Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Radiat Prot Dosimetry ; 200(6): 564-571, 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38453140

RESUMEN

The International Atomic Energy Agency, as part of the new regional project (RAF/9/059), recommend the establishment of diagnostic reference levels (DRLs) in Africa. In response to this recommendation, this project was designed to establish and utilise national DRLs of routine computed tomography (CT) examinations. These were done by estimating CT dose index and dose length product (DLP) from a minimum of 20 patient dose report of the most frequently used procedures using 75th percentile distribution of the median values. In all, 22 centres that formed 54% of all CT equipment in the country took part in this study. Additionally, a total of 2156 adult patients dose report were randomly selected, with a percentage distribution of 60, 12, 21 and 7% for head, chest, abdomen-pelvis and lumber spine, respectively. The established DRL for volume CT dose index were 60.0, 15.7, 20.5 and 23.8 mGy for head, chest, abdomen-pelvis and lumber spine, respectively. While the established DRL for DLP were 962.9, 1102.8, 1393.5 and 824.6 mGy-cm for head, chest, abdomen-pelvis, and lumber spine, respectively. These preliminary results were comparable with data from 16 other African countries, European Commission and the International Commission on Radiological Protection. Hence, this study would serve as a baseline for the establishment of a more generalised regional and national adult DRLs for Africa and other developing countries.


Asunto(s)
Dosis de Radiación , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Adulto , Ghana , Niveles de Referencia para Diagnóstico , Masculino , Femenino , Cabeza/diagnóstico por imagen , Persona de Mediana Edad , Valores de Referencia
2.
Radiat Prot Dosimetry ; 198(7): 414-422, 2022 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-35596952

RESUMEN

This preliminary study aims towards the establishment of regional diagnostic reference levels (DRLs) for routine adult computed tomography (CT) examinations. The study was performed on 54 CT facilities from four African countries (Ghana, Kenya, Namibia and Senegal) and the results compared with international DRLs. Data were collected from facilities using a structured questionnaire provided by the International Atomic Energy Agency. Dose descriptors (volume computed tomography dose index [CTDIvol] and dose length product [DLP]) evaluations were performed on CT head and body phantoms for head, chest and abdomen CT examination protocols using standard methods. The estimated dose indices were compared with console-displayed dose values. Experienced radiologists accepted the diagnostic image quality of the images as per departmental imaging requirements. Median CTDIvol and DLP data from each facility were compiled to estimate the typical dose in each country. National DRLs were established based on the 75th percentile of median values, whereas the regional DRLs were based on the median of the national DRLs. Comparison of measured CTDIvol with console values of all facilities in all four countries was within 20% as recommended. The established CTDIvol DRLs for head CT, chest CT and abdomen CT were 60.9 mGy, 15.2 mGy and 15.7 mGy, respectively. Similarly, that of DLP, DRLs were 1259 mGy.cm, 544 mGy.cm and 737 mGy.cm, respectively for head CT, chest CT and abdomen CT. The established DRLs from this study were comparable to DRLs from other countries with some variations. This study would serve as baseline for establishment of a more generalized regional adult CT DRLs for Africa.


Asunto(s)
Niveles de Referencia para Diagnóstico , Tomografía Computarizada por Rayos X , Ghana , Dosis de Radiación , Valores de Referencia , Encuestas y Cuestionarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...