Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Tipo de estudio
Intervalo de año de publicación
1.
J Occup Health ; 65(1): e12413, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37347801

RESUMEN

OBJECTIVE: This study aimed to quantitatively confirm the effects of dental specialists' work and stretching on musculoskeletal pain. METHODS: The pain pressure threshold was divided into five parts (neck, shoulder, trunk, lower back, and hand/arm) of the upper body and measured at 15 muscle trigger points. The pain pressure threshold before and after work was measured, and 30 min of stretching and rest were stipulated as an intervention. RESULTS: The pain pressure thresholds reduced significantly in all muscles after work (P < .05). In the stretching group, the pain pressure thresholds increased significantly in all muscles (P < .05). In particular, the iliocostalis lumborum (lower back), rhomboid (trunk), transverse carpal ligament (hand/arm), levator scapulae-superior angle (neck), and upper trapezius (shoulder) muscles showed the greatest decrease in pain pressure threshold after work and the greatest increase after stretching. CONCLUSIONS: Stretching helps immediately relieve musculoskeletal pain in dental professionals and can prevent and manage work-related musculoskeletal disorders.


Asunto(s)
Dolor Musculoesquelético , Humanos , Dolor Musculoesquelético/prevención & control , Músculo Esquelético , Umbral del Dolor/fisiología , Dolor de Cuello , Odontólogos
2.
Polymers (Basel) ; 14(1)2021 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-35012059

RESUMEN

Changes in intraoral pH can cause changes in the chemical decomposition and surface properties of treated resin-based pits and fissure sealants (sealant). The purpose of this study is to evaluate the release of bisphenol A (BPA) from sealants under three different pH conditions over time. The test specimen was applied with 6 sealants 5 mg each on a glass plate (10 × 10 mm) and photopolymerized. The samples were immersed for 10 min, 1 h, and 24 h in solutions of pH 3.0, 6.5, and 10.0 at 37 °C. BPA release was measured using a gas chromatography-mass spectrometer. A statistical analysis was performed by two-way ANOVA and one-way ANOVA to verify the effect of pH conditions and time on BPA release. The BPA concentration in the pH 3.0 group was higher at all points than with pH 6.5 and pH 10.0 (p < 0.05), and gradually increased over time (p < 0.05). As a result, it was confirmed that low pH negatively influences BPA release. Therefore, frequent exposure to low pH due to the consumption of various beverages after sealant treatment can negatively affect the sealant's chemical stability in the oral cavity.

3.
Iran J Public Health ; 48(5): 980-982, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31523659
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...