Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38477187

RESUMEN

OBJECTIVE: Large-for-gestational-age (LGA) is associated with several adverse maternal and neonatal outcomes. Although many studies have found that early induction of labor (eIOL) in LGA reduces the incidence of shoulder dystocia (SD), no current guidelines recommend this particular strategy, due to concerns about increased rates of cesarean delivery (CD) and neonatal complications. The purpose of this study was to assess whether the timing of IOL in LGA fetuses affects maternal and neonatal outcomes in a single center; and to combine these results with the evidence reported in the literature. METHODS: This study comprised two parts. The first was a retrospective cohort study that included: consecutive patients with singleton pregnancy, an estimated fetal weight (EFW) ≥90th percentile on ultrasound (US) between 35+0 and 39+0 weeks of gestation (WG), who were eligible for normal vaginal delivery. The second part was a systematic review of literature and meta-analysis that included the results of the first part as well as all previously reported studies that have compared IOL to expectant management in patients with LGA. The perinatal outcomes were CD, operative vaginal delivery (OVD), SD, brachial plexus palsy, anal sphincter injury, postpartum hemorrhage (PPH), APGAR score, umbilical arterial pH, neonatal intensive care unit (NICU) admission, use of continuous positive airway pressure (CPAP), intracranial hemorrhage (ICH), phototherapy, and bone fracture. RESULTS: Retrospective cohort: of the 547 patients, 329 (60.1%) were induced and 218 (39.9%) entered spontaneous labor. Following covariate balancing, CD was significantly higher in the IOL group in comparison to the spontaneous labor group. This difference only became apparent beyond 40WG (hazard ratio: 1.9, p=0.030). The difference between both groups for shoulder dystocia was not statistically significant. Systematic review and metanalysis: 17 studies were included in addition to our own results giving a total sample size of 111,300 participants. When IOL was performed <40+0WG, the risk for SD was significantly lower in the IOL group (OR: 0.64, 95%CI: 0.42-0.98, I2 =19%). There was no significant difference in CD rate between IOL and expectant management after pooling the results of these 17 studies. However, when removing the studies in which IOL was done exclusively before 40+0WG, the risk for CD in the remaining studies (IOL not exclusively <40+0WG) was significantly higher in the IOL group (odds ratio [OR]: 1.46, 95% confidence interval [95%CI]: 1.02-2.09, I2 =56%). There were no statistically significant differences between IOL and expectant management for the remaining perinatal outcomes. Nulliparity, history of CD, and low Bishop score but not methods of induction were independent risk factors for intrapartum CD in patients who were induced for LGA. CONCLUSION: Timing of IOL in patients with suspected macrosomia significantly impacts perinatal adverse outcomes. IOL has no impact on rates of SD but does increase CD when considered irrespective of gestational age, but it may decrease the risk of SD without increasing the risk of other adverse maternal outcomes, in particular cesarean section when performed before 40+0 WG. (GRADE: Low/Very low). This article is protected by copyright. All rights reserved.

2.
Ultrasound Obstet Gynecol ; 63(4): 489-496, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-37725758

RESUMEN

OBJECTIVE: To compare the performance of two-dimensional ultrasound (2D-US), three-dimensional ultrasound (3D-US) and magnetic resonance imaging (MRI) at 36 weeks' gestation in predicting the delivery of a large-for-gestational-age (LGA) neonate, defined as birth weight ≥ 95th percentile, in patients at high and low risk for macrosomia. METHODS: This was a secondary analysis of a prospective observational study conducted between January 2017 and February 2019. Women with a singleton pregnancy at 36 weeks' gestation underwent 2D-US, 3D-US and MRI within 15 min for estimation of fetal weight. Weight estimations and birth weight were plotted on a growth curve to obtain percentiles for comparison. Participants were considered high risk if they had at least one of the following risk factors: diabetes mellitus, estimated fetal weight ≥ 90th percentile at the routine third-trimester ultrasound examination, obesity (prepregnancy body mass index ≥ 30 kg/m2) or excessive weight gain during pregnancy. The outcome was the diagnostic performance of each modality in the prediction of birth weight ≥ 95th percentile, expressed as the area under the receiver-operating-characteristics curve (AUC), sensitivity, specificity and positive and negative predictive values. RESULTS: A total of 965 women were included, of whom 533 (55.23%) were high risk and 432 (44.77%) were low risk. In the low-risk group, the AUCs for birth weight ≥ 95th percentile were 0.982 for MRI, 0.964 for 2D-US and 0.962 for 3D-US; pairwise comparisons were non-significant. In the high-risk group, the AUCs were 0.959 for MRI, 0.909 for 2D-US and 0.894 for 3D-US. A statistically significant difference was noted between MRI and both 2D-US (P = 0.002) and 3D-US (P = 0.002), but not between 2D-US and 3D-US (P = 0.503). In the high-risk group, MRI had the highest sensitivity (65.79%) compared with 2D-US (36.84%, P = 0.002) and 3D-US (21.05%, P < 0.001), whereas 3D-US had the highest specificity (98.99%) compared with 2D-US (96.77%, P = 0.005) and MRI (96.97%, P = 0.004). CONCLUSIONS: At 36 weeks' gestation, MRI has better performance compared with 2D-US and 3D-US in predicting birth weight ≥ 95th percentile in patients at high risk for macrosomia, whereas the performance of 2D-US and 3D-US is comparable. For low-risk patients, the three modalities perform similarly. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Macrosomía Fetal , Peso Fetal , Embarazo , Recién Nacido , Humanos , Femenino , Lactante , Peso al Nacer , Macrosomía Fetal/diagnóstico por imagen , Edad Gestacional , Ultrasonografía Prenatal/métodos , Recién Nacido Pequeño para la Edad Gestacional , Imagen por Resonancia Magnética
3.
Ultrasound Obstet Gynecol ; 61(3): 392-398, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36773302

RESUMEN

OBJECTIVE: To evaluate the prevalence of and risk factors for failure of fetal magnetic resonance imaging (MRI) due to maternal claustrophobia or malaise. METHODS: This retrospective cohort study included pregnant women who underwent fetal MRI for clinical indications or research purposes between January 2012 and December 2019 at a single center. One group included patients who completed the entire examination and the other group inlcuded patients who interrupted their MRI examination due to claustrophobia/malaise. We estimated the rate of MRI failure due to maternal claustrophobia/malaise and compared maternal and clinical variables between the two groups. Multiple logistic regression analysis was performed to identify independent risk factors for claustrophobia/malaise during MRI examination in pregnancy. RESULTS: Among 3413 patients who agreed to undergo fetal MRI, the prevalence of failure because of claustrophobia or malaise was 2.1%. The rate of claustrophobia/malaise in patients who underwent MRI for a clinical indication was lower compared to that in patients who underwent MRI for research purposes only (0.6% (4/696) vs 2.4% (65/2678); P = 0.003). Fetal MRI performed for research purposes only (adjusted odds ratio (aOR), 0.05 (95% CI, 0.01-0.48); P = 0.003), higher maternal age (aOR, 1.07 (95% CI, 1.02-1.12); P = 0.003) and later gestational age at the time of fetal MRI (aOR, 1.46 (95% CI, 1.16-2.04); P = 0.008) were independent risk factors for claustrophobia/malaise. Shorter fetal MRI duration (aOR, 0.77 (95% CI, 0.63-0.88); P = 0.001) was also associated with claustrophobia/malaise during the procedure. Body mass index, ethnic origin, multiple pregnancy, being parous and size of the magnetic bore were not associated with MRI failure due to claustrophobia/malaise. CONCLUSION: The rate of fetal MRI failure due to claustrophobia or malaise was found to be low, particularly when the examination was performed for a clinical indication, and should not be considered a common problem in the pregnant population. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Trastornos Fóbicos , Humanos , Embarazo , Femenino , Estudios Retrospectivos , Prevalencia , Factores de Riesgo , Trastornos Fóbicos/complicaciones , Trastornos Fóbicos/epidemiología , Imagen por Resonancia Magnética/métodos
4.
Ultrasound Obstet Gynecol ; 52(2): 250-257, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-28508549

RESUMEN

OBJECTIVE: To evaluate the performance of a simple semi-automated method for estimation of fetal weight (EFW) using magnetic resonance imaging (MRI) as compared with two-dimensional (2D) ultrasound (US) for the prediction of large-for-dates neonates. METHODS: Data of two groups of women with singleton pregnancy between March 2011 and May 2016 were retrieved from our database and evaluated retrospectively: the first group included women who underwent US-EFW and MRI-EFW within 48 h before delivery and the second group included women who had these evaluations between 35 + 0 weeks and 37 + 6 weeks of gestation, more than 48 h before delivery. US-EFW was based on Hadlock et al. and MRI-EFW on the formula described by Baker et al. For MRI-EFW, planimetric measurement of the fetal body volume (FBV) was performed using a semi-automated method and the time required for measurement was noted. Outcome measure was the performance of MRI-EFW vs US-EFW in the prediction of large-for-dates neonates, both ≤ 48 h and > 48 h before delivery. Receiver-operating characteristics (ROC) curves for each method were compared using the DeLong method. RESULTS: Of the 270 women included in the first group, 48 (17.8%) newborns had birth weight ≥ 90th centile and 30 (11.1%) ≥ 95th centile. The second group included 83 women, and nine (10.8%) newborns had birth weight ≥ 95th centile. Median time needed for FBV planimetric measurements in all 353 fetuses was 3.5 (range, 1.5-5.5) min. The area under the ROC curve (AUC) for prediction of large-for-dates neonates by prenatal MRI performed within 48 h before delivery was significantly higher than that by US (for birth weight ≥ 90th centile, difference between AUCs = 0.085, standard error (SE) = 0.020, P < 0.001; for birth weight ≥ 95th centile, difference between AUCs = 0.036, SE = 0.014, P = 0.01). Similarly, MRI-EFW was better than US-EFW in predicting birth weight ≥ 95th centile when both examinations were performed > 48 h prior to delivery (difference between AUCs = 0.077, SE = 0.039, P = 0.045). CONCLUSION: MRI planimetry using our purpose-designed semi-automated method is not time-consuming. The predictive performance of MRI-EFW performed immediately prior to or remote from delivery is significantly better than that of US-EFW for the prediction of large-for-dates neonates. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Macrosomía Fetal/diagnóstico por imagen , Imagen por Resonancia Magnética , Ultrasonografía Prenatal , Adulto , Peso al Nacer , Femenino , Peso Fetal , Humanos , Recién Nacido , Masculino , Valor Predictivo de las Pruebas , Embarazo , Resultado del Embarazo , Tercer Trimestre del Embarazo , Estudios Retrospectivos
5.
J Matern Fetal Neonatal Med ; 26(12): 1254-8, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23413841

RESUMEN

PURPOSE: To evaluate various factors that potentially influence the fetal body volume (FBV) measurement using magnetic resonance imaging (MRI) and to analyze whether the technique of measurement could be simplified. MATERIALS AND METHODS: In 20 singleton pregnancies scheduled for a planned delivery, FBV measurements were performed by two independent operators on sagittal, axial and coronal planes and with various slice thickness and intersection gap, totalizing 100 examinations. MR estimation of fetal weight (MR-EFW) was calculated based on the equation developed by Baker. The relative error of MR-EFW was calculated in function of birth weight (BW). Regression analysis was used to investigate the effect on the relative error of MR-EFW of different variables but also to investigate the effect on the measurement time of the FBV of various factors. RESULTS: The mean relative error of MR-EFW was 1.96% and was significantly associated only with patient's BMI but not with the type of MR sequence used or other variables. Type of MR sequence used and BW were significantly associated with the measurement time of FBV. CONCLUSION: Using MRI, the time for FBV measurement can be significantly reduced using thicker slices or intersection gap, with similar accuracy.


Asunto(s)
Tamaño Corporal , Feto , Imagen por Resonancia Magnética , Femenino , Humanos , Recién Nacido , Imagen por Resonancia Magnética/métodos , Masculino , Embarazo , Estudios Prospectivos , Análisis de Regresión
6.
Presse Med ; 14(43): 2190-2, 1985 Dec 14.
Artículo en Francés | MEDLINE | ID: mdl-2934722

RESUMEN

Using the combined abdominoperineal approach to the rectum through the recto-genital space, very low colo-rectal anastomosis can be performed without damaging the anal sphincter. Twenty-nine patients were operated upon by this procedure for malignant or benign disease of the lower two-thirds of the rectum: there was 2 failure; 6 patients developed transient perineal fistula; 27 patients now have normal anal continence. This technique has been considerably facilitated, notably in males, by stapled anastomosis.


Asunto(s)
Colon/cirugía , Recto/cirugía , Técnicas de Sutura , Abdomen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Perineo , Engrapadoras Quirúrgicas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...