Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
Cornea ; 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38985894

RESUMEN

PURPOSE: Positive vitreous pressure (PVP) secondary to intraoperative acute hypotony during penetrating keratoplasty can result in extrusion of the intraocular lens and vitreous. Currently described techniques are difficult or impossible to apply intraoperatively when positive vitreous pressure is noticed in an "open sky" situation after excision of the host corneal button. METHODS: We describe a technique where pupil scaffolding is used to prevent intraocular lens or crystalline lens extrusion by simply closing the pupil with a temporary suture that holds the retropupillary contents back. Once the eye is thus stabilized, the donor cornea is sutured rapidly after which the pupillary knot is cut and removed using microscissors and microforceps. RESULTS: Five patients undergoing penetrating keratoplasty under peribulbar anesthesia underwent this technique after experiencing PVP after host corneal button excision. PVP was successfully controlled in all 5 patients, and the optical grafts remained clear in the postoperative period. CONCLUSIONS: Temporary pupillary scaffolding can help control PVP and prevent ocular content extrusion during PKP surgeries.

2.
Cornea ; 43(3): 398-401, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38315501

RESUMEN

ABSTRACT: Corneal allogeneic intrastromal ring segments (CAIRS) refer to the placement of allogeneic rings and segments in intrastromal channels within the cornea. Currently, a deepithelialized donor cornea is used as the allogeneic source for CAIRS and the cut ring is turned sideways and implanted so that the thickness can be varied by varying the distance between the concentric trephine blades. In addition, to obtain a greater effect, CAIRSs are preferred to be implanted with the Bowman layer (BL) facing the corneal apex and posterior stroma facing limbally. Being flexible tissue, it is, however, important to prevent twisting and to maintain correct orientation. We describe a simple technique of marking the BL with a gentian violet surgical marker to simplify CAIRS insertion. BL marking allows easy visibility of twists and helps identify improper orientation, thus allowing correct insertion of CAIRS.


Asunto(s)
Trasplante de Células Madre Hematopoyéticas , Queratocono , Humanos , Sustancia Propia/cirugía , Córnea/cirugía , Prótesis e Implantes , Implantación de Prótesis , Topografía de la Córnea , Queratocono/cirugía
3.
J Refract Surg ; 39(12): 856-862, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38063823

RESUMEN

PURPOSE: To describe a novel technique for cutting asymmetric allogenic segments using the femtosecond laser for the management of cases of keratoconus with non-coinciding astigmatism and coma axes. METHODS: Four eyes of 2 patients with irregular keratoconus and asymmetric allogenic segments were included. Visual, refractive, tomographic, and aberrometric outcomes, and optical coherence tomography (OCT) sections were measured preoperatively and 6 months postoperatively. Evaluations included slit-lamp examination, manifest refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuity, and simulated and maximum anterior keratometry (Kmax) using anterior segment OCT. RESULTS: Spherical and cylindrical refractive errors decreased from -2.38 ± 2.96 and -2.94 ± 2.16 to -1.81 ± 2.77 (P = .04) and -1.75 ± 2.07 (P = .01) diopters (D), respectively, 6 months postoperatively. There was an average gain of three lines of CDVA. Kmax decreased from 50.02 ± 1.99 to 47.89 ± 3.05 D (P= .03) and coma from 1.05 ± 0.21 to 0.21 ± 0.19 D (P = .01). CONCLUSIONS: Asymmetric femtosecond laser-cut allogenic segments allow a higher level of customization based on size, shape, and arc length, in contrast to the limited range of available synthetic asymmetrical segments. [J Refract Surg. 2023;39(12):856-862.].


Asunto(s)
Queratocono , Implantación de Prótesis , Humanos , Queratocono/cirugía , Coma/cirugía , Sustancia Propia/cirugía , Topografía de la Córnea , Refracción Ocular , Prótesis e Implantes , Rayos Láser , Estudios Retrospectivos
4.
Indian J Ophthalmol ; 71(12): 3723-3729, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37991313

RESUMEN

Corneal allogenic intrastromal ring segments (CAIRS) refer to the intracorneal placement of fresh, unprocessed, processed, preserved, or packaged allogenic rings/segments of any type/length. We described uniform-thickness CAIRS previously. We now describe a new technique of customized CAIRS to personalize the flattening effect as per individual topography. A prospective interventional case series of patients with pericentral/ paracentral decentered cones and gradation of keratometry with one side steeper than the other was conducted. Individually customized tapered CAIRS with variable volume, arc length, taper length, and gradient of taper were implanted. In total, 32 eyes of 29 patients with at least 1-year follow-up were included. Special double-bladed trephines and a CAIRS customizer template allowed the creation of individually customized CAIRS. Mean uncorrected distance visual acuity (UDVA) and spectacle-corrected distance visual acuity improved from 0.22 to 0.47 (P = 0.000) and from 0.76 to 0.89 (P = 0.001), respectively. Significant improvement was seen in K1, K2, Km, Kmax, topographic astigmatism, Q-value, sphere, cylinder, spherical equivalent, Root Mean Square (RMS), Higher Order Aberrations (HOA), and vertical coma (P < 0.01, 0.05). There was no significant change in the width or height of CAIRS between 1 month and last visit on anterior-segment optical coherence tomography. Five eyes continued to remain at the same UDVA, 27 eyes had at least 2 lines, and 13 eyes had at least 3 or more lines improvement in UDVA. The maximum improvement in UDVA was 7 lines. A significant difference in flattening was obtained at different zones across the tapered CAIRS. Thus, differential flattening was achieved across the cone based on the customization plan. Personalized customization was possible for each cornea, unlike limited models of progressive-thickness synthetic segments. Allogenic nature, greater customizability, efficacy, and absent need for large inventories are advantages compared to synthetic segments.


Asunto(s)
Queratocono , Humanos , Queratocono/diagnóstico , Queratocono/cirugía , Estudios Prospectivos , Implantación de Prótesis/métodos , Sustancia Propia/cirugía , Topografía de la Córnea , Refracción Ocular , Prótesis e Implantes
5.
J Refract Surg ; 39(11): 767-776, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37937759

RESUMEN

PURPOSE: To evaluate the visual, refractive, and tomographic results of patients with corneal ectasia treated with corneal allogenic intrastromal ring segments (CAIRS) insertion without concomitant corneal cross-linking. METHODS: Fifty-two eyes from 39 patients with stable corneal ectasia and unsatisfactory visual acuity with contact lenses were included. All patients underwent CAIRS insertion with no concomitant corneal procedure at the American University of Beirut Medical Center between September 2019 and July 2022. Visual, refractive, topographic, aberrometric, epithelial, stromal, and segment thickness data were measured relative to baseline at 1 week, 1 month, and at least 3 months postoperatively. Evaluations included slit-lamp examination, manifest refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuity, and tomography using anterior segment optical coherence tomography. RESULTS: Mean follow-up time was 6.9 ± 5.2 months. UDVA and CDVA improved from 0.97 ± 0.47 and 0.56 ± 0.19 preoperatively to 0.52 ± 0.21 (P < .001) and 0.23 ± 0.19 (P < .001) 3 months postoperatively. Manifest refraction spherical equivalent and cylinder improved from -6.71 ± 6.51 and -4.02 ± 2.24 diopters (D) preoperatively to -3.78 ± 4.07 D (P < .001) and -2.35 ± 1.98 D (P < .001) 3 months postoperatively, respectively. Maximum anterior keratometry and vertical coma decreased from 58.09 ± 7.92 D and 1.56 ± 1.09 µm to 52.48 ± 6.69 D (P < .001) and 0.43 ± 0.77 µm, respectively (P < .001). Corneal epithelium thickened proximal to the allogenic segment by 7.25 µm (P < .001), whereas stromal elevation at the cone decreased from 38.61 ± 18.5 to 23.82 ± 13.4 µm, respectively (P < .001). No major complications were observed and only 1 eye lost one line of CDVA. CONCLUSIONS: Treatment of corneal ectasia with CAIRS improved visual, refractive, topographic, and tomographic parameters. Epithelial thickening central to CAIRS, along with anterior stromal flattening is postulated to contribute to tomographic flattening and regularization. [J Refract Surg. 2023;39(11):767-776.].


Asunto(s)
Queratocono , Humanos , Queratocono/cirugía , Dilatación Patológica/cirugía , Sustancia Propia/diagnóstico por imagen , Sustancia Propia/cirugía , Topografía de la Córnea , Implantación de Prótesis , Refracción Ocular , Tomografía de Coherencia Óptica , Prótesis e Implantes , Estudios Retrospectivos
6.
J Cataract Refract Surg ; 49(12): 1285-1289, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37982777

RESUMEN

A 24-year-old man was referred for postrefractive surgery evaluation. The patient had a history of uneventful laser in situ keratomileusis (LASIK) in both eyes 3 months previously. According to the surgeon who originally performed the surgery, on slitlamp examination, only microstriae in the left eye was detected on postoperative day 1 and a more conservative follow-up approach was adopted without further immediate intervention. The patient returned only 3 months after surgery, complaining of low vision in the left eye that, according to the patient, had been present since postoperative week 2. The patient was then referred for examination and surgical procedure with a diagnosis of significant postoperative striae. The slitlamp examination revealed a LASIK flap with striae, epithelial filling, and a wrinkled appearance (Figure 1JOURNAL/jcrs/04.03/02158034-202312000-00017/figure1/v/2023-11-20T151558Z/r/image-tiff). There were no signs of infection or inflammation. Originally, the LASIK flap was programmed to be 110 µm. Preoperative manifest refraction in the right eye was -5.25 (20/20) and in the left eye was -5.25 (20/20). Assuming it is a case of late-approach LASIK flap striae, how would you proceed? Would you try to hydrate and lift the flap and just reposition it? Would you avoid lifting and associate phototherapeutic keratectomy (PTK) with excimer laser on top of the flap? Would you consider topo-guided surgery with regularization of the visual axis or even amputation of the flap?


Asunto(s)
Queratomileusis por Láser In Situ , Queratectomía Fotorrefractiva , Masculino , Humanos , Adulto Joven , Adulto , Sustancia Propia/cirugía , Agudeza Visual , Queratectomía Fotorrefractiva/métodos , Láseres de Excímeros/uso terapéutico , Refracción Ocular
7.
Indian J Ophthalmol ; 71(9): 3242-3245, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37602615

RESUMEN

The comorbidity of keratoconus with Fuchs' endothelial dystrophy with cataract is a rare clinical combination. We present an amalgamation of surgical techniques to manage the above clinical conditions and its complications in single setting. The modified triple procedure, namely, the phacoemulsification, pinhole pupilloplasty, and pre-Descemet's endothelial keratoplasty (PDEK) in the order of description is followed in single sitting. Lens removal by phacoemulsification, correction of irregular astigmatism by pinhole pupilloplasty (pinhole optics), and exchanging the endothelial layer for PDEK forms the main segments of the triple procedure. This combination of techniques may decrease the risk of multiple surgeries and its related complications. Moreover, it will allow the patient for faster visual rehabilitation by improving the uncorrected visual acuity and visual quality.


Asunto(s)
Extracción de Catarata , Queratoplastia Endotelial de la Lámina Limitante Posterior , Distrofia Endotelial de Fuchs , Queratocono , Facoemulsificación , Humanos , Queratocono/complicaciones , Queratocono/diagnóstico , Queratocono/cirugía , Distrofia Endotelial de Fuchs/complicaciones , Distrofia Endotelial de Fuchs/diagnóstico , Distrofia Endotelial de Fuchs/cirugía
8.
Surv Ophthalmol ; 68(6): 1129-1152, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37392969

RESUMEN

Descemet membrane endothelial keratoplasty (DMEK) is a partial-thickness corneal transplantation procedure that involves selective transplantation of the Descemet membrane and endothelium. DMEK offers significant advantages over other keratoplasty techniques, such as faster visual rehabilitation, better final visual acuity due to minimal optical interface effects, lower risk of allograft rejection, and less long-term dependence on topical steroids. Despite all its advantages, DMEK has been found to be more challenging than other corneal transplantation techniques, and its steep learning curve appears to be an obstacle to its widespread use and adoption by corneal surgeons worldwide. DMEK surgical training laboratories (wet labs) provide a window of opportunity for surgeons to learn, prepare, manipulate, and deliver these grafts in a risk-free environment. Wet labs are a significant learning tool, especially for those institutions that have limited tissue availability in their local centers. We provide a step-by-step guide for preparing DMEK grafts using different techniques on human and nonhuman models with instructional videos. This article should eventually help the trainees and the educators understand the requirements for performing DMEK and conducting a DMEK wet lab and develop their skills and interests from a wide variety of available techniques.


Asunto(s)
Enfermedades de la Córnea , Queratoplastia Endotelial de la Lámina Limitante Posterior , Humanos , Lámina Limitante Posterior/cirugía , Laboratorios , Queratoplastia Endotelial de la Lámina Limitante Posterior/métodos , Córnea/cirugía , Endotelio Corneal/cirugía , Enfermedades de la Córnea/cirugía
9.
Cornea ; 42(11): 1461-1464, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37399565

RESUMEN

PURPOSE: The aim of this study was to describe a new technique to facilitate the insertion of corneal allogenic intrastromal ring segments. METHODS: A single-segment corneal allogenic intrastromal ring segment (CAIRS) was trephined from donor corneas and allowed to markedly dehydrate for 75 minutes before the start of the procedure with a room humidity of 35% to 45%. The duration of the insertion step and the intrastromal segment size at 1 week as measured by optical coherence tomography were compared with previously performed single-segment CAIRS procedures using the conventional technique. RESULTS: A total of 41 eyes of 36 patients underwent 1-segment CAIRS insertion of the same trephination size (750 µm). Fifteen eyes underwent the conventional insertion procedure, and 26 eyes had a dehydrated segment inserted. The time taken to insert the CAIRS analyzed by surgical video recording starting after the femtosecond tunnel creation and initiation of the insertion to the segment ironing step was 282 ± 103 and 97 ± 23 seconds for the conventional and the dehydrated segment technique, respectively ( P < 0.001). Anterior segment optical coherence tomography performed 1 week postoperatively revealed similar segment thickness and width of 471.3 ± 54.1 µm and 1285.1 ± 191.0 µm for the conventional allogenic segments and 483.4 ± 58.3 µm and 1227.2 ± 165.2 µm for the dehydrated segments ( P = 0.515 and 0.314, respectively). CONCLUSIONS: Markedly dehydrated corneal allogenic segments are easier and faster to insert than the nondehydrated ones while maintaining similar sizes intrastromally. This dehydration technique makes the procedure similar to the one with synthetic segments and hence reduces the learning curve.


Asunto(s)
Sustancia Propia , Queratocono , Humanos , Sustancia Propia/cirugía , Deshidratación/cirugía , Queratocono/diagnóstico , Queratocono/cirugía , Implantación de Prótesis/métodos , Córnea/cirugía , Prótesis e Implantes , Topografía de la Córnea , Refracción Ocular
10.
Cornea ; 42(2): 243-246, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36582036

RESUMEN

ABSTRACT: Floppy or irregular irides may be seen during endothelial keratoplasty in complex cases or in eyes with damaged irides and may cause uneven air fill, retro-pupillary air escape, anterior bowing of iris, forward movement of lens-iris diaphragm, shallowing of anterior chamber (AC), bellowing and floppiness of iris, uneven AC depth, difficulty in inserting and opening graft, iris trauma, intraoperative bleeding, and iridodialysis. We present a technique of iridodiathermy for tautening and flattening such irides. With continuous irrigation using AC maintainer, the bipolar endodiathermy probe tip is applied in localized spots to midperipheral iris in the affected area with power and duration adjusted to induce mild localized shrinkage and tightening of iris stroma. Such iris tautening decreases its floppiness and prevents anterior bowing, excessive mobility, irido-corneal touch, and peripheral anterior synechiae formation. It provides a stable AC with regular depth and improved, uniform, and nonmigratory air fill, thus decreasing intraoperative challenges.


Asunto(s)
Enfermedades de la Córnea , Trasplante de Córnea , Enfermedades del Iris , Humanos , Iris/cirugía , Trasplante de Córnea/métodos , Enfermedades del Iris/etiología , Enfermedades del Iris/cirugía , Enfermedades de la Córnea/cirugía , Cámara Anterior/cirugía
11.
Ophthalmic Genet ; 44(2): 147-151, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36341706

RESUMEN

BACKGROUND: Although 8q21.11 microdeletion syndrome (8q21.11 DS) has been reported in association with congenital corneal opacities, reports of the clinicopathological features and management are scarce. METHODS: We reviewed medical records including ophthalmic evaluations, imaging, operative reports, and pathology reports of two unrelated patients referred to the Ophthalmology Clinic of UPMC Children's Hospital of Pittsburgh with a cytogenetic diagnosis of 8q21.11 DS. RESULTS: Ophthalmological evaluation of both children revealed bilateral enlarged, staphylomatous, and cloudy corneas with neovascularization. These findings were consistent with the diagnosis of congenital corneal staphyloma (CCS). In one patient, anterior segment optical coherence tomography and high-frequency ultrasound revealed materials consistent with lens remnants embedded in the cornea; this was confirmed by histopathology. In the second patient, lens was found to be adherent to the cornea during surgery. One eye underwent enucleation for corneal perforation secondary to elevated intraocular pressure. In the other eyes, treatment consisted of penetrating keratoplasty combined with vitrectomy. Ahmed tube was subsequently placed to control intraocular pressure. CONCLUSION: 8q21.11 microdeletion syndrome can be associated with bilateral CCS, likely related to a combination of anterior segment developmental anomalies and elevated intraocular pressure. Tectonic penetrating keratoplasty is necessary to prevent corneal perforation, together with a strict control of the intraocular pressure.


Asunto(s)
Trastornos de los Cromosomas , Opacidad de la Córnea , Perforación Corneal , Anomalías del Ojo , Glaucoma , Niño , Humanos , Trastornos de los Cromosomas/patología , Córnea/patología , Opacidad de la Córnea/diagnóstico , Perforación Corneal/complicaciones , Perforación Corneal/patología , Perforación Corneal/cirugía , Anomalías del Ojo/diagnóstico , Glaucoma/patología , Queratoplastia Penetrante/métodos
12.
J Refract Surg ; 38(4): 256-263, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35412922

RESUMEN

PURPOSE: To evaluate management of keratoconic eyes with anterior stromal necrosis overlying the intracorneal ring segment (ICRS), by either ICRS explantation alone or exchange with corneal allogenic intrastromal ring segments (CAIRS). METHODS: Among 643 Intacs SK (Additional Technology, Inc) inserted at one institutional center, 16 eyes (15 patients) with overlying spontaneous anterior stromal necrosis were identified. Data included size of stromal defect and refractive and topographical findings before ICRS insertion, before anterior stromal necrosis, and 6 months after intervention. RESULTS: The 10-year incidence of anterior stromal necrosis after femtosecond laser-assisted ICRS insertion was 5.5%. Eight eyes underwent ICRS removal only and 8 eyes had ICRS exchanged with CAIRS. In the first group, CDVA worsened from 0.14 before melt to 0.28 logMAR after removal (P = .10), simulated keratometry (SimK) and maximum axial keratometry (Kmax) increased from 44.73 to 46.34 diopters (D) (P = .14) and from 49.23 to 52.26 D (P = .14), respectively, and coma worsened from 0.87 to 1.52 D (P = .02). In the CAIRS group, CDVA of 0.16 before melt improved to 0.11 logMAR postoperatively (P > .99), and topographic indices stabilized with SimK, Kmax, and coma mildly altering from 45.31 to 45.44 D (P > .99), from 49.25 to 49.64 D (P > .99) and from 0.87 to 0.81 D (P > .99), respectively. Whether the ICRS were explanted or exchanged, the visual and topographic mean values were better than those reported before ICRS implantation, whereas higher order aberrations in eyes without CAIRS regressed to levels before ICRS insertion. At the site of melt, thinnest residual stromal thickness averaged 327 µm with ICRS removal and 490 µm with CAIRS. Eyes with larger melt areas resulted in less optimal results with CAIRS implantation. CONCLUSIONS: Early experience in the management of anterior stromal necrosis by exchange of polymethylmethacrylate ICRS with CAIRS seems to avoid stromal thinning and confer better visual and topographic results, which were more pronounced with thicker segments. The benefit of CAIRS in large stromal melts needs to be investigated. [J Refract Surg. 2022;38(4):256-263.].


Asunto(s)
Queratocono , Polimetil Metacrilato , Coma/cirugía , Sustancia Propia/cirugía , Topografía de la Córnea , Humanos , Queratocono/cirugía , Necrosis/cirugía , Prótesis e Implantes , Implantación de Prótesis/efectos adversos , Refracción Ocular , Estudios Retrospectivos
13.
J Cataract Refract Surg ; 48(4): 508-512, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-35318296

RESUMEN

A 40-year-old woman was referred for the assessment of bilateral corneal opacities with gradual visual decline over the course of the past decade. Her past ocular history is significant for bilateral amblyopia and strabismus surgery in both eyes before age 5. The patient's parents were told by her childhood ophthalmologist that she had a hereditary disorder. Her systemic review was significant for anal fissure and human leukocyte antigen-B27 ankylosing spondylitis. Her past ocular record revealed corrected distance visual acuity (CDVA) of 20/80 in both eyes in 2018 with central corneal haze. On presentation, her uncorrected distance visual acuity was 20/150 in both eyes. Her CDVA was 20/100 in both eyes with manifest refraction of +0.50 -2.50 × 075 in the right eye and +5.00 -2.25 × 094 in the left eye. Corneal topography reflected keratometry of 35.75/38.97 × 171 in the right eye and 36.45/38.35 × 32 in the left eye. Central corneal thickness was 669 µm and 652 µm, respectively. External slitlamp examination revealed a central faint stromal opacity inferior to the visual axis in the right eye and a central faint stromal opacity in the left eye, and both were associated with steep posterior curvature of the cornea (Figure 1). Further findings included 0.5 corneal haze with mild guttata, normal irides, and clear lenses in both eyes. Intraocular pressure was 23 mm Hg and 26 mm Hg, respectively (Figure 2, Supplemental Figures 1 and 2, http://links.lww.com/JRS/A543). Gonioscopy was unremarkable. Dilated fundus examination revealed a 0.15 cup-to-disc ratio bilaterally, but otherwise no pertinent vitreoretinal pathologies were noted. What is the most likely diagnosis? What medical or surgical interventions would you recommend for this patient? What is the prognosis for this patient?


Asunto(s)
Córnea , Opacidad de la Córnea , Adulto , Niño , Preescolar , Topografía de la Córnea , Femenino , Humanos , Presión Intraocular , Iris , Refracción Ocular , Agudeza Visual
14.
Front Med (Lausanne) ; 9: 863131, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35308504
16.
J Cataract Refract Surg ; 47(11): e37-e39, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34675164

RESUMEN

Corneal allogenic intrastromal ring segments (CAIRS) are semicircular pieces of donor corneal stroma, which may be surgically implanted to flatten keratoconic corneas. These segments can be trimmed to different thicknesses; whereas thicker segments confer greater flattening, their bulk renders them more technically challenging to insert. Consequently, thinner segments are often preferred, especially for starting surgeons. Here, we describe a technique for transiently thinning CAIRS to facilitate easy insertion, thereby permitting the use of thicker segments to achieve the maximal flattening effect.


Asunto(s)
Deshidratación , Queratocono , Sustancia Propia/cirugía , Topografía de la Córnea , Humanos , Queratocono/cirugía , Prótesis e Implantes , Implantación de Prótesis
17.
J Refract Surg ; 37(9): 623-630, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34506244

RESUMEN

PURPOSE: To compare the clinical and tomographic properties of adult patients with keratoconus treated with accelerated corneal cross-linking (A-CXL) versus accelerated contact lens-assisted corneal cross-linking (A-CACXL). METHODS: Patients who underwent A-CXL and A-CACXL due to progressive keratoconus were enrolled from January 2015 to January 2018 in this retrospective case-control study. The treatment group (minimum corneal thickness of less than 400 µm after epithelium removal; 30 patients, 30 eyes) was treated with A-CACXL; the control group (minimum corneal thickness of 400 µm or greater, 32 patients, 32 eyes) was treated with A-CXL. Assessments occurred before treatment and 12 months postoperatively. Demographic, clinical, and tomographic data were obtained from outpatient clinic reports. RESULTS: Significant improvement in visual acuity was evident at 12-month follow-up for the control group in uncorrected distance visual acuity (0.62 ± 0.42 vs 0.43 ± 0.31 logMAR, P = .01) and the treatment group in corrected distance visual acuity (0.51 ± 0.30 vs 0.40 ± 0.49 logMAR, P = .03). Progression of keratoconus was halted at similar rates for both groups (76.7% treatment, 84.4% control, P = .21). Mean minimum corneal thickness showed minor but significant thinning at the 12-month follow-up visit compared to baseline (control group = 463 ± 31 vs 450 ± 35 µm, P > .01; treatment group = 398 ± 32 vs 388 ± 41 µm, P = .02). CONCLUSIONS: A-CACXL halted keratoconus progression in 76.7% of eyes and achieved regression in 33.3% of eyes, with rates comparable to A-CXL. Visual outcomes improved for both groups, with similar keratometry changes. A-CACXL is an effective and safe option for patients with keratoconus and thin corneas, with results similar to A-CXL treatment in patients with a minimum corneal thickness of 400 µm or greater. [J Refract Surg. 2021;37(9):623-630.].


Asunto(s)
Lentes de Contacto , Queratocono , Fotoquimioterapia , Adulto , Estudios de Casos y Controles , Colágeno/uso terapéutico , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Estudios de Seguimiento , Humanos , Queratocono/tratamiento farmacológico , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Retrospectivos , Riboflavina/uso terapéutico , Rayos Ultravioleta
19.
J Cataract Refract Surg ; 47(11): 1403-1410, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-33770171

RESUMEN

PURPOSE: To evaluate the changes in refractive outcomes and corneal aberrations in central and paracentral keratoconus after selective transepithelial topography-guided photorefractive keratectomy combined with accelerated corneal crosslinking (STARE-X). SETTINGS: Centro Polispecialistico Mediterraneo, Siena Crosslinking Center, and University of Messina, Italy. DESIGN: Prospective, interventional, multicentric study. METHODS: Patients were subdivided into 2 groups: Group 1 with cone located within the central 3 mm zone (50 eyes) and Group 2 (50 eyes) with cone located outside the central 3 mm zone. Follow-up was 2 years at least for all eyes. Outcome parameters included uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA). Corneal tomography and corneal wavefront aberrations were assessed and compared before and 2 years after the treatment. RESULTS: 100 eyes of 100 patients underwent STARE-X protocol. At 2 years, UDVA and CDVA improved, and sphere, cylinder, and Kmax reduced after treatment in both groups (P < .001, respectively). Moreover, a statistically significant reduction was observed of total higher-order aberrations root main square (RMS), coma RMS, and spherical aberration RMS in both groups (P < .001, respectively). However, CDVA improved more in Group 1 than in Group 2 (P < .02). CONCLUSIONS: The STARE-X protocol demonstrated effective results in halting keratoconus progression and improving corneal regularity with a safe and effective profile. STARE-X improved both visual acuity and corneal aberration at 2 years. Longer follow-up studies are warranted to observe further long-term CXL flattening effect on the cone.


Asunto(s)
Queratocono , Fotoquimioterapia , Córnea , Sustancia Propia , Topografía de la Córnea , Reactivos de Enlaces Cruzados/uso terapéutico , Humanos , Queratocono/tratamiento farmacológico , Queratocono/cirugía , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Prospectivos , Riboflavina/uso terapéutico
20.
Indian J Ophthalmol ; 68(12): 2773-2778, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33229652

RESUMEN

Contact lens-assisted corneal cross-linking (CACXL) was introduced by Jacob et al. in 2012 for treating thin keratoconic corneas using riboflavin soaked soft contact lens to artificially increase the functional corneal thickness. It is advantageous over other thin corneal cross-linking techniques as it works independent of swelling properties of the cornea, is an epi-off technique and does not require additional time, additional expensive equipments or special solutions. The only additional requirement as compared to all other techniques is a UV barrier-free soft contact lens (SoflensTM, B&L) which is easily available and inexpensive. Advantages include simplicity, easy adaptability, early visual rehabilitation, good visual outcomes, safety, and efficacy. Progression rates are acceptable and the need for re-treatment has been low. CACXL can help regularize corneal shape and may be used in isolation or synergistically with Intracorneal ring segments (ICRS) or Corneal allogenic intrastromal ring segments (CAIRS). It gives about 70% stiffening as compared to standard Dresden protocol CXL in less ideal porcine eye studies. Murine eye models that closely mimic thin corneas and show greater cross-linking effect as compared to porcine eyes may be a better model for evaluation of CACXL, however further studies are needed. Care should be taken in selecting the right kind of contact lens. Proper technique should be followed, especially by confirming thinnest functional pachymetry to be above 400 microns intra-operatively before application of UV-A. The sub-contact lens riboflavin film should be avoided as also an excessively thick supra-contact lens riboflavin film and too many re-applications.


Asunto(s)
Lentes de Contacto , Queratocono , Fotoquimioterapia , Animales , Colágeno/uso terapéutico , Córnea , Paquimetría Corneal , Sustancia Propia , Reactivos de Enlaces Cruzados/uso terapéutico , Queratocono/tratamiento farmacológico , Ratones , Fármacos Fotosensibilizantes/uso terapéutico , Riboflavina/uso terapéutico , Porcinos , Rayos Ultravioleta
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...