1.
Intensive Care Med Exp ; 12(1): 60, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38954052

RESUMEN

BACKGROUND: The spatiotemporal progression and patterns of tissue deformation in ventilator-induced lung injury (VILI) remain understudied. Our aim was to identify lung clusters based on their regional mechanical behavior over space and time in lungs subjected to VILI using machine-learning techniques. RESULTS: Ten anesthetized pigs (27 ± 2 kg) were studied. Eight subjects were analyzed. End-inspiratory and end-expiratory lung computed tomography scans were performed at the beginning and after 12 h of one-hit VILI model. Regional image-based biomechanical analysis was used to determine end-expiratory aeration, tidal recruitment, and volumetric strain for both early and late stages. Clustering analysis was performed using principal component analysis and K-Means algorithms. We identified three different clusters of lung tissue: Stable, Recruitable Unstable, and Non-Recruitable Unstable. End-expiratory aeration, tidal recruitment, and volumetric strain were significantly different between clusters at early stage. At late stage, we found a step loss of end-expiratory aeration among clusters, lowest in Stable, followed by Unstable Recruitable, and highest in the Unstable Non-Recruitable cluster. Volumetric strain remaining unchanged in the Stable cluster, with slight increases in the Recruitable cluster, and strong reduction in the Unstable Non-Recruitable cluster. CONCLUSIONS: VILI is a regional and dynamic phenomenon. Using unbiased machine-learning techniques we can identify the coexistence of three functional lung tissue compartments with different spatiotemporal regional biomechanical behavior.

2.
NPJ Digit Med ; 7(1): 198, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39060511

RESUMEN

Ventilatory thresholds (VTs) are key physiological parameters used to evaluate physical performance and determine aerobic and anaerobic transitions during exercise. Current assessment of these parameters requires ergospirometry, limiting evaluation to laboratory or clinical settings. In this work, we introduce a wearable respiratory system that continuously tracks breathing during exercise and estimates VTs during ramp tests. We validate the respiratory rate and VTs predictions in 17 healthy adults using ergospirometry analysis. In addition, we use the wearable system to evaluate VTs in 107 recreational athletes during ramp tests outside the laboratory and show that the mean population values agree with physiological variables traditionally used to exercise prescription. We envision that respiratory wearables can be useful in determining aerobic and anaerobic parameters with promising applications in health telemonitoring and human performance.

3.
Acta Biomater ; 181: 282-296, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38705223

RESUMEN

Irreversible alveolar airspace enlargement is the main characteristic of pulmonary emphysema, which has been extensively studied using animal models. While the alterations in lung mechanics associated with these morphological changes have been documented in the literature, the study of the mechanical behavior of parenchymal tissue from emphysematous lungs has been poorly investigated. In this work, we characterize the mechanical and morphological properties of lung tissue in elastase-induced emphysema rat models under varying severity conditions. We analyze the non-linear tissue behavior using suitable hyperelastic constitutive models that enable to compare different non-linear responses in terms of hyperelastic material parameters. We further analyze the effect of the elastase dose on alveolar morphology and tissue material parameters and study their connection with respiratory-system mechanical parameters. Our results show that while the lung mechanical function is not significantly influenced by the elastase treatment, the tissue mechanical behavior and alveolar morphology are markedly affected by it. We further show a strong association between alveolar enlargement and tissue softening, not evidenced by respiratory-system compliance. Our findings highlight the importance of understanding tissue mechanics in emphysematous lungs, as changes in tissue properties could detect the early stages of emphysema remodeling. STATEMENT OF SIGNIFICANCE: Gas exchange is vital for life and strongly relies on the mechanical function of the lungs. Pulmonary emphysema is a prevalent respiratory disease where alveolar walls are damaged, causing alveolar enlargement that induces harmful changes in the mechanical response of the lungs. In this work, we study how the mechanical properties of lung tissue change during emphysema. Our results from animal models show that tissue properties are more sensitive to alveolar enlargement due to emphysema than other mechanical properties that describe the function of the whole respiratory system.


Asunto(s)
Elastasa Pancreática , Enfisema Pulmonar , Animales , Enfisema Pulmonar/patología , Enfisema Pulmonar/fisiopatología , Pulmón/patología , Ratas , Masculino , Alveolos Pulmonares/patología , Fenómenos Biomecánicos
5.
Med Image Anal ; 89: 102925, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37598608

RESUMEN

The diagnosis of heart failure usually includes a global functional assessment, such as ejection fraction measured by magnetic resonance imaging. However, these metrics have low discriminate power to distinguish different cardiomyopathies, which may not affect the global function of the heart. Quantifying local deformations in the form of cardiac strain can provide helpful information, but it remains a challenge. In this work, we introduce WarpPINN, a physics-informed neural network to perform image registration to obtain local metrics of heart deformation. We apply this method to cine magnetic resonance images to estimate the motion during the cardiac cycle. We inform our neural network of the near-incompressibility of cardiac tissue by penalizing the Jacobian of the deformation field. The loss function has two components: an intensity-based similarity term between the reference and the warped template images, and a regularizer that represents the hyperelastic behavior of the tissue. The architecture of the neural network allows us to easily compute the strain via automatic differentiation to assess cardiac activity. We use Fourier feature mappings to overcome the spectral bias of neural networks, allowing us to capture discontinuities in the strain field. The algorithm is tested on synthetic examples and on a cine SSFP MRI benchmark of 15 healthy volunteers, where it is trained to learn the deformation mapping of each case. We outperform current methodologies in landmark tracking and provide physiological strain estimations in the radial and circumferential directions. WarpPINN provides precise measurements of local cardiac deformations that can be used for a better diagnosis of heart failure and can be used for general image registration tasks. Source code is available at https://github.com/fsahli/WarpPINN.


Asunto(s)
Insuficiencia Cardíaca , Imagen por Resonancia Magnética , Humanos , Redes Neurales de la Computación , Corazón/diagnóstico por imagen , Física
6.
Front Bioeng Biotechnol ; 11: 1271760, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38192638

RESUMEN

Introduction: Chronic Obstructive Pulmonary Disease (COPD) is a prevalent respiratory disease that presents a high rate of underdiagnosis during onset and early stages. Studies have shown that in mild COPD patients, remodeling of the small airways occurs concurrently with morphological changes in the proximal airways. Despite this evidence, the geometrical study of the airway tree from computed tomography (CT) lung images remains underexplored due to poor representations and limited tools to characterize the airway structure. Methods: We perform a comprehensive morphometric study of the proximal airways based on geometrical measures associated with the different airway generations. To this end, we leverage the geometric flexibility of the Snakes IsoGeometric Analysis method to accurately represent and characterize the airway luminal surface and volume informed by CT images of the respiratory tree. Based on this framework, we study the airway geometry of smoking pre-COPD and mild COPD individuals. Results: Our results show a significant difference between groups in airway volume, length, luminal eccentricity, minimum radius, and surface-area-to-volume ratio in the most distal airways. Discussion: Our findings suggest a higher degree of airway narrowing and collapse in COPD patients when compared to pre-COPD patients. We envision that our work has the potential to deliver a comprehensive tool for assessing morphological changes in airway geometry that take place in the early stages of COPD.

7.
Front Physiol ; 13: 984286, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36267590

RESUMEN

Mechanical ventilation has been a vital treatment for Covid-19 patients with respiratory failure. Lungs assisted with mechanical ventilators present a wide variability in their response that strongly depends on air-tissue interactions, which motivates the creation of simulation tools to enhance the design of ventilatory protocols. In this work, we aim to create anatomical computational models of the lungs that predict clinically-relevant respiratory variables. To this end, we formulate a continuum poromechanical framework that seamlessly accounts for the air-tissue interaction in the lung parenchyma. Based on this formulation, we construct anatomical finite-element models of the human lungs from computed-tomography images. We simulate the 3D response of lungs connected to mechanical ventilation, from which we recover physiological parameters of high clinical relevance. In particular, we provide a framework to estimate respiratory-system compliance and resistance from continuum lung dynamic simulations. We further study our computational framework in the simulation of the supersyringe method to construct pressure-volume curves. In addition, we run these simulations using several state-of-the-art lung tissue models to understand how the choice of constitutive models impacts the whole-organ mechanical response. We show that the proposed lung model predicts physiological variables, such as airway pressure, flow and volume, that capture many distinctive features observed in mechanical ventilation and the supersyringe method. We further conclude that some constitutive lung tissue models may not adequately capture the physiological behavior of lungs, as measured in terms of lung respiratory-system compliance. Our findings constitute a proof of concept that finite-element poromechanical models of the lungs can be predictive of clinically-relevant variables in respiratory medicine.

8.
Front Cardiovasc Med ; 9: 885338, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35665243

RESUMEN

Background and Purpose: Prognostic models based on cardiovascular hemodynamic parameters may bring new information for an early assessment of patients with bicuspid aortic valve (BAV), playing a key role in reducing the long-term risk of cardiovascular events. This work quantifies several three-dimensional hemodynamic parameters in different patients with BAV and ranks their relationships with aortic diameter. Materials and Methods: Using 4D-flow CMR data of 74 patients with BAV (49 right-left and 25 right-non-coronary) and 48 healthy volunteers, aortic 3D maps of seventeen 17 different hemodynamic parameters were quantified along the thoracic aorta. Patients with BAV were divided into two morphotype categories, BAV-Non-AAoD (where we include 18 non-dilated patients and 7 root-dilated patients) and BAV-AAoD (where we include the 49 patients with dilatation of the ascending aorta). Differences between volunteers and patients were evaluated using MANOVA with Pillai's trace statistic, Mann-Whitney U test, ROC curves, and minimum redundancy maximum relevance algorithm. Spearman's correlation was used to correlate the dilation with each hemodynamic parameter. Results: The flow eccentricity, backward velocity, velocity angle, regurgitation fraction, circumferential wall shear stress, axial vorticity, and axial circulation allowed to discriminate between volunteers and patients with BAV, even in the absence of dilation. In patients with BAV, the diameter presented a strong correlation (> |+/-0.7|) with the forward velocity and velocity angle, and a good correlation (> |+/-0.5|) with regurgitation fraction, wall shear stress, wall shear stress axial, and vorticity, also for morphotypes and phenotypes, some of them are correlated with the diameter. The velocity angle proved to be an excellent biomarker in the differentiation between volunteers and patients with BAV, BAV morphotypes, and BAV phenotypes, with an area under the curve bigger than 0.90, and higher predictor important scores. Conclusions: Through the application of a novel 3D quantification method, hemodynamic parameters related to flow direction, such as flow eccentricity, velocity angle, and regurgitation fraction, presented the best relationships with a local diameter and effectively differentiated patients with BAV from healthy volunteers.

9.
Front Vet Sci ; 9: 839406, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35359684

RESUMEN

The present study describes the magnitude and spatial distribution of lung strain in healthy anesthetized, mechanically ventilated dogs with and without positive end-expiratory pressure (PEEP). Total lung strain (LSTOTAL) has a dynamic (LSDYNAMIC) and a static (LSSTATIC) component. Due to lung heterogeneity, global lung strain may not accurately represent regional total tissue lung strain (TSTOTAL), which may also be described by a regional dynamic (TSDYNAMIC) and static (TSSTATIC) component. Six healthy anesthetized beagles (12.4 ± 1.4 kg body weight) were placed in dorsal recumbency and ventilated with a tidal volume of 15 ml/kg, respiratory rate of 15 bpm, and zero end-expiratory pressure (ZEEP). Respiratory system mechanics and full thoracic end-expiratory and end-inspiratory CT scan images were obtained at ZEEP. Thereafter, a PEEP of 5 cmH2O was set and respiratory system mechanics measurements and end-expiratory and end-inspiratory images were repeated. Computed lung volumes from CT scans were used to evaluate the global LSTOTAL, LSDYNAMIC, and LSSTATIC during PEEP. During ZEEP, LSSTATIC was assumed zero; therefore, LSTOTAL was the same as LSDYNAMIC. Image segmentation was applied to CT images to obtain maps of regional TSTOTAL, TSDYNAMIC, and TSSTATIC during PEEP, and TSDYNAMIC during ZEEP. Compliance increased (p = 0.013) and driving pressure decreased (p = 0.043) during PEEP. PEEP increased the end-expiratory lung volume (p < 0.001) and significantly reduced global LSDYNAMIC (33.4 ± 6.4% during ZEEP, 24.0 ± 4.6% during PEEP, p = 0.032). LSSTATIC by PEEP was larger than the reduction in LSDYNAMIC; therefore, LSTOTAL at PEEP was larger than LSDYNAMIC at ZEEP (p = 0.005). There was marked topographic heterogeneity of regional strains. PEEP induced a significant reduction in TSDYNAMIC in all lung regions (p < 0.05). Similar to global findings, PEEP-induced TSSTATIC was larger than the reduction in TSDYNAMIC; therefore, PEEP-induced TSTOTAL was larger than TSDYNAMIC at ZEEP. In conclusion, PEEP reduced both global and regional estimates of dynamic strain, but induced a large static strain. Given that lung injury has been mostly associated with tidal deformation, limiting dynamic strain may be an important clinical target in healthy and diseased lungs, but this requires further study.

10.
Life (Basel) ; 12(3)2022 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-35330195

RESUMEN

This study aimed to evaluate if the changes in oxygen saturation levels at intercostal muscles (SmO2-m.intercostales) assessed by near-infrared spectroscopy (NIRS) using a wearable device could determine the respiratory compensation point (RCP) during exercise. Fifteen healthy competitive triathletes (eight males; 29 ± 6 years; height 167.6 ± 25.6 cm; weight 69.2 ± 9.4 kg; V˙O2-máx 58.4 ± 8.1 mL·kg−1·min−1) were evaluated in a cycle ergometer during the maximal oxygen-uptake test (V˙O2-máx), while lung ventilation (V˙E), power output (watts, W) and SmO2-m.intercostales were measured. RCP was determined by visual method (RCPvisual: changes at ventilatory equivalents (V˙E·V˙CO2−1, V˙E·V˙O2−1) and end-tidal respiratory pressure (PetO2, PetCO2) and NIRS method (RCPNIRS: breakpoint of fall in SmO2-m.intercostales). During exercise, SmO2-m.intercostales decreased continuously showing a higher decrease when V˙E increased abruptly. A good agreement between methods used to determine RCP was found (visual vs NIRS) at %V˙O2-máx, V˙O2, V˙E, and W (Bland-Altman test). Correlations were found to each parameters analyzed (r = 0.854; r = 0.865; r = 0.981; and r = 0,968; respectively. p < 0.001 in all variables, Pearson test), with no differences (p < 0.001 in all variables, Student's t-test) between methods used (RCPvisual and RCPNIRS). We concluded that changes at SmO2-m.intercostales measured by NIRS could adequately determine RCP in triathletes.

11.
Front Physiol ; 12: 755468, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34955878

RESUMEN

Alveolar architecture plays a fundamental role in the processes of ventilation and perfusion in the lung. Alterations in the alveolar surface area and alveolar cavity volume constitute the pathophysiological basis of chronic respiratory diseases such as pulmonary emphysema. Previous studies based on micro-computed tomography (micro-CT) of lung samples have allowed the geometrical study of acinar units. However, our current knowledge is based on the study of a few tissue samples in random locations of the lung that do not give an account of the spatial distributions of the alveolar architecture in the whole lung. In this work, we combine micro-CT imaging and computational geometry algorithms to study the regional distribution of key morphological parameters throughout the whole lung. To this end, 3D whole-lung images of Sprague-Dawley rats are acquired using high-resolution micro-CT imaging and analyzed to estimate porosity, alveolar surface density, and surface-to-volume ratio. We assess the effect of current gold-standard dehydration methods in the preparation of lung samples and propose a fixation protocol that includes the application of a methanol-PBS solution before dehydration. Our results show that regional porosity, alveolar surface density, and surface-to-volume ratio have a uniform distribution in normal lungs, which do not seem to be affected by gravitational effects. We further show that sample fixation based on ethanol baths for dehydration introduces shrinking and affects the acinar architecture in the subpleural regions. In contrast, preparations based on the proposed dehydration protocol effectively preserve the alveolar morphology.

12.
Front Vet Sci ; 8: 704863, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34660755

RESUMEN

We describe the respiratory mechanics and lung aeration in anesthetized obese dogs ventilated with tidal volumes (VT) based on ideal (VTi) vs. current (VTc) body weight. Six dogs with body condition scores ≥ 8/9 were included. End-expiratory respiratory mechanics and end-expiratory CT-scan were obtained at baseline for each dog. Thereafter, dogs were ventilated with VT 15 ml kg-1 based on VTi and VTc, applied randomly. Respiratory mechanics and CT-scan were repeated at end-inspiration during VTi and VTc. Data analyzed with linear mixed models and reported as mean ± SD or median [range]. Statistical significance p < 0.05. The elastance of the lung, chest wall and respiratory system indexed by ideal body weight (IBW) were positively correlated with body fat percentage, whereas the functional residual capacity indexed by IBW was negatively correlated with body fat percentage. At end-expiration, aeration (%) was: hyperaeration 0.03 [0.00-3.35], normoaeration 69.7 [44.6-82.2], hypoaeration 29.3 [13.6-49.4] and nonaeration (1.06% [0.37-6.02]). Next to the diaphragm, normoaeration dropped to 12 ± 11% and hypoaeration increased to 90 ± 8%. No differences in aeration between groups were found at end-inspiration. Airway driving pressure (cm H2O) was higher (p = 0.002) during VTc (9.8 ± 0.7) compared with VTi (7.6 ± 0.4). Lung strain was higher (p = 0.014) during VTc (55 ± 21%) than VTi (38 ± 10%). The stress index was higher (p = 0.012) during VTc (SI = 1.07 [0.14]) compared with VTi (SI = 0.93 [0.18]). This study indicates that body fat percentage influences the magnitude of lung, chest wall, and total respiratory system elastance and resistance, as well as functional residual capacity. Further, these results indicate that obese dogs have extensive areas of hypoaerated lungs, especially in caudodorsal regions. Finally, lung strain and airway driving pressure, surrogates of lung deformation, are higher during VTc than during VTi, suggesting that in obese anesthetized dogs, ventilation protocols based on IBW may be advantageous.

13.
Acta Anaesthesiol Scand ; 65(2): 228-235, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33037607

RESUMEN

RATIONALE: Cyclic strain may be a determinant of ventilator-induced lung injury. The standard for strain assessment is the computed tomography (CT), which does not allow continuous monitoring and exposes to radiation. Electrical impedance tomography (EIT) is able to monitor changes in regional lung ventilation. In addition, there is a correlation between mechanical deformation of materials and detectable changes in its electrical impedance, making EIT a potential surrogate for cyclic lung strain measured by CT (StrainCT ). OBJECTIVES: To compare the global StrainCT with the change in electrical impedance (ΔZ). METHODS: Acute respiratory distress syndrome patients under mechanical ventilation (VT 6 mL/kg ideal body weight with positive end-expiratory pressure 5 [PEEP 5] and best PEEP according to EIT) underwent whole-lung CT at end-inspiration and end-expiration. Biomechanical analysis was used to construct 3D maps and determine StrainCT at different levels of PEEP. CT and EIT acquisitions were performed simultaneously. Multilevel analysis was employed to determine the causal association between StrainCT and ΔZ. Linear regression models were used to predict the change in lung StrainCT between different PEEP levels based on the change in ΔZ. MAIN RESULTS: StrainCT was positively and independently associated with ΔZ at global level (P < .01). Furthermore, the change in StrainCT (between PEEP 5 and Best PEEP) was accurately predicted by the change in ΔZ (R2 0.855, P < .001 at global level) with a high agreement between predicted and measured StrainCT . CONCLUSIONS: The change in electrical impedance may provide a noninvasive assessment of global cyclic strain, without radiation at bedside.


Asunto(s)
Pulmón , Tomografía , Impedancia Eléctrica , Humanos , Pulmón/diagnóstico por imagen , Respiración con Presión Positiva , Tomografía Computarizada por Rayos X
14.
Ann Intensive Care ; 10(1): 107, 2020 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-32761387

RESUMEN

BACKGROUND: Protective mechanical ventilation (MV) aims at limiting global lung deformation and has been associated with better clinical outcomes in acute respiratory distress syndrome (ARDS) patients. In ARDS lungs without MV support, the mechanisms and evolution of lung tissue deformation remain understudied. In this work, we quantify the progression and heterogeneity of regional strain in injured lungs under spontaneous breathing and under MV. METHODS: Lung injury was induced by lung lavage in murine subjects, followed by 3 h of spontaneous breathing (SB-group) or 3 h of low Vt mechanical ventilation (MV-group). Micro-CT images were acquired in all subjects at the beginning and at the end of the ventilation stage following induction of lung injury. Regional strain, strain progression and strain heterogeneity were computed from image-based biomechanical analysis. Three-dimensional regional strain maps were constructed, from which a region-of-interest (ROI) analysis was performed for the regional strain, the strain progression, and the strain heterogeneity. RESULTS: After 3 h of ventilation, regional strain levels were significantly higher in 43.7% of the ROIs in the SB-group. Significant increase in regional strain was found in 1.2% of the ROIs in the MV-group. Progression of regional strain was found in 100% of the ROIs in the SB-group, whereas the MV-group displayed strain progression in 1.2% of the ROIs. Progression in regional strain heterogeneity was found in 23.4% of the ROIs in the SB-group, while the MV-group resulted in 4.7% of the ROIs showing significant changes. Deformation progression is concurrent with an increase of non-aerated compartment in SB-group (from 13.3% ± 1.6% to 37.5% ± 3.1%), being higher in ventral regions of the lung. CONCLUSIONS: Spontaneous breathing in lung injury promotes regional strain and strain heterogeneity progression. In contrast, low Vt MV prevents regional strain and heterogeneity progression in injured lungs.

15.
Crit Care ; 24(1): 494, 2020 08 10.
Artículo en Inglés | MEDLINE | ID: mdl-32778136

RESUMEN

Deterioration of lung function during the first week of COVID-19 has been observed when patients remain with insufficient respiratory support. Patient self-inflicted lung injury (P-SILI) is theorized as the responsible, but there is not robust experimental and clinical data to support it. Given the limited understanding of P-SILI, we describe the physiological basis of P-SILI and we show experimental data to comprehend the role of regional strain and heterogeneity in lung injury due to increased work of breathing.In addition, we discuss the current approach to respiratory support for COVID-19 under this point of view.


Asunto(s)
Infecciones por Coronavirus/fisiopatología , Progresión de la Enfermedad , Lesión Pulmonar/fisiopatología , Neumonía Viral/fisiopatología , Trabajo Respiratorio/fisiología , COVID-19 , Infecciones por Coronavirus/terapia , Cuidados Críticos , Humanos , Lesión Pulmonar/etiología , Pandemias , Neumonía Viral/terapia , Ensayos Clínicos Controlados Aleatorios como Asunto , Respiración Artificial
16.
Sci Rep ; 10(1): 12990, 2020 07 31.
Artículo en Inglés | MEDLINE | ID: mdl-32737400

RESUMEN

Biomaterial injection is a novel therapy to treat ischemic heart failure (HF) that has shown to reduce remodeling and restore cardiac function in recent preclinical studies. While the effect of biomaterial injection in reducing mechanical wall stress has been recently demonstrated, the influence of biomaterials on the electrical behavior of treated hearts has not been elucidated. In this work, we developed computational models of swine hearts to study the electrophysiological vulnerability associated with biomaterial injection therapy. The propagation of action potentials on realistic biventricular geometries was simulated by numerically solving the monodomain electrophysiology equations on anatomically-detailed models of normal, HF untreated, and HF treated hearts. Heart geometries were constructed from high-resolution magnetic resonance images (MRI) where the healthy, peri-infarcted, infarcted and gel regions were identified, and the orientation of cardiac fibers was informed from diffusion-tensor MRI. Regional restitution properties in each case were evaluated by constructing a probability density function of the action potential duration (APD) at different cycle lengths. A comparative analysis of the ventricular fibrillation (VF) dynamics for every heart was carried out by measuring the number of filaments formed after wave braking. Our results suggest that biomaterial injection therapy does not affect the regional dispersion of repolarization when comparing untreated and treated failing hearts. Further, we found that the treated failing heart is more prone to sustain VF than the normal heart, and is at least as susceptible to sustained VF as the untreated failing heart. Moreover, we show that the main features of VF dynamics in a treated failing heart are not affected by the level of electrical conductivity of the biogel injectates. This work represents a novel proof-of-concept study demonstrating the feasibility of computer simulations of the heart in understanding the arrhythmic behavior in novel therapies for HF.


Asunto(s)
Materiales Biocompatibles/farmacología , Simulación por Computador , Sistema de Conducción Cardíaco/fisiopatología , Insuficiencia Cardíaca , Modelos Cardiovasculares , Fibrilación Ventricular , Animales , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/fisiopatología , Humanos , Porcinos , Fibrilación Ventricular/tratamiento farmacológico , Fibrilación Ventricular/fisiopatología
17.
PLoS Comput Biol ; 16(2): e1007232, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-32097410

RESUMEN

Gap junctions are key mediators of intercellular communication in cardiac tissue, and their function is vital to sustaining normal cardiac electrical activity. Conduction through gap junctions strongly depends on the hemichannel arrangement and transjunctional voltage, rendering the intercellular conductance highly non-Ohmic, particularly under steady-state regimes of conduction. Despite this marked non-linear behavior, current tissue-level models of cardiac conduction are rooted in the assumption that gap-junctions conductance is constant (Ohmic), which results in inaccurate predictions of electrical propagation, particularly in the low junctional-coupling regime observed under pathological conditions. In this work, we present a novel non-Ohmic homogenization model (NOHM) of cardiac conduction that is suitable to tissue-scale simulations. Using non-linear homogenization theory, we develop a conductivity model that seamlessly upscales the voltage-dependent conductance of gap junctions, without the need of explicitly modeling gap junctions. The NOHM model allows for the simulation of electrical propagation in tissue-level cardiac domains that accurately resemble that of cell-based microscopic models for a wide range of junctional coupling scenarios, recovering key conduction features at a fraction of the computational complexity. A unique feature of the NOHM model is the possibility of upscaling the response of non-symmetric gap-junction conductance distributions, which result in conduction velocities that strongly depend on the direction of propagation, thus allowing to model the normal and retrograde conduction observed in certain regions of the heart. We envision that the NOHM model will enable organ-level simulations that are informed by sub- and inter-cellular mechanisms, delivering an accurate and predictive in-silico tool for understanding the heart function. Codes are available for download at https://github.com/dehurtado/NonOhmicConduction.


Asunto(s)
Conductividad Eléctrica , Técnicas Electrofisiológicas Cardíacas , Uniones Comunicantes/fisiología , Corazón/fisiología , Animales , Modelos Cardiovasculares
18.
Arterioscler Thromb Vasc Biol ; 40(1): e10-e20, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31801375

RESUMEN

OBJECTIVE: To assess the relationship between regional wall shear stress (WSS) and oscillatory shear index (OSI) and aortic dilation in patients with bicuspid aortic valve (BAV). Approach and Results: Forty-six consecutive patients with BAV (63% with right-left-coronary-cusp fusion, aortic diameter ≤ 45 mm and no severe valvular disease) and 44 healthy volunteers were studied by time-resolved 3-dimensional phase-contrast magnetic resonance imaging. WSS and OSI were quantified at different levels of the ascending aorta and the aortic arch, and regional WSS and OSI maps were obtained. Seventy percent of BAV had ascending aorta dilation. Compared with healthy volunteers, patients with BAV had increased WSS and decreased OSI in most of the ascending aorta and the aortic arch. In both BAV and healthy volunteers, regions of high WSS matched regions of low OSI and vice versa. No regions of both low WSS and high OSI were identified in BAV compared with healthy volunteers. Patients with BAV with dilated compared with nondilated aorta presented low and oscillatory WSS in the aortic arch, but not in the ascending aorta where dilation is more prevalent. Furthermore, no regions of concomitant low WSS and high OSI were identified when BAV were compared according to leaflet fusion pattern, despite the well-known differences in regional dilation prevalence. CONCLUSIONS: Regions with low WSS and high OSI do not match those with the highest prevalence of dilation in patients with BAV, thus providing no evidence to support the low and oscillatory shear stress theory in the pathogenesis of proximal aorta dilation in the presence of BAV.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/diagnóstico , Imagenología Tridimensional , Imagen por Resonancia Cinemagnética/métodos , Flujo Sanguíneo Regional/fisiología , Resistencia al Corte/fisiología , Adulto , Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/etiología , Aneurisma de la Aorta Torácica/fisiopatología , Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Estrés Mecánico
19.
J Clin Monit Comput ; 34(2): 223-231, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31161533

RESUMEN

Respiratory rate (RR) is a key vital sign that has been traditionally employed in the clinical assessment of patients and in the prevention of respiratory compromise. Despite its relevance, current practice for monitoring RR in non-intubated patients strongly relies on visual counting, which delivers an intermittent and error-prone assessment of the respiratory status. Here, we present a novel non-invasive respiratory monitor that continuously measures the RR in human subjects. The respiratory activity of the user is inferred by sensing the thermal transfer between the breathing airflow and a temperature sensor placed between the nose and the mouth. The performance of the respiratory monitor is assessed through respiratory experiments performed on healthy subjects. Under spontaneous breathing, the mean RR difference between our respiratory monitor and visual counting was 0.4 breaths per minute (BPM), with a 95% confidence interval equal to [- 0.5, 1.3] BPM. The robustness of the respiratory sensor to the position is assessed by studying the signal-to-noise ratio in different locations on the upper lip, displaying a markedly better performance than traditional thermal sensors used for respiratory airflow measurements.


Asunto(s)
Monitoreo Fisiológico/instrumentación , Frecuencia Respiratoria , Adolescente , Adulto , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/estadística & datos numéricos , Respiración , Relación Señal-Ruido , Temperatura , Adulto Joven
20.
BMJ Open Respir Res ; 6(1): e000423, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31749967

RESUMEN

Introduction: Breathing produces a phenomenon of cyclic deformation throughout life. Biomechanically, deformation of the lung is measured as strain. Regional strain recently started to be recognised as a tool in the study of lung pathophysiology, but regional lung strain has not been studied in healthy subjects breathing spontaneously without voluntary or pharmacological control of ventilation. Our aim is to generate three-dimensional (3D) regional strain and heterogeneity maps of healthy rat lungs and describe their changes over time. Methods: Micro-CT and image-based biomechanical analysis by finite element approach were carried out in six anaesthetised rats under spontaneous breathing in two different states, at the beginning of the experiment and after 3 hours of observation. 3D regional strain maps were constructed and divided into 10 isovolumetric region-of-interest (ROI) in three directions (apex to base, dorsal to ventral and costal to mediastinal), allowing to regionally analyse the volumetric strain, the strain progression and the strain heterogeneity. To describe in depth these parameters, and systematise their report, we defined regional strain heterogeneity index [1+strain SD ROI(x)]/[1+strain mean ROI(x)] and regional strain progression index [ROI(x)-mean of final strain/ROI(x)-mean of initial strain]. Results: We were able to generate 3D regional strain maps of the lung in subjects without respiratory support, showing significant differences among the three analysed axes. We observed a significantly lower regional volumetric strain in the apex sector compared with the base, with no significant anatomical systematic differences in the other directions. This heterogeneity could not be identified with physiological or standard CT methods. There was no progression of the analysed regional volumetric strain when the two time-points were compared. Discussion: It is possible to map the regional volumetric strain in the lung for healthy subjects during spontaneous breathing. Regional strain heterogeneity and changes over time can be measured using a CT image-based numerical analysis applying a finite element approach. These results support that healthy lung might have significant regional strain and its spatial distribution is highly heterogeneous. This protocol for CT image acquisition and analysis could be a useful tool for helping to understand the mechanobiology of the lung in many diseases.


Asunto(s)
Imagenología Tridimensional , Pulmón/diagnóstico por imagen , Respiración , Animales , Fenómenos Biomecánicos , Estudios de Factibilidad , Pulmón/fisiología , Modelos Animales , Ratas , Ratas Sprague-Dawley , Microtomografía por Rayos X