Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
JACC Adv ; 3(2): 100817, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38939388

RESUMEN

Background: Sex-based differences in clinical outcomes among patients with stroke related to left ventricular assist devices (LVADs) are not well described. Objectives: In this study, the authors examined differences in clinical characteristics and outcomes in men and women who had a stroke during LVAD hospitalization. Methods: The National Inpatient Sample from 2010 and 2019 was used to identify patients with stroke during LVAD hospitalization. Outcomes of interest include inpatient mortality and clinical complications among men vs women. Weighted logistic regression was used to determine the association of sex and outcomes. Adjustments were made for age and the Elixhauser comorbidity index. Results: In total, 35,820 patients underwent LVAD implantation (77% men), and 6.12% (n = 2,192) of patients experienced stroke. Women who had stroke were younger than men who had stroke (mean age in women was 51 years vs men 59 years, P < 0.001). Men with strokes had a higher burden of comorbidities than women. While there were no differences in the odds of ischemic stroke, women had higher odds of hemorrhagic stroke compared to men (OR: 1.49 [95% CI: 1.02-2.18]). Mortality in patients with LVAD who had stroke was significantly higher than in those without stroke. Between 2010 and 2019, stroke rates significantly increased among men, while the trend remained variable among women. Conclusions: In this national cohort, men had a higher comorbidity burden and had worsening stroke trends over the last decade compared to women. Women had fewer LVAD implants and a higher incidence of hemorrhagic stroke. Understanding the factors that contribute to sex-related outcome disparities among LVAD stroke patients is crucial in addressing these diverging trends.

2.
Clin Transplant ; 38(2): e15249, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38369810

RESUMEN

BACKGROUND: Desensitization is one of the strategies to reduce antibodies and facilitate heart transplantation in highly sensitized patients. We describe our center's desensitization experience with combination of plasma cell (PC) depletion therapy (with proteasome inhibitor or daratumumab) and costimulation blockade (with belatacept). METHODS: We reviewed five highly sensitized patients who underwent desensitization therapy with plasma cell depletion and costimulation blockade. We evaluated the response to therapy by measuring the changes in cPRA, average MFI, and number of positive beads > 5000MFI. RESULTS: Five patients, mean age of 56 (37-66) years with average cPRA of 98% at 5000 MFI underwent desensitization therapy. After desensitization, mean cPRA decreased from 98% to 70% (p = .09), average number of beads > 5000 MFI decreased from 59 to 37 (p = .15), and average MFI of beads > 5000 MFI decreased from 16713 to 13074 (p = .26). CONCLUSION: Combined PC depletion and CoB could be a reasonable strategy for sustained reduction in antibodies in highly sensitized patients being listed for heart transplantation.


Asunto(s)
Trasplante de Corazón , Células Plasmáticas , Humanos , Persona de Mediana Edad , Abatacept/uso terapéutico , Abatacept/farmacología , Desensibilización Inmunológica , Rechazo de Injerto/etiología , Rechazo de Injerto/prevención & control , Antígenos HLA , Isoanticuerpos , Inhibidores de Proteasoma , Adulto , Anciano
3.
Artif Organs ; 48(5): 536-542, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38189564

RESUMEN

BACKGROUND: Pump exchange is an established strategy to treat LVAD-related complications such as thrombosis, infection, and driveline failure. Pump upgrades with an exchange to newer generation devices are being performed to the advantage of the patient on long-term support. The safety and efficacy of a repeat LVAD exchange with a concomitant upgrade to a third-generation pump have not been reported. METHODS: We performed a retrospective analysis of all consecutive patients who underwent a repeat LVAD device exchange and upgrade to HeartMate III (HMIII) at Houston Methodist Hospital between December 2018 and December 2020. RESULTS: Five patients underwent exchange and upgrade to HMIII within the specified timeframe. Four patients had already had two prior exchanges (all HMII to HMII), and one patient had one prior exchange (HVAD to HVAD). In all cases, implantation was performed as destination therapy. The surgical exchange was performed via redo median sternotomy on full cardiopulmonary bypass. No unplanned redo surgery of the device component was required. In-hospital mortality was 20% in this very high-risk population. At 1-, 3-, and 6-month follow-up, all discharged patients were on HMIII support, with no major LVAD-related adverse events reported. CONCLUSION: We report the feasibility and safety of a repeat pump exchange with an upgrade to HMIII in a high-volume center. The decision for medical therapy versus surgical exchange has to be tailored to individual cases based on risk factors and clinical stability but in expert hands, even a re-redo surgical approach grants options for good medium-term outcomes.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Humanos , Insuficiencia Cardíaca/cirugía , Estudios Retrospectivos , Corazón Auxiliar/efectos adversos , Hospitales
4.
Patient Educ Couns ; 122: 108157, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38290171

RESUMEN

BACKGROUND: Personalized risk (PR) estimates may enhance clinical decision making and risk communication by providing individualized estimates of patient outcomes. We explored stakeholder attitudes toward the utility, acceptability, usefulness and best-practices for integrating PR estimates into patient education and decision making about Left Ventricular Assist Device (LVAD). METHODS AND RESULTS: As part of a 5-year multi-institutional AHRQ project, we conducted 40 interviews with stakeholders (physicians, nurse coordinators, patients, and caregivers), analyzed using Thematic Content Analysis. All stakeholder groups voiced positive views towards integrating PR in decision making. Patients, caregivers and coordinators emphasized that PR can help to better understand a patient's condition and risks, prepare mentally and logistically for likely outcomes, and meaningfully engage in decision making. Physicians felt it can improve their decision making by enhancing insight into outcomes, enhance tailored pre-emptive care, increase confidence in decisions, and reduce bias and subjectivity. All stakeholder groups also raised concerns about accuracy, representativeness and relevance of algorithms; predictive uncertainty; utility in relation to physician's expertise; potential negative reactions among patients; and overreliance. CONCLUSION: Stakeholders are optimistic about integrating PR into clinical decision making, but acceptability depends on prospectively demonstrating accuracy, relevance and evidence that benefits of PR outweigh potential negative impacts on decision making quality.


Asunto(s)
Corazón Auxiliar , Médicos , Humanos , Toma de Decisiones , Educación del Paciente como Asunto , Actitud
5.
ASAIO J ; 70(6): 469-476, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38181411

RESUMEN

We explored whether women undergo continuous-flow left ventricular assist device (CF-LVAD) implantation in later stages of heart failure (HF) than men, evidenced by worse preoperative right HF (RHF). We also compared two propensity models with and without preoperative RHF to assess its effect on outcomes. INTERMACS was queried from July 2008 to December 2017. Propensity model 1 matched men and women on age ≥50 years, HF etiology, body surface area, INTERMACS class, comorbidities, device strategy, temporary mechanical circulatory support, and device type. Model 2 included these variables plus LV end-diastolic diameter, right atrial pressure/pulmonary capillary wedge pressure, pulmonary artery pulsatility index, and right ventricular ejection fraction. The primary outcome was all-cause mortality. Secondary outcomes comprise RHF, rehospitalization, renal dysfunction, stroke, and device malfunction. In model 1, characteristics were comparable between 3,195 women and 3,195 men, except women more often had preoperative RHF and postoperative right VAD support and had worse 1 year and overall survival. In model 2, after propensity matching for additional risk factors for preoperative RHF, 1,119 women and 1,119 men had comparable post-LVAD implant RVAD use and survival. These findings suggest that women present more often with biventricular failure and after implantation have higher RHF and mortality rates.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Corazón Auxiliar/efectos adversos , Femenino , Masculino , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/fisiopatología , Persona de Mediana Edad , Anciano , Factores Sexuales , Estudios Retrospectivos , Disfunción Ventricular Derecha/fisiopatología , Disfunción Ventricular Derecha/etiología
6.
Artif Organs ; 48(4): 375-385, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37962282

RESUMEN

BACKGROUND: Hemocompatibility-related adverse events (HRAE) occur commonly in patients with left ventricular assist devices (LVADs) and add to morbidity and mortality. It is unclear whether the outflow graft orientation can impact flow conditions leading to HRAE. This study presents a simulation-based approach using exact patient anatomy from medical images to investigate the influence of outflow cannula orientation in modulating flow conditions leading to HRAEs. METHODS: A 3D model of a proximal aorta and outflow graft was reconstructed from a computed tomography (CT) scan of an LVAD patient and virtually modified to model multiple cannula orientations (n = 10) by varying polar (cranio-caudal) (n = 5) and off-set (anterior-posterior) (n = 2) angles. Time-dependent computational flow simulations were then performed for each anatomical orientation. Qualitative and quantitative hemodynamics metrics of thrombogenicity including time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), endothelial cell platelet activation potential (ECAP), particle residence time (PRT), and platelet activation potential (PLAP) were analyzed. RESULTS: Within the simulations performed, endothelial cell activation potential (ECAP) and particle residence time (PRT) were found to be lowest with a polar angle of 85°, regardless of offset angle. However, polar angles that produced parameters at levels least associated with thrombosis varied when the offset angle was changed from 0° to 12°. For offset angles of 0° and 12° respectively, flow shear was lowest at 65° and 75°, time averaged wall shear stress (TAWSS) was highest at 85° and 35°, and platelet activation potential (PLAP) was lowest at 65° and 45°. CONCLUSION: This study suggests that computational fluid dynamic modeling based on patient-specific anatomy can be a powerful analytical tool when identifying optimal positioning of an LVAD. Contrary to previous work, our findings suggest that there may be an "ideal" outflow cannula for each individual patient based on a CFD-based hemocompatibility profile.


Asunto(s)
Corazón Auxiliar , Trombosis , Humanos , Corazón Auxiliar/efectos adversos , Modelos Cardiovasculares , Hidrodinámica , Aorta/fisiología , Trombosis/etiología , Hemodinámica/fisiología
7.
Infect Control Hosp Epidemiol ; 45(3): 374-376, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37946375

RESUMEN

Infections from prolonged use of axillary intra-aortic balloon pumps (IABPs) have not been well studied. Bloodstream infection (BSI) occurred in 13% of our patients; however, no difference in outcome was noted between those with BSI and those without. Further studies regarding protocol developments that minimize BSI risk are needed.


Asunto(s)
Contrapulsador Intraaórtico , Sepsis , Humanos , Contrapulsador Intraaórtico/efectos adversos , Contrapulsador Intraaórtico/métodos , Proyectos de Investigación , Sepsis/etiología
8.
Front Cardiovasc Med ; 10: 1248300, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37692033

RESUMEN

Heart failure remains a significant cause of mortality in the United States and around the world. While organ transplantation is acknowledged as the gold standard treatment for end stage heart failure, supply is limited, and many patients are treated with left ventricular assist devices (LVADs). LVADs extend and improve patients' lives, but they are not without their own complications, particularly the hemocompatibility related adverse events (HRAE) including stroke, bleeding and pump thrombosis. Mainstream imaging techniques currently in use to assess appropriate device function and troubleshoot complications, such as echocardiography and cardiac computed tomography, provide some insight but do not provide a holistic understanding of pump induced flow alterations that leads to HRAEs. In contrast, there are technologies restricted to the benchtop-such as computational fluid dynamics and mock circulatory loops paired with methods like particle image velocimetry-that can assess flow metrics but have not been optimized for clinical care. In this review, we outline the potential role and current limitations of converging available technologies to produce novel imaging techniques, and the potential utility in evaluating hemodynamic flow to determine whether LVAD patients may be at higher risk of HRAEs. This addition to diagnostic and monitoring capabilities could improve prevention and treatment of LVAD-induced complications in heart failure patients.

9.
Int J Artif Organs ; 46(4): 226-234, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36895175

RESUMEN

We sought to evaluate whether differences in left ventricular assist device (LVAD) canula alignment are associated with stroke. There is a paucity of clinical data on contribution of LVAD canulae alignment to strokes. We conducted a retrospective analysis of patients who underwent LVAD implantation at Houston Methodist hospital from 2011 to 2016 and included those who had undergone cardiac computed tomography (CT) with contrast. LVAD graft alignment using X-ray, echocardiography, and cardiac CT was evaluated. The primary outcome was stroke within 1 year of LVAD implantation. Of the 101 patients that underwent LVAD Implantation and cardiac CT scan during the study period, 78 met inclusion criteria. The primary outcome occurred in 12 (15.4%) patients with a median time to stroke of 77 days (interquartile range: 42-132 days). Of these, 10 patients had an ischemic and two had hemorrhagic strokes. The predominant device type was Heart Mate II (94.8%). Patients with LVAD outflow cannula to aortic angle lesser than 37.5° and those with outflow graft diameter of anastomosis less than 1.5 cm (assessed by cardiac CT) had significantly higher stroke risk (p < 0.001 and p = 0.01 respectively). In HMII patients, a lower LVAD speed at the time of CT scan was associated with stroke. Further studies are needed to identify optimal outflow graft configuration to mitigate stroke risk.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular , Humanos , Estudios Retrospectivos , Cánula , Ecocardiografía , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Corazón Auxiliar/efectos adversos
10.
Front Cardiovasc Med ; 10: 994431, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36844719

RESUMEN

Background: Aortic regurgitation (AR) occurs commonly in patients with continuous-flow left ventricular assist devices (LVAD). No gold standard is available to assess AR severity in this setting. Aim of this study was to create a patient-specific model of AR-LVAD with tailored AR flow assessed by Doppler echocardiography. Methods: An echo-compatible flow loop incorporating a 3D printed left heart of a Heart Mate II (HMII) recipient with known significant AR was created. Forward flow and LVAD flow at different LVAD speed were directly measured and AR regurgitant volume (RegVol) obtained by subtraction. Doppler parameters of AR were simultaneously measured at each LVAD speed. Results: We reproduced hemodynamics in a LVAD recipient with AR. AR in the model replicated accurately the AR in the index patient by comparable Color Doppler assessment. Forward flow increased from 4.09 to 5.61 L/min with LVAD speed increasing from 8,800 to 11,000 RPM while RegVol increased by 0.5 L/min (2.01 to 2.5 L/min). Conclusions: Our circulatory flow loop was able to accurately replicate AR severity and flow hemodynamics in an LVAD recipient. This model can be reliably used to study echo parameters and aid clinical management of patients with LVAD.

11.
Eur J Nucl Med Mol Imaging ; 50(4): 1103-1110, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36474124

RESUMEN

PURPOSE: We evaluated whether serum beta-hydroxybutyrate (BHB) can identify adequate suppression of the left ventricle (LV) among patients undergoing [18F]-fluorodeoxyglucose positron emission tomography ([18F]-FDG PET) for cardiac inflammatory/infectious studies. METHODS: Consecutive patients who underwent [18F]-FDG PET imaging were included. Serum BHB levels were measured in all patients on the day of imaging prior to injecting [18F]-FDG. Myocardial [18F]-FDG suppression was defined if [18F]-FDG uptake in the walls of myocardium, measured using standardized uptake values (SUV), was lower than the blood pool. The optimal threshold of BHB to identify myocardial suppression was based on receiver operating characteristics (ROC) in a random 30% sample of the study population (derivation cohort) and tested in the remaining 70% of sample (validation cohort). RESULTS: A total of 256 images from 220 patients were included. Patients with sufficient LV suppression had significantly higher BHB levels compared to those with non-suppressed myocardium (median (IQR) BHB 0.6 (0.3-0.8) vs. 0.2 (0.2-0.3) mmol/l, p < 0.001, respectively). BHB level ≥ 0.335 mmol/l had a sensitivity of 84.90% and a specificity of 92.60% to identify adequate LV suppression in the validation cohort. All patients (100%) with BHB ≥ 0.41 mmol/l had adequate myocardial suppression compared to 29.63% of patients with BHB ≤ 0.20 mmol/l. CONCLUSION: Serum BHB level can be used at the point of care to identify sufficient LV suppression in patients undergoing [18F]-FDG PET cardiac inflammatory/infectious studies. Central illustration (image to the right) shows representative cases of patient images and BHB and, in the image to the left, shows the sensitivity and specificity to identify left myocardial suppression using BHB in validation group.


Asunto(s)
Fluorodesoxiglucosa F18 , Cardiopatías , Humanos , Ácido 3-Hidroxibutírico , Radiofármacos , Miocardio , Tomografía de Emisión de Positrones/métodos , Glucosa
12.
Methodist Debakey Cardiovasc J ; 19(1): 92-95, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38161506

RESUMEN

A 75-year-old patient was incidentally found to have an intracardiac mass by echocardiography. Subsequent cardiac magnetic resonance imaging and cardiac positron emission tomography confirmed a large and possibly malignant mass extending from the right atrium into the coronary sinus. The patient underwent an intracardiac echocardiography guided biopsy, which revealed diffuse B-cell lymphoma, and is currently undergoing rituximab, etoposide, vincristine, cyclophosphamide, and doxorubicin (R-EPOCH)-based chemotherapy.


Asunto(s)
Linfoma de Células B Grandes Difuso , Humanos , Anciano , Linfoma de Células B Grandes Difuso/diagnóstico por imagen , Linfoma de Células B Grandes Difuso/tratamiento farmacológico , Linfoma de Células B Grandes Difuso/patología , Rituximab/uso terapéutico , Ciclofosfamida/uso terapéutico , Vincristina/uso terapéutico , Prednisona/uso terapéutico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Doxorrubicina/uso terapéutico , Tomografía de Emisión de Positrones , Ecocardiografía
13.
Methodist Debakey Cardiovasc J ; 18(4): 89-93, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36188096

RESUMEN

Spontaneous coronary sinus thrombosis (CST) is an extremely rare occurrence. Most cases are iatrogenic and related to right heart instrumentation, due to either central line placement or electrophysiology procedures such as pacemaker insertion that causes direct damage to the endothelial lining. The course can be insidious and may result in a fatal outcome. Diagnosis of CST is challenging, and the syndrome often goes unrecognized. However, in the current era of multimodality imaging, it is possible that this condition will be recognized in more patients. Herein, we present a patient with spontaneous coronary sinus thrombosis that was diagnosed using multimodality imaging and thereafter successfully managed.


Asunto(s)
Seno Coronario , Trombosis Coronaria , Anomalías de los Vasos Coronarios , Trombosis de los Senos Intracraneales , Cateterismo Cardíaco , Seno Coronario/diagnóstico por imagen , Trombosis Coronaria/complicaciones , Trombosis Coronaria/diagnóstico por imagen , Anomalías de los Vasos Coronarios/complicaciones , Humanos , Trombosis de los Senos Intracraneales/complicaciones
14.
J Am Heart Assoc ; 11(18): e025903, 2022 09 20.
Artículo en Inglés | MEDLINE | ID: mdl-36073626

RESUMEN

Background Despite improvements in the management and prevention of stroke, increasing hospitalizations for stroke and stagnant mortality rates have been described in young adults. However, there is a paucity of contemporary national mortality estimates in young adults. Methods and Results Trends in mortality related to stroke in young adults (aged 25-64 years) were assessed using the Centers for Disease Control and Prevention Wide-Ranging Online Data for Epidemiologic Research database. Age-adjusted mortality rates per 100 000 people with associated annual percentage change were calculated. Joinpoint regression was used to assess the trends in the overall sample and different demographic (sex, race and ethnicity, and age) and geographical (state, urban-rural, and regional) subgroups. Between 1999 and 2019, a total of 566 916 stroke-related deaths occurred among young adults. After the initial decline in mortality in the overall population, age-adjusted mortality rate increased from 2013 to 2019 with an associated annual percentage change of 1.5 (95% CI, 1.1-2.0). Mortality rates were higher in men versus women and in non-Hispanic Black people versus individuals of other races and ethnicities. Non-Hispanic American Indian or Alaskan Native people had a marked increase in stroke-related mortality (annual percentage change 2010-2019: 3.3). Furthermore, rural (nonmetropolitan) counties experienced the greatest increase in mortality (annual percentage change 2012-2019: 3.1) compared with urban (metropolitan) counties. Conclusions Following the initial decline in stroke-related mortality, young adults have experienced increasing mortality rates from 2013 to 2019, with considerable differences across demographic groups and regions.


Asunto(s)
Etnicidad , Accidente Cerebrovascular , Centers for Disease Control and Prevention, U.S. , Femenino , Humanos , Masculino , Mortalidad , Población Rural , Estados Unidos/epidemiología , Adulto Joven
15.
Int J Artif Organs ; 45(11): 911-918, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35941752

RESUMEN

OBJECTIVES: We sought to examine the efficacy and safety of adding fibrinogen-guided low-dose multi-day Alteplase™ tissue plasminogen activator (tPA) in the management of intravascular hemolysis (IVH) in patients with the HeartMate II (HM-II) continuous flow (CF) left ventricular assist device (LVAD) who failed to achieve IVH resolution with conventional augmented anticoagulation (AAC). BACKGROUND: IVH in patients with LVAD is often treated with AAC, failing which pump exchange is considered. We hypothesized that a trial of low-dose tPA after failed AAC therapy could resolve IVH and prevent pump exchange in some patients. METHODS: We performed a retrospective study of 31 HM-II CF LVAD patients admitted to our center from January 2015 to January 2020 for IVH management who received tPA following failed AAC. Primary 6-month outcomes included successful IVH resolution, unsuccessful IVH resolution requiring pump exchange, gastrointestinal bleeding, ischemic and hemorrhagic cerebrovascular accident (CVA), and death. RESULTS: Thirty-one patients with IVH were treated with tPA following failed AAC. Successful resolution of IVH occurred in 22/31 (71%) patients. Pump exchange occurred in 9/31 (29%) patients. Gastrointestinal bleeding occurred in 7/31 (22.6%) patients. Ischemic CVA occurred in 6/31 (19.4%) patients. CONCLUSIONS: Management of IVH with administration of low-dose tPA after failed AAC is feasible and may prevent pump exchange in some patients.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Trombosis , Anticoagulantes/efectos adversos , Fibrinógeno/uso terapéutico , Hemorragia Gastrointestinal/etiología , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Hemólisis , Humanos , Estudios Retrospectivos , Trombosis/prevención & control , Activador de Tejido Plasminógeno/efectos adversos
16.
Front Cardiovasc Med ; 9: 890108, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35898277

RESUMEN

Advanced heart failure (AHF) is associated with increased morbidity and mortality, and greater healthcare utilization. Recognition requires a thorough clinical assessment and appropriate risk stratification. There are persisting inequities in the allocation of AHF therapies. Women are less likely to be referred for evaluation of candidacy for heart transplantation or left ventricular assist device despite facing a higher risk of AHF-related mortality. Sex-specific risk factors influence progression to advanced disease and should be considered when evaluating women for advanced therapies. The purpose of this review is to discuss the role of sex hormones on the pathophysiology of AHF, describe the clinical presentation, diagnostic evaluation and definitive therapies of AHF in women with special attention to pregnancy, lactation, contraception and menopause. Future studies are needed to address areas of equipoise in the care of women with AHF.

18.
JACC Case Rep ; 4(10): 632-638, 2022 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-35615210

RESUMEN

We present 3 cases of inflammatory cardiomyopathies illustrating the need for a multimodality imaging and multidisciplinary approach for diagnosis and treatment. (Level of Difficulty: Intermediate.).

20.
Clin Transplant ; 36(4): e14571, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34964505

RESUMEN

BACKGROUND: Hypogammaglobulinemia (HGG) is a complication of solid organ transplantation leading to increased risk of infections. Intravenous immunoglobulin G (IVIG) replacement in patients with HGG may be able to reduce risk and morbidity associated with infection; however, there is scarce data about IVIG in mild to moderate HGG (IgG 400-700 mg/dl) and heart transplant recipients. METHODS: A single center, retrospective study was performed in heart transplant recipients with mild (IgG 500-700 mg/dl) to moderate (IgG 400-499 mg/dl) HGG in the presence of an infection. RESULTS: Forty-two patients were included in this study; 19 patients (45.2%) received IVIG and 23 (54.8%) patients did not. Patients in the IVIG group received on average one dose of IVIG at 0.5 g/kg. No differences in incidence of new infection at 3 months (26.3% vs. 17.4%; P = .71) and 6 months (42.1% vs. 34.8%; P = .63) were observed between the IVIG and non-IVIG groups. Infections based on mild or moderate HGG also had no differences at 3 and 6 months. CONCLUSION: Our findings suggest that a single infusion of IVIG in mild to moderate HGG may have little to no benefit in reducing incidence of new infections. Larger prospective studies are needed to confirm these findings.


Asunto(s)
Agammaglobulinemia , Trasplante de Corazón , Agammaglobulinemia/tratamiento farmacológico , Agammaglobulinemia/etiología , Trasplante de Corazón/efectos adversos , Humanos , Inmunoglobulina G , Inmunoglobulinas Intravenosas/uso terapéutico , Estudios Retrospectivos , Receptores de Trasplantes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...