Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Eur J Clin Pharmacol ; 71(7): 811-6, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25980838

RESUMEN

PURPOSE: The aim of this study was to develop a clinically applicable limited sampling strategy for ambulatory Caucasian kidney transplant patients to estimate area under the curve in a 24-h period (AUC0-24) of prolonged-release tacrolimus. METHODS: Twenty six kidney recipients, at least 6 months after transplantation, receiving prolonged-release tacrolimus, were enrolled. In each patient, seven blood samples were collected during a period of 24 h by use of the validated dried blood spot method. Best subset selection multiple linear regression was performed to derive limited sampling strategy (LSS). The equations were constrained to include a maximum of three samples collected within 4 h after the intake to maintain clinical applicability. To assess the predictive performance of LSS, residuals for each patient were calculated based on models fitted to a dataset where that patient was omitted. RESULTS: The prediction formula for the AUC(0-24) using the time points 0, 2, and 4 h after ingestion (C(0h)-C(2h)-C(4h)) provided the highest correlation with the AUC(0-24) (r(2) = 0.95): AUC0-24 = 44.9 + 8.9 × C(0h) + 2.1 × C(2h) + 7.6 × C(4h). Measures for bias and precision, i.e., median percentage prediction error (MPPE) and median absolute prediction error (MAPE), were 0.4 and 4.8%, respectively. For the same patients, the correlation between C(24h) and AUC0-24 was worse (r(2) = 0.77) while MPPE and MAPE were 6.2 and 7.2%, respectively. CONCLUSION: In the outpatient department, a LSS using C(0h)-C(2h)-C(4h) can be used for reliable estimation of the AUC(0-24) of prolonged-release tacrolimus.


Asunto(s)
Inhibidores de la Calcineurina/sangre , Pruebas con Sangre Seca , Monitoreo de Drogas/métodos , Inmunosupresores/sangre , Trasplante de Riñón , Tacrolimus/sangre , Adulto , Área Bajo la Curva , Inhibidores de la Calcineurina/administración & dosificación , Inhibidores de la Calcineurina/farmacocinética , Preparaciones de Acción Retardada , Femenino , Rechazo de Injerto/inmunología , Rechazo de Injerto/prevención & control , Supervivencia de Injerto/efectos de los fármacos , Humanos , Inmunosupresores/administración & dosificación , Inmunosupresores/farmacocinética , Trasplante de Riñón/efectos adversos , Modelos Lineales , Masculino , Persona de Mediana Edad , Modelos Biológicos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Tacrolimus/administración & dosificación , Tacrolimus/farmacocinética , Resultado del Tratamiento
2.
J Pharm Biomed Anal ; 50(4): 664-70, 2009 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-19155152

RESUMEN

An assay of everolimus based on finger prick sampling and consecutive application as a blood spot on sampling paper has been developed. We explored several methods [K. Hoogtanders, J. van der Heijden, M. Christiaans, P. Edelbroek, J. van Hooff, L. Stolk, J. Pharm. Biomed. Anal. 44 (2006) 658-664; A. Allanson, M. Cotton, J. Tettey, et al., J. Pharm. Biomed. Anal. 44 (2007) 963-969] and developed a new method, namely the impregnation of sampling paper with a solution of plasma-protein, formic acid and ammonium acetate, in combination with the extraction of the blood spot by filter filtration. This kind of sample preparation provides new possibilities for blood spot sampling especially if analytes are adsorbed to the paper. The dried blood spot was analysed using the HPLC-electrospray-tandem mass spectrometry method, with 32-desmethoxyrapamycin as the internal standard. The working range of our study was 2-30 microg/l. Within this range, intra-and inter-assay variability for precision and accuracy was <15%. Everolimus blood spot samples proved stable for 3 days at 60 degrees C and for 32 days at 4 degrees C. Everolimus concentrations of one stable out-patient were compared after both blood spot sampling and conventional venous sampling on various occasions. Results indicate that this new method is promising for therapeutic drug monitoring in stable renal transplant patients.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Inmunosupresores/sangre , Sirolimus/análogos & derivados , Espectrometría de Masas en Tándem/métodos , Recolección de Muestras de Sangre/métodos , Monitoreo de Drogas/métodos , Everolimus , Humanos , Trasplante de Riñón , Reproducibilidad de los Resultados , Sirolimus/sangre , Manejo de Especímenes/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Temperatura , Factores de Tiempo
3.
J Pharm Biomed Anal ; 44(3): 658-64, 2007 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-17184953

RESUMEN

In a preliminary investigation an assay for tacrolimus based on fingerprick sampling and consecutive application as a blood spot on sampling paper has been developed. The dried blood spot was analysed by HPLC-tandem mass spectrometry. The validated range was 1-30 microg/l. Intra- and inter-assay variability for precision and accuracy was <7.5% and 15%, respectively. Tacrolimus concentrations of 24 stable out patients were compared after both blood spot sampling and conventional venous sampling. Method agreement was investigated with the methods of Passing and Bablok and Bland Altman and proved suitable for clinical use. The dried blood spot method for tacrolimus seems promising for patient monitoring.


Asunto(s)
Monitoreo de Drogas , Inmunosupresores/sangre , Tacrolimus/sangre , Recolección de Muestras de Sangre/métodos , Calibración , Cromatografía Líquida de Alta Presión , Dedos/irrigación sanguínea , Humanos , Inmunosupresores/química , Estructura Molecular , Pacientes Ambulatorios , Estándares de Referencia , Análisis de Regresión , Reproducibilidad de los Resultados , Tacrolimus/análogos & derivados , Tacrolimus/química , Espectrometría de Masas en Tándem
4.
Pharm World Sci ; 21(1): 40-3, 1999 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10214668

RESUMEN

A simple method is proposed for analysis of stimulant laxatives and metabolites of laxatives in urine. All stimulant laxatives commercially available in Germany, Belgium and the Netherlands, the diphenylmethane derivatives and the anthraquinones, were included. Chromatography was performed with a standardized isocratic HPLC system with diode array detection ('STIP'), which is commonly used in the Netherlands for toxicological screening. The method was validated by ingestion of a normal dose of the laxatives by human volunteers. In all cases the expected laxative metabolite could be detected in urine twelve hours after intake. Also urine samples of patients, suspected of laxative abuse, were analyzed.


Asunto(s)
Catárticos , Detección de Abuso de Sustancias/métodos , Adulto , Catárticos/farmacocinética , Cromatografía Líquida de Alta Presión , Cromatografía en Capa Delgada , Glucuronatos/orina , Humanos , Indicadores y Reactivos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Espectrofotometría Ultravioleta
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA