Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(13)2023 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-37447690

RESUMEN

The article concerns the mechatronic design and experimental investigations of the HUBO automated human body scanning system. Functional problems that should be solved by using the developed scanning system are defined. These include reducing the number of sensors used while eliminating the need to rotate a human and ensuring the automation of the scanning process. Research problems that should be the subject of experimental research are defined. The current state of the art in the field of systems and techniques for scanning the human figure is described. The functional and technical assumptions for the HUBO scanning system are formulated. The mechanical design of the scanner, the hardware and information system architectures as well as the user's mobile application are presented. The method of operation of the scanning system and its innovative features are discussed. It is demonstrated that the developed solution of the scanning system allows the identified problems to be overcome. The methodology of the experimental research of the scanning system based on the photogrammetry technique is described. The results of laboratory studies with the use of dummies and experimental research with human participation are presented. The scope of the research carried out allows answers to the identified research problems related to the scanning of the human figure using the photogrammetry technique to be obtained. As part of laboratory tests using a measuring dummy, a mean error of 0.65 mm and standard deviation of the mean of 0.65 mm were obtained for the best scanner configuration. Research with human participation was carried out for the scanner version, in which the scanning time was 30 s, with the possibility of its reduction to 15 s. The results of studies using realistic dummies and with human participation were compared using the root mean square error parameter (RMSE) provided by the AliceVision framework, which was available for all analyzed objects. As a result, it was observed that these results are comparable, i.e., the RMSE parameter is equal to about 1 px.


Asunto(s)
Cuerpo Humano , Aplicaciones Móviles , Humanos , Imagenología Tridimensional/métodos , Fotogrametría/métodos , Automatización
2.
Sensors (Basel) ; 22(23)2022 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-36501882

RESUMEN

This article concerns the research of the HUBO full-body scanner, which includes the analysis and selection of the scanner's geometrical parameters in order to obtain the highest possible accuracy of the reconstruction of a human figure. In the scanner version analyzed in this paper, smartphone cameras are used as sensors. In order to process the collected photos into a 3D model, the photogrammetry technique is applied. As part of the work, dependencies between the geometrical parameters of the scanner are derived, which allows to significantly reduce the number of degrees of freedom in the selection of its geometrical parameters. Based on these dependencies, a numerical analysis is carried out, as a result of which the initial values of the geometrical parameters are pre-selected and distribution of scanner cameras is visualized. As part of the experimental research, the influence of selected scanner parameters on the scanning accuracy is analyzed. For the experimental research, a specially prepared dummy was used instead of the participation of a real human, which allowed to ensure the constancy of the scanned object. The accuracy of the object reconstruction was assessed in relation to the reference 3D model obtained with a scanner of superior measurement uncertainty. On the basis of the conducted research, a method for the selection of the scanner's geometrical parameters was finally verified, leading to the arrangement of cameras around a human, which guarantees high accuracy of the reconstruction. Additionally, to quantify the results, the quality rates were used, taking into account not only the obtained measurement uncertainty of the scanner, but also the processing time and the resulting efficiency.


Asunto(s)
Cuerpo Humano , Imagenología Tridimensional , Humanos , Imagenología Tridimensional/métodos , Fotogrametría/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA