Acta Medica (Hradec Kralove) ; 51(3): 129-37, 2008.
Article En | MEDLINE | ID: mdl-19271679

Past studies of postural control during standing have employed wide range of procedures including the outcome measures use to quantify postural control, the duration of the sample collected, sampling frequency and methods for data processing. Due to these differences there remains little, if any, common grounds for comparisons between studies to establish a concrete understanding of the features and bouns which characterize normal healthy postural control. This article deals with terms such as reliability and repeatability of stabilometric measurements, stabilometric data quantification and analysis. To clear up those terms is suggested, by the author of this paper, very important. The stabilometric measurements remain, nevertheless, different when dealing with aging adults. Though, we notes some alterations of the aging systems, this article is not entirely dedicated to the seniors population. Measurements of COP and technical notes remain the main axis of present paper.


Postural Balance/physiology , Biomechanical Phenomena , Foot/physiology , Humans , Posture , Proprioception/physiology , Vestibule, Labyrinth/physiology , Visual Perception
2.
Acta Medica (Hradec Kralove) ; 50(2): 139-43, 2007.
Article En | MEDLINE | ID: mdl-18035753

Posture in a still stance has been quantified by changes in the center of pressure (COP), in both anterior-posterior (A/P) and medial-lateral (M/L) directions and measured on a single force platform (Bertec PRO VEC 5.0). The purpose of this study was to estimate the variance in error and the intrasession test-retest reliability, and to determine which measures shall be taken for further measurements, especially with adults age 65 and older. We used two types of approximation for the reliability coefficient. Firstly, we used the equation according to Blahus (2) and secondly we used the Pearson's correlation coefficient for test-retest measurements. The findings allow us to say, among other things, that the tests of quiet standing Double Narrow Stance Eyes Open (DNSEO) and Double Narrow Stance Eyes Closed (DNSEC) are parallel, in the sense of parallel testing.


Kinesiology, Applied/instrumentation , Postural Balance , Posture , Adult , Female , Humans
3.
Acta Medica (Hradec Kralove) ; 50(2): 139-143, 2007.
Article En | MEDLINE | ID: mdl-28949914

Posture in a still stance has been quantified by changes in the center of pressure (COP), in both anterior-posterior (A/P) and medial-lateral (M/L) directions and measured on a single force platform (Bertec PRO VEC 5.0). The purpose of this study was to estimate the variance in error and the intrasession test-retest reliability, and to determine which measures shall be taken for further measurements, especially with adults age 65 and older. We used two types of approximation for the reliability coefficient. Firstly, we used the equation according to Blahus (2) and secondly we used the Pearson's correlation coefficient for test-retest measurements. The findings allow us to say, among other things, that the tests of quiet standing Double Narrow Stance Eyes Open (DNSEO) and Double Narrow Stance Eyes Closed (DNSEC) are parallel, in the sense of parallel testing.

...