Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 74
1.
Int J Mol Sci ; 24(7)2023 Apr 06.
Article En | MEDLINE | ID: mdl-37047808

Barrier membranes are an essential tool in guided bone Regeneration (GBR), which have been widely presumed to have a bioactive effect that is beyond their occluding and space maintenance functionalities. A standardized calvaria implantation model was applied for 2, 8, and 16 weeks on Wistar rats to test the interactions between the barrier membrane and the underlying bone defects which were filled with bovine bone substitute materials (BSM). In an effort to understand the barrier membrane's bioactivity, deeper histochemical analyses, as well as the immunohistochemical detection of macrophage subtypes (M1/M2) and vascular endothelial cells, were conducted and combined with histomorphometric and statistical approaches. The native collagen-based membrane was found to have ossified due to its potentially osteoconductive and osteogenic properties, forming a "bony shield" overlying the bone defects. Histomorphometrical evaluation revealed the resorption of the membranes and their substitution with bone matrix. The numbers of both M1- and M2-macrophages were significantly higher within the membrane compartments compared to the underlying bone defects. Thereby, M2-macrophages significantly dominated the tissue reaction within the membrane compartments. Statistically, a correlation between M2-macropahges and bone regeneration was only found at 2 weeks post implantationem, while the pro-inflammatory limb of the immune response correlated with the two processes at 8 weeks. Altogether, this study elaborates on the increasingly described correlations between barrier membranes and the underlying bone regeneration, which sheds a light on the understanding of the immunomodulatory features of biomaterials.


Guided Tissue Regeneration , Osteogenesis , Rats , Animals , Cattle , Endothelial Cells , Rats, Wistar , Collagen/chemistry , Bone Regeneration , Biocompatible Materials/chemistry , Membranes, Artificial
2.
Int J Mol Sci ; 24(3)2023 Feb 03.
Article En | MEDLINE | ID: mdl-36769326

Cytocompatibility analyses of new implant materials or biomaterials are not only prescribed by the Medical Device Regulation (MDR), as defined in the DIN ISO Norm 10993-5 and -12, but are also increasingly replacing animal testing. In this context, jellyfish collagen has already been established as an alternative to mammalian collagen in different cell culture conditions, but a lack of knowledge exists about its applicability for cytocompatibility analyses of biomaterials. Thus, the present study was conducted to compare well plates coated with collagen type 0 derived from Rhizostoma pulmo with plates coated with bovine and porcine collagen. The coated well plates were analysed in vitro for their cytocompatibility, according to EN ISO 10993-5/-12, using both L929 fibroblasts and MC3T3 pre-osteoblasts. Thereby, the coated well plates were compared, using established materials as positive controls and a cytotoxic material, RM-A, as a negative control. L929 cells exhibited a significantly higher viability (#### p < 0.0001), proliferation (## p < 0.01), and a lower cytotoxicity (## p < 0.01 and # p < 0.05)) in the Jellagen® group compared to the bovine and porcine collagen groups. MC3T3 cells showed similar viability and acceptable proliferation and cytotoxicity in all collagen groups. The results of the present study revealed that the coating of well plates with collagen Type 0 derived from R. pulmo leads to comparable results to the case of well plates coated with mammalian collagens. Therefore, it is fully suitable for the in vitro analyses of the cytocompatibility of biomaterials or medical devices.


Cnidaria , Scyphozoa , Animals , Cattle , Biocompatible Materials/pharmacology , Collagen , Cell Line , Mammals
3.
In Vivo ; 37(1): 320-328, 2023.
Article En | MEDLINE | ID: mdl-36593025

BACKGROUND/AIM: The aim of this study was the conception, production, material analysis and cytocompatibility analysis of a new collagen foam for medical applications. MATERIALS AND METHODS: After the innovative production of various collagen sponges from bovine sources, the foams were analyzed ex vivo in terms of their structure (including pore size) and in vitro in terms of cytocompatibility according to EN ISO 10993-5/-12. In vitro, the collagen foams were compared with the established biomaterials cerabone and Jason membrane. Materials cerabone and Jason membrane. RESULTS: Collagen foams with different compositions were successfully produced from bovine sources. Ex vivo, the foams showed a stable and long-lasting primary structure quality with a bubble area of 1,000 to 2,000 µm2 In vitro, all foams showed sufficient cytocompatibility. CONCLUSION: Collagen sponges represent a promising material for hard and soft tissue regeneration. Future studies could focus on integrating and investigating different additives in the foams.


Biocompatible Materials , Collagen , Animals , Cattle , Hydroxyapatites
4.
Acta Biomater ; 157: 720-733, 2023 02.
Article En | MEDLINE | ID: mdl-36460289

Bioabsorbable magnesium implants for orthopedic fixation of bone have recently become available for different fields of indication. While general questions of biocompatibility have been answered, tailoring suitable degradation kinetics for specific applications as well as long-term tissue integration remain the focus of current research. The aim of this study was the evaluation of the long-term degradation behavior and osseointegration of Mg-Ca-Zn (ZX00MEO) based magnesium implants with plasma-electrolytic oxidation (PEO) surface modification (ZX00MEO-PEO) in comparison to non-surface modified implants in vivo and in vitro. Besides a general evaluation of the biological performance of the alloy over a prolonged period, the main hypothesis was that PEO surface modification significantly reduces implant degradation rate and improves tissue interaction. In vitro, the microstructure and surface of the bioabsorbable screws were characterized by SEM/EDS, cytocompatibility and degradation testing facilitating hydrogen gas evolution, carried out following ISO 10993-5/-12 and ASTM F3268-18a/ASTM G1-03 (E1:2017). In vivo, screws were implanted in the frontal bone of Minipigs for 6, 12, and 18 months, following radiological and histomorphometric analysis. A slower and more uniform degradation and improved cytocompatibility could be shown for the ZX00MEO-PEO group in vitro. A significant reduction of degradation rate and enhanced bone formation around the ZX00MEO-PEO screws in vivo was confirmed. Proficient biocompatibility and tissue integration could generally be shown in vivo regardless of surface state. The tested magnesium alloy shows generally beneficial properties as an implant material, while PEO-surface modification further improves the bioabsorption behavior both in vitro and in vivo. STATEMENT OF SIGNIFICANCE: Devices from bioabsorbable Magnesium have recently been introduced to orthopedic applications. However, the vast degradation of Magnesium within the human body still gives limitations. While reliable in-vivo data on most promising surface treatments such as Plasma-electrolytic-Oxidation is generally scarce, long-time results in large animals are to this date completely missing. To overcome this lack of evidence, we studied a Magnesium-Calzium-Zinc-alloy with surface enhancement by PEO for the first time ever over a period of 18 months in a large animal model. In-vitro, surface-modified screws showed significantly improved cytocompatibility and reduction of degradation confirmed by hydrogen gas evolution testing, while in-vivo radiological and histological evaluation generally showed good biocompatibility and bioabsorption as well as significantly enhanced reduction of degradation and faster bone regeneration in the PEO-surface-modified group.


Magnesium , Prostheses and Implants , Swine , Animals , Humans , Swine, Miniature , Magnesium/pharmacology , Magnesium/chemistry , Alloys/pharmacology , Alloys/chemistry , Hydrogen , Materials Testing
5.
Int J Mol Sci ; 23(23)2022 Nov 29.
Article En | MEDLINE | ID: mdl-36499315

Guided bone regeneration (GBR) has become a clinically standard modality for the treatment of localized jawbone defects. Barrier membranes play an important role in this process by preventing soft tissue invasion outgoing from the mucosa and creating an underlying space to support bone growth. Different membrane types provide different biological mechanisms due to their different origins, preparation methods and structures. Among them, collagen membranes have attracted great interest due to their excellent biological properties and desired bone regeneration results to non-absorbable membranes even without a second surgery for removal. This work provides a comparative summary of common barrier membranes used in GBR, focusing on recent advances in collagen membranes and their biological mechanisms. In conclusion, the review article highlights the biological and regenerative properties of currently available barrier membranes with a particular focus on bioresorbable collagen-based materials. In addition, the advantages and disadvantages of these biomaterials are highlighted, and possible improvements for future material developments are summarized.


Guided Tissue Regeneration, Periodontal , Guided Tissue Regeneration , Guided Tissue Regeneration, Periodontal/methods , Membranes, Artificial , Bone Regeneration , Collagen , Biocompatible Materials , Polytetrafluoroethylene
6.
In Vivo ; 36(5): 2042-2051, 2022.
Article En | MEDLINE | ID: mdl-36099106

BACKGROUND/AIM: Macrophages and biomaterial-induced multinucleated giant cells (BMGCs) are central elements in the tissue reaction cascade towards bone substitute materials (BSM). The enzymatic detection of the lytic enzyme tartrate-resistant acid phosphatase (TRAP) has manifoldly been used to examine the so-called "bioactivity" of BSM. The present study aimed to compare the detection validity and expression pattern of the TRAP enzyme using enzymatic and immunohistochemical detection methods in the context of biocompatibility analyses of BSM. PATIENTS AND METHODS: Biopsies from 8 patients were analyzed after sinus augmentation with a xenogeneic bone substitute. Analysis of both macrophage and BMGC polarization were performed by histochemical TRAP detection and immunohistochemical detection of TRAP5a. Histomorphometrical analysis was used for comparison of the TRAP detection of BMGCs. RESULTS: The enzymatic TRAP detection method revealed that in 7 out of 8 biopsies only single cells were TRAP-positive, whereas most of the cells and especially the BMGCs were TRAP-negative. The immunohistochemical detection of TRAP5a showed moderate numbers of stained mononuclear cells, while the majority of the BMGCs showed signs of TRAP5a-expression. The enzymatic TRAP detection was comparable to the results obtained via immunohistochemistry only in one case. The histomorphometrical analysis showed that significantly more mononuclear and multinucleated TRAP-positive cells were found using immunohistochemical TRAP5a-staining compared to the enzymatic TRAP detection method. Also, significantly more TRAP-negative BMGCs were found using the enzymatic TRAP detection. CONCLUSION: The immunohistochemical detection of TRAP is more accurate for examination of the bioactivity and cellular degradability of BSM.


Bone Substitutes , Acid Phosphatase/analysis , Acid Phosphatase/metabolism , Biocompatible Materials , Humans , Immunohistochemistry , Tartrate-Resistant Acid Phosphatase
7.
In Vivo ; 36(5): 2149-2165, 2022.
Article En | MEDLINE | ID: mdl-36099113

BACKGROUND: Bioglass is a highly adoptable bone substitute material which can be combined with so-called therapeutic ions. However, knowledge is poor regarding the influence of therapeutic ions on immune reactions and associated bone healing. Thus, the aim of this work was to investigate the influence of strontium- and copper-doped bioglass on the induction of M1 and M2 macrophages, as well as vascularization. MATERIALS AND METHODS: Two types of alkali glass were produced based on ICIE16 bioglass via the melt-quench method with the addition of 5 wt% copper or strontium (ICIE16-Cu and ICIE16-Sr). Pure ICIE16 and 45S5 bioglass were used as control materials. The ion release and chemical composition of the bioglass were investigated, and an in vivo experiment was subcutaneously performed on Sprague-Dawley rats. RESULTS: Scanning electron microscopy revealed significant differences in the surface morphology of the bioglass materials. Energy dispersive X-ray spectroscopy confirmed the efficiency of the doping process by showing the ion-release kinetics. ICIE16-Cu exhibited a higher ion release than ICIE16-Sr. ICIE16-Cu induced low immune cell migration and triggered not only a low number of M1 and M2 macrophages but also of blood vessels. ICIE16-Sr induced higher numbers of M1 macrophages after 30 days. Both bioglass types induced numbers of M2 macrophages comparable with those found in the control groups. CONCLUSION: Bioglass doping with copper and strontium did not significantly influence the foreign body response nor vascularization of the implantation bed in vivo. However, all the studied bioglass materials seemed to be biocompatible.


Copper , Strontium , Animals , Ceramics , Copper/pharmacology , Immunity , Ions , Rats , Rats, Sprague-Dawley , Strontium/pharmacology
8.
Int J Mol Sci ; 23(18)2022 Sep 13.
Article En | MEDLINE | ID: mdl-36142541

Although various studies have investigated differences in the tissue reaction pattern to synthetic and xenogeneic bone substitute materials (BSMs), a lack of knowledge exists regarding the classification of both materials based on the DIN ISO 10993-6 scoring system, as well as the histomorphometrical measurement of macrophage subtypes within their implantation beds. Thus, the present study was conducted to analyze in vivo responses to both xenogeneic and synthetic bone substitute granules. A standardized calvaria implantation model in Wistar rats, in combination with established scoring, histological, histopathological, and histomorphometrical methods, was conducted to analyze the influence of both biomaterials on bone regeneration and the immune response. The results showed that the application of the synthetic BSM maxresorb® induced a higher pro-inflammatory tissue response, while the xenogeneic BSM cerabone® induced a higher anti-inflammatory reaction. Additionally, comparable bone regeneration amounts were found in both study groups. Histopathological scoring revealed that the synthetic BSM exhibited non-irritant scores at all timepoints using the xenogeneic BSM as control. Overall, the results demonstrated the biocompatibility of synthetic BSM maxresorb® and support the conclusion that this material class is a suitable alternative to natural BSM, such as the analyzed xenogeneic material cerabone®, for a broad range of indications.


Bone Substitutes , Animals , Anti-Inflammatory Agents , Biocompatible Materials/pharmacology , Bone Regeneration , Bone Substitutes/pharmacology , Calcium Phosphates , Hydroxyapatites , Immunity , Rats , Rats, Wistar
9.
Front Bioeng Biotechnol ; 10: 983988, 2022.
Article En | MEDLINE | ID: mdl-36032705

Bioactive cations, including calcium, copper and magnesium, have shown the potential to become the alternative to protein growth factor-based therapeutics for bone healing. Ion substitutions are less costly, more stable, and more effective at low concentrations. Although they have been shown to be effective in providing bone grafts with more biological functions, the precise control of ion release kinetics is still a challenge. Moreover, the synergistic effect of three or more metal ions on bone regeneration has rarely been studied. In this study, vaterite-calcite CaCO3 particles were loaded with copper (Cu2+) and magnesium (Mg2+). The polyelectrolyte multilayer (PEM) was deposited on CaCuMg-CO3 particles via layer-by-layer technique to further improve the stability and biocompatibility of the particles and to enable controlled release of multiple metal ions. The PEM coated microcapsules were successfully combined with collagen at the outmost layer, providing a further stimulating microenvironment for bone regeneration. The in vitro release studies showed remarkably stable release of Cu2+ in 2 months without initial burst release. Mg2+ was released in relatively low concentration in the first 7 days. Cell culture studies showed that CaCuMg-PEM-Col microcapsules stimulated cell proliferation, extracellular maturation and mineralization more effectively than blank control and other microcapsules without collagen adsorption (Ca-PEM, CaCu-PEM, CaMg-PEM, CaCuMg-PEM). In addition, the CaCuMg-PEM-Col microcapsules showed positive effects on osteogenesis and angiogenesis in gene expression studies. The results indicate that such a functional and controllable delivery system of multiple bioactive ions might be a safer, simpler and more efficient alternative of protein growth factor-based therapeutics for bone regeneration. It also provides an effective method for functionalizing bone grafts for bone tissue engineering.

10.
Clin Oral Investig ; 26(8): 5261-5272, 2022 Aug.
Article En | MEDLINE | ID: mdl-35593928

OBJECTIVES: The present randomized controlled clinical study aimed to investigate if, in lateral maxillary sinus augmentation, the repositioned bony wall or the application of a collagen membrane results in more preferable new hard tissue formation. MATERIALS AND METHODS: Forty patients were divided into two study groups. Both groups received a xenogeneic bone substitute material (BSM) during lateral sinus augmentation. In the bony wall group (BW), following piezosurgery, the retrieved bony wall was repositioned. In the collagen membrane group (CM), following rotary instrument preparation, collagen membrane coverage was applied. After 6 months, biopsies were taken to histologically analyze the percentage of BSM, connective tissue (CT), and newly formed bone (NFB) following both approaches. RESULTS: Forty implants were placed and 29 harvested biopsies could be evaluated. Duration of surgery, membrane perforations, and VAS were detected. Histomorphometrical analysis revealed comparable amounts of all analyzed parameters in both groups in descending order: CT (BW: 39.2 ± 9%, CM: 37,9 ± 8.5%) > BSM (BW: 32.9 ± 6.3%, CM: 31.8 ± 8.8%) > NB (BW: 27.8 ± 11.2%, CM: 30.3 ± 4.5%). CONCLUSIONS: The results of the present study show that the closure of the access window by means of the retrieved bony wall or a native collagen membrane led to comparable bone augmentation results. CLINICAL TRIAL: clinicaltrials.gov NCT04811768. CLINICAL RELEVANCE: Lateral maxillary sinus augmentation with the application of a xenogeneic BSM in combination with a native collagen membrane for bony window coverage represents a reliable method for surgical reconstruction of the posterior maxilla. Piezosurgery with bony window repositioning delivers comparable outcomes without membrane coverage.


Bone Substitutes , Sinus Floor Augmentation , Transverse Sinuses , Bone Regeneration , Collagen , Dental Implantation, Endosseous/methods , Humans , Maxilla/pathology , Maxilla/surgery , Maxillary Sinus/pathology , Maxillary Sinus/surgery , Prospective Studies , Sinus Floor Augmentation/methods , Transverse Sinuses/surgery
11.
Membranes (Basel) ; 12(4)2022 Mar 30.
Article En | MEDLINE | ID: mdl-35448348

Collagen-based barrier membranes are nowadays the prevalent option for Guided Bone Regeneration (GBR) procedures. Xenogeneic collagen is highly biocompatible as it shares a similar structure to native human collagen, which prevents it from eliciting an exaggerated host immune response. Most commercially available collagen barrier membranes are porcine-derived, while bovine-derived alternatives are still rarely available. The aim of the present study was to investigate the tissue responses and the barrier functionality of a novel GBR membrane composed of bovine collagen type I (BM). Therefore, the subcutaneous implantation model in Wistar rats was performed to compare the novel medical device with two already clinically used native porcine-based barrier membranes, i.e., Jason® membrane (JM) and Bio-Gide® (BG), at 10-, 30-, 60-, and 90-days post implantationem. Histochemical and immunohistochemical stains were used for histopathological evaluation including a biocompatibility scoring according to the DIN EN ISO 10993-6 norm as well as histomorphometrical analyses of the occurrence of M1 and M2 macrophages and the transmembraneous vascularization. The bovine membrane exhibited a host tissue reaction that was comparable to both control materials, which was verified by the scoring results and the histomorphometrical macrophage measurements. Moreover, the novel membrane exhibited an integration pattern without material fragmentation up to day 60. At day 90, material fragmentation was observable that allowed for "secondary porosity" including transmembrane vascularization. The results of this study suggest that the novel bovine barrier membrane is fully biocompatible and suitable for indications that require GBR as a suitable alternative to porcine-sourced barrier membranes.

12.
Biomedicines ; 10(2)2022 Feb 01.
Article En | MEDLINE | ID: mdl-35203565

In general, only a total of four tissue classes are distinguished: the covering tissue (epithelial tissue), the connective and supporting tissue (connective tissue, fatty tissue, bone, and cartilage), the muscle tissue, and the nervous tissue [...].

13.
Int J Mol Sci ; 23(3)2022 Jan 21.
Article En | MEDLINE | ID: mdl-35163120

Injectable bone substitutes (IBS) are increasingly being used in the fields of orthopedics and maxillofacial/oral surgery. The rheological properties of IBS allow for proper and less invasive filling of bony defects. Vaterite is the most unstable crystalline polymorph of calcium carbonate and is known to be able to transform into hydroxyapatite upon contact with an organic fluid (e.g., interstitial body fluid). Two different concentrations of hydrogels based on poly(ethylene glycol)-acetal-dimethacrylat (PEG-a-DMA), i.e., 8% (w/v) (VH-A) or 10% (w/v) (VH-B), were combined with vaterite nanoparticles and implanted in subcutaneous pockets of BALB/c mice for 15 and 30 days. Explants were prepared for histochemical staining and immunohistochemical detection methods to determine macrophage polarization, and energy-dispersive X-ray analysis (EDX) to analyze elemental composition was used for the analysis. The histopathological analysis revealed a comparable moderate tissue reaction to the hydrogels mainly involving macrophages. Moreover, the hydrogels underwent a slow cellular infiltration, revealing a different degradation behavior compared to other IBS. The immunohistochemical detection showed that M1 macrophages were mainly found at the material surfaces being involved in the cell-mediated degradation and tissue integration, while M2 macrophages were predominantly found within the reactive connective tissue. Furthermore, the histomorphometrical analysis revealed balanced numbers of pro- and anti-inflammatory macrophages, demonstrating that both hydrogels are favorable materials for bone tissue regeneration. Finally, the EDX analysis showed a stepwise transformation of the vaterite particle into hydroxyapatite. Overall, the results of the present study demonstrate that hydrogels including nano-vaterite particles are biocompatible and suitable for bone tissue regeneration applications.


Bone Regeneration , Bone Substitutes/pharmacology , Calcium Carbonate/pharmacology , Hydrogels/administration & dosage , Macrophages/immunology , Wound Healing , Animals , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Bone Substitutes/chemistry , Calcium Carbonate/chemistry , Electron Probe Microanalysis , Hydrogels/chemistry , Macrophages/drug effects , Male , Mice , Mice, Inbred BALB C , Microscopy, Electron, Scanning , Polyethylene Glycols/chemistry , Spectrometry, X-Ray Emission
14.
In Vivo ; 36(1): 63-75, 2022.
Article En | MEDLINE | ID: mdl-34972701

BACKGROUND/AIM: Cardiovascular diseases are one of the most common causes of morbidity and mortality in the world. In the case of severe arteriosclerotic damage, surgical treatment is necessary. Although the use of autologous vessels is still considered to be the gold standard, sufficient autologous vessels for transplantation are lacking. MATERIALS AND METHODS: In the present study, histological examination and in vitro cytotoxicity analysis according to DIN EN ISO 10993-5 were performed on a newly developed porcine vascular graft from a decellularized aorta. A conventional bovine graft was used as control. RESULTS: The ex vivo-histological analysis revealed the effectiveness of a new purification process on the microstructure and the removal of xenogeneic antigen-bearing structures in the new vessels. Furthermore, cell viability and cytotoxicity assays revealed full cytocompatibility. CONCLUSION: The novel graft shows no structural damage and gets completely decellularized by the purification process. Superior cytocompatibility, compared with the bovine-derived vascular graft, was demonstrated.


Aorta , Animals , Cattle , Swine
15.
J Reconstr Microsurg ; 38(1): 47-55, 2022 Jan.
Article En | MEDLINE | ID: mdl-34154025

BACKGROUND: Progress in the field of microsurgery allows more detailed reconstructions of the smallest tissue structures. The applied instruments are left with biological residues after coming into contact with body fluids or tissue, leading to compromised surgical precision. Designing of residue-free innovative instruments would reduce the necessity of subsidiary practices and would improve the surgical precision. METHODS: We designed a ceramic coating (Lotus ceramic coating system 26-LCC-26) that exhibits self-cleaning surface properties on coated titanium specimens. A titanium surface was modified by blasting technology and electropolishing, followed by applying a high-performance ceramic and sol-gel finish layer. The physical surface characterization was performed by scanning electron microscopy and measuring the contact angle. The cell-repellent properties and cytotoxicity were investigated using live-dead staining, BrdU, and lactate dehydrogenase assay. Furthermore, bacterial and fluid-adhesion tests were performed. Finally, blood compatibility was analyzed according to DIN ISO 10993. RESULTS: The composite system LCC-26 increased the hydrophobic character of the titanium surface (the water contact angle of 74.9 degrees was compared with 62.7 degrees of the uncoated native titanium; p < 0.01) and led to the fluid and cell-repellent properties shown by the reduction in fibroblast adherence by ∼50.7% (p < 0.05), the reduction in Staphylococcus aureus pathogen colonization by 74.1% (p < 0.001), and the decrease in erythrocyte adherence by 62.9% (p < 0.01). Furthermore, the LCC-26 coated titanium microforceps dipped in human whole blood exhibited blood-repellent character (reduction in blood adherence by 46.1%; p < 0.05). Additionally, cyto- and hemocompatibility was guaranteed in direct and indirect tests. CONCLUSION: Titanium surface modification on surgical instruments exhibits cell, bacteria, and blood-repellent properties with a full guarantee of cyto- and hemocompatibility. Thus, innovatively coated instruments could contribute to increased precision during microsurgical interventions and optimized medical operation routines in the future.


Microsurgery , Titanium , Bacteria , Blood Cells , Ceramics , Humans , Surface Properties
16.
Materials (Basel) ; 14(23)2021 Dec 01.
Article En | MEDLINE | ID: mdl-34885527

The physicochemical properties of synthetically produced bone substitute materials (BSM) have a major impact on biocompatibility. This affects bony tissue integration, osteoconduction, as well as the degradation pattern and the correlated inflammatory tissue responses including macrophages and multinucleated giant cells (MNGCs). Thus, influencing factors such as size, special surface morphologies, porosity, and interconnectivity have been the subject of extensive research. In the present publication, the influence of the granule size of three identically manufactured bone substitute granules based on the technology of hydroxyapatite (HA)-forming calcium phosphate cements were investigated, which includes the inflammatory response in the surrounding tissue and especially the induction of MNGCs (as a parameter of the material degradation). For the in vivo study, granules of three different size ranges (small = 0.355-0.5 mm; medium = 0.5-1 mm; big = 1-2 mm) were implanted in the subcutaneous connective tissue of 45 male BALB/c mice. At 10, 30, and 60 days post implantationem, the materials were explanted and histologically processed. The defect areas were initially examined histopathologically. Furthermore, pro- and anti-inflammatory macrophages were quantified histomorphometrically after their immunohistochemical detection. The number of MNGCs was quantified as well using a histomorphometrical approach. The results showed a granule size-dependent integration behavior. The surrounding granulation tissue has passivated in the groups of the two bigger granules at 60 days post implantationem including a fibrotic encapsulation, while a granulation tissue was still present in the group of the small granules indicating an ongoing cell-based degradation process. The histomorphometrical analysis showed that the number of proinflammatory macrophages was significantly increased in the small granules at 60 days post implantationem. Similarly, a significant increase of MNGCs was detected in this group at 30 and 60 days post implantationem. Based on these data, it can be concluded that the integration and/or degradation behavior of synthetic bone substitutes can be influenced by granule size.

17.
Int J Mol Sci ; 22(22)2021 Nov 22.
Article En | MEDLINE | ID: mdl-34830451

Background: Magnesium (Mg) is one of the most promising materials for human use in surgery due to material characteristics such as its elastic modulus as well as its resorbable and regenerative properties. In this study, HF-coated and uncoated novel bioresorbable magnesium fixation screws for maxillofacial and dental surgical applications were investigated in vitro and in vivo to evaluate the biocompatibility of the HF coating. Methods: Mg alloy screws that had either undergone a surface treatment with hydrofluoric-acid (HF) or left untreated were investigated. In vitro investigation included XTT, BrdU and LDH in accordance with the DIN ISO 10993-5/-12. In vivo, the screws were implanted into the tibia of rabbits. After 3 and 6 weeks, degradation, local tissue reactions and bony integration were analyzed histopathologically and histomorphometrically. Additionally, SEM/EDX analysis and synchrotron phase-contrast microtomography (µCT) measurements were conducted. The in vitro analyses revealed that the Mg screws are cytocompatible, with improved results when the surface had been passivated with HF. In vivo, the HF-treated Mg screws implanted showed a reduction in gas formation, slower biodegradation and a better bony integration in comparison to the untreated Mg screws. Histopathologically, the HF-passivated screws induced a layer of macrophages as part of its biodegradation process, whereas the untreated screws caused a slight fibrous tissue reaction. SEM/EDX analysis showed that both screws formed a similar layer of calcium phosphates on their surfaces and were surrounded by bone. Furthermore, the µCT revealed the presence of a metallic core of the screws, a faster absorbing corrosion front and a slow absorbing region of corroded magnesium. Conclusions: Overall, the HF-passivated Mg fixation screws showed significantly better biocompatibility in vitro and in vivo compared to the untreated screws.


Bone Regeneration/drug effects , Bone Screws/adverse effects , Guided Tissue Regeneration , Magnesium/pharmacology , Animals , Bone Regeneration/genetics , Cell Line , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Humans , Hydrofluoric Acid/chemistry , Hydrofluoric Acid/pharmacology , Magnesium/adverse effects , Materials Testing , Mice , Orthognathic Surgical Procedures/trends , Osteoblasts/drug effects
18.
Dent J (Basel) ; 9(11)2021 Oct 25.
Article En | MEDLINE | ID: mdl-34821591

GBR (guided bone regeneration) is a standard procedure for building up bony defects in the jaw. In this procedure, resorbable membranes made of bovine and porcine collagen are increasingly being used, which, in addition to many possible advantages, could have the potential disadvantage of a shorter barrier functionality, especially when augmenting large-volume defects. Thus, it is of importance to evaluate the integration behavior and especially the standing time of barrier membranes using specialized methods to predict its respective biocompatibility. This study is intended to establish a new histomorphometrical analysis method to quantify the integration rate of collagen-based barrier membranes. Three commercially available barrier membranes, i.e., non-crosslinked membranes (BioGide® and Jason® membrane), a ribose-crosslinked membrane (Ossix® Plus), and a newly developed collagen-hyaluronic acid-based (Coll-HA) barrier membrane were implanted in the subcutaneous tissue of 48 6-8-week-old Wistar rats. The explants, after three timepoints (10, 30, and 60 days), were processed and prepared into histological sections for histopathological (host tissue response) and histomorphometrical (cellular invasion) analyses. 10 days after implantation, fragmentation was not evident in any of the study groups. The sections of the Coll-HA, Jason® and BioGide® membranes showed a similar mild inflammatory reaction within the surrounding tissue and an initial superficial cell immigration. Only in the Ossix® Plus group very little inflammation and no cell invasion was detected. While the results of the three commercially available membranes remained intact in the further course of the study, only fragments of the Coll-HA membrane were found 30 and 60 days after implantation. Histomorphometrically, it can be described that although initially (at 10 days post-implantation) similar results were found in all study groups, after 30 days post-implantation the cellular penetration depth of the hyaluronic acid-collagen membrane was significantly increased with time (**** p < 0.0001). Similarly, the percentage of cellular invasion per membrane thickness was also significantly higher in the Coll-HA group at all timepoints, compared to the other membranes (**** p < 0.0001). Altogether, these results show that the histomorphometrical analysis of the cellular migration can act as an indicator of integration and duration of barrier functionality. Via this approach, it was possible to semi-quantify the different levels of cellular penetration of GBR membranes that were only qualitatively analyzed through histopathological approaches before. Additionally, the results of the histopathological and histomorphometrical analyses revealed that hyaluronic acid addition to collagen does not lead to a prolonged standing time, but an increased integration of a collagen-based biomaterial. Therefore, it can only partially be used in the dental field for indications that require fast resorbed membranes and a fast cell or tissue influx such as periodontal regeneration processes.

19.
In Vivo ; 35(6): 3011-3017, 2021.
Article En | MEDLINE | ID: mdl-34697132

In many medical disciplines, the process of drilling into the bone plays a crucial role for the implantation or fixation of implants or reconstruction plates. During the bone drilling process, heat is generated on the drill head and within the surrounding tissue. As a result, the increased temperature can lead to thermal damage and related necrosis of the (bone) tissue. This tissue damage is dependent on different drilling parameters and can have important influence on the following tissue healing cascade and finally on implant surveillance. In this context, the present short review elucidates the current state of scientific knowledge with regard to the heat-triggering factors during the bony drilling process and how these factors can be better understood and prevented, now and in the future, through new research approaches. External and internal influencing factors during the drilling process are distinguished and methods to examine the temperature changes are compared. This mini-review further demonstrates first preliminary results of the inflammatory tissue reactions to inadequate drilling processes. Furthermore, possible solutions of new standardized ex vivo-measurement methods to better understand the factors influencing the development of heat and to reduce animal experiments are herein discussed.


Bone and Bones , Hot Temperature , Animals
20.
Int J Mol Sci ; 22(17)2021 Aug 25.
Article En | MEDLINE | ID: mdl-34502107

Skin regeneration is a quite complex process. Epidermal differentiation alone takes about 30 days and is highly regulated. Wounds, especially chronic wounds, affect 2% to 3% of the elderly population and comprise a heterogeneous group of diseases. The prevailing reasons to develop skin wounds include venous and/or arterial circulatory disorders, diabetes, or constant pressure to the skin (decubitus). The hallmarks of modern wound treatment include debridement of dead tissue, disinfection, wound dressings that keep the wound moist but still allow air exchange, and compression bandages. Despite all these efforts there is still a huge treatment resistance and wounds will not heal. This calls for new and more efficient treatment options in combination with novel biocompatible skin scaffolds. Cold atmospheric pressure plasma (CAP) is such an innovative addition to the treatment armamentarium. In one CAP application, antimicrobial effects, wound acidification, enhanced microcirculations and cell stimulation can be achieved. It is evident that CAP treatment, in combination with novel bioengineered, biocompatible and biodegradable electrospun scaffolds, has the potential of fostering wound healing by promoting remodeling and epithelialization along such temporarily applied skin replacement scaffolds.


Plasma Gases/chemistry , Pressure Ulcer/therapy , Tissue Scaffolds/chemistry , Wound Healing , Animals , Humans , Nanofibers/chemistry , Pressure Ulcer/pathology
...