Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 32
1.
J Radiol Prot ; 44(2)2024 May 16.
Article En | MEDLINE | ID: mdl-38530290

The aim of this study is to propose diagnostic reference levels (DRLs) values for mammography in Switzerland. For the data collection, a survey was conducted among a sufficient number of centres, including five University hospitals, several cantonal hospitals, and large private clinics, covering all linguistic regions of Switzerland to be representative of the clinical practice. The data gathered contained the mean glandular dose (MGD), the compressed breast thickness (CBT), the mammography model and the examination parameters for each acquisition. The data collected was sorted into the following categories: 2D or digital breast tomosynthesis (DBT) examination, craniocaudal (CC) or mediolateral oblique (MLO) projection, and eight categories of CBT ranging from 20 mm to 100 mm in 10 mm intervals. A total of 24 762 acquisitions were gathered in 31 centres on 36 mammography units from six manufacturers. The analysis showed that the data reflects the practice in Switzerland. The results revealed that the MGD is larger for DBT than for 2D acquisitions for the same CBT. From 20-30 mm to 90-100 mm of CBT, the 75th percentile of the MGD values obtained increased from 0.81 mGy to 2.55 mGy for 2D CC acquisitions, from 0.83 mGy to 2.96 mGy for 2D MLO acquisitions, from 1.22 mGy to 3.66 mGy for DBT CC acquisitions and from 1.33 mGy to 4.04 mGy for DBT MLO acquisitions. The results of the survey allow us to propose Swiss DRLs for mammography according to the examination type (2D/DBT), projection (CC/MLO) and CBT. The proposed values are very satisfactory in comparison with other studies.


Mammography , Radiation Dosage , Switzerland , Humans , Female , Diagnostic Reference Levels , Breast Neoplasms/diagnostic imaging , Reference Values
2.
Int J Legal Med ; 137(6): 1757-1766, 2023 Nov.
Article En | MEDLINE | ID: mdl-37691040

The AGFAD (Arbeitsgemeinschaft für Forensische Alterdiagnostik, Study Group on Forensic Age Diagnostics) has published several recommendations regarding both technical aspects of computed tomography (CT) of the medial clavicular epiphysis (MCE) and the process of reading and interpreting the CT images for forensic age estimations (FAE). There are, however, no published recommendations regarding CT scan protocols and no dose reference values for CT of the MCE. The objective of this analysis was to assess adherence to AGFAD recommendations among practitioners of FAE and analyse reported dose-relevant CT scan parameters with the objective of helping to establish evidence-based dose reference values for FAE. A systematic literature search was conducted in PubMed and in Google Scholar with specific MeSH terms to identify original research articles on FAE with CT of the MCE from 1997 to 2022. A total of 48 studies were included. Adherence to AGFAD recommendations among practitioners of FAE is high regarding the use of Schmeling main stages (93%), bone window (79%), ≤ 1 mm CT slices (67%), axial/coronal CT images (65%), and Kellinghaus sub-stages (59%). The reporting of CT technique and CT dose-relevant scan parameters is heterogeneous and often incomplete in the current literature. Considering the success achieved by the AGFAD in creating standards of practice of FAE in living subjects, there is potential for the AGFAD to establish standards for radiation protection in FAE as well.

3.
Radiology ; 304(1): 195-204, 2022 07.
Article En | MEDLINE | ID: mdl-35380498

Background Evidence regarding short-term effects of electronic nicotine delivery systems (ENDS) and tobacco smoke on lung ventilation and perfusion is limited. Purpose To examine the immediate effect of ENDS exposure and tobacco smoke on lung ventilation and perfusion by functional MRI and lung function tests. Materials and Methods This prospective observational pilot study was conducted from November 2019 to September 2021 (substudy of randomized controlled trial NCT03589989). Included were 44 healthy adult participants (10 control participants, nine former tobacco smokers, 13 ENDS users, and 12 active tobacco smokers; mean age, 41 years ± 12 [SD]; 28 men) who underwent noncontrast-enhanced matrix pencil MRI and lung function tests before and immediately after the exposure to ENDS products or tobacco smoke. Baseline measurements were acquired after 2 hours of substance abstinence. Postexposure measurements were performed immediately after the exposure. MRI showed semiquantitative measured impairment of lung perfusion (RQ) and fractional ventilation (RFV) impairment as percentages of affected lung volume. Lung clearance index (LCI) was assessed by nitrogen multiple-breath washout to capture ventilation inhomogeneity and spirometry to assess airflow limitation. Absolute differences were calculated with paired Wilcoxon signed-rank test and differences between groups with unpaired Mann-Whitney test. Healthy control participants underwent two consecutive MRI measurements to assess MRI reproducibility. Results MRI was performed and lung function measurement was acquired in tobacco smokers and ENDS users before and after exposure. MRI showed a decrease of perfusion after exposure (RQ, 8.6% [IQR, 7.2%-10.0%] to 9.1% [IQR, 7.8%-10.7%]; P = .03) and no systematic change in RFV (P = .31) among tobacco smokers. Perfusion increased in participants who used ENDS after exposure (RQ, 9.7% [IQR, 7.1%-10.9%] to 9.0% [IQR, 6.9%-10.0%]; P = .01). RFV did not change (P = .38). Only in tobacco smokers was LCI elevated after smoking (P = .02). Spirometry indexes did not change in any participants. Conclusion MRI showed a decrease of lung perfusion after exposure to tobacco smoke and an increase of lung perfusion after use of electronic nicotine delivery systems. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Kligerman in this issue.


Tobacco Smoke Pollution , Vaping , Adult , Humans , Lung/diagnostic imaging , Magnetic Resonance Imaging/methods , Male , Perfusion , Prospective Studies , Reproducibility of Results , Smoking/adverse effects , Vaping/adverse effects
4.
Phys Med ; 94: 102-109, 2022 Feb.
Article En | MEDLINE | ID: mdl-35030383

PURPOSE: Patient shielding during medical X-ray imaging has been increasingly criticized in the last years due to growing evidence that it often provides minimal benefit and may even compromise image quality. In Europe, and as also shown in a short assessment in Switzerland, the use of patient shielding is inhomogeneous. The aim of this study was to systematically review recent literature in order to assess benefits and appraise disadvantages related to the routine use of patient shielding. METHODS: To evaluate benefits and disadvantages related to the application of patient shielding in radiological procedures, a systematic literature review was performed for CT, radiography, mammography and fluoroscopy-guided medical X-ray imaging. In addition, reports from medical physics societies and authorities of different countries were considered in the evaluation. RESULTS: The literature review revealed 479 papers and reports on the topic, from which 87 qualified for closer analysis. The review considered in- and out-of-plane patient shielding as well as shielding for pregnant and pediatric patients. Dose savings and other dose and non-dose related effects of patient shielding were considered in the evaluation. CONCLUSIONS: Although patient shielding has been used in radiological practice for many years, its use is no longer undisputed. The evaluation of the systematic literature review of recent studies and reports shows that dose savings are rather minimal while significant dose- and non-dose-related detrimental effects are present. Consequently, the routine usage of patient protection shielding in medical X-ray imaging can be safely discontinued for all modalities and patient groups.


Radiation Protection , Radiology , Child , Female , Fluoroscopy , Humans , Pregnancy , Radiation Dosage , Radiography , X-Rays
5.
J Cardiovasc Magn Reson ; 23(1): 94, 2021 07 12.
Article En | MEDLINE | ID: mdl-34247640

BACKGROUND: The native balanced steady state with free precession (bSSFP) magnetic resonance angiography (MRA) technique has been shown to provide high diagnostic image quality for thoracic aortic disease. This study compares a 3D radial respiratory self-navigated native MRA (native-SN-MRA) based on a bSSFP sequence with conventional Cartesian, 3D, contrast-enhanced MRA (CE-MRA) with navigator-gated respiration control for image quality of the entire thoracic aorta. METHODS: Thirty-one aortic native-SN-MRA were compared retrospectively (63.9 ± 10.3 years) to 61 CE-MRA (63.1 ± 11.7 years) serving as a reference standard. Image quality was evaluated at the aortic root/ascending aorta, aortic arch and descending aorta. Scan time was recorded. In 10 patients with both MRA sequences, aortic pathologies were evaluated and normal and pathologic aortic diameters were measured. The influence of artifacts on image quality was analyzed. RESULTS: Compared to the overall image quality of CE-MRA, the overall image quality of native-SN-MRA was superior for all segments analyzed (aortic root/ascending, p < 0.001; arch, p < 0.001, and descending, p = 0.005). Regarding artifacts, the image quality of native-SN-MRA remained superior at the aortic root/ascending aorta and aortic arch before and after correction for confounders of surgical material (i.e., susceptibility-related artifacts) (p = 0.008 both) suggesting a benefit in terms of motion artifacts. Native-SN-MRA showed a trend towards superior intraindividual image quality, but without statistical significance. Intraindividually, the sensitivity and specificity for the detection of aortic disease were 100% for native-SN-MRA. Aortic diameters did not show a significant difference (p = 0.899). The scan time of the native-SN-MRA was significantly reduced, with a mean of 05:56 ± 01:32 min vs. 08:51 ± 02:57 min in the CE-MRA (p < 0.001). CONCLUSIONS: Superior image quality of the entire thoracic aorta, also regarding artifacts, can be achieved with native-SN-MRA, especially in motion prone segments, in addition to a shorter acquisition time.


Aorta, Thoracic , Aortic Diseases , Aorta, Thoracic/diagnostic imaging , Aortic Diseases/diagnostic imaging , Contrast Media , Humans , Imaging, Three-Dimensional , Magnetic Resonance Angiography , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies
6.
Radiology ; 299(1): 150-158, 2021 04.
Article En | MEDLINE | ID: mdl-33620288

Background Often used for T1 mapping of hip cartilage, three-dimensional (3D) dual-flip-angle (DFA) techniques are highly sensitive to flip angle variations related to B1 inhomogeneities. The authors hypothesized that 3D magnetization-prepared 2 rapid gradient-echo (MP2RAGE) MRI would help provide more accurate T1 mapping of hip cartilage at 3.0 T than would 3D DFA techniques. Purpose To compare 3D MP2RAGE MRI with 3D DFA techniques using two-dimensional (2D) inversion recovery T1 mapping as a standard of reference for hip cartilage T1 mapping in phantoms, healthy volunteers, and participants with hip pain. Materials and Methods T1 mapping at 3.0 T was performed in phantoms and in healthy volunteers using 3D MP2RAGE MRI and 3D DFA techniques with B1 field mapping for flip angle correction. Participants with hip pain prospectively (July 2019-January 2020) underwent indirect MR arthrography (with intravenous administration of 0.2 mmol/kg of gadoterate meglumine), including 3D MP2RAGE MRI. A 2D inversion recovery-based sequence served as a T1 reference in phantoms and in participants with hip pain. In healthy volunteers, cartilage T1 was compared between 3D MP2RAGE MRI and 3D DFA techniques. Paired t tests and Bland-Altman analysis were performed. Results Eleven phantoms, 10 healthy volunteers (median age, 27 years; range, 26-30 years; five men), and 20 participants with hip pain (mean age, 34 years ± 10 [standard deviation]; 17 women) were evaluated. In phantoms, T1 bias from 2D inversion recovery was lower for 3D MP2RAGE MRI than for 3D DFA techniques (mean, 3 msec ± 11 vs 253 msec ± 85; P < .001), and, unlike 3D DFA techniques, the deviation found with MP2RAGE MRI did not correlate with increasing B1 deviation. In healthy volunteers, regional cartilage T1 difference (109 msec ± 163; P = .008) was observed only for the 3D DFA technique. In participants with hip pain, the mean T1 bias of 3D MP2RAGE MRI from 2D inversion recovery was -23 msec ± 31 (P < .001). Conclusion Compared with three-dimensional (3D) dual-flip-angle techniques, 3D magnetization-prepared 2 rapid gradient-echo MRI enabled more accurate T1 mapping of hip cartilage, was less affected by B1 inhomogeneities, and showed high accuracy against a T1 reference in participants with hip pain. © RSNA, 2021.


Cartilage, Articular/diagnostic imaging , Hip Joint/diagnostic imaging , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Adult , Contrast Media , Female , Gadolinium DTPA , Healthy Volunteers , Humans , Male , Pain Measurement , Phantoms, Imaging , Prospective Studies
7.
Invest Radiol ; 55(1): 53-59, 2020 01.
Article En | MEDLINE | ID: mdl-31633573

OBJECTIVES: The aim of this study was to evaluate the significance of a new imaging sign, the "cloverleaf sign," in diagnosing deep infiltrating endometriosis (DIE) with magnetic resonance imaging (MRI) in concordance to intraoperative findings. MATERIALS AND METHODS: This retrospective study included 103 patients operated during the January 2016 to June 2018 period with preoperative 1.5 T and 3 T MRI, with or without vaginal and rectal gel filling. Magnetic resonance imaging scans were read blinded to intraoperative findings by a specialized gynecologic radiologist and a junior radiologist, and then compared with intraoperative findings by looking at the operation report, postoperative diagnosis, and intraoperative images and videos by an experienced gynecologist surgeon specialized in endometriosis surgery. All endometriosis lesions were confirmed by pathology. The "cloverleaf sign" was defined as a cloverleaf-like figure in imaging morphology; the "leaves" formed by at least 3 different organs come together in the center of the figure formed by constrictive adhesions including T2-weighted (T2W) hypointense DIE. Operation times, intraoperative blood loss, and the frequency of DIE and bowel resections were analyzed in cloverleaf and noncloverleaf groups. The 2-sample Wilcoxon rank-sum (Mann-Whitney U) test and multivariate analysis of variance were used to calculate the significance of an overall impact of cloverleaf sign on operation time, blood loss, and the amount of the bowel resection rate. P < 0.05 was considered statistically significant. RESULTS: The prevalence of DIE in the study population was 79.6%. A total of 11.5% of the patients had no endometriosis, 32.6% had rASRM I and II, and 55.9% had rASRM III and IV. Forty-six patients (45%) had received rectal and vaginal gel opacification before scanning, 57 (55%) did not. A cloverleaf sign on MRI was detected in 34 patients (15 in gel filling and 19 in nonfilling group). The interreader agreement was almost perfect 0.91 (κ). The median operation time in the cloverleaf group was 248 minutes (interquartile range [IQR], 165-330) compared with 145 minutes in the noncloverleaf group (IQR, 90-210), that is, significantly higher (P < 0.001). Intraoperative blood loss was also significantly higher in the conglomerate group (125 vs 50 mL; IQR, 100-300 vs 50-100; P < 0.001). Of the bowel resections in our study population, 41% (14/34) were performed on patients with a cloverleaf sign in the MRI, compared with 13% (9/69) in patients without the cloverleaf sign. CONCLUSIONS: The "cloverleaf" MRI sign was associated with significantly longer operation time, increased intraoperative blood loss, and higher rates of bowel resection in DIE patients.


Blood Loss, Surgical/statistics & numerical data , Endometriosis/diagnostic imaging , Endometriosis/surgery , Intestines/surgery , Magnetic Resonance Imaging/methods , Operative Time , Adult , Female , Humans , Pelvis/diagnostic imaging , Retrospective Studies
8.
Eur J Radiol ; 118: 66-74, 2019 Sep.
Article En | MEDLINE | ID: mdl-31439261

PURPOSE: To show that both susceptibility-weighted imaging (SWI) and T2*-mapping are dependent on liver steatosis, which should be taken into account when using these parameters to grade liver fibrosis and cirrhosis. METHODS: In this prospective study, a total of 174 patients without focal liver disease underwent multiparametric MRI at 3 T including SWI, T1- and T2* mapping, proton density fat fraction (PDFF) quantification and MR elastography. SWI, T2* and T1 were measured in the liver (4 locations), as well as in paraspinal muscles, to calculate the liver-to-muscle ratio (LMR). Liver and LMR values were compared among patients with different steatosis grades (PDFF < 5%, 5-10%, 10-20% and >20%), patients with normal, slightly increased and increased liver stiffness (<2.8 kPa, 2.8-3.5 kPa and >3.5 kPa, respectively). ANOVA with Bonferroni-corrected post hoc tests as well as a multivariate analysis were used to compare values among groups and parameters. RESULTS: SWI and T2* both differed significantly among groups with different steatosis grades (p < 0.001). However, SWI allowed a better differentiation among liver fibrosis grades (p < 0.001) than did T2* (p = 0.05). SWI LMR (p < 0.001) and T2* LMR (p = 0.036) showed a similar performance in differentiating among liver fibrosis grades. CONCLUSION: SWI and T2*-mapping are strongly dependent on the liver steatosis grades. Nevertheless, both parameters are useful predictors for liver fibrosis when using a multiparametric approach.


Fatty Liver/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Liver Cirrhosis/diagnostic imaging , Magnetic Resonance Imaging/methods , Cross-Sectional Studies , Female , Humans , Liver/diagnostic imaging , Male , Middle Aged , Prospective Studies
9.
Eur Radiol ; 28(6): 2389-2396, 2018 Jun.
Article En | MEDLINE | ID: mdl-29302785

OBJECTIVES: To investigate prospectively the repeatability of pancreatic perfusion measurements using arterial spin labelling (ASL) and to determine the increase in perfusion due to secretin stimulation. MATERIAL AND METHODS: An (FAIR)-TrueFISP ASL sequence was applied to determine the perfusion of the pancreatic head in a 3T MRI scanner. Ten healthy volunteers (four men, six women: mean age 28.5 ± 4.6 years; age range 25-40 years) were investigated twice within 1 week. The inter-individual variability was calculated using the standard deviation. Intra-individual agreement between the first and second scan was estimated using the Pearson correlation coefficient. A paired Wilcoxon rank-sum test was used to compare perfusion at baseline (BL) and during secretin stimulation. RESULTS: The mean BL perfusion of the pancreatic head was 285 ± 96 mL/100 g/min with an intra-individual correlation coefficient of 0.67 (strong) for repeated measurements. Secretin stimulation led to a significant increase (by 81%) in perfusion of the pancreatic head to 486 ±156 mL/100 g/min (p=0.002) with an intra-individual correlation of 0.29 (weak). A return to BL values was observed after 239 ± 92 s with a moderate intra-individual correlation coefficient of 0.42 for repeat measurements. CONCLUSION: Dynamic non-invasive ASL imaging of the pancreas permitted quantification of pancreatic perfusion in a clinically applicable setting. KEY POINTS: • ASL imaging of the pancreas permitted quantification of pancreatic perfusion • Secretin stimulation led to a significant increase in pancreatic perfusion • The intra-individual correlation coefficient for baseline perfusion was strong for repeated measurements.


Magnetic Resonance Imaging/methods , Pancreas/diagnostic imaging , Secretin/metabolism , Adult , Female , Humans , Male , Pancreas/blood supply , Pancreas/metabolism , Reference Values
10.
Eur Radiol ; 27(10): 4336-4344, 2017 Oct.
Article En | MEDLINE | ID: mdl-28374076

OBJECTIVES: To assess retrospectively whether diffusion-weighted magnetic resonance imaging (DW-MRI) allows physicians to determine the severity of histopathologic findings in biopsies of renal allograft patients with deteriorating renal function. METHODS: Forty consecutive kidney transplant patients underwent DW-MRI and biopsy. Patients were assigned to one group with severe and to another group with normal or mild histopathologic findings. These two groups were compared based on a qualitative DW-MRI assessment (homo-/heterogeneity) and the combination of qualitative and quantitative DW-MRI parameters (ADC, and intravoxel incoherent motion, IVIM, parameters: D, f, D*). Sensitivity, specificity, and accuracy were determined for each parameter. RESULTS: Biopsy findings were severe in 25 patients and normal or mild in 15 patients. Qualitative DW-MRI led to a sensitivity of 44.0% and a specificity of 93.3%. Combined qualitative and quantitative DW-MRI led to an accuracy of 80% for both the minimal ADC (ADCmin) and the minimal perfusion fraction (fmin) with a sensitivity of 84.0% and 92.0% and a specificity of 73.3% and 60.0%, respectively. CONCLUSION: Combined qualitative and quantitative DW-MRI might allow physicians to determine the severity of histopathologic findings in biopsies of a high number of kidney transplant patients. KEY POINTS: • Qualitative DW-MRI is highly specific when predicting the severity of kidney transplant biopsy. • Allografts appearing heterogeneous on ADC are associated with severe histopathologic findings. • Combining qualitative and quantitative DW-MRI parameters improves the classification's sensitivity and accuracy. • Kidney transplant biopsies might be spared by combining qualitative and quantitative DW-MRI.


Biopsy , Diffusion Magnetic Resonance Imaging , Echo-Planar Imaging , Kidney Transplantation , Kidney/pathology , Adult , Aged , Female , Humans , Male , Middle Aged , Motion , Perfusion , Retrospective Studies , Sensitivity and Specificity
11.
J Thorac Cardiovasc Surg ; 150(1): 200-7, 2015 Jul.
Article En | MEDLINE | ID: mdl-25840754

OBJECTIVES: Left ventricular assist devices are an important treatment option for patients with heart failure alter the hemodynamics in the heart and great vessels. Because in vivo magnetic resonance studies of patients with ventricular assist devices are not possible, in vitro models represent an important tool to investigate flow alterations caused by these systems. By using an in vitro magnetic resonance-compatible model that mimics physiologic conditions as close as possible, this work investigated the flow characteristics using 4-dimensional flow-sensitive magnetic resonance imaging of a left ventricular assist device with outflow via the right subclavian artery as commonly used in cardiothoracic surgery in the recent past. METHODS: An in vitro model was developed consisting of an aorta with its supra-aortic branches connected to a left ventricular assist device simulating the pulsatile flow of the native failing heart. A second left ventricular assist device supplied the aorta with continuous flow via the right subclavian artery. Four-dimensional flow-sensitive magnetic resonance imaging was performed for different flow rates of the left ventricular assist device simulating the native heart and the left ventricular assist device providing the continuous flow. Flow characteristics were qualitatively and quantitatively evaluated in the entire vessel system. RESULTS: Flow characteristics inside the aorta and its upper branching vessels revealed that the right subclavian artery and the right carotid artery were solely supported by the continuous-flow left ventricular assist device for all flow rates. The flow rates in the brain-supplying arteries are only marginally affected by different operating conditions. The qualitative analysis revealed only minor effects on the flow characteristics, such as weakly pronounced vortex flow caused by the retrograde flow via the brachiocephalic artery. CONCLUSIONS: The results indicate that, despite the massive alterations in natural hemodynamics due to the retrograde flow via the right subclavian and brachiocephalic arteries, there are no drastic consequences on the flow in the brain-feeding arteries and the flow characteristics in the ascending and descending aortas. It may be beneficial to adjust the operating condition of the left ventricular assist device to the residual function of the failing heart.


Heart-Assist Devices , Hemodynamics , Magnetic Resonance Imaging/methods , Models, Cardiovascular , Subclavian Artery/physiology
12.
NMR Biomed ; 27(11): 1285-92, 2014 Nov.
Article En | MEDLINE | ID: mdl-25181700

(1) H-MRS is regularly applied to determine lipid content in ectopic tissue - mostly skeletal muscle and liver - to investigate physiological and/or pathologic conditions, e.g. insulin resistance. Technical developments also allow non-invasive in vivo assessment of cardiac lipids; however, basic data about methodological reliability (repeatability) and physiological variations are scarce. The aim of the presented work was to determine potential diurnal changes of cardiac lipid stores in humans, and to put the results in relation to methodological repeatability and normal physiological day-to-day variations. Optimized cardiac- and respiratory-gated (1) H-MRS was used for non-invasive quantification of intracardiomyocellular lipids (ICCL), creatine, trimethyl-ammonium compounds (TMA), and taurine in nine healthy young men at three time points per day on two days separated by one week. This design allowed determination of (a) diurnal changes, (b) physiological variation over one week and (c) methodological repeatability of the ICCL levels. Comparison of fasted morning to post-absorptive evening measurements revealed a significant 37 ± 19% decrease of ICCL during the day (p = 0.0001). There was a significant linear correlation between ICCL levels in the morning and their decrease during the day (p = 0.015). Methodological repeatability for the ICCL/creatine ratio was excellent, with a coefficient of variance of ~5%, whereas physiological variation was found to be considerably higher (22%) in spite of a standardized physiological preparation protocol. In contrast, TMA levels remained stable over this time period. The proposed (1) H-MRS technique provides a robust way to investigate relevant physiological changes in cardiac metabolites, in particular ICCL. The present results suggest that ICCL reveal a diurnal course, with higher levels in the morning as compared to evening. In addition, a considerable long-term variation of ICCL levels, in both the morning and evening, was documented. Given the high methodological repeatability, these effects should be taken into account in studies investigating the metabolic role of ICCL.


Circadian Rhythm , Lipid Metabolism , Lipids/analysis , Myocardium/metabolism , Proton Magnetic Resonance Spectroscopy , Adult , Creatine/analysis , Fasting , Humans , Male , Myocardium/chemistry , Myocytes, Cardiac/chemistry , Postprandial Period , Quaternary Ammonium Compounds/analysis , Reference Values , Reproducibility of Results , Taurine/analysis
13.
Diabetologia ; 57(5): 1001-5, 2014 May.
Article En | MEDLINE | ID: mdl-24563325

AIMS/HYPOTHESIS: Ectopic lipids are fuel stores in non-adipose tissues (skeletal muscle [intramyocellular lipids; IMCL], liver [intrahepatocellular lipids; IHCL] and heart [intracardiomyocellular lipids; ICCL]). IMCL can be depleted by physical activity. Preliminary data suggest that aerobic exercise increases IHCL. Data on exercise-induced changes on ICCL is scarce. Increased IMCL and IHCL have been related to insulin resistance in skeletal muscles and liver, whereas this has not been documented in the heart. The aim of this study was to assess the acute effect of aerobic exercise on the flexibility of IMCL, IHCL and ICCL in insulin-sensitive participants in relation to fat availability, insulin sensitivity and exercise capacity. METHODS: Healthy physically active men were included. VO(2max) was assessed by spiroergometry and insulin sensitivity was calculated using the HOMA index. Visceral and subcutaneous fat were separately quantified by MRI. Following a standardised dietary fat load over 3 days, IMCL, IHCL and ICCL were measured using MR spectroscopy before and after a 2 h exercise session at 50-60% of VO(2max). Metabolites were measured during exercise. RESULTS: Ten men (age 28.9 ± 6.4 years, mean ± SD; VO(2max) 56.3 ± 6.4 ml kg(-1) min(-1); BMI 22.75 ± 1.4 kg/m(2)) were recruited. A 2 h exercise session resulted in a significant decrease in IMCL (-17 ± 22%, p = 0.008) and ICCL (-17 ± 14%, p = 0.002) and increase in IHCL (42 ± 29%, p = 0.004). No significant correlations were found between the relative changes in ectopic lipids, fat availability, insulin sensitivity, exercise capacity or changes of metabolites during exercise. CONCLUSIONS/INTERPRETATION: In this group, physical exercise decreased ICCL and IMCL but increased IHCL. Fat availability, insulin sensitivity, exercise capacity and metabolites during exercise are not the only factors affecting ectopic lipids during exercise.


Exercise/physiology , Lipids/analysis , Liver/metabolism , Muscle, Skeletal/metabolism , Myocardium/metabolism , Adult , Humans , Insulin/blood , Insulin/metabolism , Insulin Resistance , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Male , Middle Aged , Postprandial Period , Rest , Time Factors , Young Adult
14.
Eur J Radiol ; 81(4): e502-6, 2012 Apr.
Article En | MEDLINE | ID: mdl-21703795

OBJECTIVE: Comparison of arterial and venous coronary artery bypass flow measurements using 3-T magnetic resonance (MR) phase contrast in correlation with intraoperative Doppler flow measurements. METHODS: Fifty-six coronary bypasses (right coronary artery n=18, left internal mammary artery to left anterior descending artery n=16, marginal artery n=7, circumflex artery n=7, diagonal artery n=6, left anterior descending artery n=1, and right internal mammary artery to right coronary artery n=1) were studied in 27 asymptomatic patients. In this prospective study, each bypass was studied intra-operatively using Doppler flow measurement. Within one week post surgery, patients were studied using a 3-T MR scanner (Magnetom Verio, Siemens, Erlangen, Germany) using velocity encoded phase-contrast flow measurements. RESULTS: Intraoperative Doppler flow measurements demonstrated regular flow patterns in all vascular territories supplied. All bypasses were patent on MRI and flow measurement results were as follows: median flow 60ml/min (interquartile range (IQR): 37.5-78.5ml/min). For comparison, the corresponding median intraoperative flow was 58ml/min (IQR: 41-80ml/min) (p<0.001; R=0.44). Linear regression analysis demonstrated a significant correlation for venous bypasses (p=0.0002; R=0.48), but not for arterial bypasses (p=0.09; R=0.24). CONCLUSION: This study demonstrated that MR flow measurements of venous bypass grafts agreed more with Doppler than arterial bypass grafts. However, bypass patency was confirmed for all patients. In the future, this technique may be used for non invasive coronary bypass graft follow-up.


Arteries/transplantation , Coronary Artery Bypass/methods , Coronary Artery Disease/physiopathology , Coronary Artery Disease/surgery , Coronary Circulation , Magnetic Resonance Angiography/methods , Saphenous Vein/transplantation , Aged , Aged, 80 and over , Blood Flow Velocity , Coronary Artery Disease/pathology , Female , Humans , Male , Middle Aged , Saphenous Vein/physiopathology , Treatment Outcome
15.
Eur J Radiol ; 81(5): 979-84, 2012 May.
Article En | MEDLINE | ID: mdl-21377307

INTRODUCTION: Preoperative mapping of the arterial spinal supply prior to thoracoabdominal aortic aneurysm repair is highly relevant because of high risk for postoperative ischemic spinal cord injuries such as paraparesis or paraplegia. METHODS: Twenty-four consecutive patients prior to surgical thoracoabdominal aortic aneurysm repair were investigated. All patients underwent steady-state MR angiography (MRA) of the spinal vasculature with 3-T MRI. The sequence used was a steady-state coronary 3D FLASH with 0.7-mm isotropic voxels. MRA was performed using an intravasal contrast agent. Studies were evaluated by three readers including delineation of arterial spinal supply including both aortic origin and spinal canal entry by three readers. RESULTS: Identification and localization of the Adamkiewicz artery and its spinal canal entry was successful in all patients. Overall depiction of the vascular anatomy was graded as very good in 3 (12.5%), good in 14 (58.4%), sufficient in 5 (20.8%), and poor in 2 (8.3%) patients. Depiction of segmental artery aortic exit level was graded as good in 6 (25.0%), sufficient in 10 (41.7%), poor in 4 (16.7%) and not identifiable in 4 (16.7%) patients. Delineation of segmental artery entry level into the spinal canal was graded as very good in 4 (16.7%), good in 11 (45.8%), sufficient in 6 (25.0%), and poor in 3 (12.5%) patients. CONCLUSIONS: The use of 3-T MRA with an intravascular contrast agent and steady-state enables AKA localization including its segmental arteries with regard to the level of aortic origin and spinal canal entry in most patients.


Aortic Aneurysm/pathology , Aortic Aneurysm/surgery , Arteries/pathology , Gadolinium , Magnetic Resonance Angiography/methods , Organometallic Compounds , Spinal Cord/blood supply , Spinal Cord/pathology , Adult , Aged , Contrast Media/administration & dosage , Female , Gadolinium/administration & dosage , Humans , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Injections, Intra-Arterial , Male , Middle Aged , Organometallic Compounds/administration & dosage , Preoperative Care/methods , Reproducibility of Results , Sensitivity and Specificity
16.
NMR Biomed ; 24(7): 791-8, 2011 Aug.
Article En | MEDLINE | ID: mdl-21834003

Standard methods for the estimation of the postmortem interval (PMI, time since death), based on the cooling of the corpse, are limited to about 48 h after death. As an alternative, noninvasive postmortem observation of alterations of brain metabolites by means of (1)H MRS has been suggested for an estimation of the PMI at room temperature, so far without including the effect of other ambient temperatures. In order to study the temperature effect, localized (1)H MRS was used to follow brain decomposition in a sheep brain model at four different temperatures between 4 and 26°C with repeated measurements up to 2100 h postmortem. The simultaneous determination of 25 different biochemical compounds at each measurement allowed the time courses of concentration changes to be followed. A sudden and almost simultaneous change of the concentrations of seven compounds was observed after a time span that decreased exponentially from 700 h at 4°C to 30 h at 26°C ambient temperature. As this represents, most probably, the onset of highly variable bacterial decomposition, and thus defines the upper limit for a reliable PMI estimation, data were analyzed only up to this start of bacterial decomposition. As 13 compounds showed unequivocal, reproducible concentration changes during this period while eight showed a linear increase with a slope that was unambiguously related to ambient temperature. Therefore, a single analytical function with PMI and temperature as variables can describe the time courses of metabolite concentrations. Using the inverse of this function, metabolite concentrations determined from a single MR spectrum can be used, together with known ambient temperatures, to calculate the PMI of a corpse. It is concluded that the effect of ambient temperature can be reliably included in the PMI determination by (1)H MRS.


Magnetic Resonance Spectroscopy/methods , Postmortem Changes , Protons , Temperature , Animals , Body Temperature , Brain/metabolism , Brain/pathology , Cadaver , Humans , Models, Biological , Sheep , Time Factors
17.
Physiol Genomics ; 43(12): 739-48, 2011 Jun 28.
Article En | MEDLINE | ID: mdl-21447747

We hypothesized that network analysis is useful to expose coordination between whole body and myocellular levels of energy metabolism and can identify entities that underlie skeletal muscle's contribution to growth hormone-stimulated lipid handling and metabolic fitness. We assessed 112 metabolic parameters characterizing metabolic rate and substrate handling in tibialis anterior muscle and vascular compartment at rest, after a meal and exercise with growth hormone replacement therapy (GH-RT) of hypopituitary patients (n = 11). The topology of linear relationships (| r | ≥ 0.7, P ≤ 0.01) and mutual dependencies exposed the organization of metabolic relationships in three entities reflecting basal and exercise-induced metabolic rate, triglyceride handling, and substrate utilization in the pre- and postprandial state, respectively. GH-RT improved aerobic performance (+5%), lean-to-fat mass (+19%), and muscle area of tibialis anterior (+2%) but did not alter its mitochondrial and capillary content. Concomitantly, connectivity was established between myocellular parameters of mitochondrial lipid metabolism and meal-induced triglyceride handling in serum. This was mediated via the recruitment of transcripts of muscle lipid mobilization (LIPE, FABP3, and FABP4) and fatty acid-sensitive transcription factors (PPARA, PPARG) to the metabolic network. The interdependence of gene regulatory elements of muscle lipid metabolism reflected the norm in healthy subjects (n = 12) and distinguished the regulation of the mitochondrial respiration factor COX1 by GH and endurance exercise. Our observations validate the use of network analysis for systems medicine and highlight the notion that an improved stochiometry between muscle and whole body lipid metabolism, rather than alterations of single bottlenecks, contributes to GH-driven elevations in metabolic fitness.


Energy Metabolism/physiology , Exercise Therapy/methods , Homeostasis/physiology , Hormone Replacement Therapy/methods , Human Growth Hormone/pharmacology , Hypopituitarism/drug therapy , Hypopituitarism/therapy , Muscle, Skeletal/physiology , Adult , Basal Metabolism , Blood Chemical Analysis , Calorimetry, Indirect , Energy Metabolism/drug effects , Human Growth Hormone/administration & dosage , Humans , Microarray Analysis , Middle Aged , Muscle, Skeletal/drug effects , Physical Endurance/drug effects , Postprandial Period , Reverse Transcriptase Polymerase Chain Reaction , Statistics, Nonparametric , Triglycerides/blood
18.
Med Sci Sports Exerc ; 43(10): 1964-71, 2011 Oct.
Article En | MEDLINE | ID: mdl-21407126

PURPOSE: Both liver and muscle glycogen stores play a fundamental role in exercise and fatigue, but the effect of different CHO sources on liver glycogen synthesis in humans is unclear. The aim was to compare the effect of maltodextrin (MD) drinks containing galactose, fructose, or glucose on postexercise liver glycogen synthesis. METHODS: In this double-blind, triple crossover, randomized clinical trial, 10 well-trained male cyclists performed three experimental exercise sessions separated by at least 1 wk. After performing a standard exercise protocol to exhaustion, subjects ingested one of three 15% CHO solutions, namely, FRU (MD + fructose, 2:1), GAL (MD + galactose, 2:1), or GLU (MD + glucose, 2:1), each providing 69 g CHO·h(-1) during 6.5 h of recovery. Liver glycogen changes were followed using (13)C magnetic resonance spectroscopy. RESULTS: Liver glycogen concentration increased at faster rates with FRU (24 ± 2 mmol·L(-1)·h(-1), P < 0.001) and with GAL (28 ± 3 mmol·L(-1)·h(-1), P < 0.001) than with GLU (13 ± 2 mmol·L(-1)·h(-1)). Liver volumes increased (P < 0.001) with FRU (9% ± 2%) and with GAL (10% ± 2%) but not with GLU (2% ± 1%, NS). Net glycogen synthesis appeared linear and was faster with FRU (8.1 ± 0.6 g·h(-1), P < 0.001) and with GAL (8.6 ± 0.9 g·h(-1), P < 0.001) than with GLU (3.7 ± 0.5 g·h(-1)). CONCLUSIONS: When ingested at a rate designed to saturate intestinal CHO transport systems, MD drinks with added fructose or galactose were twice as effective as MD + glucose in restoring liver glycogen during short-term postexercise recovery.


Beverages , Bicycling/physiology , Dietary Carbohydrates/administration & dosage , Fructose/administration & dosage , Galactose/administration & dosage , Liver Glycogen/biosynthesis , Liver/drug effects , Adult , Exercise/physiology , Exercise Test , Humans , Liver/metabolism , Liver Glycogen/analysis , Magnetic Resonance Spectroscopy , Male , Physical Endurance/physiology
19.
Interact Cardiovasc Thorac Surg ; 12(4): 582-5, 2011 Apr.
Article En | MEDLINE | ID: mdl-21245126

Evaluation of a novel non-invasive tool for postoperative follow-up of patients postelective saphenous vein coronary artery bypass graft (CABG) was performed. Ten patients were included. Their bypass grafts supplied the right coronary artery (7), marginal branches (1), diagonal branches (2), and the circumflex artery (n=1). Each bypass was examined intraoperatively using Doppler flow measurement. Patients were examined with a 3-Tesla magnetic resonance imaging (MRI) scanner (MAGNETOM Verio, Siemens, Erlangen, Germany) within one week postsurgery using MR-angiography with an intravasal contrast agent and velocity encoded phase-contrast flow measurements. Intraoperative Doppler flow measurements revealed regular flow patterns in all vascular territories supplied. The median intraoperative flow rate was 50 ml/min with an inter-quartile range (IQR) of 42-70 ml/min. The clinical postoperative course was uneventful. MRI showed all grafts to be patent. The median postoperative flow rate was 50 ml/min (IQR: 32-65 ml/min). MRI flow rates agreed well with intraoperative Doppler flow measurements (mean difference: -2.8±20.1 ml/min). This initial study demonstrates that 3-Tesla MRI flow measurements correlated well with Doppler thus reconfirming the graft patency postCABG. Further refinement and broader application of this technique may facilitate follow-up postCABG potentially replacing empiric clinical judgment by reliable non-invasive imaging.


Coronary Artery Bypass , Graft Occlusion, Vascular/diagnosis , Magnetic Resonance Angiography , Saphenous Vein/transplantation , Aged , Aged, 80 and over , Blood Flow Velocity , Contrast Media , Coronary Artery Bypass/adverse effects , Coronary Circulation , Elective Surgical Procedures , Feasibility Studies , Gadolinium , Graft Occlusion, Vascular/physiopathology , Humans , Laser-Doppler Flowmetry , Male , Middle Aged , Organometallic Compounds , Pilot Projects , Predictive Value of Tests , Saphenous Vein/diagnostic imaging , Saphenous Vein/pathology , Saphenous Vein/physiopathology , Switzerland , Time Factors , Treatment Outcome , Ultrasonography , Vascular Patency
20.
Diabetes Care ; 34(1): 220-2, 2011 Jan.
Article En | MEDLINE | ID: mdl-20978101

OBJECTIVE: Intramyocellular acetylcarnitine (IMAC) is involved in exercise-related fuel metabolism. It is not known whether levels of systemic glucose influence IMAC levels in type 1 diabetes. RESEARCH DESIGN AND METHODS: Seven male individuals with type 1 diabetes performed 120 min of aerobic exercise at 55-60% of Vo(2max) randomly on two occasions (glucose clamped to 5 or 11 mmol/l, identical insulinemia). Before and after exercise, IMAC was detected by ¹H magnetic resonance spectroscopy in musculus vastus intermedius. RESULTS: Postexercise levels of IMAC were significantly higher than pre-exercise values in euglycemia (4.30 ± 0.54 arbitrary units [a.u.], P < 0.001) and in hyperglycemia (2.44 ± 0.53 a.u., P = 0.01) and differed significantly according to glycemia (P < 0.01). The increase in exercise-related levels of IMAC was significantly higher in euglycemia (3.97 ± 0.45 a.u.) than in hyperglycemia (1.71 ± 0.50 a.u.; P < 0.01). CONCLUSIONS: The increase in IMAC associated with moderate aerobic exercise in individuals with type 1 diabetes was significantly higher in euglycemia than in hyperglycemia.


Acetylcarnitine/metabolism , Diabetes Mellitus, Type 1/metabolism , Exercise/physiology , Hyperglycemia/metabolism , Muscles/metabolism , Cross-Over Studies , Humans , Magnetic Resonance Spectroscopy , Male , Single-Blind Method
...