Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39032079

RESUMEN

PURPOSE: To histometrically compare the osseointegration and crestal bone healing of a novel tapered, self-cutting tissue-level test implant with a standard tissue-level control implant in a submerged healing regimen. MATERIALS AND METHODS: In a mandibular minipig model, implants were inserted and evaluated histometrically after a healing period of 3, 6, and 12 weeks. The primary outcome was the evaluation of bone-to-implant contact (BIC) and secondary outcomes were primary stability as per insertion torque and first BIC (fBIC). Outcomes for the test and control implants were compared using Wilcoxon signed-rank tests and mixed linear regression models. RESULTS: Insertion torque values were significantly higher for the test (50.0 ± 26.4 Ncm) compared to the control implants (35.2 ± 19.7 Ncm, p = .0071). BIC values of test implants were non-inferior to those of control implants over the investigated study period. After 12 weeks, the corresponding values measured were 81.62 ± 11.12% and 90.41 ± 4.81% (p = .1763) for test and control implants, respectively. Similarly, no statistical difference was found for fBIC values, except for the 12 weeks outcome that showed statistically lower values for the test (-675.58 ± 590.88 µm) compared to control implants (-182.75 ± 197.40 µm, p = .0068). CONCLUSIONS: Novel self-cutting tissue-level implants demonstrated noninferior osseointegration and crestal bone height maintenance to the tissue-level implants. Histometric outcomes between both implants demonstrated test implants were statistically noninferior to control implants, despite substantial differences in the bone engagement mechanism and resulting differences in insertion torque and qualitative bone healing patterns.

2.
J Periodontal Res ; 2024 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-38764144

RESUMEN

AIMS: To histologically compare osseointegration and crestal bone healing between newly introduced tapered, self-cutting bone-level test implants and tapered bone-level control implants in sites with fully healed sites. METHODS: Sixty-six implants (33 test, 33 control) were placed 1 mm subcrestally in a minipig model and underwent qualitative histologic and quantitative histometric analyses after 3, 6 and 12 weeks of submerged healing. The primary and secondary outcomes were the bone-to-implant contact (BIC) and first bone-to-implant contact (fBIC). Outcomes between the test and control implants were statistically compared. RESULTS: The BIC values of the test implants were comparable and non-inferior over the time points studied, except for the 12 weeks time point which showed statistically significantly higher BIC values of the test (88.07 ± 5.35%) compared to the control implants (80.88 ± 7.51%) (p = .010). Similarly comparable and non-inferior were the fBIC values, except for the 6-week outcome, which showed statistically higher values for the test (-546.5 ± 450.80 µm) compared to the control implants (-75.7 ± 100.59 µm). fBIC results for the test implants were qualitatively more stable and consistent between test time points. CONCLUSION: Novel self-cutting bone-level test implants demonstrated superior osseointegration and similar bone levels compared to conventional bone-level implants after a healing period of 12 weeks in healed ridges.

3.
Clin Oral Investig ; 28(3): 190, 2024 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-38430333

RESUMEN

OBJECTIVES: An adjunct in non-surgical periodontal therapy might be sodium hypochlorite (NaOCl)-based agents. The purpose of the present in vitro study was to get deeper knowledge on the influence of different parameters as time after mixing, pH, and chemical composition of an amino acid 0.475% NaOCl (AA-NaOCl) gel consisting of two components on its anti-biofilm activity. MATERIALS AND METHODS: Six-species biofilms were cultured for 5 days, before AA-NaOCl gel was applied. In the different series, the influence of the time after mixing of the two components before application, of the concentration of NaOCl in the gel mixture, of the pH of the gel mixture, and of an exchange of the amino acid component by hyaluronic acid (HA), was analyzed. RESULTS: Mixing time point experiments showed that the AA-NaOCl gel is capable of statistically significantly reducing colony-forming unit (cfu) counts up to 30 min after mixing, but only up to 20 min after mixing the reduction was more than 2 log10 cfu. The pH experiments indicate that a reduced pH results in a reduced activity of the NaOCl formulation. NaOCl concentrations in the formulation in the range from 0.475 to 0.2% provide adequate activity on biofilms. A HA/NaOCl gel was equally active against the biofilm as the AA-NaOCl gel. CONCLUSION: Mixing of the components should be made in a timeframe of 20 min before applications. An optimization of the composition of the NaOCl formulation might be possible and should be a topic in further in vitro studies. CLINICAL RELEVANCE: The AA-NaOCl gel formulation can be mixed up to 20 min before application. Further, the study indicates that the composition of the NaOCl gel formulation can be optimized.


Asunto(s)
Enfermedades Periodontales , Hipoclorito de Sodio , Humanos , Hipoclorito de Sodio/farmacología , Hipoclorito de Sodio/química , Enterococcus faecalis , Enfermedades Periodontales/tratamiento farmacológico , Bacterias , Aminoácidos/farmacología
4.
BMC Oral Health ; 22(1): 189, 2022 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-35590298

RESUMEN

BACKGROUND: Evidence on the effect of magnification devices on procedure quality in restorative dentistry is scant. This study therefore aimed to assess, under simulated clinical conditions, if magnification loupes affect the quality of preparations carried out by undergraduate dental students. METHODS: 59 undergraduate dental students underwent two visual acuity tests, based on which they were divided into a "low visual acuity group" (visus < 1) and a "good visual acuity group" (visus ≥ 1). In a randomized crossover experiment, participants performed a two-dimensional S and a three-dimensional O figure preparation with a dental handpiece on standardized acrylic blocs designed for preclinical restorative training. Each participant carried out the preparation tasks twice, once with magnification loupes (2.5×) and once without. Two blinded investigators independently evaluated parameters of preparation precision. Data were analyzed using Spearman rank correlation coefficients, intra-class correlation coefficients, and Wilcoxon rank-sum tests (α = 0.05). RESULTS: Participants from the "low visual acuity group" did not show a statistically significant improvement in accuracy when they used magnification loupes for the S figure preparation (p ≥ 0.0625). Participants from the "high visual acuity group" obtained a higher level of accuracy (p ≤ 0.0012) when they used magnification loupes for the S figure preparation. The use of magnification loupes had no statistically significant effect on the accuracy parameters of the O figure cavity preparations (p ≥ 0.1865). Participants with high visual acuity achieved only a marginally better accuracy than participants with a visus < 1. CONCLUSIONS: This study suggests that loupes with 2.5× magnification increase the accuracy of two-dimensional preparations while they have no significant effect, favorable or otherwise, on the accuracy of complex, three-dimensional cavity preparations of untrained dental students.


Asunto(s)
Lentes , Estudios Cruzados , Preparación de la Cavidad Dental , Odontología , Humanos , Estudiantes de Odontología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA