Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 155
Filtrar
1.
Br J Dermatol ; 163(5): 999-1006, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20716224

RESUMEN

BACKGROUND: Long-term follow-up studies on the prognosis and consequences of occupational hand eczema (OHE) and the prognostic risk factors for persistent OHE are sparse. OBJECTIVES: To determine the medical and occupational outcome after a follow-up of 7-14 years in 605 patients diagnosed with OHE and to identify the prognostic risk factors for the continuation of hand eczema. METHODS: Patients examined at the Finnish Institute of Occupational Health in 1994-2001 completed a follow-up questionnaire 7-14 years after diagnosis. RESULTS: The hand eczema had healed (no eczema during the last year) in 40% of patients with OHE. The duration of hand eczema before diagnosis was strongly associated with the continuation of eczema. Age, sex and diagnosis (allergic or irritant contact dermatitis) were not associated with the prognosis, but skin atopy, and especially respiratory atopy, were correlated with the continuation of hand eczema. Contact allergies in general were not risk factors for persistent OHE, but the presence of a work-related chromate allergy was associated with poor healing. A total of 34% of patients had changed their occupation due to OHE, and their long-term prognosis was better than those who had not. The hand eczema of patients originally in food-related occupations continued on an unfavourable course. CONCLUSIONS: In the logistic model, risk factors for the continuation of OHE were a long duration of hand eczema before diagnosis, respiratory atopy, skin atopy, and continuation in the same occupation. Those who ended up changing occupation due to their OHE had a better medical and economic prognosis.


Asunto(s)
Dermatitis Profesional/epidemiología , Eccema/epidemiología , Dermatosis de la Mano/epidemiología , Adulto , Dermatitis Profesional/diagnóstico , Dermatitis Profesional/etiología , Eccema/diagnóstico , Eccema/etiología , Femenino , Finlandia/epidemiología , Estudios de Seguimiento , Dermatosis de la Mano/diagnóstico , Dermatosis de la Mano/etiología , Humanos , Masculino , Persona de Mediana Edad , Ocupaciones , Pronóstico , Factores de Riesgo , Ausencia por Enfermedad , Encuestas y Cuestionarios
2.
Contact Dermatitis ; 53(3): 136-45, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16128752

RESUMEN

Since January 2001, the European Surveillance System on Contact Allergies (ESSCA), supported by European Union funding (contract QLK4-CT-2001-00343), has started to collect patch-test data. This comprises a standardized clinical history and the patch-test results using the European standard series, from 17 centres in 9 European countries listed above. In 2002 and 2003, 10 511 patients' test results have been pooled and analysed. The anamnestic data partly reflect the subspecialties of some centres. The most common allergen was nickel sulfate (17.3%); however, large international variations were observed. The prevalence of contact allergy to Myroxylon pereirae resin (balsam of Peru) (5.8%) is coming close to the frequency found with the fragrance mix (6.4%). Regarding contact allergy to chromium compounds, different frequencies were noted in the 2 centres focused on occupational dermatitis (2.3% in the FIOH versus 7.4% in the Nofer Institute). These most likely reflect the beneficial effect of addition of ferrous sulfate in one, but not the other country. As differences may partly be due to different patch-test reading, standardization may need to be refined further. By providing post-marketing surveillance in the field of contact allergy, ESSCA will meet its objective of increased consumer safety across Europe.


Asunto(s)
Alérgenos , Dermatitis Alérgica por Contacto/diagnóstico , Cooperación Internacional , Pruebas del Parche/estadística & datos numéricos , Vigilancia de la Población , Adulto , Alérgenos/efectos adversos , Dermatitis Alérgica por Contacto/epidemiología , Europa (Continente)/epidemiología , Humanos , Masculino , Ocupaciones/estadística & datos numéricos , Pruebas del Parche/normas
3.
Contact Dermatitis ; 53(1): 40-5, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15982231

RESUMEN

Contact sensitivity to cosmetics is common, but the sensitizing chemicals vary between countries and study periods. The present survey aimed at revealing the recent trends in patch test sensitivity with cosmetic chemicals in Finland. We report a retrospective multicentre survey of patch test reactions focusing on cosmetic-related substances and comparing the test results in 1995-97 with those in 2000-02. The most striking increases in the frequency of the patch test sensitivity were found with balsam of Peru and propolis from 4.0% to 6.2% (P < 0.001) and from 0.5% to 1.4% (P < 0.001), respectively, whereas the most prominent decreases were found with methylchloro/methylisothiazolinone and chlorhexidine diglugonate from 2.4% to 1.3% (P < 0.001) and from 1.2% to 0.5% (P < 0.001), respectively. The level of patch test sensitivity to methyldibromo glutaronitrile increased, although not significantly, from 1.0% to 1.5%. An increasing tendency was also found with hair dye chemicals 4-aminophenol and toluene-2,5-diamine or toluene-2,5-diamine sulfate from 1.3% to 3.8% and from 1.4% to 5.2%, respectively, while such a tendency was not found among permanent wave chemicals. The sensitivity level of fragrance mix remained the same (6% - 7%). We conclude that surveys revealing the state of sensitivity to cosmetic chemicals should be performed periodically in different countries.


Asunto(s)
Alérgenos/efectos adversos , Cosméticos/efectos adversos , Dermatitis Alérgica por Contacto/diagnóstico , Pruebas del Parche/métodos , Desodorantes/efectos adversos , Dermatitis Alérgica por Contacto/etiología , Femenino , Finlandia , Preparaciones para el Cabello/efectos adversos , Educación en Salud/métodos , Humanos , Masculino , Pruebas del Parche/normas , Perfumes/efectos adversos , Extractos Vegetales/efectos adversos , Valor Predictivo de las Pruebas , Própolis/efectos adversos , Estudios Retrospectivos
4.
Contact Dermatitis ; 49(4): 194-6, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14996067

RESUMEN

Melamine-formaldehyde resin (MFR) is used as a textile finish, in tableware, in surface coatings, and in glues in the furniture and wood industry. MFR is considered to be an infrequent sensitizer. Contact allergy to MFR is often combined with formaldehyde allergy. Patients allergic to textile finish often react to MFR, although other finishes are nowadays more commonly used. Besides allergy to textile finish, allergic contact dermatitis from MFR has been described in workers in composite production and in an orthopaedic plaster technician. To our knowledge, there are no previous reports of contact allergy in the plywood industry from MFR. We describe 3 cases of occupational allergic contact dermatitis from MFR without contact allergy to formaldehyde, 1 in the plywood industry, 1 in the production of melamine-laminated chipboard and 1 in laboratory work.


Asunto(s)
Dermatitis Alérgica por Contacto/etiología , Dermatitis Profesional/etiología , Fijadores/efectos adversos , Formaldehído/efectos adversos , Resinas Sintéticas/efectos adversos , Triazinas/efectos adversos , Adulto , Femenino , Fijadores/química , Formaldehído/química , Humanos , Masculino , Madera
5.
Allergy ; 57(12): 1205-7, 2002 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-12464052

RESUMEN

BACKGROUND: Epoxy resin (ER) is a common cause of occupational allergic contact dermatitis (ACD), but contact urticaria from ER is very rare. METHODS AND RESULTS: A plastic-product worker first developed ACD from diglycidyl ether of bisphenol A (DGEBA) epoxy resin, and subsequent exposure resulted half a year later in contact urticaria: first with edema of the lips and eyelids, and later an urticarial reaction on the upper chest, with strong swelling of the eyelids and tightness of the throat. The diagnosis was based on a positive skin prick test to his "own" ER compound, a positive prick test reaction to DGEBA, and a positive skin provocation test with the ER compound and DGEBA. The contact urticaria test reaction was strongly aggravated when the allergen was wiped off with an alcohol solution, apparently because the solution enhanced the penetration of the allergen. CONCLUSIONS: Our case is of interest, first, because contact urticaria from ER is very rare, and second, because this is the second report in which a strongly intensified contact urticaria reaction was provoked by an alcohol solution. We suggest that if the contact urticaria provocation test with low-molecular-weight chemicals is negative, a contact urticaria provocation test with alcohol (CUPTA) should be performed.


Asunto(s)
Carcinógenos/efectos adversos , Dermatitis Alérgica por Contacto/etiología , Dermatitis Profesional/etiología , Compuestos Epoxi/efectos adversos , Resinas Epoxi/efectos adversos , Urticaria/inducido químicamente , Adulto , Compuestos de Bencidrilo , Erupciones por Medicamentos/etiología , Humanos , Masculino
6.
Allergy ; 57(10): 894-9, 2002 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-12269934

RESUMEN

BACKGROUND: At present the diagnosis of IgE-mediated hypersensitivity to phthalic anhydride (PA) is based on conjugates that are not characterized or standardized. The aim of this study was to develop optimized and molecularly characterized PA conjugates that can be used to improve the diagnosis of PA-allergy. METHODS: The PA conjugates were synthesized and the number of haptens bound on a carrier protein was estimated by matrix-assisted laser desorption/ionization time of light (MALDI-TOF) mass spectrometry. The ability of conjugates to bind IgE and IgG antibodies was measured by enzyme-linked immunosorbent assay (ELISA). Reactivity of the conjugates in vivo was evaluated by skin prick testing. RESULTS: The most active IgE-binding conjugates had a PA : HSA molar ratio of 80 : 1. In the optimal conjugates the average numbers of PA haptens per carrier molecule of human serum albumin (HSA) were 14-16. In ELISA, all 13 patients and none of the 20 controls had IgE antibodies to optimized PA conjugate. The sensitivity and specificity of the ELISA was comparable to commercial CAP RAST. PA conjugates elicited positive test results in skin prick testing showing that conjugates are immunologically active also in vivo. CONCLUSIONS: These results indicate that optimized and molecularly characterized PA-HSA conjugates can be used both in vitro and in vivo assays to improve the diagnosis of PA allergy.


Asunto(s)
Hipersensibilidad a las Drogas , Anhídridos Ftálicos/efectos adversos , Anhídridos Ftálicos/inmunología , Adulto , Unión Competitiva/inmunología , Proteínas Portadoras/análisis , Proteínas Portadoras/inmunología , Hipersensibilidad a las Drogas/diagnóstico , Hipersensibilidad a las Drogas/etiología , Hipersensibilidad a las Drogas/inmunología , Ensayo de Inmunoadsorción Enzimática , Femenino , Haptenos/clasificación , Haptenos/inmunología , Humanos , Hipersensibilidad Inmediata/inducido químicamente , Inmunoglobulina E/análisis , Inmunoglobulina E/inmunología , Inmunoglobulina G/análisis , Inmunoglobulina G/inmunología , Masculino , Persona de Mediana Edad , Anhídridos Ftálicos/análisis , Prueba de Radioalergoadsorción , Albúmina Sérica/clasificación , Albúmina Sérica/inmunología , Pruebas Cutáneas
9.
J Environ Monit ; 3(3): 302-5, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11432267

RESUMEN

The exposure of dental personnel to airborne methacrylates and natural rubber latex (NRL) allergens was studied during placing of composite resin restorations in six dental clinics in Finland. Both area and personal sampling were performed, and special attention was paid to measurement of short-term emissions from the patient's mouth. Methacrylates were collected onto thermal desorption tubes filled with Tenax TA and NRL allergens onto membrane filters. The methacrylate samples were thermally desorbed and analysed by gas chromatography with mass selective detection. The NRL allergen concentrations were determined by the allergen-specific IgE-ELISA-inhibition method. The median concentration of 2-hydroxyethylmethacrylate (2-HEMA) was 0.004 mg m-3 close to the dental nurse's work-desk and 0.003 mg m-3 in the breathing zone of the nurse with a maximum concentration of 0.033 mg m-3. Above the patient's mouth the concentration of 2-HEMA was about 0.01 mg m-3 during both working stages, i.e., during application of adhesive and composite resins and during finishing and polishing of the fillings. Maximum concentrations of 3-5 times higher than median concentrations were also measured. Triethyleneglycol dimethacrylate was released into the air mainly during the removal of old composite resin restorations (0.05 mg m-3) and only to a minor extent during finishing and polishing procedures. The median concentration of the NRL allergen was 0.12 au m-3 (au = arbitrary unit) with a maximum concentration of 1.1 au m-3. The results show that, except for short-term emissions from the patient's mouth, the exposure of dental personnel to methacrylates and NRL allergens is very low. Measures to reduce exposure are discussed, as the airborne concentrations of methacrylates should be kept as low as possible in order to reduce the risk of hypersensitivity.


Asunto(s)
Contaminación del Aire Interior/análisis , Alérgenos/análisis , Clínicas Odontológicas , Personal de Odontología , Látex/análisis , Exposición Profesional , Monitoreo del Ambiente , Humanos , Exposición por Inhalación , Metacrilatos , Medición de Riesgo , Lugar de Trabajo
11.
Am J Contact Dermat ; 12(2): 83-7, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11381343

RESUMEN

BACKGROUND: Dental products contain many allergens, and may cause problems both for patients undergoing dental treatment and for dental personnel because of occupational exposure. Individual patch test clinics may not study sufficient numbers of patients to collect reliable data on uncommon allergens. OBJECTIVE: To collect information on dental allergens based on a multicenter study. MATERIALS AND METHODS: The Finnish Contact Dermatitis Group tested more than 4,000 patients (for most allergens, 2,300 to 2,600 patients) with dental screening series. Conventional patch testing was performed. The total number and percentage of irritant (scored as irritant [IR] or doubtful [?]) and allergic (scored as +, ++, or +++) patch test reactions, respectively, were calculated, as well as the highest and lowest percentage of allergic patch test reactions recorded by the different patch test clinics. A reaction index (RI) was calculated, giving information on the irritancy of the patch test substances. RESULTS: The most frequent allergic patch test reactions were caused by nickel (14.6%), ammoniated mercury (13%), mercury (10.3%), gold (7.7%), benzoic acid (4.3%), palladium (4.2%) and cobalt (4.1%). 2-hydroxyethyl methacrylate (2.8%) provoked most of the reactions caused by (meth)acrylates. Menthol, peppermint oil, ammonium tetrachloroplatinate, and amalgam alloying metals provoked no (neither allergic nor irritant) patch test reactions. CONCLUSION: Patch testing with allergens in the dental screening series, including (meth)acrylates and mercury, needs to be performed to detect contact allergy to dental products.


Asunto(s)
Alérgenos/efectos adversos , Odontología , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Dermatitis Profesional/epidemiología , Dermatitis Profesional/etiología , Finlandia/epidemiología , Humanos , Pruebas del Parche/estadística & datos numéricos , Estudios Retrospectivos
12.
Eur J Dermatol ; 11(3): 240-3, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11358732

RESUMEN

Quaternary ammonium compounds are water-soluble antimicrobials which are widely used in disinfectants, sterilizers, skin cleansers and antiseptic creams. One quaternary ammonium compound, alkylammonium amidobenzoate (Osmaron B) has for decades been used in udder ointments. Here we present a ship technician with occupationally induced sensitization to alkylammonium amidobenzoate. The diagnosis was reached only when it emerged, after careful questioning, that the patient was exposed to a substance peculiar to his workplace but not to his occupation and was then patch tested for it. It turned out that an udder ointment had been used at the patient's workplace as a hand ointment. Patch testing was positive to the patient's hand ointment, and Osmaron B at 0.1-0.01% in petrolatum. Other sensitizing quaternary ammonium compounds, namely benzalkonium chloride, benzethonium chloride, benzoxonium chloride, N-benzyl-N,N-dihydroxyethyl-N-cocosalkyl-ammonium chloride, cetalkonium chloride, cetylpyridinium chloride, cetrimonium bromide, chloroallylhexaminium chloride, dequalinium chloride, domiphen bromide, methylbenzethonium chloride and 2,3-epoxypropyl trimethyl ammonium chloride are reviewed briefly. The importance of patch testing to all materials in use by the patient is emphasized. It is also important to select non-allergenic hand creams for use at work places.


Asunto(s)
Benzoatos/efectos adversos , Dermatitis Alérgica por Contacto/etiología , Dermatitis Profesional/etiología , Dermatosis de la Mano/inducido químicamente , Compuestos de Amonio Cuaternario/efectos adversos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Profesional/diagnóstico , Dermatosis de la Mano/diagnóstico , Desinfección de las Manos , Humanos , Masculino , Anamnesis , Persona de Mediana Edad , Pomadas , Navíos , Pruebas Cutáneas
13.
Contact Dermatitis ; 44(4): 247, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11336001

RESUMEN

The mechanism of occupational asthma from diisocyanates (DI)(1-10)(Fig. 1) is not fully known; only about 10%-30% of such patients have specific IgE antibodies to DI (3, 11, 12). A T-cell mediated response has been considered to be involved in DI asthma (13) and we therefore wondered whether patch testing might be of any help in its diagnosis.


Asunto(s)
Asma/inducido químicamente , Dermatitis Alérgica por Contacto/etiología , Isocianatos/efectos adversos , 2,4-Diisocianato de Tolueno/efectos adversos , Adulto , Alérgenos/efectos adversos , Dermatitis Profesional/etiología , Femenino , Dermatosis de la Mano/inducido químicamente , Humanos , Masculino , Persona de Mediana Edad , Pintura/efectos adversos , Pruebas del Parche
15.
Contact Dermatitis ; 44(4): 213-7, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11260236

RESUMEN

Exposure to wood dusts may cause various skin and mucosal symptoms. Allergic dermatoses, caused by wood dusts, diagnosed at the Finnish Institute of Occupational Health during 1976-1999 are reported here. 16 had allergic contact dermatitis and, 2 had contact urticaria. 9 men (3 cabinet makers, 3 joiners, 1 carpenter, 1 knifemaker and 1 machinist) were mainly exposed to tropical hardwoods. 1 man had dermatitis caused by western red cedar. 5 patients, 3 men and 2 women, were exposed to Finnish pine or spruce dusts, and 1 man to aspen. 7 also had rhinitis, 4 asthma or dyspnoea and 3 conjunctivitis. On patch testing, 10 men reacted to 9 different wood dusts, including teak (5), palisander (3), jacaranda (2), mahogany (2), walnut (2) and obeche (1). Reactions to wood allergens, including lapachol (2), deoxylapachol (1), (R)-3,4-dimethoxydahlbergione (2), 2,6-dimethoxy-1,4-benzoquinone (1), mansonone A (2) and salicyl alcohol (1), were noted in 4 cases. All but 1 of 5 patients exposed to pine or spruce dusts reacted to the sawdusts, all 5 to colophonium, 3 to abietic acid, 2 to tall oil resin, 3 to wood tar mix and 4 to other wood gum resins. Of the 2 CU patients, 1 was prick and RAST positive to obeche, 1 reacted with urticarial dermatitis to punah wood dust on chamber exposure. Occupational allergic dermatoses are mainly caused by the dusts of hardwoods, mostly due to Type IV allergy, but may also be caused by softwood dusts. Patch tests can be done with wood dusts, but should be confirmed by patch testing with wood allergens if possible.


Asunto(s)
Dermatitis Alérgica por Contacto/etiología , Dermatitis Profesional/etiología , Polvo/efectos adversos , Aceites de Plantas , Madera , Adulto , Contaminantes Ocupacionales del Aire/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Exposición Profesional/efectos adversos , Pruebas del Parche
16.
Am J Contact Dermat ; 12(1): 18-24, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11244135

RESUMEN

BACKGROUND: Compositae mix and sesquiterpene-lactone (SL) mix are important patch test substances to show allergic contact dermatitis from various Compositae plants. OBJECTIVES: The aims of this study are to calculate the sensitization rates to Compositae mix and SL mix in an occupational dermatology clinic and to describe cases of active sensitization caused by patch testing with Compositae mix and SL mix. METHODS: Conventional patch testing was performed. SL mix (0.1%) and Compositae mix (6% in petrolatum) were tested in a modified European standard series and a plant allergen series. Testing with other appropriate patch test series was also performed. RESULTS: SL mix provoked 8 allergic patch test reactions (0.7%) in 1,076 patients, whereas Compositae mix was positive in 15 of 346 patients (4.2%). Three patients were actively sensitized to Compositae mix and 1 patient to SL mix. One patient was also sensitized to other plant allergens in a series of allergenic plant chemicals, namely to Mansonone A, an ortho-quinone; (R)-3,4-dimethoxydalbergione, a quinone; and Chlorophorin, a hydroxy stilbene. Allergic patch test reactions to laurel leaf were caused by cross-sensitization to SLs. CONCLUSION: Compositae mix seems to be a more important patch test substance than SL mix to detect allergic contact dermatitis to Compositae plants, but patch testing may sensitize. The concentration of the individual components of the Compositae mix should be adjusted so that the mix detects allergic patients but does not sensitize.


Asunto(s)
Alérgenos , Asteraceae/efectos adversos , Dermatitis Alérgica por Contacto/diagnóstico , Pruebas del Parche/normas , Sesquiterpenos , Estilbenos , Adulto , Alérgenos/efectos adversos , Benzoquinonas/efectos adversos , Dermatitis Alérgica por Contacto/etiología , Femenino , Humanos , Lactonas/administración & dosificación , Masculino , Naftoquinonas/efectos adversos , Extractos Vegetales/efectos adversos , Valor Predictivo de las Pruebas , Resorcinoles/efectos adversos , Sesquiterpenos/administración & dosificación , Sesquiterpenos/efectos adversos , Sesquiterpenos de Eudesmano
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...