Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Cells ; 10(5)2021 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-34063640

RESUMEN

In recent years contrast-enhanced ultrasound (CEUS) has been an emerging diagnostic modality for the detection of acute gastrointestinal (GI) graft-versus-host disease (GvHD) in patients after allogeneic stem cell transplantation. However, broad clinical usage has been partially limited by its high dependence on the expertise of an experienced examiner. Thus, the aim of this study was to facilitate detection of acute GI GvHD by implementing false color-coded parametric imaging of CEUS. As such, two inexperienced examiners with basic knowledge in abdominal and vascular ultrasound analyzed parametric images obtained from patients with clinical suspicion for acute GvHD in a blinded fashion. As diagnostic gold standard, histopathological GvHD severity score on intestinal biopsies obtained from lower GI tract endoscopy was performed. The evaluation of parametric images by the two inexperienced ultrasound examiners in patients with histological confirmation of acute GI GvHD was successful in 17 out of 19 patients (89%) as opposed to analysis of combined B-mode ultrasound, strain elastography, and CEUS by an experienced examiner, which was successful in 18 out of 19 of the patients (95%). Therefore, CEUS with parametric imaging of the intestine was technically feasible and has the potential to become a valuable diagnostic tool for rapid and widely accessible detection of acute GvHD in clinical practice.


Asunto(s)
Procedimientos Quirúrgicos del Sistema Digestivo/efectos adversos , Diagnóstico por Imagen de Elasticidad/métodos , Enfermedad Injerto contra Huésped/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Trasplante de Células Madre/efectos adversos , Ultrasonografía/métodos , Adulto , Anciano , Medios de Contraste , Diagnóstico por Imagen de Elasticidad/normas , Femenino , Enfermedad Injerto contra Huésped/patología , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/patología , Trasplante Homólogo , Ultrasonografía/normas
2.
Clin Hemorheol Microcirc ; 79(4): 541-555, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34120896

RESUMEN

BACKGROUND: A rapid decline of liver stiffness (LS) was detected by non-invasive methods in patients with chronic hepatitis C (HCV) infection during treatment with direct-acting antivirals (DAA). OBJECTIVE: To investigate the influence of inflammation on LS. METHODS: We prospectively examined LS by sonographic shear-wave elastography in 217 patients during DAA therapy from treatment initiation (BL) to 12 weeks after end of therapy (SVR12). Demographic data, laboratory findings and serum levels of cytokines were determined. RESULTS: Values of LS decreased from 1.86 m/s to 1.68 m/s (p = 0.01) which was most pronounced in patients who had F4 fibrosis at BL (3.27 m/s to 2.37 m/s; p < 0.001). Initially elevated values of aminotransferases, ferritin, IgG (p < 0.001 each) and international normalized ratio (p < 0.003) declined, thrombocyte count (p = 0.007) increased. Correlations of these laboratory parameters with BL levels of LS measurement (LSM) were most apparent in patients with F1-F3 fibrosis. Tumor necrosis factor (TNF)-α (p = 0.031), interleukin (IL)-10 (p = 0.005) and interferon y inducible protein (IP)-10 (p < 0.001) decreased in parallel with LSM under DAA therapy and corelated with BL values. CONCLUSION: Decrease of systemic inflammatory parameters correlated with LSM under DAA therapy. We conclude that regression of LSM is attributable to the decline of inflammation rather than reflecting fibrosis.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hepatitis C Crónica , Hepatitis C , Antivirales/uso terapéutico , Hepatitis C/tratamiento farmacológico , Hepatitis C/patología , Hepatitis C Crónica/diagnóstico por imagen , Hepatitis C Crónica/tratamiento farmacológico , Hepatitis C Crónica/patología , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología
3.
Clin Hemorheol Microcirc ; 78(1): 103-116, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33554890

RESUMEN

OBJECTIVE: To assess the impact and procedural input of intraoperative ultrasound (IOUS) with contrast-enhanced ultrasound (CEUS) and ultrasound elastography on surgical decision making during the procedure and consequently the outcome after hepato-pancreatico-biliary (HPB) surgery. MATERIALS AND METHODS: Data of 50 consecutive patients, who underwent HPB surgery from 04/2018 to 07/2018 were prospectively collected for this study. During surgery, IOUS with a high-resolution ultrasound device using CEUS after bolus injection of 2.4-5 ml dulphur hexafluoride microbubbles using a 6-9 MHz probe and a share wave and strain elastography was performed by an experienced examiner. Process and time analysis were carried out using mobile phone timer. RESULTS: The IOUS with CEUS and elastography correctly identified 42 malignant tumors and 4 benign lesions. In 3 cases, the examination provided false positive result (identifying 3 benign lesions as malignant) and in 1 case a malignant lesion was incorrectly assessed as benign (sensitivity 97,7%, specificity 57,1%, PPV 93,3% and NPV 80%).The specific question by the surgeon could be answered successfully in 98% of the cases. In 76% of the cases, there was a modification (42%) or a fundamental change (34%) of the planned surgical approach due to the information provided by the IOUS. Within the last group, the IOUS had a major impact on therapy outcome. In 7 patients an additional tumor resection was required, in 5 patients the tumor was assessed as inoperable, and in total in 5 patients an intraoperative RFA (4/5) or postoperative RITA (1/5) was required.Regarding procedural input, there was only a slight, but significant difference between the transport and set-up times before the intraoperative use (mean: 14 min 22 s) and the return transport (mean 13 min 6 s), (p = 0,038). The average examination time was 14 minutes, which makes only one third of the overall time demand. CONCLUSION: Combination of IOUS with CEUS and elastography in oncological HPB surgery provides valuable information that affects surgical decision-making. The procedural input of about 45 minutes seems to be a good investment considering the improvement of the surgical procedure and a significant modification of the therapy approach in the majority of the cases.


Asunto(s)
Neoplasias del Sistema Biliar/diagnóstico por imagen , Medios de Contraste/uso terapéutico , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico por imagen , Ultrasonografía/métodos , Neoplasias del Sistema Biliar/cirugía , Toma de Decisiones , Femenino , Humanos , Neoplasias Hepáticas/cirugía , Masculino , Neoplasias Pancreáticas/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA