Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ecotoxicol Environ Saf ; 178: 105-112, 2019 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-30999178

RESUMEN

Human hair, flue gas and fly ash from a municipal solid waste incinerator (MSWI) in south China were collected and analyzed for polychlorinated dibenzo-p-dioxin (PCDD) and polychlorinated dibenzofuran (PCDF). The ΣPCDD/F level in hair from male workers were higher than those from residents. The Principal Component Analysis (PCA) suggested that ΣPCDD/F in flue gas is an external source of male workers' hair ΣPCDD/F. Results of daily intake of ΣPCDD/F by inhaling flue gas suggested that the inhalation exposure of ΣPCDD/F was at a slight health risk. For the male workers directly exposed to the MSWI power plant, ΣPCDD/F levels in their hair were significantly higher than those who were non-directly exposed. Moreover, a significantly positive relationship was obtained between ΣPCDD/F levels in male workers' hair and the working time. The result of correlation analysis suggested that 1,2,3,4,6,7,8-HpCDD and OCDD could be level indicator congeners to estimate ΣPCDD/F levels. In addition, 2,3,7,8-TCDD could be applied as TEQ indicator congener to characterize the hair of MSWI male workers.


Asunto(s)
Dibenzofuranos Policlorados/análisis , Cabello/química , Incineración , Exposición por Inhalación/análisis , Exposición Profesional/análisis , Dibenzodioxinas Policloradas/análisis , China , Ceniza del Carbón/análisis , Humanos , Masculino , Residuos Sólidos/análisis
2.
Huan Jing Ke Xue ; 38(2): 502-509, 2017 Feb 08.
Artículo en Chino | MEDLINE | ID: mdl-29964505

RESUMEN

This paper analyzed 17 polychlorinated dibenzo-p-dioxins and dibenzofurans(PCDD/Fs) by HRGC/HRMS in the flue gas of a certain municipal solid waste incinerator(MSWI) and its surrounding air and other possible sources in Guangdong. It discussed the feature of homologs and main toxic monomers in all samples. It also investigated the relationship among surrounding area, MSWI and possible sources using principle component analysis (PCA) and cluster analysis. The results showed that the concentration of PCDD/Fs was higher in the flue gas than the ambient air, moreover non-effect suffered by prevailing wind direction. The possible sources might be tyre factory and open burning based on spot survey. The concentration of PCDD/Fs was lower in tyre factory than upwind station, but higher at open burning spot than outdrop monitoring station. The analysis of homologs showed that OCDD, 1,2,3,4,6,7,8-HpCDD and 1,2,3,4,6,7,8-HpCDF were the main materials in the flue gas and air, meanwhile OCDF was also found in atmosphere. There was similar feature of 17 PCDD/Fs between surrounding monitoring station and tyre factory, and the same between flue gas and open burning. The further analysis showed that the linearly dependent coefficients of 1,2,3,7,8-PeCDD and 2,3,4,6,7,8-HxCDF were 0.95 and 0.75, respectively. It showed the strong correlation of two monomers in all ambient air samples. The PCA and cluster analysis showed that MSWI influenced the surrounding air, tyre factory had an impact on upwind station, and open burning had a lower effect on outdrop monitoring station.

3.
Huan Jing Ke Xue ; 35(7): 2645-9, 2014 Jul.
Artículo en Chino | MEDLINE | ID: mdl-25244850

RESUMEN

Concentrations and distribution characteristics of 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins and dibenzofurans (2,3,7,8-PCDD/Fs) were analyzed in waste water from a paper mill. And concentrations of 2,3,7,8-PCDD/Fs in waste water before and after electron beam irradiation with different doses were compared. The feasibility, mechanism and rates of 2,3,7,8-PCDD/Fs degradation were discussed. The PCDD/Fs concentrations and corresponding I-TEQ (toxic equivalent quantity) values were 239 pg x L(-1) and 41.0 pg x L(-1), respectively, in the waste water. The concentrations of total 2,3,7,8-PCDD/Fs decreased after electron beam radiolysis at a dose of 30 kGy and 60 kGy with degradation rates of 5.27% and 23.6%, respectively.


Asunto(s)
Benzofuranos/análisis , Papel , Dibenzodioxinas Policloradas/análogos & derivados , Polímeros/análisis , Aguas Residuales/química , Purificación del Agua/métodos , Electrones , Industrias , Dibenzodioxinas Policloradas/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...