Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Cardiol Young ; 34(2): 262-267, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37317547

RESUMEN

BACKGROUND: Lifetime radiation exposure for paediatric orthotopic heart transplant (OHT) patients is significant with cardiac catheterisation as the dominant source. Interventional cardiac magnetic resonance is utilised to obtain simultaneous, radiation-free haemodynamics and flow/function measurements. We sought to compare invasive haemodynamic measurements and radiation exposure in traditional cardiac catheterisation, to comprehensive interventional cardiac magnetic resonance. METHODS: Twenty-eight OHT patients who underwent 67 interventional cardiac magnetic resonance procedures at Children's National Hospital were identified. Both invasive oximetry with peripheral oxygen saturation (Fick) and cardiac magnetic resonance phase contrast measurements of pulmonary and systemic blood flow were performed. Systemic and pulmonary blood flow from the two modalities was compared using Bland-Altman, concordance analysis, and inter-reader correlation. A mixed model was implemented to account for confounding variables and repeat encounters. Radiation dosage data were collected for a contemporaneous cohort of orthotopic heart transplant patients undergoing standard, X-ray-guided catheterisation. RESULTS: Simultaneous cardiac magnetic resonance and Fick have poor agreement in our study based on Lin's correlation coefficient of 0.68 and 0.73 for pulmonary and systemic blood flow, respectively. Bland-Altman analysis demonstrated a consistent over estimation of cardiac magnetic resonance cardiac output by Fick. The average indexed dose area product for patients undergoing haemodynamics with endomyocardial biopsy was 0.73 (SD ±0.6) Gy*m2/kg. With coronary angiography added, the indexed dose area product was 14.6 (SD ± 7.8) Gy*m2/kg. CONCLUSIONS: Cardiac magnetic resonancemeasurements of cardiac output/index in paediatric orthotopic heart transplant patients have poor concordance with Fick estimates; however, cardiac magnetic resonance has good internal validity and inter-reader reliability. Radiation doses are small for haemodynamics with biopsy and increase exponentially with angiography, identifying a new target for cardiac magnetic resonance imaging.


Asunto(s)
Trasplante de Corazón , Imagen por Resonancia Magnética , Niño , Humanos , Reproducibilidad de los Resultados , Cateterismo Cardíaco , Oximetría/métodos , Gasto Cardíaco/fisiología , Espectroscopía de Resonancia Magnética
2.
Int J Cardiovasc Imaging ; 40(1): 83-91, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37874446

RESUMEN

T1/T2 parametric mapping may reveal patterns of elevation ("hotspots") in myocardial diseases, such as rejection in orthotopic heart transplant (OHT) patients. This study aimed to evaluate the diagnostic accuracy of free-breathing (FB) multi-parametric SAturation recovery single-SHot Acquisition (mSASHA) T1/T2 mapping in identifying hotspots present on conventional Breath-held Modified Look-Locker Inversion recovery (BH MOLLI) T1 and T2-prepared balanced steady-state free-precession (BH T2p-bSSFP) maps in pediatric OHT patients. Pediatric OHT patients underwent noncontrast 1.5T CMR with BH MOLLI T1 and T2p-bSSFP and prototype FB mSASHA T1/T2 mapping in 8 short-axis slices. FB and BH T1/T2 hotspots were segmented using semi-automated thresholding (ITK-SNAP) and their 3D coordinate locations were collected (3-Matic, Materialise, Leuven, Belgium). Receiver operator characteristic curve analysis and measures of central tendency were utilized. 40 imaging datasets from 23 pediatric OHT patients were obtained. FB mSASHA yielded a sensitivity of 82.8% for T1 and 80% for T2 maps when compared to the standard BH MOLLI, as well as 100% specificity for both T1 and T2 maps. When identified on both FB and BH maps, hotspots overlapped in all cases, with an average long axis offset between FB and BH hotspot centers of 5.8 mm (IQR 3.5-8.2) on T1 and 5.9 mm (IQR 3.5-8.2) on T2 maps. FB mSASHA T1/T2 maps can identify hotspots present on conventional BH T1/T2 maps in pediatric patients with OHT, with high sensitivity, specificity, and overlap in 3D space. Free-breathing mapping may improve patient comfort and facilitate OHT assessment in younger patient populations.


Asunto(s)
Trasplante de Corazón , Imagen por Resonancia Magnética , Humanos , Niño , Imagen por Resonancia Magnética/métodos , Valor Predictivo de las Pruebas , Corazón , Trasplante de Corazón/efectos adversos , Contencion de la Respiración , Reproducibilidad de los Resultados , Fantasmas de Imagen
3.
Catheter Cardiovasc Interv ; 102(6): 1109-1113, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37855199

RESUMEN

Endomyocardial biopsy (EMB) of the right ventricular (RV) septal surface during cardiac catheterization is the standard method to assess cardiac allograft rejection, heart failure, or inflammatory cardiomyopathies. We developed methodology using a three-dimensional (3D) printed phantom to provide proof of concept for using biplane overlay technology for targeted EMB. A standard bioptome and steerable sheath were used to discern feasibility of biopsy for seven regions of the RV septum guided by 3D overlay. This novel biopsy phantom can help train operators in biopsy techniques, and biplane overlay technology has the potential to advance targeted EMB in transplant and cardiomyopathy populations.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Humanos , Resultado del Tratamiento , Cardiomiopatías/diagnóstico por imagen , Biopsia/métodos , Cateterismo Cardíaco , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Miocardio/patología
4.
Artículo en Inglés | MEDLINE | ID: mdl-37740326

RESUMEN

The dislodgement of device during transcatheter procedure is a rare complication and the device can be retrieved by transcatheter techniques in most cases. In case of failed attempts, the surgery may be required and in haemodynamically unstable patients cardiopulmonary bypass (CPB) may be unavoidable. A case of surgical retrieving of patent ductus arteriosus (PDA) occlusion device (OD) from the right pulmonary artery (PA) in a 1050 g baby on CPB was presented. In literature, CPB use in babies weighing under 1 kg has been rarely reported. CPB support was performed securely in our case who is one of the tiniest patients operated on. CPB can be safe enough in the surgical approach of a complication of very low birth weight patient.

5.
Mol Ther Methods Clin Dev ; 30: 122-146, 2023 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-37746245

RESUMEN

Current manufacturing processes for recombinant adeno-associated viruses (rAAVs) have less-than-desired yields and produce significant amounts of empty capsids. The increasing demand and the high cost of goods for rAAV-based gene therapies motivate development of more efficient manufacturing processes. Recently, the US Food and Drug Administration (FDA) approved the first rAAV-based gene therapy product manufactured in the baculovirus expression vector system (BEVS), a technology that demonstrated production of high titers of full capsids. This work presents a first mechanistic model describing the key extracellular and intracellular phenomena occurring during baculovirus infection and rAAV maturation in the BEVS. The model predictions are successfully validated for in-house and literature experimental measurements of the vector genome and of structural and non-structural proteins collected during rAAV manufacturing in the BEVS with the TwoBac and ThreeBac constructs. A model-based analysis of the process is carried out to identify the bottlenecks that limit full capsid formation. Vector genome amplification is found to be the limiting step for rAAV production in Sf9 cells using either the TwoBac or ThreeBac system. In turn, vector genome amplification is hindered by limiting Rep78 levels. Transgene and non-essential baculovirus protein expression in the insect cell during rAAV manufacturing also negatively influences the rAAV production yields.

6.
Pediatr Cardiol ; 2023 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-37243747

RESUMEN

When calculating cardiac index (C.I.) by the Fick method, oxygen consumption (VO2) is often unknown, so assumed values are typically used. This practice introduces a known source of inaccuracy into the calculation. Using a measured VO2 (mVO2) from the CARESCAPE E-sCAiOVX module provides an alternative that may improve accuracy of C.I. calculations. Our aim is to validate this measurement in a general pediatric catheterization population and compare its accuracy with assumed VO2 (aVO2). mVO2 was recorded for all patients undergoing cardiac catheterization with general anesthesia and controlled ventilation during the study period. mVO2 was compared to the reference VO2 (refVO2) determined by the reverse Fick method using cardiac MRI (cMRI) or thermodilution (TD) as a reference standard for measurement of C.I. when available. 193 VO2 measurements were obtained, including 71 with a corresponding cMRI or TD measure of cardiac index for validation. mVO2 demonstrated satisfactory concordance and correlation with the TD- or cMRI-derived refVO2 (ρc = 0.73, r2 = 0.63) with a mean bias of - 3.2% (SD ± 17.3%). Assumed VO2 demonstrated much weaker concordance and correlation with refVO2 (ρc = 0.28, r2 = 0.31) with a mean bias of + 27.5% (SD ± 30.0%). Subgroup analysis of patients < 36 months of age demonstrated that error in mVO2 was not significantly different from that observed in older patients. Many previously reported prediction models for assuming VO2 performed poorly in this younger age range. Measured oxygen consumption using the E-sCAiOVX module is significantly more accurate than assumed VO2 when compared to TD- or cMRI-derived VO2 in a pediatric catheterization lab.

7.
J Cardiovasc Magn Reson ; 24(1): 51, 2022 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-36192743

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) is emerging as an important tool for cardiac allograft assessment. Native T1 mapping may add value in identifying rejection and in assessing graft dysfunction and myocardial fibrosis burden. We hypothesized that CMR native T1 values and features of textural analysis of T1 maps would identify acute rejection, and in a secondary analysis, correlate with markers of graft dysfunction, and with fibrosis percentage from endomyocardial biopsy (EMB). METHODS: Fifty cases with simultaneous EMB, right heart catheterization, and 1.5 T CMR with breath-held T1 mapping via modified Look-Locker inversion recovery (MOLLI) in 8 short-axis slices and subsequent quantification of mean and peak native T1 values, were performed on 24 pediatric subjects. A single mid-ventricular slice was used for image texture analysis using nine gray-level co-occurrence matrix features. Digital quantification of Masson trichrome stained EMB samples established degree of fibrosis. Markers of graft dysfunction, including serum brain natriuretic peptide levels and hemodynamic measurements from echocardiography, catheterization, and CMR were collated. Subjects were divided into three groups based on degree of rejection: acute rejection requiring new therapy, mild rejection requiring increased ongoing therapy, and no rejection with no change in treatment. Statistical analysis included student's t-test and linear regression. RESULTS: Peak and mean T1 values were significantly associated with acute rejection, with a monotonic trend observed with increased grade of rejection. Texture analysis demonstrated greater spatial heterogeneity in T1 values, as demonstrated by energy, entropy, and variance, in cases requiring treatment. Interestingly, 2 subjects who required increased therapy despite low grade EMB results had abnormal peak T1 values. Peak T1 values also correlated with increased BNP, right-sided filling pressures, and capillary wedge pressures. There was no difference in histopathological fibrosis percentage among the 3 groups; histopathological fibrosis did not correlate with T1 values or markers of graft dysfunction. CONCLUSION: In pediatric heart transplant patients, native T1 values identify acute rejection requiring treatment and may identify graft dysfunction. CMR shows promise as an important tool for evaluation of cardiac grafts in children, with T1 imaging outperforming biopsy findings in the assessment of rejection.


Asunto(s)
Trasplante de Corazón , Niño , Fibrosis , Rechazo de Injerto/diagnóstico por imagen , Rechazo de Injerto/patología , Trasplante de Corazón/efectos adversos , Humanos , Imagen por Resonancia Magnética , Miocardio/patología , Péptido Natriurético Encefálico , Valor Predictivo de las Pruebas , Donantes de Tejidos
8.
Crit Care Nurse ; 41(3): e19-e26, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-34061187

RESUMEN

BACKGROUND: The interventional cardiac magnetic resonance imaging suite combines a cardiac catheterization x-ray laboratory with a magnetic resonance imaging suite. At the study institution, interventional cardiac magnetic resonance imaging procedures (ie, magnetic resonance imaging-guided cardiac catheterizations) have been performed under institutional review board-approved research protocols since 2015. Because the workplace incorporates x-ray and magnetic resonance imaging in a highly technical environment, education about the importance of magnet safety is crucial to ensure the safety of patients and staff. OBJECTIVE: To promote magnetic resonance imaging safety and staff preparedness to respond in emergency situations in a specialized interventional cardiac magnetic resonance imaging environment. METHODS: Quarterly in situ evacuation drills with a live volunteer were implemented. A retrospective participant survey using a Likert scale was conducted. Evacuations were timed from the cardiac arrest code alert to safe evacuation or defibrillation if appropriate. RESULTS: Over 4 years, 14 drills were performed. Twenty-nine of 48 participants responded to the survey, a 60% response rate. Most participants agreed or strongly agreed that the drills were a positive experience (90%) and that the drills increased their confidence in their ability to perform in an evacuation scenario (100%). Room evacuation times improved from 71 to 41 seconds. No patient or staff safety events occurred in the interventional cardiac magnetic resonance imaging environment. CONCLUSION: Magnetic resonance imaging-guided cardiac catheterization evacuation drills promote preparedness, ensure patient and staff safety, and improve evacuation time in the interventional cardiac magnetic resonance imaging environment.


Asunto(s)
Cateterismo Cardíaco , Imagen por Resonancia Magnética Intervencional , Corazón , Humanos , Imagen por Resonancia Magnética , Estudios Retrospectivos
9.
J Am Soc Echocardiogr ; 33(10): e1-e48, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-33010859

RESUMEN

The American College of Cardiology (ACC) collaborated with the American Heart Association, American Society of Echocardiography, Heart Rhythm Society, International Society for Adult Congenital Heart Disease, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, and the Society of Pediatric Echocardiography to develop Appropriate Use Criteria (AUC) for multimodality imaging during the follow-up care of patients with congenital heart disease (CHD). This is the first AUC to address cardiac imaging in adult and pediatric patients with established CHD. A number of common patient scenarios (also termed "indications") and associated assumptions and definitions were developed using guidelines, clinical trial data, and expert opinion in the field of CHD.1 The indications relate primarily to evaluation before and after cardiac surgery or catheter-based intervention, and they address routine surveillance as well as evaluation of new-onset signs or symptoms. The writing group developed 324 clinical indications, which they separated into 19 tables according to the type of cardiac lesion. Noninvasive cardiac imaging modalities that could potentially be used for these indications were incorporated into the tables, resulting in a total of 1,035 unique scenarios. These scenarios were presented to a separate, independent panel for rating, with each being scored on a scale of 1 to 9, with 1 to 3 categorized as "Rarely Appropriate," 4 to 6 as "May Be Appropriate," and 7 to 9 as "Appropriate." Forty-four percent of the scenarios were rated as Appropriate, 39% as May Be Appropriate, and 17% as Rarely Appropriate. This AUC document will provide guidance to clinicians in the care of patients with established CHD by identifying the reasonable imaging modality options available for evaluation and surveillance of such patients. It will also serve as an educational and quality improvement tool to identify patterns of care and reduce the number of Rarely Appropriate tests in clinical practice.


Asunto(s)
Cardiología , Cardiopatías Congénitas , Adulto , Cuidados Posteriores , American Heart Association , Angiografía , Niño , Ecocardiografía , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/terapia , Humanos , Espectroscopía de Resonancia Magnética , Imagen Multimodal , Tomografía Computarizada por Rayos X , Estados Unidos
10.
Cardiol Young ; 30(6): 852-859, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32456723

RESUMEN

BACKGROUND: Monitoring for acute allograft rejection improves outcomes after cardiac transplantation. Endomyocardial biopsy is the gold standard test defining rejection, but carries risk and has limitations. Cardiac magnetic resonance T2 mapping may be able to predict rejection in adults, but has not been studied in children. Our aim was to evaluate T2 mapping in identifying paediatric cardiac transplant patients with acute rejection. METHODS: Eleven paediatric transplant patients presenting 18 times were prospectively enrolled for non-contrast cardiac magnetic resonance at 1.5 T followed by endomyocardial biopsy. Imaging included volumetry, flow, and T2 mapping. Regions of interest were manually selected on the T2 maps using the middle-third technique in the left ventricular septal and lateral wall in a short-axis and four-chamber slice. Mean and maximum T2 values were compared with Student's t-tests analysis. RESULTS: Five cases of acute rejection were identified in three patients, including two cases of grade 2R on biopsy and three cases of negative biopsy treated for clinical symptoms attributed to rejection (new arrhythmia, decreased exercise capacity). A monotonic trend between increasing T2 values and higher biopsy grades was observed: grade 0R T2 53.4 ± 3 ms, grade 1R T2 54.5 ms ± 3 ms, grade 2R T2 61.3 ± 1 ms. The five rejection cases had significantly higher mean T2 values compared to cases without rejection (58.3 ± 4 ms versus 53 ± 2 ms, p = 0.001). CONCLUSIONS: Cardiac magnetic resonance with quantitative T2 mapping may offer a non-invasive method for screening paediatric cardiac transplant patients for acute allograft rejection. More data are needed to understand the relationship between T2 and rejection in children.


Asunto(s)
Rechazo de Injerto/diagnóstico por imagen , Trasplante de Corazón/efectos adversos , Imagen por Resonancia Cinemagnética , Miocardio/patología , Enfermedad Aguda , Adolescente , Niño , Preescolar , Femenino , Rechazo de Injerto/patología , Humanos , Modelos Logísticos , Masculino , Valor Predictivo de las Pruebas , Trasplante Homólogo , Resultado del Tratamiento , Estados Unidos
12.
Int J Artif Organs ; 43(9): 625-628, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31996067

RESUMEN

Utilization of Berlin Excor as a pediatric bridge to transplantation device continues to increase. Thromboembolic complications continue to be an important morbidity related to ventricular assist devices. Obstructions to the device cannulae are rare but potentially life-threatening complications of ventricular assist devices, but inflow cannula obstruction is hitherto unreported. We present a case of a 4-year-old supported with Berlin BiVAD who demonstrated acute decompensation related to thrombus within the left atrial cannula. We describe the diagnosis, intervention, as well as novel rescue using existing cannulae for extracorporeal membrane oxygenation support.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca/terapia , Trasplante de Corazón , Corazón Auxiliar/efectos adversos , Tromboembolia/etiología , Tromboembolia/terapia , Cánula , Cateterismo , Preescolar , Femenino , Insuficiencia Cardíaca/fisiopatología , Humanos
13.
Catheter Cardiovasc Interv ; 94(3): 399-408, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31062506

RESUMEN

OBJECTIVES: To determine whether X-ray fused with MRI (XFM) is beneficial for select transcatheter congenital heart disease interventions. BACKGROUND: Complex transcatheter interventions often require three-dimensional (3D) soft tissue imaging guidance. Fusion imaging with live X-ray fluoroscopy can potentially improve and simplify procedures. METHODS: Patients referred for select congenital heart disease interventions were prospectively enrolled. Cardiac MRI data was overlaid on live fluoroscopy for procedural guidance. Likert scale operator assessments of value were recorded. Fluoroscopy time, radiation exposure, contrast dose, and procedure time were compared to matched cases from our institutional experience. RESULTS: Forty-six patients were enrolled. Pre-catheterization, same day cardiac MRI findings indicated intervention should be deferred in nine patients. XFM-guided cardiac catheterization was performed in 37 (median age 8.7 years [0.5-63 years]; median weight 28 kg [5.6-110 kg]) with the following prespecified indications: pulmonary artery (PA) stenosis (n = 13), aortic coarctation (n = 12), conduit stenosis/insufficiency (n = 9), and ventricular septal defect (n = 3). Diagnostic catheterization showed intervention was not indicated in 12 additional cases. XFM-guided intervention was performed in the remaining 25. Fluoroscopy time was shorter for XFM-guided intervention cases compared to matched controls. There was no significant difference in radiation dose area product, contrast volume, or procedure time. Operator Likert scores indicated XFM provided useful soft tissue guidance in all cases and was never misleading. CONCLUSIONS: XFM provides operators with meaningful three-dimensional soft tissue data and reduces fluoroscopy time in select congenital heart disease interventions.


Asunto(s)
Cateterismo Cardíaco , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/terapia , Imagen por Resonancia Magnética , Radiografía Intervencional , Adolescente , Adulto , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Toma de Decisiones Clínicas , Medios de Contraste/administración & dosificación , Femenino , Fluoroscopía , Humanos , Lactante , Imagen por Resonancia Magnética/efectos adversos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Selección de Paciente , Valor Predictivo de las Pruebas , Estudios Prospectivos , Dosis de Radiación , Exposición a la Radiación , Radiografía Intervencional/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Adulto Joven
14.
Paediatr Anaesth ; 29(1): 8-15, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30375141

RESUMEN

Cardiac catheterization is an integral part of medical management for pediatric patients with congenital heart disease. Owing to age and lack of cooperation in children who need this procedure, general anesthesia is typically required. These patients have increased anesthesia risk secondary to cardiac pathology. Furthermore, multiple catheterization procedures result in exposure to harmful ionizing radiation. Magnetic resonance imaging-guided right-heart catheterization offers decreased radiation exposure and diagnostic imaging benefits over traditional fluoroscopy but potentially increases anesthetic complexity and risk. We describe our early experience with anesthetic techniques and challenges for pediatric magnetic resonance imaging-guided right-heart catheterization.


Asunto(s)
Anestesia General/métodos , Cateterismo Cardíaco/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Adolescente , Procedimientos Quirúrgicos Cardíacos/métodos , Niño , Preescolar , Femenino , Fluoroscopía , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Humanos , Masculino , Adulto Joven
15.
J Am Heart Assoc ; 7(5)2018 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-29490973

RESUMEN

BACKGROUND: Cardiac catheterization is the gold standard for assessment and follow-up of patients with pulmonary hypertension (PH). To date, there are limited data about the factors that influence the risk of catastrophic adverse events after catheterization in this population. METHODS AND RESULTS: A retrospective multicenter cohort study was performed to measure risk of catastrophic adverse outcomes after catheterization in children and young adults with PH and identify risk factors for these outcomes. All catheterizations in children and young adults, aged 0 to 21 years, with PH at hospitals submitting data to the IMPACT (Improving Adult and Congenital Treatment) registry between January 1, 2011, and December 31, 2015, were studied. Using mixed-effects multivariable regression, we assessed the association between prespecified subject-, procedure-, and center-level covariates and the risk of death, cardiac arrest, or mechanical circulatory support during or after cardiac catheterization. A total of 8111 procedures performed in 7729 subjects at 77 centers were studied. The observed risk of the composite outcome was 1.4%, and the risk of death before discharge was 5.2%. Catheterization in prematurely born neonates and nonpremature infants was associated with increased risk of catastrophic adverse event, as was precatheterization treatment with inotropes and lower systemic arterial saturation. Secondary analyses demonstrated the following: (1) increasing volumes of catheterization in patients with PH were associated with reduced risk of composite outcome (odds ratio, 0.8 per 10 procedures; P=0.002) and (2) increasing pulmonary vascular resistance and pulmonary artery pressures were associated with increased risk (P<0.0001 for both). CONCLUSIONS: Young patients with PH are a high-risk population for diagnostic and interventional cardiac catheterization. Hospital experience with PH is associated with reduced risk, independent of total catheterization case volume.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Paro Cardíaco/etiología , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/terapia , Arteria Pulmonar/fisiopatología , Adolescente , Factores de Edad , Presión Arterial , Cateterismo Cardíaco/mortalidad , Niño , Preescolar , Femenino , Paro Cardíaco/mortalidad , Paro Cardíaco/fisiopatología , Paro Cardíaco/terapia , Corazón Auxiliar , Mortalidad Hospitalaria , Humanos , Hipertensión Pulmonar/mortalidad , Hipertensión Pulmonar/fisiopatología , Lactante , Recién Nacido , Masculino , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología , Resistencia Vascular , Adulto Joven
16.
J Cardiovasc Magn Reson ; 19(1): 65, 2017 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-28874164

RESUMEN

BACKGROUND: Children with heart disease may require repeated X-Ray cardiac catheterization procedures, are more radiosensitive, and more likely to survive to experience oncologic risks of medical radiation. Cardiovascular magnetic resonance (CMR) is radiation-free and offers information about structure, function, and perfusion but not hemodynamics. We intend to perform complete radiation-free diagnostic right heart catheterization entirely using CMR fluoroscopy guidance in an unselected cohort of pediatric patients; we report the feasibility and safety. METHODS: We performed 50 CMR fluoroscopy guided comprehensive transfemoral right heart catheterizations in 39 pediatric (12.7 ± 4.7 years) subjects referred for clinically indicated cardiac catheterization. CMR guided catheterizations were assessed by completion (success/failure), procedure time, and safety events (catheterization, anesthesia). Pre and post CMR body temperature was recorded. Concurrent invasive hemodynamic and diagnostic CMR data were collected. RESULTS: During a twenty-two month period (3/2015 - 12/2016), enrolled subjects had the following clinical indications: post-heart transplant 33%, shunt 28%, pulmonary hypertension 18%, cardiomyopathy 15%, valvular heart disease 3%, and other 3%. Radiation-free CMR guided right heart catheterization attempts were all successful using passive catheters. In two subjects with septal defects, right and left heart catheterization were performed. There were no complications. One subject had six such procedures. Most subjects (51%) had undergone multiple (5.5 ± 5) previous X-Ray cardiac catheterizations. Retained thoracic surgical or transcatheter implants (36%) did not preclude successful CMR fluoroscopy heart catheterization. During the procedure, two subjects were receiving vasopressor infusions at baseline because of poor cardiac function, and in ten procedures, multiple hemodynamic conditions were tested. CONCLUSIONS: Comprehensive CMR fluoroscopy guided right heart catheterization was feasible and safe in this small cohort of pediatric subjects. This includes subjects with previous metallic implants, those requiring continuous vasopressor medication infusions, and those requiring pharmacologic provocation. Children requiring multiple, serial X-Ray cardiac catheterizations may benefit most from radiation sparing. This is a step toward wholly CMR guided diagnostic (right and left heart) cardiac catheterization and future CMR guided cardiac intervention. TRIAL REGISTRATION: ClinicalTrials.gov NCT02739087 registered February 17, 2016.


Asunto(s)
Cateterismo Cardíaco/métodos , Cardiopatías/diagnóstico , Imagen por Resonancia Magnética Intervencional , Exposición a la Radiación/prevención & control , Adolescente , Factores de Edad , Niño , Estudios de Factibilidad , Femenino , Cardiopatías/fisiopatología , Hemodinámica , Humanos , Masculino , Valor Predictivo de las Pruebas , Exposición a la Radiación/efectos adversos , Factores de Tiempo
17.
Am Heart J ; 192: 85-97, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28938967

RESUMEN

Concern for device erosion following transcatheter treatment of atrial septal defects (TC-ASD) led in 2012 to a United States Food and Drug Administration panel review and changes in the instructions for use of the Amplatzer Septal Occluder (ASO) device. No studies have assessed the effect of these changes on real-world practice. To this end a multicenter observational study was performed to evaluate trends in the treatment of ASD. METHODS: A retrospective observational study was performed using data from the Pediatric Health Information Systems database of all patients with isolated ASD undergoing either TC-ASD or operative ASD closure (O-ASD) from January 1, 2007, to September 30, 2015, hypothesizing that the propensity to pursue O-ASD increased beginning in 2013. RESULTS: A total of 6,392 cases from 39 centers underwent ASD closure (82% TC-ASD). Adjusting for patient factors, between 2007 and 2012, the probability of pursuing O-ASD decreased (odds ratio [OR] 0.95 per year, P = .03). This trend reversed beginning in 2013, with the probability of O-ASD increasing annually (OR 1.21, P = .006). There was significant between-hospital variation in the choice between TC-ASD and O-ASD (median OR 2.79, P < .0001). The age of patients undergoing ASD closure (regardless of method) decreased over the study period (P = .04). Cost of O-ASD increased over the study period, whereas cost of TC-ASD and length of stay for both O-ASD and TC-ASD was unchanged. CONCLUSIONS: Although TC-ASD remains the predominant method of ASD closure, the propensity to pursue O-ASD has increased significantly following changes in instructions for use for ASO. Further research is necessary to determine what effect this has on outcomes and resource utilization.


Asunto(s)
Adhesión a Directriz , Sistemas de Información en Salud , Defectos del Tabique Interatrial/cirugía , Puntaje de Propensión , Dispositivo Oclusor Septal , Adolescente , Cateterismo Cardíaco/métodos , Niño , Preescolar , Ecocardiografía Transesofágica , Femenino , Defectos del Tabique Interatrial/diagnóstico , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento , Estados Unidos , United States Food and Drug Administration
18.
Pediatr Cardiol ; 37(7): 1380-91, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27377524

RESUMEN

Treatment of pulmonary atresia with major aortopulmonary collaterals (PA MAPCAs) remains a challenge. Despite variations in surgical technique, contemporary strategies all include initial intervention in the first year of life. However, a subset of patients presents later in life, and contemporary outcomes of this group have not been reported previously. We performed a retrospective case series of consecutive cases of PA MAPCAs who were seen at our center between January 2001 and February 2016, who had not undergone surgery before the age of 1 year. We describe their presenting characteristics, operative and transcatheter interventions, and outcomes. A total of eight cases were identified from 76 children with PA MAPCAs treated over the study period. Median age at presentation was 5.9 years. Seventy-five percent had confluent pulmonary arteries with a median Nakata index of 113 mm(2)/m(2). Operative intervention was performed in 5/6 cases. Two are awaiting intervention. The combination of operative and transcatheter interventions allowed for ventricular septal defect closure in 60 % of cases, all of whom had subsystemic right ventricular pressures. Operative intervention is possible in some older cases with PA and MAPCAs. Though multiple operations and transcatheter therapies are necessary, some can achieve operative correction of serial circulation with tolerable physiology. Subjects with ventricular hypoplasia and those without confluent pulmonary arteries are more challenging.


Asunto(s)
Atresia Pulmonar , Preescolar , Circulación Colateral , Defectos del Tabique Interventricular , Humanos , Arteria Pulmonar , Estudios Retrospectivos
20.
Congenit Heart Dis ; 11(1): 39-44, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26477998

RESUMEN

BACKGROUND: Shunt or conduit thrombosis in a single ventricle circuit is a life-threatening complication that requires prompt treatment to rapidly restore shunt/conduit patency. Transcatheter interventions represent an attractive alternative to systemic thrombolysis or open surgical procedures. We report our center's experience with catheter-based approaches in patients with palliated single ventricle who present with shunt/conduit thrombosis. METHODS: A retrospective review was performed of all patients with palliated single ventricle physiology who were diagnosed over a 5-year period with shunt/conduit thrombosis and received catheter-based interventions. Patients were followed up to hospital discharge. RESULTS: Thirteen patients were identified that were diagnosed with thrombosis of a modified Blalock-Taussig shunt (five patients), bidirectional cavopulmonary shunt (one patient), and total cavopulmonary pathway (seven patients). Shunt/conduit thrombosis occurred both early and late after palliation surgery. Catheter-based interventions included balloon angioplasty (one patient), stent implantation (12 patients), and mechanical thrombectomy (one patient). Thrombophilia was identified in seven patients. Technical and clinical success with restoration of normal shunt flow and improvement in clinical status was achieved in 12 patients. Reversible procedure-related complications occurred in three patients with no significant sequelae. CONCLUSIONS: Our experience suggests that percutaneous catheter-based interventions are safe and effective in managing shunt/conduit thrombosis in infants and children with palliated single ventricle circulation.


Asunto(s)
Angioplastia Coronaria con Balón , Procedimiento de Blalock-Taussing/efectos adversos , Cateterismo Cardíaco , Puente Cardíaco Derecho/efectos adversos , Cardiopatías Congénitas/cirugía , Ventrículos Cardíacos/cirugía , Trombectomía , Trombosis/terapia , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Femenino , Cardiopatías Congénitas/diagnóstico , Ventrículos Cardíacos/anomalías , Humanos , Masculino , Cuidados Paliativos , Estudios Retrospectivos , Stents , Trombectomía/efectos adversos , Trombosis/diagnóstico , Trombosis/etiología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA