Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Hernia ; 10(2): 131-42, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16404491

RESUMEN

A counterfeit version of the Ethicon Prolene polypropylene mesh was distributed to hospitals and clinics and unintentionally implanted into patients undergoing tension-free hernia repair. On December 19, 2003, the Food and Drug Administration (FDA) issued a public health web notification indicating that the counterfeit mesh was not sterile or safe to use. To develop safety recommendations for patients with the counterfeit mesh implant, we compared the counterfeit's structural, physical, chemical and mechanical properties with polypropylene meshes previously cleared by FDA. The mesh fibers for all the products tested were found to have similar chemical and physical properties. The mechanical properties were directly related to the knitted structure (loop size, repeat distance, fabric tightness) and the porosity. Extracts from the counterfeit mesh passed cytotoxicity screening tests. The FDA further recommended that if the mesh had been inadvertently implanted, then those patients should be monitored as would be the practice for any patient with an implanted surgical mesh.


Asunto(s)
Herniorrafia , Polipropilenos/normas , Mallas Quirúrgicas/normas , Humanos , Esterilización/normas , Estados Unidos , United States Food and Drug Administration
2.
Toxicol Ind Health ; 20(1-5): 41-50, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15807407

RESUMEN

The distribution of 14C-bisphenol A (BPA) in plasma and neuroendocrine organs was determined in Fischer 344 female rats following three oral doses (0.1, 10 or 100mg/kg). Plasma and tissue maximum concentrations (Cmax) were reached within 15-30 min of dosing. Plasma areas-under-the-curve (AUC) ranged from 0.06 to 53.9 microg-h/mL. The AUCs of the pituitary gland and uterus/gonads were 16-21% higher than that of plasma. The AUCs of hypothalamus and the rest of the brain were 43.7% and 77% of the plasma AUCs, respectively. In the brain tissue, the exposure increased linearly with the oral dose, as the dose was increased from 0.1 to 10 and 100 mg/kg; the exposure in the brain relative to the plasma increased by factors of 1, 1.19 and 1.24. This indicates that the brain barrier systems do not limit the access of the lipophilic BPA to the brain. The increases of the uterus/gonads relative to the plasma were 1, 1.07 and 1.04. Tissue partitioning was also examined in vitro by the uptake of 14C-BPA. The BPA tissue/blood partition coefficients were as follows: heart, 7.5; liver, 6.1; kidney, 6.4; fat, 3.6; muscle, 2.6; breast, 3.6; ovaries, 9.1; uterus, 5.9; stomach, 5.1; and small intestine, 6.7. The tissue/cerebrospinal fluid partition coefficients were as follows: pituitary gland, 12.8; brain stem, 6.1; cerebellum, 6.4; hippocampus, 7.1; hypothalamus, 6.1; frontal cortex, 4.9; and caudate nucleus, 6.8.


Asunto(s)
Estrógenos no Esteroides/farmacocinética , Sistemas Neurosecretores/metabolismo , Fenoles/farmacocinética , Administración Oral , Animales , Área Bajo la Curva , Compuestos de Bencidrilo , Relación Dosis-Respuesta a Droga , Femenino , Ratas , Ratas Endogámicas F344 , Distribución Tisular
3.
Environ Health Perspect ; 109(11): 1095-101, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11712992

RESUMEN

We developed a physiologically based pharmacokinetic (PBPK) model to predict the target organ doses of octamethylcyclotetrasiloxane (D(4)) after intravenous (IV), inhalation, or implantation exposures. The model used (14)C-D(4) IV disposition data in rats to estimate tissue distribution coefficients, metabolism, and excretion parameters. We validated the model by comparing the predicted blood and tissues concentrations of D(4) after inhalation to experimental results in both rats and humans. We then used the model to simulate D(4) kinetics after single and/or repeated D(4) exposures in rats and humans. The model predicted bioaccumulation of D(4) in fatty tissues (e.g., breast), especially in women. Because of its high lipid solubility (Log P(oct/water) = 5.1), D(4) persisted in fat with a half life of 11.1 days after inhalation and 18.2 days after breast implant exposure. Metabolism and excretion remained constant with repeated exposures, larger doses, and/or different routes of exposure. The accumulation of D(4) in fatty tissues should play an important role in the risk assessment of D(4) especially in women exposed daily to multiple personal care products and silicone breast implants.


Asunto(s)
Adyuvantes Inmunológicos/farmacocinética , Modelos Teóricos , Siloxanos/farmacocinética , Tejido Adiposo/química , Adyuvantes Inmunológicos/administración & dosificación , Animales , Disponibilidad Biológica , Implantes de Mama , Cosméticos/química , Exposición a Riesgos Ambientales , Humanos , Infusiones Intravenosas , Exposición por Inhalación , Cinética , Ratas , Medición de Riesgo , Factores Sexuales , Siliconas/administración & dosificación , Siliconas/efectos adversos , Siloxanos/administración & dosificación , Distribución Tisular
4.
ASAIO J ; 47(5): 522-7, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11575830

RESUMEN

A previous investigation by our laboratory linked cellulose acetate degradation with adverse health effects in hemodialysis patients. To establish the accumulation of degradation products with time, a Monte Carlo model of degradation kinetics was developed. The model tracks changes in a population of molecules representative of the dialyzer membrane during the degradation process. The degradation calculation is a two step process: First, the model uses a random number to select an individual polymer molecule out of the population, and then a second random number is used to identify a site on the selected molecule for the degradation reaction to occur. After the reaction calculation, the resulting degraded molecules are redistributed into the population. The course of the reaction is determined by recalculating the molecular weight averages in the changing population as the calculations proceed. The model was validated using gel permeation chromatography molecular weight results and total acetyl content measurements on dialyzers stored up to 13.3 years after manufacture. It was found that the degradation reactions can be accurately modeled as random events and that the chain scissions and deacetylation events occur at constant rates. The shelf life of these devices was estimated using the model predictions and animal test results.


Asunto(s)
Celulosa , Celulosa/análogos & derivados , Riñones Artificiales , Membranas Artificiales , Celulosa/efectos adversos , Celulosa/química , Estabilidad de Medicamentos , Humanos , Técnicas In Vitro , Riñones Artificiales/efectos adversos , Modelos Químicos , Peso Molecular , Método de Montecarlo , Seguridad , Factores de Tiempo
5.
J Biomed Mater Res ; 53(5): 449-56, 2000 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10984691

RESUMEN

In September 1996, seven patients at Hospital A suffered conjunctivitis, hearing loss, diminished vision, and headaches 7-24 h after hemodialysis treatment. Eleven-year-old dialysis modules were identified as a common link between these patients. Degradation of the cellulose acetate (CA) material was identified as the cause of this incident. Degradation products were characterized from retrieved CA dialysis membranes. A series of synthesized CA degradation products was tested in vitro to assess toxicity. Based on the toxicity of the material preparations to the cells, animal tests were performed on selected CA degradation extracts and compared to extracts from actual dialysis membranes. Rabbits were IV-injected with extracts from a 13-year-old dialyzer, synthesized model compounds, and compared to controls. Ophthamological evaluation of the rabbits showed eye injury (iritis/ciliary flush) when the animals were treated with the old dialyzer or synthesized model compounds. Isolation and characterization of a toxic fraction from both of these extracts strongly indicated that oxidative stress at some point in the storage or manufacture of CA dialyzers created degradation products that reproduced some of the patient symptoms identified at Hospital A.


Asunto(s)
Celulosa/análogos & derivados , Falla de Equipo , Diálisis Renal/instrumentación , Animales , Materiales Biocompatibles/química , Materiales Biocompatibles/toxicidad , Supervivencia Celular/efectos de los fármacos , Celulosa/química , Celulosa/toxicidad , Conjuntivitis/etiología , Sordera/etiología , Femenino , Cefalea/etiología , Humanos , Células Jurkat , Membranas Artificiales , Conejos , Diálisis Renal/normas , Trastornos de la Visión/etiología
6.
JAMA ; 283(16): 2128-34, 2000 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-10791505

RESUMEN

CONTEXT: A recent event in which 7 patients at 1 hospital developed decreased vision and hearing, conjunctivitis, headache, and other severe neurologic symptoms 7 to 24 hours after hemodialysis drew attention to the issue of the long-term integrity of dialysis machines and materials. OBJECTIVE: To determine the cause of the adverse reactions that occurred during this event. DESIGN, PATIENTS, AND SETTING: Retrospective cohort study of all 9 patients who received hemodialysis at hospital A on September 18, 1996, the day of the outbreak. A case-patient was defined as any hospital A patient with acute onset of decreased vision and hearing and conjunctivitis after dialysis on that day. Non-case-patients were all others who underwent dialysis at hospital A on that day but did not develop adverse reactions. In an attempt to reproduce the conditions of the event, cellulose acetate dialysis membranes of various ages were retrieved from other sources and tested for physical and chemical degradation, and degradation products were identified, characterized, and injected intravenously into rabbits. MAIN OUTCOME MEASURES: Clinical signs and symptoms, time to resolution of symptoms, mortality, and dialyzer type and age, for case- vs non-case-patients. RESULTS: Seven of the 9 patients met the case definition. In addition to diminished vision and hearing, conjunctivitis, and headache, some case-patients had blood leak alarm activation (n=6), confusion/lethargy (n=5), corneal opacification (n=4), cardiac arrest (n=2), or other neurologic signs and symptoms. One case-patient died during hospitalization after the event; 5 of 7 case-patients died within 13 months. Resolution of signs and symptoms varied but persisted more than 3 years or until death in 3 of the 6 patients who survived hospitalization. All case-patients but no non-case-patients were exposed to 11.5-year-old cellulose acetate dialyzers (all of these dialyzers were discarded by the hospital before our investigation). Laboratory investigation of field-retrieved 0- to 13.6-year-old dialyzers of similar type indicated significant chemical degradation in the older membranes. In vivo injection of extracts of membrane degradation products produced iritis and hemorrhages in rabbits' eyes. CONCLUSIONS: Severe patient injury was associated with exposure to aged cellulose acetate membranes of dialyzers, allowing cellulose acetate degradation products to enter the blood. Clinicians should be aware that aged cellulose acetate membranes may cause severe adverse reactions.


Asunto(s)
Trastornos de la Audición/etiología , Diálisis Renal/efectos adversos , Diálisis Renal/instrumentación , Trastornos de la Visión/etiología , Enfermedad Aguda , Adulto , Anciano , Conjuntivitis/etiología , Brotes de Enfermedades , Falla de Equipo , Femenino , Cefalea/etiología , Trastornos de la Audición/epidemiología , Hospitales , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Trastornos de la Visión/epidemiología
7.
J Biomed Mater Res ; 53(3): 276-86, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10813768

RESUMEN

4, 4'-Methylenedianiline (MDA) is a hydrolysis degradation product that can be released from polyurethanes commonly used in medical device applications. MDA is mutagenic and carcinogenic in animals. In humans, it is hepatotoxic, a known contact and respiratory allergen, and a suspected carcinogen. A physiologically based pharmacokinetic (PBPK) model was developed to estimate the absorption, distribution, metabolism, and excretion of MDA in patients exposed to MDA leached from the potting materials of hemodialyzers. A worst-case reuse situation and a single use case were investigated. The PBPK model included five tissue compartments: liver, kidney, gastrointestinal tract, slowly perfused tissues, and richly perfused tissues. Physiological and chemical parameters of a healthy individual used in the model were obtained from the literature. The model was calibrated using previously published kinetic studies of IV administered doses of (14) C-MDA to rats. The model was validated using independent data published for MDA-exposed workers. The PBPK results indicated that dialysis patients who are exposed to MDA released from dialyzers (new or reused) could accumulate low levels of MDA and metabolites (total MDA) over time.


Asunto(s)
Compuestos de Anilina/farmacocinética , Materiales Biocompatibles/farmacocinética , Carcinógenos/farmacocinética , Equipos y Suministros/efectos adversos , Poliuretanos/metabolismo , Animales , Humanos , Modelos Biológicos , Poliuretanos/farmacocinética , Ratas
8.
J Ultrasound Med ; 18(1): 1-11, 1999 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-9952073

RESUMEN

A physiologically based pharmacokinetic model was developed to evaluate the kinetics of one of the newest sonographic contrast agents available, FS069 or Optison. This material consists of octafluoropropane gas encapsulated in proteinaceous microspheres, injected intravenously for use as a myocardial contrast agent in humans. This model has six compartments: two lung compartments (alveolar and dead volume), and compartments for the heart, slowly perfused tissue, richly perfused tissue, and gastrointestinal tract. The model was developed to determine the distribution and excretion of the octafluoropropane in the body. Despite the high affinity of octafluoropropane for tissue, the model predicted that nearly 100% of the material would be exhaled from the lungs within 6 min. The model verified the results of a phase I clinical trial with 10 healthy subjects. Ventilation rate was found to play a critical role in the complete excretion of this contrast agent. The physiologically based pharmacokinetic model was a useful tool for evaluating the safety of FS069. This model can be used a basis for developing similar models for other types of contrast agents.


Asunto(s)
Albúminas/farmacocinética , Medios de Contraste/farmacocinética , Fluorocarburos/farmacocinética , Adulto , Cromatografía de Gases , Ecocardiografía , Femenino , Humanos , Inyecciones Intravenosas , Masculino , Microesferas , Modelos Biológicos
9.
Environ Health Perspect ; 106(7): 393-400, 1998 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-9637796

RESUMEN

Physiologically based pharmacokinetic (PBPK) modeling was used to assess the low-dose exposure of patients to the carcinogen 2, 4-toluenediamine (2,4-TDA) released from the degradation of the polyester urethane foam (PU) used in Meme silicone breast implants. The tissues are represented as five compartments: liver, kidney, gastrointestinal tract, slowly perfused tissues (e.g., fat), and richly perfused tissues (e.g., muscle). The PBPK model was fitted to the plasma and urine concentrations of 2,4-TDA and its metabolite 4-AAT (4-N-acetyl-2-amino toluene) in rats given low doses of 2, 4-TDA intravenously and subcutaneously. The rat model was extrapolated to simulate oral and implant routes in rats. After adjusting for human physiological parameters, the model was then used to predict the bioavailability of 2,4-TDA released from a typical 4.87-g polyester urethane foam implant found in a patient who weighed 58 kg with the Meme and had the breast implant for 10 years. A quantitative risk assessment for 2,4-TDA was performed and the polyester urethane foam did present an unreasonable risk to health for the patient.


Asunto(s)
Implantes de Mama/efectos adversos , Carcinógenos/farmacocinética , Fenilendiaminas/farmacocinética , Poliuretanos/química , Algoritmos , Animales , Carcinógenos/química , Femenino , Humanos , Inyecciones Intravenosas , Inyecciones Subcutáneas , Modelos Biológicos , Fenilendiaminas/química , Ratas , Distribución Tisular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA