Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Diagn Interv Imaging ; 98(12): 843-848, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28647478

RESUMEN

PURPOSE: To evaluate the safety and efficacy of pelvic embolization using ethylene vinyl alcohol copolymer (Onyx®) for pelvic congestion syndrome. MATERIAL AND METHODS: Between March 2012 to September 2016, 17 women (mean age, 44.7± 12.2 (SD) years; range: 34-71years) presenting with pelvic congestion syndrome were evaluated for transvenous embolization with Onyx®. Pelvic congestion syndrome was initially diagnosed by clinical examination and the results of transvaginal Doppler ultrasound and further confirmed by pelvic venography. Primary and secondary clinical efficacy was defined respectively by the resolution of the symptoms after embolization and at the end of the follow-up, irrespective to the number of embolization procedures. RESULTS: Technical efficacy of embolization was 100% with no significant complications during and after embolization. After a mean follow-up time of 24.2 months (range: 6-69months) a primary and secondary clinical efficacy of 76.4% (13/17 women) and 94.1% (16/17 women) respectively were observed. Four women (23.5%) underwent a second embolization procedure with one woman requiring a third embolization procedure. These additional embolization procedures were associated with direct puncture of vulvar varices for sclerotherapy in two women. Five women (29%) had recurrent symptoms 21 months post-treatment (7-42months). CONCLUSION: Pelvic embolization using ethylene vinyl alcohol copolymer (Onyx®) has a favorable clinical success for pelvic congestion syndrome.


Asunto(s)
Quimioembolización Terapéutica , Ovario/irrigación sanguínea , Polivinilos/administración & dosificación , Várices/terapia , Venas , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Pelvis/irrigación sanguínea , Síndrome , Resultado del Tratamiento
4.
Diagn Interv Imaging ; 98(5): 415-421, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27776896

RESUMEN

PURPOSE: The purpose of this study was to evaluate the effectiveness of ethylene vinyl alcohol copolymer (Onyx) as a single embolic agent for percutaneous arterial treatment of hemorrhage due to uterine arteriovenous malformations (AVMs). MATERIALS AND METHODS: Twelve women (mean age, 33 years) with metrorrhagia due to uterine AVMs who were treated by percutaneous arterial embolization using Onyx as a single embolic agent were retrospectively included. The diagnosis of uterine AVM was suggested by pelvic ultrasound and/or magnetic resonance imaging findings and further confirmed by angiography. Clinical files and angiographic examinations were reviewed for angiographic findings, technical and clinical success, procedure complication and further pregnancies. Clinical success was defined by absence of metrorrhagia at 1 month following embolization. RESULTS: Sixteen arterial embolization procedures were performed. Angiographically, 6 women had high flow AVM and 6 had low flow AVM. The rate of technical and clinical success was 92% (11/12 patients). One woman with early repeat hemorrhage underwent two embolization procedures and further hysterectomy. No severe complications were observed after embolization. Three women (3/12; 25%) became pregnant following embolization including one full term pregnancy. CONCLUSION: In women with metrorrhagia due to AVM, arterial embolization with Onyx is effective and safe. Additional research is needed to confirm the possibility of future pregnancy after Onyx embolization.


Asunto(s)
Malformaciones Arteriovenosas/complicaciones , Embolización Terapéutica/métodos , Hemorragia/etiología , Hemorragia/terapia , Polivinilos/administración & dosificación , Útero/irrigación sanguínea , Adulto , Cateterismo , Femenino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Procedimientos Quirúrgicos Vasculares , Adulto Joven
5.
Diagn Interv Imaging ; 97(11): 1109-1116, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27475313

RESUMEN

PURPOSE: The goal of this study was to assess the distal dispersion, the adhesion strength to catheter, the vascular toxicity and the ability in excluding embolized vessels using Purefill® (α-hexil-cyanoacrylate) as embolic material, which is a new high purity cyanoacrylate and compare these results with those obtained with N-butyl-2-cyanoacrylate (Histoacryl®) and a mixture of N-butyl-2-cyanoacrylate and methacryloxysulfolane. MATERIAL AND METHODS: In six pigs, the right rete mirabile (RM) and right renal arteries were embolized with α-hexil-cyanoacrylate, and the left rete mirabile and left renal artery were embolized with N-butyl-2-cyanoacrylate and N-butyl-2-cyanoacrylate+Methacryloxysulfolane for comparison. One minute after glue injection through the microcatheter, displacements of the kidney and the pharyngeal artery were measured on angiographic images, before exercising any traction and during catheter pulling, when the forces were maximal. Displacement was measured in terms of distance (mm) with respect to renal pedicles and in terms of angle (°) with respect to the rete. After acute embolization (4 pigs) or three-month follow-up (2 pigs), the kidneys and the RM were removed and further analysed using computed tomography and histopathological examination. RESULTS: Similar short and long-term embolic efficacies were observed with the three glues. The mean displacement distances of renal pedicles were 2.6mm for α-hexil-cyanoacrylate, 22.6mm for N-butyl-2-cyanoacrylate and 19.8mm for N-butyl-2-cyanoacrylate+Methacryloxysulfolane (P=0.021). The mean angles of displacement of the ascending pharyngeal arteries were for 12.2° for α-hexil-cyanoacrylate, 23.5° for N-butyl-2-cyanoacrylate and 30° for N-butyl-2-cyanoacrylate+Methacryloxysulfolane (P=0.070). Histopathologically, findings were similar for the three glues, immediately and 90 days after embolization. CONCLUSION: α-hexil-cyanoacrylate has occlusive efficacy in the short and long term similar to those of N-butyl-2-cyanoacrylate and N-butyl-2-cyanoacrylate+Methacryloxysulfolane. In addition, histopathological changes are similar with the three glues immediately or 90 days after embolization. Conversely, α-hexil-cyanoacrylate results in a reduced angle and distance of displacement compared to the other two glues, assumably reflecting a limited adhesive strength.


Asunto(s)
Cianoacrilatos , Modelos Animales de Enfermedad , Embolización Terapéutica/métodos , Animales , Riñón/irrigación sanguínea , Arteria Renal , Porcinos , Resultado del Tratamiento
7.
Diagn Interv Imaging ; 96(4): 319-26, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25704146

RESUMEN

Onyx(®) is a remarkable liquid embolizing agent that may allow a well-trained operator to undertake challenging embolization procedures. In multiple interventional radiology indications, the physico-chemical properties of Onyx(®) allow safe embolization. The purpose of this article is to review the advantages and disadvantages of Onyx(®) and identify its main indications.


Asunto(s)
Embolización Terapéutica , Polivinilos , Radiología Intervencionista , Humanos , Polivinilos/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...