Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Pak J Pharm Sci ; 30(6): 2321-2327, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29175805

RESUMEN

This is the first meta-analysis to assess the clinical efficiency, safety and potential advantages regarding the use of ABT drains compared with no drainage which is controversial in total knee arthroplasty (TKA).A comprehensive literature search was carried out in March 2015 using the PubMed, Embase, and Cochrane Library databases. A metaanalysis was carried out on two retrospective comparative studies (RCSs) and five randomized controlled trials (RCTs). The number of patients receiving homologous blood transfusion was the primary outcome of the meta-analysis; the secondary outcome measure was the mean drop in Hb level in comparison to the mean pre-operative HB level, the range of flexion of the knee joint, and infections of the wound after surgery. A total of 868 patients, who were included in two retrospective studies and five RCTs, were distributed into subgroups for the meta-analysis. This pooled data showed no benefit of ABT drainage compared no drainage in the homologous blood transfusion rate (13.05% and 16.91%, OR:0.73[0.47,1.13], Z=1.41, P=0.016; and 3.49% and 6.54%, OR: 0.50[0.12,2.01], Z=0.98,P=0.033,respectively in subgroups), Hb drop (Weight mean differences (WMD): 0.20[-0.28,0.68], Z=0.82, P=0.41; WMD:0.16[-0.41,0.55], Z=0.93, P=0.35, respectively), range of flexion of the knee joint (WMD:-0.82 [-3.35,1.70], Z =0.64,P=0.52)and wound infection (OR:0.25[0.61,10.20]; Z =1.28, p=0.2) after TKA surgery. Our findings do not recommend the routine use of postoperative ABT drainage in total knee arthroplasty. Well-designed RCTs with large sample sizes, longer term measures and extensive follow-up period should be performed in the future to update the findings of this study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Transfusión de Sangre Autóloga/métodos , Drenaje/métodos , Articulación de la Rodilla/cirugía , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fenómenos Biomecánicos , Transfusión de Sangre Autóloga/efectos adversos , Drenaje/efectos adversos , Femenino , Humanos , Articulación de la Rodilla/fisiopatología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Rango del Movimiento Articular , Recuperación de la Función , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
2.
BMC Musculoskelet Disord ; 17(1): 452, 2016 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-27806693

RESUMEN

BACKGROUND: Autologous blood transfusion drainage (ABTD) has been used for many years to reduce blood loss in total knee arthroplasty (TKA). We evaluate the current evidence concerning the efficiency and safety of ABTD used in TKA compared with conventional suction drainage (CSD). METHODS: We performed a systematic literature search of the PubMed, Embase, Cochrane Library and four Chinese databases. All randomized controlled trials (RCTs) that compared the effects of ABTD versus CSD in TKA were included in the meta-analysis. RESULTS: Sixteen RCTs involving 1534 patients who compared the effects of ABTD versus CSD were included. Five of the RCTs were performed in Asia, ten in Europe, and one in North America. Patients in the ABTD group had a lower blood transfusion rate (OR: 0.25 [0.13, 0.47]; Z = 4.27, P < 0.0001) and fewer units transfused per patient (WMD: -0.68 [-0.98, -0.39]; Z = 4. 52, P < 0.00001) than did patients in the CSD group. Wound complications, deep vein thrombosis, febrile complications, post-operative hemoglobin days 5-8, drainage volume, and length of hospital stay did not differ significantly between the two types of drainage systems. CONCLUSION: This meta-analysis suggests that ABTD is a safe and effective method that yields a lower blood transfusion rate and fewer units transfused per patient in TKA compared with CSD.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Pérdida de Sangre Quirúrgica/prevención & control , Transfusión de Sangre Autóloga/efectos adversos , Drenaje/efectos adversos , Drenaje/métodos , Recuperación de Sangre Operatoria/efectos adversos , Transfusión de Sangre Autóloga/métodos , Fiebre/epidemiología , Fiebre/etiología , Hemoglobinas/análisis , Humanos , Tiempo de Internación , Periodo Posoperatorio , Ensayos Clínicos Controlados Aleatorios como Asunto , Succión/efectos adversos , Dehiscencia de la Herida Operatoria/epidemiología , Dehiscencia de la Herida Operatoria/etiología , Infección de la Herida Quirúrgica/epidemiología , Infección de la Herida Quirúrgica/etiología , Resultado del Tratamiento , Trombosis de la Vena/epidemiología , Trombosis de la Vena/etiología
3.
BMC Musculoskelet Disord ; 17: 142, 2016 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-27476506

RESUMEN

BACKGROUND: Autologous blood transfusion (ABT) drainage system is a new unwashed salvaged blood retransfusion system for total knee replacement (TKA). However, whether to use ABT drainage, closed-suction (CS) drainage or no drainage in TKA surgery remains controversial. This is the first meta-analysis to assess the clinical efficiency, safety and potential advantages regarding the use of ABT drains compared with closed-suction/no drainage. METHODS: PubMed, Embase, and the Cochrane Library were comprehensively searched in March 2015. Fifteen randomized controlled trials (RCTs) were identified and pooled for statistical analysis. The primary outcome evaluated was homologous blood transfusion rate. The secondary outcomes were post-operative haemoglobin on days 3-5, length of hospital stay and wound infections after TKA surgery. RESULTS: The pooled data included 1,721 patients and showed that patients in the ABT drainage group might benefit from lower blood transfusion rates (16.59 % and 37.47 %, OR: 0.28 [0.14, 0.55]; 13.05 % and 16.91 %, OR: 0.73 [0.47,1.13], respectively). Autologous blood transfusion drainage and closed-suction drainage/no drainage have similar clinical efficacy and safety with regard to post-operative haemoglobin on days 3-5, length of hospital stay and wound infections. CONCLUSIONS: Autologous blood transfusion drainage offers a safe and efficient alternative to CS/no drainage with a lower blood transfusion rate. Future large-volume high-quality RCTs with extensive follow-up will affirm and update this system review.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Pérdida de Sangre Quirúrgica/prevención & control , Transfusión de Sangre Autóloga/métodos , Recuperación de Sangre Operatoria/métodos , Transfusión de Sangre Autóloga/efectos adversos , Transfusión de Sangre Autóloga/estadística & datos numéricos , Drenaje , Hemoglobinas/análisis , Humanos , Tiempo de Internación , Recuperación de Sangre Operatoria/efectos adversos , Recuperación de Sangre Operatoria/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Periodo Posoperatorio , Ensayos Clínicos Controlados Aleatorios como Asunto , Succión , Resultado del Tratamiento
4.
Sci Rep ; 6: 27461, 2016 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-27364944

RESUMEN

The use of a postoperative autotransfusion drain (PATD) to reduce allogenic blood transfusions in total hip arthroplasty (THA) remains controversial. Therefore, we conducted a meta-analysis to evaluate the efficacy and safety of this technique. Randomized controlled trials (RCTs) were identified from PubMed, Embase, and the Cochrane Central Register of Controlled Trials (CENTRAL). Thirteen RCTs (1,424 participants) were included in our meta-analysis. The results showed that PATD reduced the rate of allogenic transfusions (RR = 0.56; 95% CI [0.40, 0.77]) and total blood loss (MD = -196.04; 95% CI [-311.01, -81.07]). Haemoglobin (Hb) levels were higher in the PATD group on postoperative day 1 (MD = 0.28; 95% CI [0.06, 0.49]), but no significant differences on postoperative days 2 or 3 (MD = 0.29; 95% CI [-0.02, 0.60]; MD = 0.26; 95% CI [-0.04, 0.56]; respectively). There were no differences in length of hospital stay (MD = -0.18; 95% CI [-0.61, 0.25]), febrile reaction (RR = 1.26; 95% CI [0.95, 1.67]), infection (RR = 0.95; 95% CI [0.54, 1.65]), wound problems (RR = 1.07; 95% CI [0.87, 1.33]), or serious adverse events (RR = 0.59; 95% CI [0.10, 3.58]). Our findings suggest that PATD is effective in reducing the rate of allogenic transfusion. However, the included studies are inadequately powered to conclusively determine the safety of this technique.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Transfusión de Sangre Autóloga/métodos , Hemorragia Posoperatoria/prevención & control , Artroplastia de Reemplazo de Cadera/efectos adversos , Transfusión Sanguínea/estadística & datos numéricos , Transfusión de Sangre Autóloga/efectos adversos , Drenaje , Hemoglobinas/metabolismo , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA