Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biosens Bioelectron ; 262: 116524, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38971036

RESUMEN

The lateral flow assay (LFA) is an ideal technology for at-home medical diagnostic tests due to its ease of use, cost-effectiveness, and rapid results. Despite these advantages, only few LFAs, such as the pregnancy and COVID-19 tests, have been translated from the laboratory to the homes of patients. To date, the medical applicability of LFAs is limited by the fact that they only provide yes/no answers unless combined with optical readers that are too expensive for at-home applications. Furthermore, LFAs are unable to compete with the state-of-the-art technologies in centralized laboratories in terms of detection limits. To address those shortcomings, we have developed an electrochemical readout procedure to enable quantitative and sensitive LFAs. This technique is based on a voltage-triggered in-situ dissolution of gold nanoparticles, the conventional label used to visualize target-specific signals on the test line in LFAs. Following the dissolution, the amount of gold is measured by electroplating onto an electrode and subsequent electrochemical quantification of the deposited gold. The measured current has a low noise, which achieves superior detection limits compared to optical techniques where background light scattering is limiting the readout performance. In addition, the hardware for the readout was developed to demonstrate translatability towards low-cost electronics.

2.
MRS Commun ; 14(3): 261-266, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38966401

RESUMEN

Microelectrode arrays (MEAs) have applications in drug discovery, toxicology, and basic research. They measure the electrophysiological response of tissue cultures to quantify changes upon exposure to biochemical stimuli. Unfortunately, manual addition of chemicals introduces significant noise in the recordings. Here, we report a simple-to-fabricate fluidic system that addresses this issue. We show that cell cultures can be successfully established in the fluidic compartment under continuous flow conditions and that the addition of chemicals introduces minimal noise in the recordings. This dynamic cell culture system represents an improvement over traditional tissue culture wells used in MEAs, facilitating electrophysiology measurements.

3.
Adv Sci (Weinh) ; 11(8): e2306727, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38155358

RESUMEN

Infectious diseases are increasingly recognized as a major threat worldwide due to the rise of antimicrobial resistance and the emergence of novel pathogens. In vitro models that can adequately mimic in vivo gastrointestinal physiology are in high demand to elucidate mechanisms behind pathogen infectivity, and to aid the design of effective preventive and therapeutic interventions. There exists a trade-off between simple and high throughput models and those that are more complex and physiologically relevant. The complexity of the model used shall be guided by the biological question to be addressed. This review provides an overview of the structure and function of the intestine and the models that are developed to emulate this. Conventional models are discussed in addition to emerging models which employ engineering principles to equip them with necessary advanced monitoring capabilities for intestinal host-pathogen interrogation. Limitations of current models and future perspectives on the field are presented.


Asunto(s)
Intestinos , Organoides , Interacciones Huésped-Patógeno
4.
ACS Sens ; 7(7): 1967-1976, 2022 07 22.
Artículo en Inglés | MEDLINE | ID: mdl-35801574

RESUMEN

This work demonstrates a lateral flow assay concept on the basis of stochastic-impact electrochemistry. To this end, we first elucidate requirements to employ silver nanoparticles as redox-active labels. Then, we present a prototype that utilizes nanoimpacts from biotinylated silver nanoparticles as readouts to detect free biotin in solution based on competitive binding. The detection is performed in a membrane-based microfluidic system, where free biotin and biotinylated particles compete for streptavidin immobilized on embedded latex beads. Excess nanoparticles are then registered downstream at an array of detection electrodes. In this way, we establish a proof of concept that serves as a blueprint for future "digital" lateral flow sensors.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Unión Competitiva , Biotina , Electroquímica , Plata
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA