1.
Otol Neurotol ; 45(3): e234-e240, 2024 Mar 01.
Article En | MEDLINE | ID: mdl-38238926

HYPOTHESIS: Measurements of the cochlear duct length (CDL) are dependent on the resolution of the imaging dataset. BACKGROUND: Previous research has shown highly precise cochlear measurements using 3D-curved multiplanar reconstruction (MPR) and flat-panel volume computed tomography (fpVCT). Thus far, however, there has been no systematic evaluation of the imaging dataset resolution required for optimal CDL measurement. Therefore, the aim of this study was to evaluate the dependence of CDL measurement on the resolution of the imaging dataset to establish a benchmark for future CDL measurements. METHODS: fpVCT scans of 10 human petrous bone specimens were performed. CDL was measured using 3D-curved MPR with secondary reconstruction of the fpVCT scans (fpVCT SECO ) and increasing resolution from 466 to 99 µm. In addition, intraobserver variability was evaluated. A best-fit function for calculation of the CDL was developed to provide a valid tool when there are no measurements done with high-resolution imaging datasets. RESULTS: Comparison of different imaging resolution settings showed significant differences for CDL measurement in most of the tested groups ( p < 0.05), except for the two groups with the highest resolution. Imaging datasets with a resolution lower than 200 µm showed lower intraobserver variability than the other resolution settings, although there were no clinically unacceptable errors with respect to the Bland-Altman plots. The developed best-fit function showed high accuracy for CDL calculation using resolution imaging datasets of 300 µm or lower. CONCLUSION: 3D-curved MPR in fpVCT with a resolution of the imaging dataset of 200 µm or higher revealed the most precise CDL measurement. There was no benefit of using a resolution higher than 200 µm with regard to the accuracy of the CDL measurement.


Cochlear Implantation , Cochlear Implants , Humans , Tomography, X-Ray Computed/methods , Cochlear Duct/surgery , Cochlea/diagnostic imaging , Cochlea/surgery , Cone-Beam Computed Tomography , Petrous Bone/diagnostic imaging , Petrous Bone/surgery , Cochlear Implantation/methods
2.
Front Surg ; 9: 747517, 2022.
Article En | MEDLINE | ID: mdl-35187054

Improved radiological examinations with newly developed 3D models may increase understanding of Meniere's disease (MD). The morphology and course of the vestibular aqueduct (VA) in the temporal bone might be related to the severity of MD. The presented study explored, if the VA of MD and non-MD patients can be grouped relative to its angle to the semicircular canals (SCC) and length using a 3D model. Scans of temporal bone specimens (TBS) were performed using micro-CT and micro flat panel volume computed tomography (mfpVCT). Furthermore, scans were carried out in patients and TBS by computed tomography (CT). The angle between the VA and the three SCC, as well as the length of the VA were measured. From these data, a 3D model was constructed to develop the vestibular aqueduct score (VAS). Using different imaging modalities it was demonstrated that angle measurements of the VA are reliable and can be effectively used for detailed diagnostic investigation. To test the clinical relevance, the VAS was applied on MD and on non-MD patients. Length and angle values from MD patients differed from non-MD patients. In MD patients, significantly higher numbers of VAs could be assigned to a distinct group of the VAS. In addition, it was tested, whether the outcome of a treatment option for MD can be correlated to the VAS.

3.
Cochlear Implants Int ; 23(1): 32-42, 2022 Jan.
Article En | MEDLINE | ID: mdl-34519256

OBJECTIVE: There is still a lack in precise postoperative evaluation of the cochlea because of strong artifacts. This study aimed to improve accuracy of postoperative two-turn (2TL) and cochlear duct length (CDL) measurements by applying flat-panel volume computed tomography (fpVCT), secondary reconstruction (fpVCTSECO) and three-dimensional curved multiplanar reconstruction. METHODS: First, 10 temporal bone specimens with or without electrode were measured in multi-slice computed tomography (MSCT), fpVCT and fpVCTSECO and compared to high-resolution micro-CT scans. Later, pre- and postoperative scans of 10 patients were analyzed in a clinical setting. RESULTS: Concerning 2TL, no statistically significant difference was observed between implanted fpVCTSECO and nonimplanted micro-CT in 10 temporal bone specimens. In contrast, there was a significant discrepancy for CDL (difference: -0.7 mm, P = 0.004). Nevertheless, there were no clinically unacceptable errors (±1.5 mm). These results could be confirmed in a clinical setting. Using fpVCTSECO, CDL was slightly underestimated postoperatively (difference: -0.5 mm, P = 0.002) but without any clinically unacceptable errors. CONCLUSION: fpVCTSECO can be successfully applied for a precise measurement of the cochlear lengths pre- and postoperatively. However, users must be aware of a slight systematic underestimation of CDL postoperatively. These results may help to refine electrode selection and frequency mapping.


Cochlear Implantation , Cochlear Implants , Cochlea/diagnostic imaging , Cochlea/surgery , Cochlear Duct/surgery , Cochlear Implantation/methods , Cone-Beam Computed Tomography , Humans , Temporal Bone/diagnostic imaging , Temporal Bone/surgery
4.
Eur Arch Otorhinolaryngol ; 279(5): 2309-2319, 2022 May.
Article En | MEDLINE | ID: mdl-34101009

PURPOSE: For further improvements in cochlear implantation, the measurement of the cochlear duct length (CDL) and the determination of the electrode contact position (ECP) are increasingly in the focus of clinical research. Usually, these items were investigated by multislice computed tomography (MSCT). The determination of ECP was only possible by research programs so far. Flat-panel volume computed tomography (fpVCT) and its secondary reconstructions (fpVCTSECO) allow for high spatial resolution for the visualization of the temporal bone structures. Using a newly developed surgical planning software that enables the evaluation of CDL and the determination of postoperative ECP, this study aimed to investigate the combination of fpVCT and otological planning software to improve the implementation of an anatomically based cochlear implantation. METHODS: Cochlear measurements were performed utilizing surgical planning software in imaging data (MSCT, fpVCT and fpVCTSECO) of patients with and without implanted electrodes. RESULTS: Measurement of the CDL by the use of an otological planning software was highly reliable using fpVCTSECO with a lower variance between the respective measurements compared to MSCT. The determination of the inter-electrode-distance (IED) between the ECP was improved in fpVCTSECO compared to MSCT. CONCLUSION: The combination of fpVCTSECO and otological planning software permits a simplified and more reliable analysis of the cochlea in the pre- and postoperative setting. The combination of both systems will enable further progress in the development of an anatomically based cochlear implantation.


Cochlear Implantation , Cochlear Implants , Cochlea/diagnostic imaging , Cochlea/surgery , Cochlear Duct , Cochlear Implantation/methods , Cone-Beam Computed Tomography , Humans , Software
5.
OTO Open ; 5(3): 2473974X211045312, 2021.
Article En | MEDLINE | ID: mdl-34595367

OBJECTIVE: Growing interest in measuring the cochlear duct length (CDL) has emerged, since it can influence the selection of cochlear implant electrodes. Currently the measurements are performed with ionized radiation imaging. Only a few studies have explored CDL measurements in magnetic resonance imaging (MRI). Therefore, the presented study aims to fill this gap by estimating CDL in MRI and comparing it with multislice computed tomography (CT). STUDY DESIGN: Retrospective data analyses of 42 cochleae. SETTING: Tertiary care medical center. METHODS: Diameter (A value) and width (B value) of the cochlea were measured in HOROS software. The CDL and the 2-turn length were determined by the elliptic circular approximation (ECA). In addition, the CDL, the 2-turn length, and the angular length were determined via HOROS software by the multiplanar reconstruction (MPR) method. RESULTS: CDL values were significantly shorter in MRI by MPR (d = 1.38 mm, P < .001) but not by ECA. Similar 2-turn length measurements were significantly lower in MRI by MPR (d = 1.67 mm) and ECA (d = 1.19 mm, both P < .001). In contrast, angular length was significantly higher in MRI (d = 26.79°, P < .001). When the values were set in relation to the frequencies of the cochlea, no clinically relevant differences were estimated (58 Hz at 28-mm CDL). CONCLUSION: In the presented study, CDL was investigated in CT and MRI by using different approaches. Since no clinically relevant differences were found, diagnostics with radiation may be omitted prior to cochlear implantation; thus, a concept of radiation-free cochlear implantation could be established.

6.
Otol Neurotol ; 42(3): e294-e303, 2021 03 01.
Article En | MEDLINE | ID: mdl-33555750

HYPOTHESIS: Flat-panel volume computed tomography (fpVCT) and secondary reconstruction allow for more accurate measurements of two-turn length (2TL), cochlear duct length (CDL), and angular length (AL). BACKGROUND: Cochlear geometry is a controversially debated topic. In the meantime, there are many different studies partly reporting highly divergent values. Our aim is to discuss the differences and to propose a radiological possibility to improve cochlear measurements using 3D-curved multiplanar reconstruction and fpVCT. METHODS: Performing different image modalities and settings, we tried to find a clinically usable option that allows for a high degree of accuracy. Therefore, we tested them against reference values of high-definition micro-computed tomography. RESULTS: Comparison of 99 µm slice thickness secondary reconstruction of fpVCT and reference showed no significant differences for 2TL and CDL (p ≥ 0.05). Accordingly, ICC (intraclass correlation) values were excellent (ICC ≥ 0.75; lower limit of confidence interval [CI] ≥ 0.75; Cronbach's alpha [α] ≥ 0.9). Evaluating AL, there was a significant difference (difference: -17.27°; p = 0.002). The lower limit of the CI of the ICC was unacceptable (ICC = 0.944; lower limit of CI = 0.248; α = 0.990). Regarding the Bland-Altman plots, there were no clinically unacceptable errors, but a systematic underestimation of AL. CONCLUSION: Secondary reconstruction is a suitable tool for producing reliable data that allow the accurate measurement of 2TL and CDL. The option of generating these reconstructions from raw data limits the need for higher radiation doses. Nevertheless, there is an underestimation of AL using secondary reconstructions.


Cochlea , Cochlear Duct , Cochlea/diagnostic imaging , Cone-Beam Computed Tomography , Humans , X-Ray Microtomography
...