Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
1.
Craniomaxillofac Trauma Reconstr ; 11(2): 118-123, 2018 Jun.
Article En | MEDLINE | ID: mdl-29892326

The aim of this prospective study was to appraise the role of embrasure wiring in the treatment of mandibular fractures over the arch bar as adjunctive techniques of maxillomandibular fixation (MMF). This study was conducted on 40 patients who were surgically treated for mandibular fractures with accessory use of MMF (embrasure: group A vs. arch bars: group B). All patients were evaluated for demographic data, etiology, and location of fracture. Characteristically, the complications, including wire injury, infection, and malocclusion, were recorded. The data were analyzed using Student's t -test and chi-square test as appropriate. Statistical significance was set at p < 0.05). In this study, data from 40 patients were included. In group A (embrasure wiring), time required for placement of MMF was significantly less than (7.85 ± 0.81 minutes) that in group B, and also there was less incidence of wire prick to the operator in group A than in group B ( p < 0.05). However, in terms of wire prick and malocclusion, no statistically significant difference was noted in groups A and B ( p > 0.05). Patient treated with embrasure wiring intermaxillary fixation had better outcomes especially in terms of time of placement and less incidence of wire prick injury when compared with arch bar.

2.
Craniomaxillofac Trauma Reconstr ; 10(3): 188-196, 2017 Sep.
Article En | MEDLINE | ID: mdl-28751942

The aim of this simple nonrandomized and observational study was to evaluate the efficacy of single three-dimensional (3D) plate for the treatment of mandibular angle fractures without maxillomandibular fixation. A total of 30 patients with noncomminuted fractures of mandibular angle requiring open reduction and internal fixation were included in the study. All the patients were treated by open reduction and internal fixation using single 3D titanium locking miniplate placed with the help of transbuccal trocar or Synthes 90-degree hand piece and screw driver. 3D locking titanium miniplates used in our study was four-holed, box-shaped plate, and screws with 2 mm diameter and 8 mm length. The following clinical parameters were assessed for each patient at each follow-up visit: pain (visual analog scale: 0-5), swelling (visual analog scale: 0-5), mouth opening, infection, paresthesia, hardware failure (plate fracture), occlusal discrepancies, and mobility between fracture fragments. A significant decrease in pain level was seen during the follow-up visits. No statistically significant changes were seen in swelling, but mouth opening increased in the subsequent visits. Also better results were seen in terms of fracture stability and occlusion in the postoperative period. Two cases of infection and two cases of hardware failure were noted in sixth postoperative week. 3D plating system is an easy to use alternative to conventional miniplates to treat mandibular angle fractures that uses lesser foreign material, thus reducing the operative time and overall cost of the treatment. Better fracture stability and occlusion was also achieved using the 3D plating system.

3.
J Maxillofac Oral Surg ; 14(4): 972-8, 2015 Dec.
Article En | MEDLINE | ID: mdl-26604472

AIMS AND OBJECTIVES: To compare and evaluate the variation in recorded bite forces in patients with mandibular fractures undergoing open reduction and rigid internal fixation using standard 2.0 versus 2.0 mm locking miniplates. MATERIALS AND METHODS: A prospective randomized study was conducted for the treatment of mandibular fractures. Twenty adult patients with 31 mandibular fractures requiring an open reduction and internal fixation were included in the study. The sample was divided into two groups depending upon whether the patients received 2.0 mm non-locking (standard) or 2.0 mm locking miniplates for rigid fixation respectively. Bite force was evaluated at 1st, 3rd and 6th week after the open reduction and rigid fixation using miniplates. RESULTS: A statistically significant difference was not found in the clinical parameters such as pain, swelling, infection, paresthesia, hardware failure, and mobility between the fracture segments. The results showed that amongst locking vs non-locking miniplates, the former showed a greater bite force enhancement when compared to baseline values(post-trauma).A comparison between 2nd day post-operative vs 6th week post-operative values showed a significant increase in bite force in Group 1 (non-locking) (p < 0.05) whereas the values Were highly significant (p < 0.001) in Group 2 (locking Plate). CONCLUSION: The findings were suggestive that the efficacy of locking miniplates plate in mandibular fracture was superior in terms of bearing the masticatory loads during osteosynthesis of the fracture. However, the clinical results were almost similar to those seen with non-locking miniplate osteosynthesis.

...