Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 12(1): 15074, 2022 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-36064960

RESUMEN

Integration of single-photon emitters (SPEs) with resonant photonic structures is a promising approach for realizing compact and efficient single-photon sources for quantum communications, computing, and sensing. Efficient interaction between the SPE and the photonic cavity requires that the cavity's resonance matches the SPE's emission line. Here we demonstrate a new method for tuning silicon nitride (Si3N4) microring cavities via controlled deposition of the cladding layers. Guided by numerical simulations, we deposit silicon dioxide (SiO2) nanolayers onto Si3N4 ridge structures in steps of 50 nm. We show tuning of the cavity resonance exceeding a free spectral range (FSR) of 3.5 nm without degradation of the quality-factor (Q-factor) of the cavity. We then complement this method with localized laser heating for fine-tuning of the cavity. Finally, we verify that the cladding deposition does not alter the position and spectral properties of nanoparticles placed on the cavity, which suggests that our method can be useful for integrating SPEs with photonic structures.

2.
Nano Lett ; 20(12): 8745-8751, 2020 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-33206536

RESUMEN

Resonant metasurfaces are an attractive platform for enhancing the nonlinear optical processes, such as second harmonic generation (SHG), since they can generate large local electromagnetic fields while relaxing the phase-matching requirements. Here, we demonstrate visible range, continuous wave (CW) SHG by combining the attractive material properties of gallium phosphide with high quality-factor photonic modes enabled by bound states in the continuum. We obtain efficiencies around 5e-5% W-1 when the system is pumped at 1200 nm wavelength with CW intensities of 1 kW/cm2. Moreover, we measure external efficiencies of 0.1% W-1 with pump intensities of only 10 MW/cm2 for pulsed irradiation. This efficiency is higher than the values previously reported for dielectric metasurfaces, but achieved here with pump intensities that are two orders of magnitude lower. These results take metasurface-based SHG a step closer to practical applications.

3.
Sci Rep ; 8(1): 3792, 2018 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-29491410

RESUMEN

Nanodidamonds containing colour centres open up many applications in quantum information processing, metrology, and quantum sensing. However, controlling the synthesis of nanodiamonds containing silicon vacancy (SiV) centres is still not well understood. Here we study nanodiamonds produced by a high-pressure high-temperature method without catalyst metals, focusing on two samples with clear SiV signatures. Different growth temperatures and relative content of silicon in the initial compound between the samples altered their nanodiamond size distributions and abundance of SiV centres. Our results show that nanodiamond growth can be controlled and optimised for different applications.

4.
Sci Rep ; 7(1): 11444, 2017 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-28904390

RESUMEN

Interaction of light with media often occurs with a femtosecond response time. Its measurement by conventional techniques requires the use of femtosecond lasers and sophisticated time-gated optical detection. Here we demonstrate that by exploiting quantum interference of entangled photons it is possible to measure the dephasing time of a resonant media on the femtosecond time scale (down to 100 fs) using accessible continuous wave laser and single-photon counting. We insert a sample in the Hong-Ou-Mandel interferometer and observe the modification of the two-photon interference pattern, which is driven by the coherent response of the medium, determined by the dephasing time. The dephasing time is then inferred from the observed pattern. This effect is distinctively different from the basic effect of spectral filtering, which was studied in earlier works. In addition to its ease of use, our technique does not require compensation of group velocity dispersion and does not induce photo-damage of the samples. Our technique will be useful for characterization of ultrafast phase relaxation processes in material science, chemistry, and biology.

5.
Sci Rep ; 7: 42608, 2017 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-28218302

RESUMEN

Infrared (IR) spectroscopy is an indispensable tool for many practical applications including material analysis and sensing. Existing IR spectroscopy techniques face challenges related to the inferior performance and the high cost of IR-grade components. Here, we develop a new method, which allows studying properties of materials in the IR range using only visible light optics and detectors. It is based on the nonlinear interference of entangled photons, generated via Spontaneous Parametric Down Conversion (SPDC). In our interferometer, the phase of the signal photon in the visible range depends on the phase of an entangled IR photon. When the IR photon is traveling through the media, its properties can be found from observations of the visible photon. We directly acquire the SPDC signal with a visible range CCD camera and use a numerical algorithm to infer the absorption coefficient and the refraction index of the sample in the IR range. Our method does not require the use of a spectrometer and a slit, thus it allows achieving higher signal-to-noise ratio than the earlier developed method.

6.
Opt Lett ; 37(14): 2829-31, 2012 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-22825148

RESUMEN

The measurement of the two-mode squeezed vacuum generated in an optical parametric amplifier (OPA) was performed with photon number resolving multipixel photon counters (MPPCs). Implementation of the MPPCs allows for the observation of noise reduction in a broad dynamic range of the OPA gain, which is inaccessible with standard single photon avalanche photodetectors.

7.
Opt Express ; 20(5): 5044-51, 2012 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-22418309

RESUMEN

We present a novel method of calibration of crosstalk probability for multi-pixel photon counters (MPPCs) based on the measurement of the normalized second-order intensity correlation function of coherent light. The method was tested for several MPPCs, and was shown to be advantageous over the traditional calibration method based on the measurements of the dark noise statistics. The method can be applied without the need of modification for different kinds of spatially resolved single photon detectors.


Asunto(s)
Artefactos , Fotometría/instrumentación , Calibración , Diseño de Equipo , Análisis de Falla de Equipo , Luz , Fotones
8.
Opt Express ; 19(10): 9352-63, 2011 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-21643191

RESUMEN

In quantum optics and its applications, there is an urgent demand for photon-number resolving detectors. Recently, there appeared multi-pixel counters (MPPC) that are able to distinguish between 1,2,..10 photons. At the same time, strong coupling between different pixels (crosstalk) hinders their photon-number resolution. In this work, we suggest a method for `filtering out' the crosstalk effect in the measurement of intensity correlation functions. The developed approach can be expanded to the analysis of higher-order intensity correlations by using just a single MPPC.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...