Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Neurosci ; 17: 1189615, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37397462

RESUMEN

Traumatic brain injury (TBI) is caused by a wide range of physical events and can induce an even larger spectrum of short- to long-term pathophysiologies. Neuroscientists have relied on animal models to understand the relationship between mechanical damages and functional alterations of neural cells. These in vivo and animal-based in vitro models represent important approaches to mimic traumas on whole brains or organized brain structures but are not fully representative of pathologies occurring after traumas on human brain parenchyma. To overcome these limitations and to establish a more accurate and comprehensive model of human TBI, we engineered an in vitro platform to induce injuries via the controlled projection of a small drop of liquid onto a 3D neural tissue engineered from human iPS cells. With this platform, biological mechanisms involved in neural cellular injury are recorded through electrophysiology measurements, quantification of biomarkers released, and two imaging methods [confocal laser scanning microscope (CLSM) and optical projection tomography (OPT)]. The results showed drastic changes in tissue electrophysiological activities and significant releases of glial and neuronal biomarkers. Tissue imaging allowed us to reconstruct the injured area spatially in 3D after staining it with specific nuclear dyes and to determine TBI resulting in cell death. In future experiments, we seek to monitor the effects of TBI-induced injuries over a prolonged time and at a higher temporal resolution to better understand the subtleties of the biomarker release kinetics and the cell recovery phases.

2.
Sens Diagn ; 2(4): 964-975, 2023 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-37465008

RESUMEN

Traumatic brain injuries (TBI) are typically acquired when a sudden violent event causes damage to the brain tissue. A high percentage (70-85%) of all TBI patients are suffering from mild TBI (mTBI), which is often difficult to detect and diagnose with standard imaging tools (MRI, CT scan) due to the absence of significant lesions and specific symptoms. Recent studies suggest that a screening test based on the measurement of a protein biomarker panel directly from a patient's blood can facilitate mTBI diagnosis. Herein, we report a novel prototype system designed as a precursor of a future hand-held point-of-care (POC) diagnostic device for the simultaneous multi-biomarker sensing, employing a microarray-type spatially resolved electrochemiluminescence immunoassay (SR-ECLIA). The small tabletop prototype consists of a screen-printed electrode compartment to conduct multi-analyte ECL sandwich assays, a potentiostat module and a light collection module, all integrated into a compact 3D-printed housing (18.2 × 16.5 × 5.0 cm), as well as an sCMOS detector. Based on this design concept, further miniaturization, system integration, performance optimization and clinical evaluation shall pave the way towards the development of a portable instrument for use at the site of accident and healthcare. To demonstrate the system's feasibility, current performance and efficiency, the simultaneous detection of three mTBI biomarkers (GFAP, h-FABP, S100ß) in 50% serum was achieved in the upper pg mL-1 range. The proposed device is amenable to the detection of other biomarker panels and thus could open new medical diagnostic avenues for sensitive multi-analyte measurements with low-volume biological sample requirements.

3.
Methods Mol Biol ; 2578: 41-52, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36152279

RESUMEN

Immobilization of peptides to a solid surface is frequently an important first step before they can be probed with a variety of biological samples in a heterogeneous assay format for research and clinical diagnostic purposes. Peptides can be derivatized in many ways to subsequently covalently attach them to an activated solid surface such as, for instance, epoxy-functionalized glass slides. Here, we describe a clean, efficient, and reproducible fabrication process based on catalyst-free click chemistry compatible with the construction of low- to high-density peptide microarrays.


Asunto(s)
Química Clic , Péptidos , Alquinos , Azidas , Catálisis , Análisis por Micromatrices
4.
Biosensors (Basel) ; 12(3)2022 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-35323442

RESUMEN

Globally, 70 million people are annually affected by TBI. A significant proportion of all TBI cases are actually mild TBI (concussion, 70-85%), which is considerably more difficult to diagnose due to the absence of apparent symptoms. Current clinical practice of diagnosing mTBI largely resides on the patients' history, clinical aspects, and CT and MRI neuroimaging observations. The latter methods are costly, time-consuming, and not amenable for decentralized or accident site measurements. As an alternative (and/or complementary), mTBI diagnostics can be performed by detection of mTBI biomarkers from patients' blood. Herein, we proposed two strategies for the detection of three mTBI-relevant biomarkers (GFAP, h-FABP, and S100ß), in standard solutions and in human serum samples by using an electrochemiluminescence (ECL) immunoassay on (i) a commercial ECL platform in 96-well plate format, and (ii) a "POC-friendly" platform with disposable screen-printed carbon electrodes (SPCE) and a portable ECL reader. We further demonstrated a proof-of-concept for integrating three individually developed mTBI assays ("singleplex") into a three-plex ("multiplex") assay on a single SPCE using a spatially resolved ECL approach. The presented methodology demonstrates feasibility and a first step towards the development of a rapid POC multiplex diagnostic system for the detection of a mTBI biomarker panel on a single SPCE.


Asunto(s)
Conmoción Encefálica , Biomarcadores , Conmoción Encefálica/diagnóstico , Humanos , Inmunoensayo , Mediciones Luminiscentes/métodos , Sistemas de Atención de Punto
5.
RSC Adv ; 11(28): 17301-17319, 2021 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-34094508

RESUMEN

Traumatic Brain Injury (TBI) being one of the principal causes of death and acquired disability in the world imposes a large burden on the global economy. Mild TBI (mTBI) is particularly challenging to assess due to the frequent lack of well-pronounced post-injury symptoms. However, if left untreated mTBI (especially when repetitive) can lead to serious long-term implications such as cognitive and neuropathological disorders. Computer tomography and magnetic resonance imaging commonly used for TBI diagnostics require well-trained personnel, are costly, difficult to adapt for on-site measurements and are not always reliable in identifying small brain lesions. Thus, there is an increasing demand for sensitive point-of-care (POC) testing tools in order to aid mTBI diagnostics and prediction of long-term effects. Biomarker quantification in body fluids is a promising basis for POC measurements, even though establishing a clinically relevant mTBI biomarker panel remains a challenge. Actually, a minimally invasive, rapid and reliable multianalyte detection device would allow the efficient determination of injury biomarker release kinetics and thus support the preclinical evaluation and clinical validation of a proposed biomarker panel for future decentralized in vitro diagnostics. In this respect electrochemical biosensors have recently attracted great attention and the present article provides a critical study on the electrochemical protocols suggested in the literature for detection of mTBI-relevant protein biomarkers. The authors give an overview of the analytical approaches for transduction element functionalization, review recent technological advances and highlight the key challenges remaining in view of an eventual integration of the proposed concepts into POC diagnostic solutions.

6.
JACS Au ; 1(5): 598-611, 2021 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-34056635

RESUMEN

Skin problems are often overlooked due to a lack of robust and patient-friendly monitoring tools. Herein, we report a rapid, noninvasive, and high-throughput analytical chemical methodology, aiming at real-time monitoring of skin conditions and early detection of skin disorders. Within this methodology, adhesive sampling and laser desorption ionization mass spectrometry are coordinated to record skin surface molecular mass in minutes. Automated result interpretation is achieved by data learning, using similarity scoring and machine learning algorithms. Feasibility of the methodology has been demonstrated after testing a total of 117 healthy, benign-disordered, or malignant-disordered skins. Remarkably, skin malignancy, using melanoma as a proof of concept, was detected with 100% accuracy already at early stages when the lesions were submillimeter-sized, far beyond the detection limit of most existing noninvasive diagnosis tools. Moreover, the malignancy development over time has also been monitored successfully, showing the potential to predict skin disorder progression. Capable of detecting skin alterations at the molecular level in a nonsurgical and time-saving manner, this analytical chemistry platform is promising to build personalized skin care.

7.
Mikrochim Acta ; 188(2): 36, 2021 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-33420843

RESUMEN

An amperometric sensor based on an inkjet-printed graphene electrode (IPGE) modified with amine-functionalized montmorillonite (Mt-NH2) for the electroanalysis and quantification of gentisic acid (GA) has been developed. The organoclay used as IPGE modifier was prepared and characterized by infrared spectroscopy, X-ray diffraction, scanning electron microscopy, CHN elemental analysis, and thermogravimetry. The electrochemical features of the Mt-NH2/IPGE sensor were investigated by cyclic voltammetry and electrochemical impedance spectroscopy. The sensor exhibited charge selectivity ability which was exploited for the electrochemical oxidation of GA. The GA amperometric response was high in acidic medium (Brinton-Robinson buffer, pH 2) due to favorable interactions between the protonated amine groups and the negatively charged GA. Kinetic studies were also performed by cyclic voltammetry, and the obtained electron transfer rate constant of 11.3 s-1 indicated a fast direct electron transfer rate of GA to the electrode. An approach using differential pulse voltammetry was then developed for the determination of GA (at + 0.233 V vs. a pseudo Ag/Ag+ reference electrode), and under optimized conditions, the sensor showed high sensitivity, a wide working linear range from 1 to 21 µM (R2 = 0.999), and a low detection limit of 0.33 µM (0.051 ± 0.01 mg L-1). The proposed sensor was applied to quantify GA in a commercial red wine sample. The simple and rapid method developed using a cheap clay material could be employed for the determination of various phenolic acids.


Asunto(s)
Bentonita/química , Gentisatos/análisis , Grafito/química , Técnicas Electroquímicas/métodos , Electrodos , Gentisatos/química , Límite de Detección , Oxidación-Reducción , Impresión , Vino/análisis
8.
Mikrochim Acta ; 186(8): 532, 2019 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-31309336

RESUMEN

An electrochemical sensor is described for the determination of L-dopa (levodopa; 3,4-dihydroxyphenylalanine). An inkjet-printed carbon nanotube (IJPCNT) electrode was modified with manganese dioxide microspheres by drop-casting. They coating was characterized by field emission scanning electron microscopy, Fourier-transform infrared spectroscopy and X-ray powder diffraction. The sensor, best operated at a working voltage of 0.3 V, has a linear response in the 0.1 to 10 µM L-dopa concentration range, a 54 nM detection limit, excellent reproducibility, repeatability and selectivity. The amperometric approach was applied to the determination of L-dopa in spiked biological fluids and displayed satisfactory accuracy and precision. Graphical abstract Schematic representation of an amperometric method for determination L-dopa. It is based on the use of inkjet-printed carbon nanotube electrode (IJPCNT) modified with manganese dioxide (MnO2).


Asunto(s)
Técnicas Electroquímicas/métodos , Levodopa/análisis , Microesferas , Nanotubos de Carbono/química , Electrodos , Humanos , Tinta , Levodopa/sangre , Levodopa/orina , Límite de Detección , Compuestos de Manganeso/química , Óxidos/química , Sistemas de Atención de Punto , Reproducibilidad de los Resultados
9.
Anal Chem ; 91(14): 8835-8844, 2019 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-31198034

RESUMEN

Polyacrylamide-coated, carbon nanotube (PA/CNT) electrodes were prepared by an inkjet printing process and used to measure pyocyanin and uric acid in a wound fluid simulant at 37 °C. These two molecules are potential indicators of infection, and therefore their detection could prove useful for monitoring wound healing. Pyocyanin is a marker for the common wound bacterium Pseudomonas aeruginosa. Our long-term goal is to use these inexpensive and disposable electrodes to measure biomarkers of wound healing directly. In this proof-of-concept work, studies were performed in a wound fluid simulant to evaluate the stability of the electrodes and their responsiveness for the two bioanalytes. The PA/CNT inkjet-printed electrodes and electrical contacts were stable with unchanging physical and electrochemical properties in the wound fluid simulant over a 7-8-day period at 37 °C. The detection figures of merit for pyocyanin in the simulant at 37 °C were as follows: linear over the physiologically relevant range = 0.10 to 100 µmol L-1 (R2 = 0.9992), limit of detection = 0.10 µmol L-1 (S/N = 3), sensitivity = 35.6 ± 0.8 mA-L mol-1 and response variability ≤4% RSD. The detection figures of merit for uric acid in the simulant at 37 °C were as follows: linear over the physiologically relevant range = 100 to 1000 µmol L-1 (R2 = 0.9997), sensitivity = 2.83 ± 0.01 mA-L mol-1, and response variability ≤4% RSD. The limit of detection was not determined. The PA/CNT electrodes were also used to quantify pyocyanin concentrations in cell-free culture media from different strains of P. aeruginosa. The detected concentrations ranged from 1.00 ± 0.02 to 118 ± 6 µM depending on the strain.


Asunto(s)
Medios de Cultivo/análisis , Nanotubos de Carbono/química , Piocianina/análisis , Ácido Úrico/análisis , Heridas y Lesiones/patología , Técnicas Biosensibles/instrumentación , Electrodos , Diseño de Equipo , Pseudomonas aeruginosa/aislamiento & purificación , Heridas y Lesiones/microbiología
10.
J Am Chem Soc ; 140(44): 14753-14760, 2018 11 07.
Artículo en Inglés | MEDLINE | ID: mdl-30336008

RESUMEN

Herein is reported a surface-confined microscopy based on electrochemiluminescence (ECL) that allows to image the plasma membrane of single cells at the interface with an electrode. By analyzing photoluminescence (PL), ECL and AFM images of mammalian CHO cells, we demonstrate that, in contrast to the wide-field fluorescence, ECL emission is confined to the immediate vicinity of the electrode surface and only the basal membrane of the cell becomes luminescent. The resulting ECL microscopy reveals details that are not resolved by classic fluorescence microscopy, without any light irradiation and specific setup. The thickness of the ECL-emitting regions is ∼500 nm due to the unique ECL mechanism that involves short-lifetime electrogenerated radicals. In addition, the reported ECL microscopy is a dynamic technique that reflects the transport properties through the cell membranes and not only the specific labeling of the membranes. Finally, disposable transparent carbon nanotube (CNT)-based electrodes inkjet-printed on classic microscope glass coverslips were used to image cells in both reflection and transmission configurations. Therefore, our approach opens new avenues for ECL as a surface-confined microscopy to develop single cell assays and to image the dynamics of biological entities in cells or in membranes.


Asunto(s)
Membrana Celular/química , Técnicas Electroquímicas , Mediciones Luminiscentes , Animales , Células CHO , Células Cultivadas , Cricetulus , Fluorescencia , Propiedades de Superficie
11.
Angew Chem Int Ed Engl ; 57(45): 14942-14946, 2018 11 05.
Artículo en Inglés | MEDLINE | ID: mdl-30187617

RESUMEN

A combination of an immuno-affinity enrichment strategy and sensitive amperometric read-out was implemented in a point-of-care platform intended for bacterial infection analysis. Bacterial cells, selectively captured and enriched from complex matrices through immuno-affinity, were detected by amperometric monitoring of the redox state of metabolic activity indicators, providing species identification and viable-cell quantification. The method was successfully employed for the diagnosis of bacterial infections including antimicrobial susceptibility testing with only several hours of total working time.


Asunto(s)
Anticuerpos Inmovilizados/química , Bacterias/aislamiento & purificación , Infecciones Bacterianas/diagnóstico , Técnicas Biosensibles/instrumentación , Técnicas Electroquímicas/instrumentación , Separación Inmunomagnética/instrumentación , Sistemas de Atención de Punto , Diseño de Equipo , Humanos , Dispositivos Laboratorio en un Chip
12.
Chem Sci ; 9(8): 2212-2221, 2018 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-29719694

RESUMEN

Titanium dioxide-modified target plates were developed to enhance intact bacteria analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. The plates were designed to photocatalytically destroy the bacterial envelope structure and improve the ionization efficiency of intracellular components, thereby promoting the measurable mass range and the achievable detection sensitivity. Accordingly, a method for rapid detection of antimicrobial resistance-associated proteins, conferring bacterial resistance against antimicrobial drugs, was established by mass spectrometric fingerprinting of intact bacteria without the need for any sample pre-treatment. With this method, the variations in resistance proteins' expression levels within bacteria were quickly measured from the relative peak intensities. This approach of resistance protein detection directly from intact bacteria by mass spectrometry is useful for fast discrimination of antimicrobial-resistant bacteria from their non-resistant counterparts whilst performing species identification. Also, it could be used as a rapid and convenient way for initial determination of the underlying resistance mechanisms.

13.
J Am Chem Soc ; 139(46): 16830-16837, 2017 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-29064235

RESUMEN

We report here the development of coreactant-based electrogenerated chemiluminescence (ECL) as a surface-confined microscopy to image single cells and their membrane proteins. Labeling the entire cell membrane allows one to demonstrate that, by contrast with fluorescence, ECL emission is only detected from fluorophores located in the immediate vicinity of the electrode surface (i.e., 1-2 µm). Then, to present the potential diagnostic applications of our approach, we selected carbon nanotubes (CNT)-based inkjet-printed disposable electrodes for the direct ECL imaging of a labeled plasma receptor overexpressed on tumor cells. The ECL fluorophore was linked to an antibody and enabled to localize the ECL generation on the cancer cell membrane in close proximity to the electrode surface. Such a result is intrinsically associated with the unique ECL mechanism and is rationalized by considering the limited lifetimes of the electrogenerated coreactant radicals. The electrochemical stimulus used for luminescence generation does not suffer from background signals, such as the typical autofluorescence of biological samples. The presented surface-confined ECL microscopy should find promising applications in ultrasensitive single cell imaging assays.

14.
J Environ Manage ; 195(Pt 2): 174-185, 2017 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-27416798

RESUMEN

In this work, an Iodinated Contrast Medium (ICM), Iohexol, was subjected to treatment by 3 Advanced Oxidation Processes (AOPs) (UV, UV/H2O2, UV/H2O2/Fe2+). Water, wastewater and urine were spiked with Iohexol, in order to investigate the treatment efficiency of AOPs. A tri-level approach has been deployed to assess the UV-based AOPs efficacy. The treatment was heavily influenced by the UV transmittance and the organics content of the matrix, as dilution and acidification improved the degradation but iron/H2O2 increase only moderately. Furthermore, optimization of the treatment conditions, as well as modeling of the degradation was performed, by step-wise constructed quadratic or product models, and determination of the optimal operational regions was achieved through desirability functions. Finally, global chemical parameters (COD, TOC and UV-Vis absorbance) were followed in parallel with specific analyses to elucidate the degradation process of Iohexol by UV-based AOPs. Through HPLC/MS analysis the degradation pathway and the effects the operational parameters were monitored, thus attributing the pathways the respective modifications. The addition of iron in the UV/H2O2 process inflicted additional pathways beneficial for both Iohexol and organics removal from the matrix.


Asunto(s)
Yohexol , Aguas Residuales/química , Peróxido de Hidrógeno/química , Oxidación-Reducción , Rayos Ultravioleta , Contaminantes Químicos del Agua/química , Purificación del Agua
15.
Environ Sci Pollut Res Int ; 23(1): 469-76, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26310708

RESUMEN

Composite material Zr-doped TiO2, suitable for the removal of arsenic from water, was synthetized with fast and simple microwave-hydrothermal method. Obtained material, Zr-TiO2, had uniform size and composition with zirconium ions incorporated into crystal structure of titanium dioxide. Synthetized composite material had large specific surface area and well-developed micropore and mesopore structure that was responsible for fast adsorption of As(III) and As(V) from water. The influence of pH on the adsorption capacity of arsenic was studied. The kinetics and isotherm experiments were also performed. The treatment of natural water sample containing high concentration of arsenic with composite material Zr-TiO2 was efficient. The concentration of arsenic was reduced to the value recommended by WHO.


Asunto(s)
Arsénico/química , Nanocompuestos/química , Polímeros/química , Contaminantes Químicos del Agua/química , Purificación del Agua/instrumentación , Adsorción , Concentración de Iones de Hidrógeno , Cinética , Microondas , Polímeros/síntesis química , Titanio/química , Circonio/química
16.
Fed Pract ; 32(6): 20-23, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30766068

RESUMEN

There was no statistically significant difference between amoxicillin and nitrofurantoin for the treatment of ampicillin-resistant Enterococcus faecium urinary tract infections.

17.
Sci Total Environ ; 505: 1148-55, 2015 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-25466684

RESUMEN

Pharmaceutical compounds have been detected frequently in surface and ground water. Advanced Oxidation Processes (AOPs) were reported as very efficient for removal of various organic compounds. Nevertheless, due to incomplete degradation, toxic intermediates can induce more severe effects than the parent compound. Therefore, toxicity studies are necessary for the evaluation of possible uses of AOPs. In this study the effectiveness and capacity for environmental application of three different AOPs were estimated. They were applied and evaluated for removal of ibuprofen from water solutions. Therefore, two treatments were performed in a non-thermal plasma reactor with dielectric barrier discharge with and without a homogenous catalyst (Fe(2+)). The third treatment was the Fenton reaction. The degradation rate of ibuprofen was measured by HPLC-DAD and the main degradation products were identified using LC-MS TOF. Twelve degradation products were identified, and there were differences according to the various treatments applied. Toxicity effects were determined with two bioassays: Vibrio fischeri and Artemia salina. The efficiency of AOPs was demonstrated for all treatments, where after 15 min degradation percentage was over 80% accompanied by opening of the aromatic ring. In the treatment with homogenous catalyst degradation reached 99%. V. fischeri toxicity test has shown greater sensitivity to ibuprofen solution after the Fenton treatment in comparison to A. salina.


Asunto(s)
Peróxido de Hidrógeno/química , Ibuprofeno/química , Hierro/química , Modelos Químicos , Gases em Plasma
18.
J Hazard Mater ; 260: 1092-9, 2013 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-23892174

RESUMEN

Degradation of two triketone herbicides, mesotrione and sulcotrione, was studied using four different advanced oxidation processes (AOPs): ozonization, dielectric barrier discharge (DBD reactor), photocatalysis and Fenton reagent, in order to find differences in mechanism of degradation. Degradation products were identified by high performance liquid chromatography (HPLC-DAD) and UHPLC-Orbitrap-MS analyses. A simple mechanism of degradation for different AOP was proposed. Thirteen products were identified during all degradations for both pesticides. It was assumed that the oxidation mechanisms in the all four technologies were not based only on the production and use of the hydroxyl radical, but they also included other kinds of oxidation mechanisms specific for each technology. Similarity was observed between degradation mechanism of ozonation and DBD. The greatest difference in the products was found in Fenton degradation which included the opening of benzene ring. When degraded with same AOP pesticides gave at the end of treatment the same products. Global toxicity and COD value of samples was determined after all degradations. Real water sample was used to study influence of organic matter on pesticide degradation. These results could lead to accurate estimates of the overall effects of triketone herbicides on environmental ecosystems and also contributed to the development of improved removal processes.


Asunto(s)
Ciclohexanonas/análisis , Herbicidas/análisis , Cetonas/química , Mesilatos/análisis , Oxígeno/química , Purificación del Agua/métodos , Animales , Artemia , Benceno/química , Carbono/química , Catálisis , Cromatografía Líquida de Alta Presión , Ciclohexanonas/química , Relación Dosis-Respuesta a Droga , Ecosistema , Herbicidas/química , Peróxido de Hidrógeno/química , Hierro/química , Espectrometría de Masas , Mesilatos/química , Modelos Químicos , Compuestos Orgánicos , Ozono , Plaguicidas , Fotoquímica , Factores de Tiempo , Pruebas de Toxicidad , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...