Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
1.
J Thorac Imaging ; 39(1): 18-33, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37884389

RESUMEN

Congenital heart diseases affect 1% of all live births in the general population. The prognosis of these children is increasingly improving due to advances in medical care and surgical treatment. Imaging is also evolving rapidly to assess accurately complex cardiac anomalies prenatally and postnatally. Transthoracic echocardiography is the gold-standard imaging technique to diagnose and follow-up children with congenital heart disease. Cardiac computed tomography imaging plays a key role in the diagnosis of children with congenital heart defects that require intervention, due to its high temporal and spatial resolution, with low radiation doses. It is challenging for radiologists, not primarily specialized in this field, to perform and interpret these studies due to the difficult anatomy, physiology, and postsurgical changes. Technical challenges consist of necessary electrocardiogram gating and contrast bolus timing to obtain an optimal examination. This article aims to define indications for pediatric cardiac computed tomography, to explain how to perform and report these studies, and to discuss future applications of this technique.


Asunto(s)
Cardiopatías Congénitas , Radiología , Humanos , Niño , Corazón , Cardiopatías Congénitas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Ecocardiografía
2.
Pediatr Radiol ; 54(1): 136-145, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38099929

RESUMEN

BACKGROUND: Research into artificial intelligence (AI)-based fracture detection in children is scarce and has disregarded the detection of indirect fracture signs and dislocations. OBJECTIVE: To assess the diagnostic accuracy of an existing AI-tool for the detection of fractures, indirect fracture signs, and dislocations. MATERIALS AND METHODS: An AI software, BoneView (Gleamer, Paris, France), was assessed for diagnostic accuracy of fracture detection using paediatric radiology consensus diagnoses as reference. Radiographs from a single emergency department were enrolled retrospectively going back from December 2021, limited to 1,000 radiographs per body part. Enrolment criteria were as follows: suspected fractures of the forearm, lower leg, or elbow; age 0-18 years; and radiographs in at least two projections. RESULTS: Lower leg radiographs showed 607 fractures. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were high (87.5%, 87.5%, 98.3%, 98.3%, respectively). Detection rate was low for toddler's fractures, trampoline fractures, and proximal tibial Salter-Harris-II fractures. Forearm radiographs showed 1,137 fractures. Sensitivity, specificity, PPV, and NPV were high (92.9%, 98.1%, 98.4%, 91.7%, respectively). Radial and ulnar bowing fractures were not reliably detected (one out of 11 radial bowing fractures and zero out of seven ulnar bowing fractures were correctly detected). Detection rate was low for styloid process avulsions, proximal radial buckle, and complete olecranon fractures. Elbow radiographs showed 517 fractures. Sensitivity and NPV were moderate (80.5%, 84.7%, respectively). Specificity and PPV were high (94.9%, 93.3%, respectively). For joint effusion, sensitivity, specificity, PPV, and NPV were moderate (85.1%, 85.7%, 89.5%, 80%, respectively). For elbow dislocations, sensitivity and PPV were low (65.8%, 50%, respectively). Specificity and NPV were high (97.7%, 98.8%, respectively). CONCLUSIONS: The diagnostic performance of BoneView is promising for forearm and lower leg fractures. However, improvement is mandatory before clinicians can rely solely on AI-based paediatric fracture detection using this software.


Asunto(s)
Luxaciones Articulares , Fracturas del Radio , Fracturas de Salter-Harris , Fracturas del Cúbito , Humanos , Niño , Recién Nacido , Lactante , Preescolar , Adolescente , Inteligencia Artificial , Estudios Retrospectivos , Fracturas del Radio/diagnóstico por imagen , Fracturas del Cúbito/diagnóstico por imagen , Radiografía
3.
Eur Radiol ; 2023 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-37855853

RESUMEN

OBJECTIVES: To assess the evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between years 2000 and 2021. METHODS: Pediatric patients (≤ 16 years) referred for 18F-FDG PET/CT or PET/MR imaging of the body during 2000 and 2021 were retrospectively included. The amount of administered radiotracer activity in megabecquerel (MBq) was recorded, and signal-to-noise ratio (SNR) was measured in the right liver lobe with a 4 cm3 volume of interest as an indicator for objective image quality. Descriptive statistics were computed. RESULTS: Two hundred forty-three children and adolescents underwent a total of 466 examinations. The median injected 18F-FDG activity in MBq decreased significantly from 296 MBq in 2000-2005 to 100 MBq in 2016-2021 (p < 0.001), equaling approximately one-third of the initial amount. The median SNR ratio was stable during all years with 11.7 (interquartile range [IQR] 10.7-12.9, p = 0.133). CONCLUSIONS: Children have benefited from a massive reduction in the administered 18F-FDG dose over the past 20 years without compromising objective image quality. CLINICAL RELEVANCE STATEMENT: Radiotracer dose was reduced considerably over the past two decades of pediatric F-18-fluorodeoxyglucose PET/CT and PET/MR imaging highlighting the success of technical innovations in pediatric PET imaging. KEY POINTS: • The evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between 2000 and 2021 was assessed. • The injected tracer activity decreased by 66% during the study period from 296 megabecquerel (MBq) to 100 MBq (p < 0.001). • The continuous implementation of technical innovations in pediatric hybrid 18F-FDG PET has led to a steady decrease in the amount of applied radiotracer, which is particularly beneficial for children who are more sensitive to radiation.

4.
Radiol Med ; 128(10): 1225-1235, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37620674

RESUMEN

PURPOSE: Four-dimensional time-resolved phase-contrast cardiovascular magnetic resonance imaging (4D flow MRI) enables blood flow quantification in multiple vessels, which is crucial for patients with congenital heart disease (CHD). We investigated net flow volumes in the ascending aorta and pulmonary arteries by four different postprocessing software packages for 4D flow MRI in comparison with 2D cine phase-contrast measurements (2D PC). MATERIAL AND METHODS: 4D flow and 2D PC datasets of 47 patients with biventricular CHD (median age 16, range 0.6-52 years) were acquired at 1.5 T. Net flow volumes in the ascending aorta, the main, right, and left pulmonary arteries were measured using four different postprocessing software applications and compared to offset-corrected 2D PC data. Reliability of 4D flow postprocessing software was assessed by Bland-Altman analysis and intraclass correlation coefficient (ICC). Linear regression of internal flow controls was calculated. Interobserver reproducibility was evaluated in 25 patients. RESULTS: Correlation and agreement of flow volumes were very good for all software compared to 2D PC (ICC ≥ 0.94; bias ≤ 5%). Internal controls were excellent for 2D PC (r ≥ 0.95, p < 0.001) and 4D flow (r ≥ 0.94, p < 0.001) without significant difference of correlation coefficients between methods. Interobserver reliability was good for all vendors (ICC ≥ 0.94, agreement bias < 8%). CONCLUSION: Haemodynamic information from 4D flow in the large thoracic arteries assessed by four commercially available postprocessing applications matches routinely performed 2D PC values. Therefore, we consider 4D flow MRI-derived data ready for clinical use in patients with CHD.


Asunto(s)
Cardiopatías Congénitas , Imagen por Resonancia Magnética , Humanos , Lactante , Preescolar , Niño , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Reproducibilidad de los Resultados , Velocidad del Flujo Sanguíneo/fisiología , Aorta/diagnóstico por imagen , Programas Informáticos , Imagenología Tridimensional/métodos
5.
J Oral Maxillofac Surg ; 81(7): 820-830, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37086749

RESUMEN

PURPOSE: Similarities in initial presentations of temporomandibular joint (TMJ) involvement from juvenile idiopathic arthritis (JIA), idiopathic condylar resorption, and other forms of progressive TMJ destruction in children create diagnostic confusion. Treatment pathways, however, depend on determination of etiology. The purpose of this study was to compare TMJ magnetic resonance images (MRIs) of patients with joint degeneration localized to the TMJs to those with JIA and TMJ involvement. STUDY DESIGN, SETTING, SAMPLE: This is a retrospective cross-sectional study including subjects younger than 18 years that presented from February 2008 to October 2019 with clinical TMJ degeneration, a gadolinium-enhanced TMJ MRI and a negative pediatric rheumatologic workup (non-JIA group), and a series of age and sex-matched subjects with TMJ degeneration on gadolinium-enhanced MRI and JIA (JIA group). MRIs were evaluated in a blinded fashion by 1 pediatric radiologist. The primary outcome variable was the radiologist's accuracy in predicting study grouping, assessed in 1 randomly-selected joint per patient. Secondary outcome variables included MRI characteristics of inflammation, osseous damage and articular disc morphology. Independent samples t-tests, sensitivity/specificity, Fisher's exact and Mann-Whitney tests were computed as applicable, and P < .05 was considered significant. RESULTS: The sample included 34 subjects: 16 non-JIA (75% female, age 13.9 ± 2.8 years) and 18 JIA (77% female, age 13.6 ± 2.8 years) (P ≥ .738). The radiologist correctly classified 64.7% of subjects as non-JIA or JIA (P = .078, sensitivity = 94.4%, specificity = 31.3%). Inflammatory and osseous findings were similar between groups (P ≥ .073). The disc was anteriorly displaced in 9 non-JIA and 0 JIA joints (P < .001, sensitivity = 100%, specificity = 100%) and flattened in 3 non-JIA and 14 JIA joints (P = .006, sensitivity = 38.9%, specificity = 90.6%). CONCLUSION AND RELEVANCE: Inflammatory and osseous findings on gadolinium-enhanced TMJ MRIs are insufficient to determine the etiology of progressive TMJ destruction. Disc characteristics, however, significantly differ between JIA and non-JIA etiologies and may be important in differentiating these conditions.


Asunto(s)
Artritis Juvenil , Trastornos de la Articulación Temporomandibular , Niño , Humanos , Femenino , Adolescente , Masculino , Artritis Juvenil/diagnóstico por imagen , Artritis Juvenil/complicaciones , Estudios Retrospectivos , Trastornos de la Articulación Temporomandibular/diagnóstico por imagen , Trastornos de la Articulación Temporomandibular/etiología , Gadolinio , Estudios Transversales , Articulación Temporomandibular/diagnóstico por imagen , Articulación Temporomandibular/patología , Imagen por Resonancia Magnética/métodos
6.
Pediatr Res ; 94(3): 931-943, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36944722

RESUMEN

Patients with severe congenital heart disease (CHD) are at risk for impaired neurodevelopment. Cerebral blood supply may be diminished by congenital anomalies of cardiovascular anatomy and myocardial function. The aim of this scoping review was to summarize the current knowledge on cerebral hemodynamics in infants with severe CHD. A scoping review was performed. Five databases were searched for articles published from 01/1990 to 02/2022 containing information on cerebral hemodynamics assessed by neuroimaging methods in patients with severe CHD within their first year of life. A total of 1488 publications were identified, of which 26 were included. Half of the studies used Doppler ultrasound, and half used magnetic resonance imaging techniques. Studies focused on preoperative findings of cerebral hemodynamics, effects of surgical and conservative interventions, as well as on associations between cerebral hemodynamics and brain morphology or neurodevelopment. Cerebral perfusion was most severely affected in patients with single ventricle and other cyanotic disease. Neuroimaging methods provide a large variety of information on cerebral hemodynamics. Nevertheless, small and heterogeneous cohorts complicate this field of research. Further studies are needed to improve our understanding of the link between CHD and altered cerebral hemodynamics to optimize neuroprotection strategies. IMPACT: Postnatal cerebral hemodynamics are altered in infants with congenital heart disease (CHD) as compared to healthy controls, especially in most severe types such as single ventricle or other cyanotic CHD. Associations of these alterations with brain volume and maturation reveal their clinical relevance. Research in this area is limited due to the rarity and heterogeneity of diagnoses. Furthermore, longitudinal studies have rarely been conducted. Further effort is needed to better understand the deviation from physiological cerebral perfusion and its consequences in patients with CHD to optimize neuroprotection strategies.


Asunto(s)
Sistema Cardiovascular , Cardiopatías Congénitas , Corazón Univentricular , Humanos , Lactante , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico por imagen , Hemodinámica/fisiología , Imagen por Resonancia Magnética , Neuroimagen
7.
Fetal Diagn Ther ; 50(1): 8-16, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36617416

RESUMEN

INTRODUCTION: The aim of this study was to evaluate the feasibility of identifying the fetal cardiac and thoracic vascular structures with non-gated dynamic balanced steady-state free precession (SSFP) MRI sequences. METHODS: We retrospectively assessed the visibility of cardiovascular anatomy in 60 fetuses without suspicion of congenital heart defect. Non-gated dynamic balanced SSFP sequences were acquired in three anatomic planes of the fetal thorax. The images were analyzed following a segmental approach in consensus reading by an experienced pediatric cardiologist and radiologist. An imaging score was defined by giving one point to each visualized structure, yielding a maximum score of 21 points. Image quality was rated from 0 (poor) to 2 (excellent). The influence of gestational age (GA), field strength, placenta position, and maternal panniculus on image quality and imaging score were tested. RESULTS: 30 scans were performed at 1.5T, 30 at 3T. Heart position, atria, and ventricles could be seen in all 60 fetuses. Basic diagnosis (>12 points) was achieved in 54 cases. The mean imaging score was 16.8+/-3.8. Maternal panniculus (r = -0.3; p = 0.015) and GA (r = 0.6; p < 0.001) correlated with imaging score. Field strength influenced image quality, with 1.5T being better than 3T images (p = 0.012). Imaging score or quality was independent of placenta position. CONCLUSION: Fetal cardiac MRI with non-gated SSFP sequences enables recognition of basic cardiovascular anatomy.


Asunto(s)
Cardiopatías Congénitas , Imagen por Resonancia Magnética , Embarazo , Niño , Femenino , Humanos , Estudios Retrospectivos , Estudios de Factibilidad , Imagen por Resonancia Magnética/métodos , Feto , Cardiopatías Congénitas/diagnóstico por imagen
8.
Diagnostics (Basel) ; 13(2)2023 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-36672990

RESUMEN

In many cardiac diseases, right and left ventricular volumes in systole and diastole are diagnostically and prognostically relevant. Measurements are made by segmentation of the myocardial borders on cardiac magnetic resonance (CMR) images. Automatic detection of myocardial contours is possible by signal thresholding techniques, but must be validated before use in clinical settings. Biventricular volumes were measured in end-diastole (EDVi) and in end-systole (ESVi) both manually and with the MassK application, with signal thresholds at 30%, 50%, and 70%. Stroke volumes (SV) and cardiac indices (CI) were calculated from volumetric measurements and from flow measured in the ascending aorta and the main pulmonary artery, and both methods were compared. Reproducibility of volumetric measurements was tested in 20 patients. Measurements were acquired in 94 patients aged 15 ± 9 years referred for various conditions. EDVi and ESVi of both ventricles were largest with manual segmentation and inversely proportional to the MassK threshold. Manual and k30 SV and CI corresponded best to flow measurements. Interobserver variability was low for all volumes manually and with MassK. In conclusion, manual and 30% threshold-based biventricular volume segmentation agree best with two-dimensional, phantom-corrected phase contrast flow measurements in a young cardiac referral population and are well reproducible.

9.
Arthritis Rheumatol ; 75(1): 4-14, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36041065

RESUMEN

Involvement of the temporomandibular joint (TMJ) is common in juvenile idiopathic arthritis (JIA). TMJ arthritis can lead to orofacial symptoms, orofacial dysfunction, and dentofacial deformity with negative impact on quality of life. Management involves interdisciplinary collaboration. No current recommendations exist to guide clinical management. We undertook this study to develop consensus-based interdisciplinary recommendations for management of orofacial manifestations of JIA, and to create a future research agenda related to management of TMJ arthritis in children with JIA. Recommendations were developed using online surveying of relevant stakeholders, systematic literature review, evidence-informed generation of recommendations during 2 consensus meetings, and Delphi study iterations involving external experts. The process included disciplines involved in the care of orofacial manifestations of JIA: pediatric rheumatology, radiology, orthodontics, oral and maxillofacial surgery, orofacial pain specialists, and pediatric dentistry. Recommendations were accepted if agreement was >80% during a final Delphi study. Three overarching management principles and 12 recommendations for interdisciplinary management of orofacial manifestations of JIA were outlined. The 12 recommendations pertained to diagnosis (n = 4), treatment of TMJ arthritis (active TMJ inflammation) (n = 2), treatment of TMJ dysfunction and symptoms (n = 3), treatment of arthritis-related dentofacial deformity (n = 2), and other aspects related to JIA (n = 1). Additionally, a future interdisciplinary research agenda was developed. These are the first interdisciplinary recommendations to guide clinical management of TMJ JIA. The 3 overarching principles and 12 recommendations fill an important gap in current clinical practice. They emphasize the importance of an interdisciplinary approach to diagnosis and management of orofacial manifestations of JIA.


Asunto(s)
Artritis Juvenil , Deformidades Dentofaciales , Trastornos de la Articulación Temporomandibular , Niño , Humanos , Artritis Juvenil/complicaciones , Artritis Juvenil/terapia , Artritis Juvenil/diagnóstico , Consenso , Calidad de Vida , Trastornos de la Articulación Temporomandibular/etiología , Trastornos de la Articulación Temporomandibular/terapia
10.
Pediatr Radiol ; 53(4): 660-676, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36138217

RESUMEN

Advanced cardiorespiratory imaging of the chest with ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI) plays an important role in diagnosing respiratory and cardiac conditions in neonates when radiography and echocardiography alone are not sufficient. This pictorial essay highlights the particularities, clinical indications and technical aspects of applying chest US, cardiac CT and cardiorespiratory MRI techniques specifically to neonates, summarising the first session of the European Society of Paediatric Radiology's cardiothoracic task force.


Asunto(s)
Cardiopatías , Recién Nacido , Niño , Humanos , Imagen Multimodal/métodos , Tomografía Computarizada por Rayos X , Ecocardiografía , Imagen por Resonancia Magnética
11.
Front Pediatr ; 11: 1337568, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38293662

RESUMEN

Background: Left pulmonary artery (LPA) stenting is often required in single ventricle (SV) patients. Due to their close anatomical relationship an LPA stent could potentially compress the left main bronchus (LMB). We assessed the impact of LPA stenting on bronchial size, pulmonary volumes, and lung function in a cohort of SV patients. Methods: Forty-nine patients underwent cardiovascular magnetic resonance (CMR) and 36 spirometry 11 (8-15) years after Fontan. All patients were free of respiratory symptoms. LPA stents were inserted in 17 (35%) patients at 8.8 (3.4-12.6) years. Area/shape of the main bronchi (n = 46) and lung volumes (n = 47) were calculated from CMR-ZTE images for each lung and transformed in right-to-left (r/l) ratio and indexed for BSA. The effect of early stent insertion (prior to stage III) was analyzed. Results: Patients with LPA stent had larger r/l ratio for main bronchus area (p < 0.001) and r/l ratio difference for lung volumes was slightly larger in patients with early stenting. A trend toward a deformation of LMB shape in patients with LPA stent and toward a higher prevalence of abnormal spirometry in patients with early stent implantation was observed. Conclusions: In this cohort of patients, early insertion of LPA stents seems to relate with smaller LMB sizes and a trend toward smaller left lung volume and higher prevalence of impaired lung function. Whether these findings are caused by the stent or, at least to a certain degree, present prior to the implantation needs to be verified.

12.
BMC Med Imaging ; 22(1): 169, 2022 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-36167535

RESUMEN

PURPOSE: To find the best level to measure aortic flow for quantification of aortic regurgitation (AR) in 4D flow CMR. METHODS: In 27 congenital heart disease patients with AR (67% male, 31 ± 16 years) two blinded observers measured antegrade, retrograde, net aortic flow volumes and regurgitant fractions at 6 levels in 4D flow: (1) below the aortic valve (AV), (2) at the AV, (3) at the aortic sinus, (4) at the sinotubular junction, (5) at the level of the pulmonary arteries (PA) and (6) below the brachiocephalic trunk. 2D phase contrast (2DPC) sequences were acquired at the level of PA. All patients received prior transthoracic echocardiography (TTE) with AR severity grading according to a recommended multiparametric approach. RESULTS: After assigning 2DPC measurements into AR grading, agreement between TTE AR grading and 2DPC was good (κ = 0.88). In 4D flow, antegrade flow was similar between the six levels (p = 0.87). Net flow was higher at level 1-2 than at levels 3-6 (p < 0.05). Retrograde flow and regurgitant fraction at level 1-2 were lower compared to levels 3-6 (p < 0.05). Reproducibility (inter-reader agreement: ICC 0.993, 95% CI 0.986-0.99; intra-reader agreement: ICC 0.982, 95%CI 0.943-0.994) as well as measurement agreement between 4D flow and 2DPC (ICC 0.994; 95%CI 0.989 - 0.998) was best at the level of PA. CONCLUSION: For estimating severity of AR in 4D flow, best reproducibility along with best agreement with 2DPC measurements can be expected at the level of PA. Measurements at AV or below AV might underestimate AR.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética , Masculino , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
13.
Jpn J Radiol ; 40(7): 722-729, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35237890

RESUMEN

PURPOSE: Lung magnetic resonance imaging (MRI) using conventional sequences is limited due to strong signal loss by susceptibility effects of aerated lung. Our aim is to assess lung signal intensity in children on ultrashort echo-time (UTE) and zero echo-time (ZTE) sequences. We hypothesize that lung signal intensity can be correlated to lung physical density. MATERIALS AND METHODS: Lung MRI was performed in 17 children with morphologically normal lungs (median age: 4.7 years, range 15 days to 17 years). Both lungs were manually segmented in UTE and ZTE images and the average signal intensities were extracted. Lung-to-background signal ratios (LBR) were compared for both sequences and between both patient groups using non-parametric tests and correlation analysis. Anatomical region-of-interest (ROI) analysis was performed for the normal cohort for assessment of the anteroposterior lung gradient. RESULTS: There was no significant difference between LBR of normal lungs using UTE and ZTE (p < 0.05). Both sequences revealed a LBR age-dependency with a high negative correlation for UTE (Rs = - 0.77; range 2.98-1.41) and ZTE (Rs = - 0.82; range 2.66-1.38)). Signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were age-dependent for both sequences. SNR was higher for children up to 2 years old with 3D UTE Cones while for the rest it was higher with 4D ZTE. CNR was similar for both sequences. Posterior lung areas exhibited higher signal intensity compared to anterior ones (UTE 9.4% and ZTE 12% higher), both with high correlation coefficients (R2UTE = 0.94, R2ZTE = 0.97). CONCLUSION: The ZTE sequence can measure signal intensity similarly to UTE in pediatric patients. Both sequences reveal an age- and gravity-dependency of LBR.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Adolescente , Niño , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos
14.
Pediatr Radiol ; 52(5): 951-958, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35076727

RESUMEN

BACKGROUND: Children with orofacial deformity may require repeated imaging of the facial skeleton. OBJECTIVE: To test the feasibility and accuracy of "black bone" magnetic resonance imaging (MRI) for assessing facial deformity in children. MATERIALS AND METHODS: Three-dimensional (3-D) black bone gradient echo sequences (flip angle 5°, submillimetre spatial resolution) from 10 children (median age: 13 years, range: 2-16 years), who underwent MRI of the temporomandibular joints, were evaluated with multiplanar reconstruction and 3-D rendering tools. Intra- and inter-reader agreement was investigated for measuring the height of the mandibular ramus and condyle, basal length of the mandible, gonion angle and mandibular inclination angle by intraclass correlation coefficient (ICC) and Bland-Altman analysis. Absolute percentage error was calculated with the average of all measurements serving as reference. RESULTS: Sixty linear and 40 angle measurements were obtained on reformatted multiplanar black bone images with excellent inter-reader agreement (ICC > 0.99, agreement bias < 1.4 mm/ < 1.5°) and small error (median absolute error < 3%). The black bone images required inversion of the signal intensity and removal of air before they could be processed with standard volume rendering tools. The diagnostic utility of 3-D views for assessing the facial skeleton was sufficient except for assessing dental relationship. CONCLUSION: Morphometric measurements of the mandible can be obtained from black bone MRI with comparable inter-rater agreement to that reported for cone beam computed tomography (CT). With improvements of 3-D rendering techniques and software, black bone MRI may become a radiation-free alternative to CT in children with facial deformities.


Asunto(s)
Mandíbula , Cráneo , Adolescente , Niño , Tomografía Computarizada de Haz Cónico/métodos , Cabeza , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Mandíbula/diagnóstico por imagen
15.
Arthritis Care Res (Hoboken) ; 74(2): 308-316, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33555146

RESUMEN

OBJECTIVE: To determine the relative importance weights of items and grades of a newly developed additive outcome measure called the juvenile idiopathic arthritis (JIA) magnetic resonance imaging (MRI) scoring system for the temporomandibular joint (TMJ) (JAMRIS-TMJ). METHODS: An adaptive partial-profile, discrete choice experiment (DCE) survey using the 1000Minds platform was independently completed by members of an expert group consisting of radiologists and non-radiologist clinicians to determine the group-averaged relative weights for the JAMRIS-TMJ. Subsequently, an image-based vignette ranking exercise was done, during which experts individually rank ordered 14 patient vignettes for disease severity while blinded to the weights and unrestricted to JAMRIS-TMJ assessment criteria. Validity of the weighted JAMRIS-TMJ was tested by comparing the consensus-graded, DCE-weighted JAMRIS-TMJ score of the vignettes with their unrestricted image-based ranks provided by the experts. RESULTS: Nineteen experts completed the DCE survey, and 21 completed the vignette ranking exercise. Synovial thickening and joint enhancement showed higher weights per raw score compared to bone marrow items and effusion in the inflammatory domain, while erosions and condylar flattening showed nonlinear and higher weights compared to disk abnormalities in the damage domain. The weighted JAMRIS-TMJ score of the vignettes correlated highly with the ranks from the unrestricted comparison method, with median Spearman's ρ of 0.92 (interquartile range [IQR] 0.87-0.95) for the inflammation and 0.93 (IQR 0.90-0.94) for the damage domain. CONCLUSION: A DCE survey was used to quantify the importance weights of the items and grades of the JAMRIS-TMJ. The weighted score showed high convergent validity with an unrestricted, holistic vignette ranking method.


Asunto(s)
Artritis Juvenil/diagnóstico por imagen , Imagen por Resonancia Magnética , Índice de Severidad de la Enfermedad , Articulación Temporomandibular/diagnóstico por imagen , Humanos
16.
Am J Cardiol ; 166: 88-96, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34949470

RESUMEN

Our aim was to assess changes of right ventricular end-diastolic volumes (RVEDVi) and right ventricular ejection fraction (RVEF) in asymptomatic adults with repaired tetralogy of Fallot, with native right ventricular outflow tract and severe pulmonary regurgitation by serial cardiac magnetic resonance imaging (CMR). The study included 23 asymptomatic adults who underwent ≥3 CMR studies (total of 88 CMR studies). We compared changes in RVEDVi and RVEF between first and last study (median follow-up: 8.8 years, interquartile range: 6.3 to 13.1 years) and between all study pairs. Variability of measurements between study pairs (65 consecutive and 139 nonconsecutive CMR study pairs) were assessed using Bland-Altman analysis and intraclass correlation coefficients. On average, there were no significant changes of RVEDVi or RVEF over the study period (change in RVEDVi: +0.4 ± 17.8 ml/m2, change in RVEF: -1.0 ± 5.5%). Assessment of variability of measurements between study pairs demonstrated no systematic change in RVEDVi and RVEF between study pairs with limits of agreement within the range of previously published studies (RVEDVi -29.1 to +27.2 ml/m2; RVEF -11.5% to 10.2%). High intraclass correlation coefficients for RVEDVi (0.943, 95% CI 0.906 to 0.965, p <0.001) and RVEF (0.815, 95% CI 0.697 to 0.887, p <0.0001) indicate high reliability of reported measurements. In conclusion, in asymptomatic adults with repaired tetralogy of Fallot with native right ventricular outflow tracts and severe pulmonary regurgitation, CMR measurements of RV volumes and RVEF remain stable during follow-up with variability between CMR studies in individual patients, as expected for interobserver and interstudy variability. Measurements derived from a single CMR study or changes occurring between 2 CMR studies should be used with caution for clinical decision-making.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia de la Válvula Pulmonar , Tetralogía de Fallot , Disfunción Ventricular Derecha , Adulto , Procedimientos Quirúrgicos Cardíacos/métodos , Humanos , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética/métodos , Insuficiencia de la Válvula Pulmonar/diagnóstico , Insuficiencia de la Válvula Pulmonar/etiología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Volumen Sistólico , Tetralogía de Fallot/complicaciones , Tetralogía de Fallot/cirugía , Función Ventricular Derecha
17.
J Clin Med ; 10(18)2021 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-34575158

RESUMEN

Contrast-enhanced magnetic resonance imaging (MRI) remains the most comprehensive modality to assess juvenile idiopathic arthritis (JIA)-related inflammation and osteochondral damage in the temporomandibular joints (TMJ). This study tested the reliability of a new JIA MRI scoring system for TMJ (JAMRIS-TMJ) and the impact of variations in calibration and reader specialty. Thirty-one MRI exams of bilateral TMJs were scored independently using the JAMRIS-TMJ by 20 readers consisting of radiologists and non-radiologist clinicians in three reading groups, with or without a calibrating atlas and/or tutorial. The inter-reader reliability in the multidisciplinary cohort assessed by the generalizability coefficient was 0.61-0.67 for the inflammatory and 0.66-0.74 for the damage domain. The atlas and tutorial did not improve agreement within radiologists, but improved the agreement between radiologist and non-radiologist groups. Agreements between different calibration levels were 0.02 to 0.08 lower by the generalizability coefficient compared to agreement within calibration levels; agreement between specialty groups was 0.04 to 0.10 lower than within specialty groups. Averaging two radiologists raised the reliability above 0.8 for both domains. Therefore, the reliability of JAMRIS-TMJ was moderate-to-good depending on the presence of specialty and calibration differences. The atlas and tutorial are necessary to improve reliability when the reader cohort consists of multiple specialties.

18.
Pediatr Cardiol ; 42(7): 1625-1634, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34313807

RESUMEN

Cardiac MR (CMR) is a standard modality for assessing ventricular function of single ventricles. CMR feature-tracking (CMR-FT) is a novel application enabling strain measurement on cine MR images and is used in patients with congenital heart diseases. We sought to assess the feasibility of CMR-FT in Fontan patients and analyze the correlation between CMR-FT strain values and conventional CMR volumetric parameters, clinical findings, and biomarkers. Global circumferential (GCS) and longitudinal (GLS) strain were retrospectively measured by CMR-FT on Steady-State Free Precession cine images. Data regarding post-operative course at Fontan operation, and medication, exercise capacity, invasive hemodynamics, and blood biomarkers at a time interval ± 6 months from CMR were collected. Forty-seven patients underwent CMR 11 ± 6 years after the Fontan operation; age at CMR was 15 ± 7 years. End-diastolic volume (EDV) of the SV was 93 ± 37 ml/m2, end-systolic volume (ESV) was 46 ± 23 ml/m2, and ejection fraction (EF) was 51 ± 11%. Twenty (42%) patients had a single right ventricle (SRV). In single left ventricle (SLV), GCS was higher (p < 0.001), but GLS was lower (p = 0.04) than in SRV. GCS correlated positively with EDV (p = 0.005), ESV (p < 0.001), and EF (p ≤ 0.0001). GLS correlated positively with EF (p = 0.002), but not with ventricular volumes. Impaired GCS correlated with decreased ventricular function (p = 0.03) and atrioventricular valve regurgitation (p = 0.04) at echocardiography, direct atriopulmonary connection (p = 0.02), post-operative complications (p = 0.05), and presence of a rudimentary ventricle (p = 0.01). A reduced GCS was associated with increased NT-pro-BNP (p = 0.05). Myocardial deformation can be measured by CMR-FT in Fontan patients. SLVs have higher GCS, but lower GLS than SRVs. GCS correlates with ventricular volumes and EF, whereas GLS correlates with EF only. Myocardial deformation shows a relationship with several clinical parameters and NT-pro-BNP.


Asunto(s)
Imagen por Resonancia Cinemagnética , Miocardio , Biomarcadores , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Función Ventricular Izquierda
19.
Eur J Radiol ; 139: 109699, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33932715

RESUMEN

PURPOSE: To compare objective and subjective parameters in image quality and radiation dose of two MDCTs (helical 64 detector CT vs. axial 256 detector CT) in paediatric lung CT. METHODS: Radiation dose and image quality were compared between non-enhanced lung CT from a helical 64-slice multidetector CT (MDCT 1) and a 256-slice scanner (MDCT 2) with axial wide-cone acquisition and using deep learning image reconstruction. In 23 size-matched paediatric studies (age 2-18 years) from each scanner, the radiation exposure, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), image sharpness and delineation of small airways were assessed. Subjective image quality was rated by 6 paediatric radiologists. RESULTS: While MDCT 2 provided higher SNR and CNR, subjective image quality was not significantly different between studies from both scanners. Radiation exposure was lower in studies from MDCT 2 (CTDIvol 0.26 ± 0.14 mGy, effective dose 0.23 ± 0.11 mSv) than from MDCT 1 (CTDIvol 0.96 ± 0.52 mGy, effective dose 1.13 ± 0.58 mSv), p < 0.001. Despite lower radiation dose for the scout images, the relative scout-scan-ratio increased from 2.64 ± 1.42 % in MDCT 1 to 6.60 ± 5.03 % in MDCT 2 (p = 0.001). CONCLUSIONS: By using latest scanner technology effective radiation dose can be reduced to 0.1-0.3 mSv for lung CT in children without compromising image quality. Scout image dose increasingly accounts for substantial portions of the total scan dose and needs to be optimized. In children CT should be performed on state-of-the-art MDCT scanners with size-adapted exposure protocols and iterative reconstruction.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada Multidetector , Adolescente , Niño , Preescolar , Humanos , Pulmón/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Relación Señal-Ruido
20.
Pediatr Radiol ; 51(9): 1608-1620, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33904952

RESUMEN

BACKGROUND: A hyperinflammatory immune-mediated shock syndrome has been recognised in children exposed to the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus that causes coronavirus disease 2019 (COVID-19). OBJECTIVE: To describe typical imaging findings in children with multisystem inflammatory syndrome associated with COVID-19. MATERIALS AND METHODS: During the first wave of the COVID-19 pandemic, imaging studies and clinical data from children treated for multisystem inflammatory syndrome were collected from multiple centres. Standardised case templates including demographic, biochemical and imaging information were completed by participating centres and reviewed by paediatric radiologists and paediatricians. RESULTS: We included 37 children (21 boys; median age 8.0 years). Polymerase chain reaction (PCR) testing was positive for SARS-CoV-2 in 15/37 (41%) children and immunoglobulins in 13/19 children (68%). Common clinical presentations were fever (100%), abdominal pain (68%), rash (54%), conjunctivitis (38%) and cough (32%). Thirty-three children (89%) showed laboratory or imaging findings of cardiac involvement. Thirty of the 37 children (81%) required admission to the intensive care unit, with good recovery in all cases. Chest radiographs demonstrated cardiomegaly in 54% and signs of pulmonary venous hypertension/congestion in 73%. The most common chest CT abnormalities were ground-glass and interstitial opacities (83%), airspace consolidation (58%), pleural effusion (58%) and bronchial wall thickening (42%). Echocardiography revealed impaired cardiac function in half of cases (51%) and coronary artery abnormalities in 14%. Cardiac MRI showed myocardial oedema in 58%, pericardial effusion in 42% and decreased left ventricular function in 25%. Twenty children required imaging for abdominal symptoms, the commonest abnormalities being free fluid (71%) and terminal ileum wall thickening (57%). Twelve children underwent brain imaging, showing abnormalities in two cases. CONCLUSION: Children with multisystem inflammatory syndrome showed pulmonary, cardiac, abdominal and brain imaging findings, reflecting the multisystem inflammatory disease. Awareness of the imaging features of this disease is important for early diagnosis and treatment.


Asunto(s)
COVID-19/diagnóstico por imagen , Pulmón/diagnóstico por imagen , SARS-CoV-2/aislamiento & purificación , Tomografía Computarizada por Rayos X/métodos , COVID-19/diagnóstico , COVID-19/epidemiología , Prueba de Ácido Nucleico para COVID-19 , Niño , Preescolar , Ecocardiografía , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Pandemias , SARS-CoV-2/genética , Síndrome de Respuesta Inflamatoria Sistémica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...