Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
PLoS One ; 19(4): e0296300, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38635518

RESUMEN

OBJECTIVE: This study aimed to compare the stability and mechanical properties of the double chevron-cut (DCC) and biplanar (BP) distal femoral osteotomy (DFO) techniques, along with analyzing their respective contact surface areas. METHODS: Biomechanical testing was performed using sawbone and 3D modeling techniques to assess axial and torsional stability, torsional stiffness, and maximum torque of both osteotomy configurations. Additionally, 3D models of the sawbone femur were created to calculate and compare the contact surface area of the DCC, BP, and conventional single-plane DFO techniques. RESULTS: Axial stiffness and maximum strength did not significantly differ between the two osteotomy techniques. However, in terms of torsional properties, the DCC technique exhibited superior torsional stiffness compared to the BP group (27 ± 7.7 Nm/° vs. 4.5 ± 1.5 Nm/°, p = 0.008). Although the difference in maximum torque did not reach statistical significance (63 ± 10.6 vs. 56 ± 12.1, p = 0.87), it is noteworthy that the DCC group sawbone model exhibited fracture in the shaft region instead of at the osteotomy site. Therefore, the actual maximum torque of the DCC construct may not be accurately reflected by the numerical values obtained in this study. The contact surface area analysis revealed that the BP configuration had the largest contact surface area, 111% larger than that of the single-plane configuration. but 60% of it relied on the less reliable axial cut. Conversely, the DCC osteotomy offered a 31% larger contact surface area than the single-plane configuration, with both surfaces being weight-bearing. CONCLUSION: The DCC osteotomy exhibited superior mechanical stability, showing improved rotational stiffness and maximum torque when compared to the BP osteotomy. Although the BP osteotomy resulted in a larger contact surface area than the DCC osteotomy, both were larger than the conventional single-plane configuration. In clinical practice, both the DCC and BP techniques should be evaluated based on patient-specific characteristics and surgical goals.


Asunto(s)
Fracturas Óseas , Osteotomía , Humanos , Osteotomía/métodos , Fémur/cirugía , Torque , Extremidad Inferior , Fenómenos Biomecánicos
3.
BMC Urol ; 22(1): 56, 2022 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35413871

RESUMEN

This study aimed to investigate clinical effectiveness of stone disintegration by using isolation coupling pad ("icPad") as coupling medium to reduce trapped air pockets during extracorporeal shock wave lithotripsy (ESWL). Patients underwent ESWL between Oct. 2017 and May 2018 were enrolled in this clinical observational study. An electromagnetic lithotripter (Dornier MedTech Europe GmbH Co., Germany) was used in this study. Patients were divided into icPad group P1, P2 and semi-gel group C by different coupling medium. The energy level and total number of shock wave (SW) for group P1 and C was set at level 2 and 3000 and group P2 at level 3 and 2500. The successful stone disintegration rate (SSDR) was determined to evaluate the treatment outcome. All patients were evaluated by KUB film and ultrasonography after 90 days. Complications during ESWL were recorded. A total of 300 patients satisfied the inclusion criteria. There were no significant differences in characteristics of patients and stone among three groups. The corresponding SSDRs for patients in group P1, P2 and C was 73.0%, 73.2% and 55.3%, respectively. The SSDR in group P1 was statistically higher than Group C. Comparing to semi-liquid gel, coupling medium using by icPad could achieve better treatment outcome of stone disintegration in ESWL.


Asunto(s)
Cálculos Renales , Litotricia , Cálculos Ureterales , Fatiga , Humanos , Cálculos Renales/terapia , Resultado del Tratamiento , Cálculos Ureterales/terapia
4.
Sensors (Basel) ; 12(10): 14158-78, 2012 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-23202042

RESUMEN

A growing number of educational studies apply sensors to improve student learning in real classroom settings. However, how can sensors be integrated into classrooms to help instructors find out students' reading concentration rates and thus better increase learning effectiveness? The aim of the current study was to develop a reading concentration monitoring system for use with e-books in an intelligent classroom and to help instructors find out the students' reading concentration rates. The proposed system uses three types of sensor technologies, namely a webcam, heartbeat sensor, and blood oxygen sensor to detect the learning behaviors of students by capturing various physiological signals. An artificial bee colony (ABC) optimization approach is applied to the data gathered from these sensors to help instructors understand their students' reading concentration rates in a classroom learning environment. The results show that the use of the ABC algorithm in the proposed system can effectively obtain near-optimal solutions. The system has a user-friendly graphical interface, making it easy for instructors to clearly understand the reading status of their students.


Asunto(s)
Atención/fisiología , Monitoreo Fisiológico/instrumentación , Lectura , Estudiantes/psicología , Algoritmos , Animales , Inteligencia Artificial , Abejas/fisiología , Libros , Humanos , Aplicaciones Móviles , Monitoreo Fisiológico/métodos , Instituciones Académicas
5.
J Periodontal Res ; 40(1): 1-10, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15613073

RESUMEN

BACKGROUND: Bone morphogenetic proteins (BMPs) may play significant roles in bone formation. The ability of BMP-6 to promote wound healing has been chosen as the subject of this investigation. In this study, a synthetic rat BMP-6 polypeptide was applied to a periodontal fenestration defect in rats to elucidate the effects of BMP-6 on periodontal wound healing. MATERIAL AND METHODS: Following surgery to create a bony window on the buccal aspects of mandibular molar roots, 24 male Sprague Dawley rats were divided into four groups according to BMP application (0, 1, 3 and 10 microg, respectively). Animals were killed after 28 days and the mandible taken for histological examination. Histometric measurements were performed on sections selected from three levels (coronal, middle and apical levels; with 240 microm apart from the central) of the defect. New bone and cementum formation (including area and thickness) were analyzed and compared. RESULTS: In general, minimal new bone was observed on the surgically created defects in the non-BMP group, whereas a complete osseous healing occurred in all BMP-6 treated animals. New bone formation (both in area and thickness) was significantly influenced by both the dosage and the examining level, whereas new cementum formation was affected by dosage only. An increase in bone and cementum formation was noted in all three BMP groups when compared with the control group at all examined levels. Among the BMP groups, greatest new bone and cementum formation were noted in the 3 microg group. New cementum thickness increased on the cementum surfaces of the defects compared with the dentinal surfaces in all study groups. CONCLUSION: An increase in new bone and cementum formation was noted after applying a synthetic BMP-6 polypeptide to a periodontal fenestration defect in rats. Therefore, we suggest that BMP-6 may play a certain role in periodontal regeneration.


Asunto(s)
Pérdida de Hueso Alveolar/tratamiento farmacológico , Proteínas Morfogenéticas Óseas/farmacología , Regeneración Ósea/efectos de los fármacos , Cemento Dental/efectos de los fármacos , Cicatrización de Heridas/efectos de los fármacos , Pérdida de Hueso Alveolar/patología , Animales , Proteína Morfogenética Ósea 6 , Masculino , Mandíbula/efectos de los fármacos , Mandíbula/patología , Ratas , Ratas Sprague-Dawley
6.
Drug Dev Ind Pharm ; 28(5): 593-9, 2002 May.
Artículo en Inglés | MEDLINE | ID: mdl-12098848

RESUMEN

Development of an extended release oral dosage form for nifedipine using the non-uniform drug distribution matrix method was conducted. The process conducted in a fluid bed processing unit was optimized by controlling the concentration gradient of nifedipine in the coating solution and the spray rate applied to the non-pareil beads. The concentration of nifedipine in the coating was controlled by instantaneous dilutions of coating solution with polymer dispersion transported from another reservoir into the coating solution at a controlled rate. The USP dissolution method equipped with paddles at 100 rpm in 0.1 N hydrochloric acid solution maintained at 37 degrees C was used for the evaluation of release rate characteristics. Results indicated that (1) an increase in the ethyl cellulose content in the coated beads decreased the nifedipine release rate, (2) incorporation of water-soluble sucrose into the formulation increased the release rate of nifedipine, and (3) adjustment of the spray coating solution and the transport rate of polymer dispersion could achieve a dosage form with a zero-order release rate. Since zero-order release rate and constant plasma concentration were achieved in this study using the non-uniform drug distribution technique, further studies to determine in vivo/in vitro correlation with various non-uniform drug distribution dosage forms will be conducted.


Asunto(s)
Celulosa/análogos & derivados , Composición de Medicamentos/métodos , Preparaciones Farmacéuticas/química , Administración Oral , Animales , Celulosa/química , Química Farmacéutica , Preparaciones de Acción Retardada , Cinética , Nifedipino/administración & dosificación , Nifedipino/química , Nifedipino/farmacocinética , Preparaciones Farmacéuticas/administración & dosificación , Conejos , Solubilidad , Tecnología Farmacéutica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA