Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 20
1.
ChemSusChem ; : e202400440, 2024 May 07.
Article En | MEDLINE | ID: mdl-38713146

The cathodic reduction of pressurized CO2 (PrCO2CR) at suitable cathodes can allow to produce various chemicals, such as formic acid/formate (FA) and carbon monoxide or synthesis gas, with high faradic efficiencies (FEs) and productivities. Here, we have performed the conversion of CO2 in an undivided pressurized electrochemical reactor using silver cathode in order to determine the optimal values of CO2 pressure and current density. It was found that the plot FE vs. pressure resulted in a curve with a maximum. Similarly, an optimal value of current density can be selected for the PrCO2CR. The competition between the production of carbon monoxide and formic acid/formate is strongly affected by both the pressure and the current density. Eventually the effect of pressure and current density on the economic figures of the process was evaluated.

2.
Talanta ; 272: 125772, 2024 May 15.
Article En | MEDLINE | ID: mdl-38367400

Hydrogen peroxide (H2O2) is a biomarker relevant for oxidative stress monitoring. Most chronic airway diseases are characterized by increased oxidative stress. To date, the main methods for the detection of this analyte are expensive and time-consuming laboratory techniques such as fluorometric and colorimetric assays. There is a growing interest in the development of electrochemical sensors for H2O2 detection due to their low cost, ease of use, sensitivity and rapid response. In this work, an electrochemical sensor based on gold nanowire arrays has been developed. Thanks to the catalytic activity of gold against hydrogen peroxide reduction and the high surface area of nanowires, this sensor allows the quantification of this analyte in a fast, efficient and selective way. The sensor was obtained by template electrodeposition and consists of gold nanowires about 5 µm high and with an average diameter of about 200 nm. The high active surface area of this electrode, about 7 times larger than a planar gold electrode, ensured a high sensitivity of the sensor (0.98 µA µM-1cm-2). The sensor allows the quantification of hydrogen peroxide in the range from 10 µM to 10 mM with a limit of detection of 3.2 µM. The sensor has excellent properties in terms of reproducibility, repeatability and selectivity. The sensor was validated by quantifying the hydrogen peroxide released by human airways A549 cells exposed or not to the pro-oxidant compound rotenone. The obtained results were validated by comparing them with those obtained by flow cytometry after staining the cells with the fluorescent superoxide-sensitive Mitosox Red probe giving a very good concordance.


Hydrogen Peroxide , Nanowires , Humans , Hydrogen Peroxide/chemistry , Nanowires/chemistry , Gold/chemistry , Reproducibility of Results , Electrochemical Techniques/methods , Epithelial Cells , Electrodes
3.
Int J Mol Sci ; 24(22)2023 Nov 08.
Article En | MEDLINE | ID: mdl-38003276

Lung cancer frequently affects patients with Chronic Obstructive Pulmonary Disease (COPD). Cigarette smoke (CS) fosters cancer progression by increasing oxidative stress and by modulating epithelial-mesenchymal transition (EMT) processes in cancer cells. Formoterol (FO), a long-acting ß2-agonist widely used for the treatment of COPD, exerts antioxidant activities. This study explored in a lung adenocarcinoma cell line (A549) whether FO counteracted the effects of cigarette smoke extract (CSE) relative to oxidative stress, inflammation, EMT processes, and cell migration and proliferation. A549 was stimulated with CSE and FO, ROS were evaluated by flow-cytometry and by nanostructured electrochemical sensor, EMT markers were evaluated by flow-cytometry and Real-Time PCR, IL-8 was evaluated by ELISA, cell migration was assessed by scratch and phalloidin test, and cell proliferation was assessed by clonogenic assay. CSE significantly increased the production of ROS, IL-8 release, cell migration and proliferation, and SNAIL1 expression but significantly decreased E-cadherin expression. FO reverted all these phenomena in CSE-stimulated A549 cells. The present study provides intriguing evidence that FO may exert anti-cancer effects by reverting oxidative stress, inflammation, and EMT markers induced by CS. These findings must be validated in future clinical studies to support FO as a valuable add-on treatment for lung cancer management.


Adenocarcinoma of Lung , Cigarette Smoking , Lung Neoplasms , Pulmonary Disease, Chronic Obstructive , Humans , Epithelial-Mesenchymal Transition , Reactive Oxygen Species/metabolism , Formoterol Fumarate/metabolism , Formoterol Fumarate/pharmacology , Interleukin-8/metabolism , Pulmonary Disease, Chronic Obstructive/metabolism , Adenocarcinoma of Lung/pathology , Nicotiana/metabolism , Lung Neoplasms/metabolism , Epithelial Cells/metabolism , Oxidative Stress , Inflammation/metabolism
4.
Materials (Basel) ; 16(2)2023 Jan 04.
Article En | MEDLINE | ID: mdl-36676217

To realize the benefits of a hydrogen economy, hydrogen must be produced cleanly, efficiently and affordably from renewable resources and, preferentially, close to the end-users. The goal is a sustainable cycle of hydrogen production and use: in the first stage of the cycle, hydrogen is produced from renewable resources and then used to feed a fuel cell. This cycle produces no pollution and no greenhouse gases. In this context, the development of electrolyzers producing high-purity hydrogen with a high efficiency and low cost is of great importance. Electrode materials play a fundamental role in influencing electrolyzer performances; consequently, in recent years considerable efforts have been made to obtain highly efficient and inexpensive catalyst materials. To reach both goals, we have developed electrodes based on Pd-Co alloys to be potentially used in the PEMEL electrolyzer. In fact, the Pd-Co alloy is a valid alternative to Pt for hydrogen evolution. The alloys were electrodeposited using two different types of support: carbon paper, to fabricate a porous structure, and anodic alumina membrane, to obtain regular arrays of nanowires. The goal was to obtain electrodes with very large active surface areas and a small amount of material. The research demonstrates that the electrochemical method is an ideal technique to obtain materials with good performances for the hydrogen evolution reaction. The Pd-Co alloy composition can be controlled by adjusting electrodeposition parameters (bath composition, current density and deposition time). The main results concerning the fabrication process and the characterization are presented and the performance in acid conditions is discussed.

5.
Polymers (Basel) ; 14(23)2022 Nov 24.
Article En | MEDLINE | ID: mdl-36501503

Calcium phosphate/chitosan/collagen composite coating on AISI 304 stainless steel was investigated. Coatings were realized by galvanic coupling that occurs without an external power supply because it begins with the coupling between two metals with different standard electrochemical potentials. The process consists of the co-deposition of the three components with the calcium phosphate crystals incorporated into the polymeric composite of chitosan and collagen. Physical-chemical characterizations of the samples were executed to evaluate morphology and chemical composition. Morphological analyses have shown that the surface of the stainless steel is covered by the deposit, which has a very rough surface. XRD, Raman, and FTIR characterizations highlighted the presence of both calcium phosphate compounds and polymers. The coatings undergo a profound variation after aging in simulated body fluid, both in terms of composition and structure. The tests, carried out in simulated body fluid to scrutinize the corrosion resistance, have shown the protective behavior of the coating. In particular, the corrosion potential moved toward higher values with respect to uncoated steel, while the corrosion current density decreased. This good behavior was further confirmed by the very low quantification of the metal ions (practically absent) released in simulated body fluid during aging. Cytotoxicity tests using a pre-osteoblasts MC3T3-E1 cell line were also performed that attest the biocompatibility of the coating.

6.
Sensors (Basel) ; 22(21)2022 Oct 27.
Article En | MEDLINE | ID: mdl-36365929

Wearable sensors for sweat biomarkers can provide facile analyte capability and monitoring for several diseases. In this work, a green wearable sensor for sweat absorption and chloride sensing is presented. In order to produce a sustainable device, polylactic acid (PLA) was used for both the substrate and the sweat absorption pad fabrication. The sensor material for chloride detection consisted of silver-based reference, working, and counter electrodes obtained from upcycled compact discs. The PLA substrates were prepared by thermal bonding of PLA sheets obtained via a flat die extruder, prototyped in single functional layers via CO2 laser cutting, and bonded via hot-press. The effect of cold plasma treatment on the transparency and bonding strength of PLA sheets was investigated. The PLA membrane, to act as a sweat absorption pad, was directly deposited onto the membrane holder layer by means of an electrolyte-assisted electrospinning technique. The membrane adhesion capacity was investigated by indentation tests in both dry and wet modes. The integrated device made of PLA and silver-based electrodes was used to quantify chloride ions. The calibration tests revealed that the proposed sensor platform could quantify chloride ions in a sensitive and reproducible way. The chloride ions were also quantified in a real sweat sample collected from a healthy volunteer. Therefore, we demonstrated the feasibility of a green and integrated sweat sensor that can be applied directly on human skin to quantify chloride ions.


Biosensing Techniques , Wearable Electronic Devices , Humans , Sweat , Chlorides , Silver , Polyesters , Biosensing Techniques/methods , Electrochemical Techniques/methods
7.
Micromachines (Basel) ; 13(10)2022 Oct 18.
Article En | MEDLINE | ID: mdl-36296115

Quantification of oxidative stress is a challenging task that can help in monitoring chronic inflammatory respiratory airway diseases. Different studies can be found in the literature regarding the development of electrochemical sensors for H2O2 in cell culture medium to quantify oxidative stress. However, there are very limited data regarding the impact of the cell culture medium on the electrochemical quantification of H2O2. In this work, we studied the effect of different media (RPMI, MEM, DMEM, Ham's F12 and BEGM/DMEM) on the electrochemical quantification of H2O2. The used electrode is based on reduced graphene oxide (rGO) and gold nanoparticles (AuNPs) and was obtained by co-electrodeposition. To reduce the electrode fouling by the medium, the effect of dilution was investigated using diluted (50% v/v in PBS) and undiluted media. With the same aim, two electrochemical techniques were employed, chronoamperometry (CH) and linear scan voltammetry (LSV). The influence of different interfering species and the effect of the operating temperature of 37 °C were also studied in order to simulate the operation of the sensor in the culture plate. The LSV technique made the sensor adaptable to undiluted media because the test time is short, compared with the CH technique, reducing the electrode fouling. The long-term stability of the sensors was also evaluated by testing different storage conditions. By storing the electrode at 4 °C, the sensor performance was not reduced for up to 21 days. The sensors were validated measuring H2O2 released by two different human bronchial epithelial cell lines (A549, 16HBE) and human primary bronchial epithelial cells (PBEC) grown in RPMI, MEM and BEGM/DMEM media. To confirm the results obtained with the sensor, the release of reactive oxygen species was also evaluated with a standard flow cytometry technique. The results obtained with the two techniques were very similar. Thus, the LSV technique permits using the proposed sensor for an effective oxidative stress quantification in different culture media and without dilution.

8.
Polymers (Basel) ; 14(12)2022 Jun 19.
Article En | MEDLINE | ID: mdl-35746069

Hybrid porous scaffolds composed of both natural and synthetic biopolymers have demonstrated significant improvements in the tissue engineering field. This study investigates for the first time the fabrication route and characterization of poly-L-lactic acid scaffolds blended with polyhydroxyalkanoate up to 30 wt%. The hybrid scaffolds were prepared by a thermally induced phase separation method starting from ternary solutions. The microstructure of the hybrid porous structures was analyzed by scanning electron microscopy and related to the blend composition. The porosity and the wettability of the scaffolds were evaluated through gravimetric and water contact angle measurements, respectively. The scaffolds were also characterized in terms of the surface chemical properties via Fourier transform infrared spectroscopy in attenuated total reflectance. The mechanical properties were analyzed through tensile tests, while the crystallinity of the PLLA/PHA scaffolds was investigated by differential scanning calorimetry and X-ray diffraction.

9.
Int J Mol Sci ; 23(3)2022 Feb 04.
Article En | MEDLINE | ID: mdl-35163691

Exposure of the airways epithelium to environmental insults, including cigarette smoke, results in increased oxidative stress due to unbalance between oxidants and antioxidants in favor of oxidants. Oxidative stress is a feature of inflammation and promotes the progression of chronic lung diseases, including Chronic Obstructive Pulmonary Disease (COPD). Increased oxidative stress leads to exhaustion of antioxidant defenses, alterations in autophagy/mitophagy and cell survival regulatory mechanisms, thus promoting cell senescence. All these events are amplified by the increase of inflammation driven by oxidative stress. Several models of bronchial epithelial cells are used to study the molecular mechanisms and the cellular functions altered by cigarette smoke extract (CSE) exposure, and to test the efficacy of molecules with antioxidant properties. This review offers a comprehensive synthesis of human in-vitro and ex-vivo studies published from 2011 to 2021 describing the molecular and cellular mechanisms evoked by CSE exposure in bronchial epithelial cells, the most used experimental models and the mechanisms of action of cellular antioxidants systems as well as natural and synthetic antioxidant compounds.


Cigarette Smoking/adverse effects , Epithelial Cells/drug effects , Oxidative Stress , Animals , Bronchi/drug effects , Bronchi/metabolism , Bronchi/physiopathology , Epithelial Cells/metabolism , Epithelial Cells/physiology , Humans , Inflammation
10.
Materials (Basel) ; 15(3)2022 Jan 18.
Article En | MEDLINE | ID: mdl-35160668

Immunoglobulin G (IgG), a type of antibody, represents approximately 75% of serum antibodies in humans, and is the most common type of antibody found in blood circulation. Consequently, the development of simple, fast and reliable systems for IgG detection, which can be achieved using electrochemical sandwich-type immunosensors, is of considerable interest. In this study we have developed an immunosensor for human (H)-IgG using an inexpensive and very simple fabrication method based on ZnO nanorods (NRs) obtained through the electrodeposition of ZnO. The ZnO NRs were treated by electrodepositing a layer of reduced graphene oxide (rGO) to ensure an easy immobilization of the antibodies. On Indium Tin Oxide supported on Polyethylene Terephthalate/ZnO NRs/rGO substrate, the sandwich configuration of the immunosensor was built through different incubation steps, which were all optimized. The immunosensor is electrochemically active thanks to the presence of gold nanoparticles tagging the secondary antibody. The immunosensor was used to measure the current density of the hydrogen development reaction which is indirectly linked to the concentration of H-IgG. In this way the calibration curve was constructed obtaining a logarithmic linear range of 10-1000 ng/mL with a detection limit of few ng/mL and good sensitivity.

11.
Anal Chim Acta ; 1190: 339215, 2022 Jan 15.
Article En | MEDLINE | ID: mdl-34857136

In this work electrochemical sensors fabricated from compact disc material (waste or new) are used to quantify chloride ions in different types of samples. All three electrodes, working, counter, and pseudo-reference electrodes, were fabricated from the compact disc and directly used. Different parameters were studied in order to demonstrate the possibility of using this waste material for efficient and low-cost electrochemical sensors. Chloride sensing performance was evaluated using linear scan voltammetry as the detection technique. A sensitivity of 0.174 mA mM-1 cm-2 with a limit of detection of 20 µM and excellent selectivity against many interferents was observed. Selectivity and reproducibility tests were also carried out, showing excellent results. Sensors were also validated with real samples (drinking and sea water, milk, sweat and physiological solutions) with results comparable to conventional techniques. Our results show the applicability and suitability of these low-cost sensors, for detection of those analytes for which, silver, has high sensitivity and selectivity.


Chlorides , Electrochemical Techniques , Compact Disks , Electrodes , Reproducibility of Results
12.
Anal Chim Acta ; 1187: 339124, 2021 Dec 01.
Article En | MEDLINE | ID: mdl-34753568

Dopamine is an important neurotransmitter involved in many human biological processes as well as in different neurodegenerative diseases. Monitoring the concentration of dopamine in biological fluids, i.e., blood and urine is an effective way of accelerating the early diagnosis of these types of diseases. Electrochemical sensors are an ideal choice for real-time screening of dopamine as they can achieve fast, portable inexpensive and accurate measurements. In this work, we present electrochemical dopamine sensors based on reduced graphene oxide coupled with Au or Pt nanoparticles. Sensors were developed by co-electrodeposition onto a flexible substrate, and a systematic investigation concerning the electrodeposition parameters (concentration of precursors, deposition time and potential) was carried out to maximize the sensitivity of the dopamine detection. Square wave voltammetry was used as an electrochemical technique that ensured a high sensitive detection in the nM range. The sensors were challenged against synthetic urine in order to simulate a real sample detection scenario where dopamine concentrations are usually lower than 600 nM. Our sensors show a negligible interference from uric and ascorbic acids which did not affect sensor performance. A wide linear range (0.1-20 µm for gold nanoparticles, 0.1-10 µm for platinum nanoparticles) with high sensitivity (6.02 and 7.19 µA µM-1 cm-2 for gold and platinum, respectively) and a low limit of detection (75 and 62 nM for Au and Pt, respectively) were achieved. Real urine samples were also assayed, where the concentrations of dopamine detected aligned very closely to measurements undertaken using conventional laboratory techniques. Sensor fabrication employed a cost-effective production process with the possibility of also being integrated into flexible substrates, thus allowing for the possible development of wearable sensing devices.


Graphite , Metal Nanoparticles , Ascorbic Acid , Dopamine , Electrochemical Techniques , Electrodes , Gold , Humans , Platinum , Uric Acid
13.
Materials (Basel) ; 14(11)2021 May 24.
Article En | MEDLINE | ID: mdl-34073770

The paper reports some preliminary results concerning the manufacturing process of CuZnSnSe (CZTSe) and CuInGaSe (CIGS) nanowire arrays obtained by one-step electrodeposition for p-n junction fabrication. CZTSe nanowires were obtained through electrodeposition in a polycarbonate membrane by applying a rectangular pulsed current, while their morphology was optimized by appropriately setting the potential and the electrolyte composition. The electrochemical parameters, including pH and composition of the solution, were optimized to obtain a mechanically stable array of nanowires. The samples were characterized by scanning electron microscopy, Raman spectroscopy, and energy-dispersion spectroscopy. The nanostructures obtained showed a cylindrical shape with an average diameter of about 230 nm and a length of about 3 µm, and were interconnected due to the morphology of the polycarbonate membrane. To create the p-n junctions, first a thin film of CZTSe was electrodeposited to avoid direct contact between the ZnS and Mo. Subsequently, an annealing process was carried out at 500 °C in a S atmosphere for 40 min. The ZnS was obtained by chemical bath deposition at 95 °C for 90 min. Finally, to complete the cell, ZnO and ZnO:Al layers were deposited by magnetron-sputtering.

14.
J Nanosci Nanotechnol ; 20(2): 999-1007, 2020 Feb 01.
Article En | MEDLINE | ID: mdl-31383097

In this work, a systematic investigation of the different parameters that control the electrodeposition processes was carried out at the aim to synthetizing AgGaSe2 nanostructures. We found that pH is a key parameter to control both the morphology and composition of the nanostructures. Low pH favours mainly the formation of Ag2Se nanotubes with a scarce mechanical stability, while multi-phase nanowires well anchored to the substrate were obtained at higher pH. We also found that it was necessary to increase dramatically the concentration of the gallium precursor into the deposition bath in order to obtain AgGaSe2 owing to lower redox potential of the Ga3+/Ga couple than Ag2+/Ag and Se4+/Se. Besides, the addition of specific complexing agents to deposition bath was necessary to better control the composition of the nanostructures. By increasing gallium precursor concentration and adding complexing agents, it was possible to obtain for the first time nanostructures of amorphous AgGaSe2 with different amount of Ga via one-step electrodeposition.

15.
J Nanosci Nanotechnol ; 19(11): 7398-7403, 2019 Nov 01.
Article En | MEDLINE | ID: mdl-31039903

Currently, lead acid battery is extensively investigated owing to its prevalent use as a startinglighting and ignition device. An essential role for electrochemical reactions is played by the surface area available for conversion reactions and a possible approach is the use of nanostructured electrodes. In this work, lead dioxide nanostructured electrodes were tested in order to investigate the dependence of the charge and discharge behaviour on some parameters such as electrolyte concentration, and a new type of thin separator. In this last case, it is possible to reduce the size of the cell by using a very thin separator comparable to the nanostructured electrode thickness. Besides, a low concentration of electrolyte was also tested for studying its influence on the performance of a nanostructured electrode. Lead dioxide electrodes were cycled at 1C-rate and discharged to a cutoff voltage of 1.2 V up to 90% of the gravimetric capacity. Electrodes were assembled in a zero gap configuration using a commercial negative plate as counter-electrode with a large excess of active mass in comparison to the nanostructured one. Tests were conducted in very stressful conditions, in order to compare the behaviour of this new type of battery with that of the commercial one.

16.
J Nanosci Nanotechnol ; 19(8): 4677-4685, 2019 08 01.
Article En | MEDLINE | ID: mdl-30913768

In this paper, we report a detailed study on the synthesis of composite nanowires of Pb-PbOHCl via galvanic deposition into the pores of a membrane acting as a template. PbOHCl deposition quantitatively occurs as the solution pH exceeds the value of about 4.12. Simultaneously, owing to the galvanic coupling, electro-deposition of lead occurs, so composite nanowires were formed. The role of different parameters controlling the kinetic evolution of the process, such as oxygen bubbling, solution pH, surface area and type of sacrificial anode were investigated one at a time. The results suggest that every modification accelerating the alkalization of the solution inside the template pores favors growth of composite nanowires richer in PbOHCl. Alumina and polycarbonate membranes were investigated as template, and the best results were obtained for polycarbonate membrane, which can be easily removed by dissolution in CHCl3 avoiding the collapse and successive loss of the nanowires.

17.
J Nanosci Nanotechnol ; 19(6): 3459-3470, 2019 06 01.
Article En | MEDLINE | ID: mdl-30744773

In this work, we present some results concerning the electrochemical behavior of nanostructured-based electrochemical sensors. In particular, the attention has been focused on Pd and Cu nanowires for detection of hydrogen peroxide and NiO thin film or Ni@NiO core-shell nanowires for detection of mercury ions. Ordered array of Pd and Cu nanowires was obtained through displacement deposition reaction in a commercial polycarbonate membrane acting as a template. The method leads to stable nanostructured electrodes of Pd and Cu with high surface area. For the detection of mercury ions, we have fabricated a Ni/NiO electrochemical sensor, obtained by mild thermal oxidation of Ni-foil. Some results on Ni@NiO core-shell nanowires were also reported. The effect of oxidation time and temperature was studied in order to compare performances of the Ni@NiO nanowire array with those of NiO thin film. All samples were characterized by XRD, SEM and EDS analysis. Electrochemical tests have been conducted in order to characterize specific electrode performance such as sensibility, selectivity, and accuracy. Highly satisfying results have been obtained.

18.
ACS Biomater Sci Eng ; 5(4): 1715-1724, 2019 Apr 08.
Article En | MEDLINE | ID: mdl-33405548

A galvanic method to deposit chitosan coatings on stainless steel substrate is reported. Deposition of suitable coatings is desired to improve biocompatibility and corrosion resistance of metallic medical devices to be implanted in human body. In the present work, a thin hydrogel layer of chitosan was deposited on 304SS by a galvanic displacement reaction, which is advantageous first as it does not require external power supply. 304SS was immersed into an aqueous solution of chitosan/lactic acid and electrochemically coupled with magnesium acting as a sacrificial anode. SEM images showed the formation of a uniform layer of chitosan with a thickness controlled by deposition time. Corrosion tests in simulating body fluid showed that chitosan coatings shift the corrosion potential of 304 substrates toward nobler values. Finally, the cytotoxicity of the coating was investigated through cell viability assays with osteoblastic cell MC3T3-E1. The results revealed highly satisfying biocompatibility of the coating.

19.
Nat Prod Commun ; 11(6): 849-52, 2016 Jun.
Article En | MEDLINE | ID: mdl-27534133

Plants yields are influenced by agronomic techniques. Plant density is a complex issue and extremely important when maximizing both crop quality, and biomass and essential oil yields. Plants belonging to the Origanum vulgare subspecies hirtum (Link) Ietswaart were grown adopting four types of plant density and were characterized in biometric and chemical terms. The samples were analyzed using the ANOVA (Principal Component Analysis) statistical method regarding biometric aspects, EO yield and peltate hair density. Essential oil (EO) was extracted by hydrodistillation and analyzed using GC-FID and GC-MS. GC-FID and GC-MS analysis led to the identification of 45 compounds from the EO. Plant density affected production both in terms of biomass and EO. However, it was not found to have affected peltate glandular trichome density or EO quality.


Oils, Volatile/chemistry , Origanum/growth & development , Trichomes/growth & development , Gas Chromatography-Mass Spectrometry , Origanum/chemistry , Origanum/ultrastructure , Quality Control , Trichomes/chemistry , Trichomes/ultrastructure
20.
Mater Sci Eng C Mater Biol Appl ; 64: 93-101, 2016 Jul 01.
Article En | MEDLINE | ID: mdl-27127032

In this work, brushite and brushite/hydroxyapatite (BS, CaHPO4·H2O; HA, Ca10(PO4)6(OH)2) coatings were deposited on 316L stainless steel (316LSS) from a solution containing Ca(NO3)2·4H2O and NH4H2PO4 by a displacement reaction based on a galvanic contact, where zinc acts as sacrificial anode. Driving force for the cementation reaction arises from the difference in the electrochemical standard potentials of two different metallic materials (316LSS and Zn) immersed in an electrolyte, so forming a galvanic contact leading to the deposition of BS/HA on nobler metal. We found that temperature and deposition time affect coating features (morphology, structure, and composition). Deposits were characterized by means of several techniques. The morphology was investigated by scanning electron microscopy, the elemental composition was obtained by X-ray energy dispersive spectroscopy, whilst the structure was identified by Raman spectroscopy and X-ray diffraction. BS was deposited at all investigated temperatures covering the 316LSS surface. At low and moderate temperature, BS coatings were compact, uniform and with good crystalline degree. On BS layers, HA crystals were obtained at 50°C for all deposition times, while at 25°C, its presence was revealed only after long deposition time. Electrochemical studies show remarkable improvement in corrosion resistance.


Calcium Phosphates/chemistry , Durapatite/chemistry , Electrochemical Techniques , Stainless Steel/chemistry
...