIONALE AND OBJECTIVES: Selecting the optimal phase for coronary artery evaluation can be challenging, especially at higher heart rates, given that the optimal phase may differ for each of the coronary arteries. This study aimed to evaluate a novel vessel-specific algorithm which automatically outputs the minimum motion phase per coronary artery. MATERIALS AND METHODS: The study included 44 patients who underwent 256-slice cardiac computed tomography for evaluation of chest pain. End-systolic and mid-diastolic minimal motion phases were automatically calculated by a previously validated global motion algorithm and by a new vessel-specific algorithm which calculates the minimum motion for each of the three main coronary arteries, separately. Two readers blindly evaluated all coronary segments for image quality. Median scores per coronary artery were compared by the Wilcoxon signed rank test. RESULTS: The variation, per patient, between the optimal phases of the three coronary arteries was 5.0 ± 4.5% (1%-22%) for end systole and 4.8 ± 4.1% (0%-19%) for mid diastole. The mean image quality scores per coronary artery were 4.0 ± 0.61 for the vessel-specific approach and 3.80 ± 0.69 for the global phase selection (P < .001). Overall, 46 of 122 arteries had a better score with the vessel-specific approach and five with the standard global approach. Interreader agreement was substantial (k = 0.72). CONCLUSIONS: This study has shown that multiple phases are required to ensure optimal image quality for all three coronary arteries and that a vessel-specific phase selection algorithm achieves superior results to the standard global approach.


Asunto(s)
Algoritmos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Diástole , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Sístole
8.
Eur J Radiol ; 80(1): 151-7, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20832221

RESUMEN

PURPOSE: The purpose of this study was to compare planimetric aortic valve area (AVA) measurements from 256-slice CT to those derived from transesophageal echocardiography (TEE) and cardiac catheterization in high-risk subjects with known high-grade calcified aortic stenosis. METHODS AND MATERIALS: The study included 26 subjects (10 males, mean age: 79±6; range, 61-88 years). All subjects were clinically referred for aortic valve imaging prior to percutaneous aortic valve replacement from April 2008 to March 2009. Two radiologists, blinded to the results of TEE and cardiac catheterization, independently selected the systolic cardiac phase of maximum aortic valve area and independently performed manual CT AVA planimetry for all subjects. Repeated AVA measurements were made to establish CT intra- and interobserver repeatability. In addition, the image quality of the aortic valve was rated by both observers. Aortic valve calcification was also quantified. RESULTS: All 26 subjects had a high-grade aortic valve stenosis (systolic opening area <1.0 cm(2)) via CT-based planimetry, with a mean AVA of 0.62±0.18. In four subjects, TEE planimetry was precluded due to severe aortic valve calcification, but CT-planimetry was successfully performed with a mean AVA of 0.46±0.23 cm(2). Mean aortic valve calcium mass score was 563.8±526.2 mg. Aortic valve area by CT was not correlated with aortic valve calcium mass score. A bias and limits of agreement among CT and TEE, CT and cardiac catheterization, and TEE and cardiac catheterization were -0.07 [-0.37 to 0.24], 0.03 [-0.49 to 0.55], 0.12 [-0.39 to 0.63]cm(2), respectively. Differences in AVA among CT and TEE or cardiac catheterization did not differ systematically over the range of measurements and were not correlated with aortic valve calcium mass score. CONCLUSION: Planimetric aortic valve area measurements from 256-slice CT agree well with those derived from TEE and cardiac catheterization in high-risk subjects with known high-grade calcified aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas , Tomografía Computarizada Multidetector , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/terapia , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad
9.
J Endovasc Ther ; 17(6): 677-84, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21142472

RESUMEN

PURPOSE: To evaluate aortic neck changes, specifically aortic neck dilatation, over a 10-year period in patients undergoing endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm. METHODS: All patients who underwent elective EVAR at our institution from 1998 through 2007 were analyzed retrospectively. Among these, 103 patients (96 men; mean age 71 years, range 35-84) who received the 3 most frequently implanted self-expanding stent-grafts (35 Talent, 39 Excluder, and 29 Zenith) and had a minimum 3-month imaging follow-up at our department were selected for this study. All diameters were measured perpendicular to the centerline of flow on computed tomography; baseline data were derived from the first postoperative scan. Stent-graft migration was measured from the lowermost renal artery to the first strut of the stent-graft. Based on intra- and interobserver error measurements, a minimum change of 2 mm defined aortic neck dilatation. RESULTS: During a mean follow-up of 39.4 months (range 3-108.8), infrarenal aortic neck dilatation (>2 mm) was found in 10 patients (28.6%, 95% CI 14.6-46.3) in the Talent group, 4 (10.3%, 95% CI 2.9-24.2) in the Excluder group, and 9 (31.0%, 95% CI 15.3-50.8) in the Zenith group (p=0.299). In 7 (31%) of the 23 patients with neck dilatation, additional therapy was necessary. Suprarenal changes were found in 6 patients (17.1%, 95% CI 6.6-33.6), 8 patients (20.5%, 95% CI 9.3-36.5), and 5 patients (17.2%, 95% CI 5.8-35.8), respectively (p=0.218). Stent-graft migration >2 mm was seen in 2 (1.9%) of the 103 patients in follow-up. The overall endoleak rates were 37.1% for Talent, 30.8% for Excluder, and 37.9% for Zenith (p>0.05). Two patients were converted to open repair owing to Talent stent-graft migration and persistent type I leak (Zenith). The overall reintervention rate was 13.6% (13/103). CONCLUSION: Only a small number of the patients treated with self-expanding stent-grafts show notable infrarenal aortic neck dilatation, which does not appear to be related to the stent-graft model. Almost all cases of aortic neck dilatation exceeded the percentage of oversizing; less than a third of patients with aortic neck dilatation required therapy.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Adulto , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Dilatación Patológica , Procedimientos Quirúrgicos Electivos , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Femenino , Migración de Cuerpo Extraño/etiología , Alemania , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reoperación , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
10.
Int J Cardiovasc Imaging ; 26(6): 711-20, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20339922

RESUMEN

The purpose of this study was to evaluate the potential clinical value of coronary plaque imaging with a new generation CT scanner and the interobserver variability of coronary plaque assessment with a new semiautomatic plaque analysis application. Thirty-five isolated plaques of the left anterior descending coronary artery from 35 patients were evaluated with a new semiautomatic plaque analysis application. All patients were scanned with a 256-slice MDCT scanner (Brilliance iCT, Philips Healthcare, Cleveland OH, USA). Two independent observers evaluated lesion volume, maximum plaque burden, lesion CT number mean and standard deviation, and relative lesion composition. We found 10 noncalcified, 16 mixed, and 9 calcified lesions in our study cohort. Relative interobserver bias and variability for lesion volume were -37%, -13%, -49%, -44% and 28%, 16%, 37%, and 90% for all, noncalcified, mixed, and calcified lesions, respectively. Absolute interobserver bias and variability for relative lesion composition were 1.2%, 0.5%, 1.5%, 1.3% and 3.3%, 4.5%, 7.0%, and 4.4% for all, noncalcified, mixed, and calcified lesions, respectively. While mixed and calcified lesions demonstrated a high degree of lesion volume interobserver variability, noncalcified lesions had a lower degree of lesion volume interobserver variability. In addition, relative noncalcified lesion composition had a very low interobserver variability. Therefore, there may a role for MDCT in serial noncalcified plaque assessment with semiautomatic analysis software.


Asunto(s)
Automatización de Laboratorios , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Calcinosis/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Programas Informáticos , Tomografía Computarizada Espiral
11.
Eur Radiol ; 20(5): 1124-31, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-19915848

RESUMEN

PURPOSE: To compare image quality and effective radiation dose for prospectively gated axial CT coronary angiography on 64- and 256-slice CT. METHODS: The patient cohort consisted of 80 consecutive patients undergoing imaging with 256-slice CT and 80 patients with 64-slice CT. The two patient groups were demographically matched according to age, gender, body mass index and heart rate. For both groups, two observers independently assessed image quality for all coronary segments on a five-point ordinal scale. The two groups were compared with regard to image quality and effective radiation dose. Image quality scores less than 3 were considered non-diagnostic. RESULTS: Mean effective radiation dose did not significantly differ between the two groups (3.4 +/- 0.8 mSv in both groups; p > 0.1). Vessel-based image quality was significantly better in patients undergoing 256-slice CT compared with those undergoing 64-slice CT (p < 0.001). The proportion of assessable coronary segments significantly increased from 95.6% in the 64-slice group to 98.9% in the 256-slice group (p < 0.05). CONCLUSION: Prospectively gated axial CT coronary angiography performed on 256-slice CT provides significantly improved and more stable image quality at an equivalent effective radiation dose compared with 64-slice CT.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Angiografía Coronaria/métodos , Enfermedad Coronaria/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Índice de Masa Corporal , Medios de Contraste/administración & dosificación , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Yopamidol/administración & dosificación , Yopamidol/análogos & derivados , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Estadísticas no Paramétricas
12.
AJR Am J Roentgenol ; 193(4): 1070-6, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19770331

RESUMEN

OBJECTIVE: As diffusion-weighted imaging is increasingly implemented into routine protocols of abdominal MRI, abnormal findings in expected and unexpected locations become more common. The aim of our retrospective study was to investigate the specificity of restricted diffusion in differentiation of benign from malignant abdominal disease. MATERIALS AND METHODS: Two hundred thirty consecutively registered patients underwent abdominal MRI including diffusion-weighted imaging (single-shot spin-echo echo-planar sequence) with b values of 0, 150, 500, and 1,000 s/mm(2). Lesions were detected by two blinded readers using only the images with a b value of 1,000 s/mm(2), and representative apparent diffusion coefficients were measured. Lymph nodes were not documented. RESULTS: Fifty-two of the 230 patients had a total of 55 lesions with restricted diffusion (23.9%). The mean apparent diffusion coefficient was 809 mm(2)/s. Forty-three lesions (78.2%) were malignant. The 12 benign lesions were liver hemangioma, liver adenoma, autoimmune pancreatitis, pancreatic teratoma, two abscesses, three cases of inflammatory bowel wall thickening due to Crohn's disease, Bartholin cyst, hemorrhagic ovarian cyst, and renal Rosai-Dorfman disease. CONCLUSION: Restricted diffusion is generally considered to be associated with malignant tumors because of the high cellularity of these tumors. However, in interpretation of diffusion-weighted images, it should be kept in mind that a number of benign lesions, as many as 22% in our cohort, can exhibit restricted diffusion on images with high b values, thus mimicking malignant lesions.


Asunto(s)
Neoplasias Abdominales/diagnóstico , Artefactos , Imagen de Difusión por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Agua Corporal/metabolismo , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
13.
J Comput Assist Tomogr ; 33(2): 199-203, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19346845

RESUMEN

PURPOSE: In this study, we investigated the influence of sublingual nitroglycerine (NTG) on the peripheral diameter, intraluminal contrast agent density, and image quality of coronary arteries during computed tomography coronary angiography (CTCA). MATERIALS AND METHODS: Thirty patients with sublingual NTG application were matched to 30 patients without NTG. The diameters of the left anterior descending coronary artery (LAD), the left circumflex coronary artery and the right coronary artery were measured at 1-, 4-, and 8-cm length of each vessel as well as the intraluminal contrast agent density along the LAD. Vessel diameters and contrast attenuation at 4 and 8 cm were referenced against the values at 1 cm and processed as percentage reduction. Image quality of the posterior descending artery was assessed subjectively by 2 independent observers. RESULTS: The percentage of peripheral vessel diameter reduction and the peripheral attenuation of contrast agent density for all measured coronary arteries was significantly smaller in the group with NTG administration. The image quality of the posterior descending artery was significantly higher in the group with NTG. CONCLUSIONS: Sublingual administration of NTG before CTCA results in improved diagnostic image quality because of a significant dilatation and improved intraluminal contrast agent density of the peripheral vessels.


Asunto(s)
Angiografía Coronaria/métodos , Vasos Coronarios/efectos de los fármacos , Nitroglicerina/administración & dosificación , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Vasodilatadores/administración & dosificación , Administración Sublingual , Femenino , Humanos , Masculino , Persona de Mediana Edad , Vasodilatación
14.
Acad Radiol ; 16(3): 374-9, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19201367

RESUMEN

RATIONALE AND OBJECTIVES: The aim of this study was to investigate whether a respiratory biofeedback system could increase navigator efficiency and maintain image quality compared to conventional respiratory-gated magnetic resonance coronary angiography (MRCA). MATERIALS AND METHODS: Eighteen healthy volunteers underwent MRCA using three different respiratory-gating protocols. A conventional expiratory free-breathing (FB) sequence was compared to two approaches using navigator echo biofeedback (NEB), a midinspiratory approach (NEBin) and an expiratory approach (NEBex). Navigator data reflecting the position of the diaphragm relative to a 3-mm gating window were made available to the subject using a video projector in combination with a Plexiglas screen and mirror goggles. Image quality was graded by two radiologists in consensus using a visual score ranging from 1 (not visible) to 4 (excellent vessel depiction). RESULTS: The NEB approaches improved navigator efficiency (71.1% with NEBex and 68.0% with NEBin vs 42.2% with FB), thus reducing total imaging time. This difference was statistically significant (P(NEBin)=.007; P(NEBex)=.001). Image quality in the NEBex group was comparable to that in the FB group (median score, 2.44 vs 2.52), but it proved to be significantly lower (median score, 1.94 vs 2.52) for the right coronary artery and the left anterior descending coronary artery in the NEBin group. CONCLUSION: NEB maintains image quality and significantly increases navigator efficiency, thereby decreasing total imaging time by about 40% compared to a conventional FB acquisition strategy.


Asunto(s)
Biorretroalimentación Psicológica/métodos , Vasos Coronarios/anatomía & histología , Aumento de la Imagen/métodos , Angiografía por Resonancia Magnética/métodos , Mecánica Respiratoria , Adulto , Femenino , Humanos , Masculino , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
15.
Eur Radiol ; 19(4): 829-36, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19011864

RESUMEN

To assess image quality and radiation exposure with prospectively gated axial CT coronary angiography (PGA) compared to retrospectively gated helical techniques (RGH). Forty patients with suspected coronary artery disease (CAD) and a stable heart rate below 65 bpm underwent CT coronary angiography (CTCA) using a 64-channel CT system. The patient cohort consisted of 20 consecutive patients examined using a PGA technique and 20 patients examined using a standard RGH technique. Both groups were matched demographically according to age, gender, body mass index, and heart rate. For both groups, two independent observers assessed image quality for all coronary segments on an ordinal scale from 1 (nonassessable) to 5 (excellent quality). Image quality and radiation exposure were compared between patient groups. There were no significant differences in vessel-based image quality between the two groups (P > 0.05). Mean (+/- SD) effective radiation exposure in the PGA group was 3.7 +/- 0.8 mSv compared to 18.9 +/- 3.8 mSv in the RGH group without ECG-based tube current modulation (P < 0.001). Preliminary experience shows PGA technique to be a promising approach for CTCA resulting in a substantial reduction in radiation exposure with image quality comparable to that of standard RGH technique.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Anciano , Algoritmos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Electrocardiografía/métodos , Diseño de Equipo , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos
16.
Int J Cardiovasc Imaging ; 25(2): 209-17, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19051056

RESUMEN

Purpose of this study was the evaluation of the thoracic aortic wall thickness as a potential identifier of patients at increased risk for future cardiac events. Thoracic aortic wall thickness was measured with MDCT in 160 patients. The CT-scans were implemented as non-invasive coronary angiography studies. Relationships between aortic wall thickness, sex, age, major risk factors and atherosclerotic plaque burden of the coronary arteries were explored. Higher values of maximum aortic wall thickness of the descending aorta (women P = 0.02, men P = 0.01) were found in patients with coronary atherosclerosis, compared to patients with same gender but excluded atherosclerosis. Aortic wall thickness of the mid-portion of the descending aorta of 3.0 mm is associated with coronary artery disease (CAD) with a specificity of 96.6% (sensitivity 27.5%) and a positive predictive value (PPV) of 93.3%. For patients with two or more major risk factors and a maximum wall thickness of equal or more than 2.6 mm we found a PPV of 100%. We conclude that measurements of maximum wall thickness of the descending aorta are a potential tool for detecting patients with coronary atherosclerosis. The potential effect of combining measurements of aortic wall thickness at routine chest CT studies with a possible cardiovascular screening is substantial and merits further study.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Aorta Torácica/patología , Enfermedades de la Aorta/patología , Medios de Contraste , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/patología , Femenino , Humanos , Yopamidol/análogos & derivados , Modelos Lineales , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Estudios Retrospectivos , Factores de Riesgo
17.
Radiology ; 249(3): 1010-6, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18849505

RESUMEN

The purpose of this study was to investigate whether spectral computed tomography (CT) has the potential to improve luminal depiction by differentiating among intravascular gadolinium-based contrast agent, calcified plaque, and stent material by using the characteristic k edge of gadolinium. A preclinical spectral CT scanner with a photon-counting detector and six energy threshold levels was used to scan a phantom vessel. A partially occluded stent was simulated by using a calcified plaque isoattenuated to a surrounding gadolinium chelate solution. The reconstructed images showed an effective isolation of the gadolinium with subsequent clear depiction of the perfused vessel lumen. The calcified plaque and the stent material are suppressed.


Asunto(s)
Angiografía Coronaria/métodos , Tomografía Computarizada por Rayos X/métodos , Gadolinio , Fantasmas de Imagen , Fotones , Stents , Tomografía Computarizada por Rayos X/instrumentación
18.
J Comput Assist Tomogr ; 32(4): 602-8, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18664849

RESUMEN

OBJECTIVE: To analyze changes in attenuation of non-contrast-enhanced and contrast-enhanced myocardium throughout the cardiac cycle and to determine the effect of myocardial location, cardiac phase, and dominant coronary perfusion type on myocardial attenuation to evaluate the impact of contraction-dependent factors on multidetector computed tomography (MDCT) perfusion studies. MATERIAL AND METHODS: Cardiac computed tomography imaging was performed on a 40-row MDCT scanner. Myocardial attenuation was assessed in 50 men during 20 cardiac phases. Ninety myocardial regions of interest were placed in the distribution of the right, left anterior descending, and left circumflex coronary arteries on contrast-enhanced MDCT. In 26 patients, myocardial attenuation was also assessed on non-contrast-enhanced MDCT. Myocardial attenuation was analyzed on isopycnic graphs. Attenuation changes due to myocardial contraction were evaluated on non-contrast-enhanced MDCT. The impact of cyclic perfusion on myocardial enhancement was determined on contrast-enhanced MDCT. Student t test and Pearson correlation were used. The influence of dominant coronary perfusion type, supplying coronary artery, and cardiac phase were evaluated using univariate general linear model analysis. RESULTS: Isopycnic graphs revealed that myocardial contraction during systole led to significant increase in myocardial attenuation on non-contrast-enhanced MDCT [ HU systole = 33.2 vs HU diastole = 29.1, P < 0.001]. Reduction in myocardial perfusion during systole led to decrease in myocardial attenuation in contrast-enhanced MDCT [ HU systole = 92.4 vs HU diastole = 111.9, P < 0.001]. Systolic increase in attenuation due to myocardial contraction was far outweighed by the effects of intramyocardial contrast enhancement (correlation Pearson = 0.941). Dominant coronary perfusion did not lead to significant changes in contrast-enhanced myocardium (P = 0.299). Anatomical location and underlying cardiac phase represented significant factors in myocardial attenuation variation (P < 0.001). CONCLUSION: Myocardial attenuation is influenced by cardiac phase and myocardial location. These factors must be considered when analyzing myocardial perfusion with MDCT.


Asunto(s)
Corazón/diagnóstico por imagen , Contracción Miocárdica , Tomografía Computarizada Espiral/métodos , Adulto , Anciano , Dolor en el Pecho , Medios de Contraste/administración & dosificación , Circulación Coronaria , Electrocardiografía/métodos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Periodicidad , Intensificación de Imagen Radiográfica/métodos
19.
J Comput Assist Tomogr ; 32(6): 893-8, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-19204451

RESUMEN

OBJECTIVE: The purpose of this study was to analyze the pulmonary vessel enhancement obtainable using high-density contrast material and saline flushing with automated bolus tracking for multidetector-row computed tomographic (MDCT) pulmonary angiography in a routine clinical setting. METHODS: Attenuation values of pulmonary vessels were retrospectively measured in 51 CT scans performed on a 40-channel MDCT for unselected emergency patients with clinically suspected pulmonary embolism. RESULTS: Mean vascular attenuation measured 326.7 +/- 104 Hounsfield units (HU) in the pulmonary trunk and 299.1 +/- 102 HU in the left distal lower lobe artery. Mean vascular attenuation values in the distal lower lobe artery were equal or higher than 150 HU for 94.1% (48/51) of patients. CONCLUSIONS: In conclusion, the combination of high-density contrast media and saline flushing with automated bolus tracking on a fast CT scanner reliably results in a homogenously high attenuation of pulmonary vessels, allowing precise delineation of clots down to the subsegmental level in MDCT pulmonary angiography.


Asunto(s)
Angiografía/métodos , Yopamidol/análogos & derivados , Arteria Pulmonar/diagnóstico por imagen , Embolia Pulmonar/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...