2.
Urol Pract ; 11(3): 462-468, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38526412

RESUMEN

INTRODUCTION: The Karl Storz FLEX-XC1 is a novel single-use flexible ureteroscope that uses the same videographics platform as its reusable digital counterpart. We evaluated the technical performance of the FLEX-XC1 in its initial clinical use. METHODS: We reviewed a series of consecutive ureteroscopy procedures performed by 2 endourologists using the FLEX-XC1 for indications for which we typically use a single-use device: total stone burden > 15 mm or > 10 mm in the lower pole, anticipated case duration > 60 minutes, bilateral procedure, or upper tract urothelial cancer procedures. We assessed device tip deflection, intraoperative mechanical failure, and clinical outcomes for each case. Surgeons rated visual clarity, image quality, and maneuverability on a 1 to 5 Likert scale. RESULTS: Of 29 procedures using FLEX-XC1, 27 (93%) were successfully completed. Preoperative upward deflection was < 270° in 6 (21%) cases, and downward deflection was < 270° in 9 (31%) cases. Three types of intraoperative malfunctions occurred: rotational twisting of deflectable tip (4 cases, 13%), device not advancing through distal ureter (1 case, 3%), and working channel not accommodating a 365-µm laser (1 case, 3%). Visual clarity, image quality, and maneuverability were rated as 5 "very good" or 4 "good" in 100%, 100%, and 97% of cases, respectively. No device-specific or general 30-day complications were observed. CONCLUSIONS: The FLEX-XC1 showed comparable image quality and maneuverability to reusable digital devices. We observed incomplete deflection in up to 31% of cases and mechanical failure in 2 cases. The FLEX-XC1 may be advantageous in prolonged cases where maintaining visual clarity is paramount.


Asunto(s)
Cálculos Renales , Ureteroscopios , Humanos , Diseño de Equipo , Ureteroscopía , Cálculos Renales/cirugía
3.
Eur J Orthop Surg Traumatol ; 34(1): 647-652, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37673832

RESUMEN

BACKGROUND: Pubic symphysis osteomyelitis can result from urosymphyseal fistula formation. High rates of sacropelvic insufficiency fractures have been reported in this population. The aim of this study was to describe the presentation and risk factors for sacral insufficiency fractures (SIF) associated with surgical treatment of pubic symphysis osteomyelitis. METHODS: A retrospective review was performed for 54 patients who underwent surgery for pubic symphysis osteomyelitis associated with a urosymphyseal fistula at a single institution from 2009 to 2022. Average age was 71 years and 53 patients (98%) were male. All patients underwent debridement or partial resection of the pubic symphysis at the time of fistula treatment. Average width of the symphyseal defect was 65 mm (range 9-122) after treatment. RESULTS: Twenty patients (37%) developed SIF at a mean time of 4 months from osteomyelitis diagnosis. Rate of sacral fracture on Kaplan-Meier analysis was 31% at 6 months, 39% at 12 months, and 41% at 2 years. Eleven patients developed SIF prior to pubic debridement and 12 patients developed new or worsening of pre-existing SIF following surgery. Width of pubic resection was higher in patients who developed SIF (76 mm vs. 62 mm), but this did not meet statistical significance (p = 0.18). CONCLUSION: Sacral insufficiency fracture is a common sequela of pubic symphysis osteomyelitis. These fractures are often multifocal within the pelvis and can occur even prior to pubic resection. Pubectomy further predisposes these patients to fracture. Clinicians should maintain a high index of suspicion for these injuries in patients with symphyseal osteomyelitis.


Asunto(s)
Fístula , Fracturas por Estrés , Osteomielitis , Sínfisis Pubiana , Humanos , Masculino , Anciano , Femenino , Sínfisis Pubiana/diagnóstico por imagen , Sínfisis Pubiana/cirugía , Fracturas por Estrés/diagnóstico por imagen , Fracturas por Estrés/etiología , Fracturas por Estrés/cirugía , Fístula/complicaciones , Dolor/complicaciones , Osteomielitis/complicaciones , Osteomielitis/diagnóstico
4.
BJU Int ; 131(5): 617-622, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36515438

RESUMEN

OBJECTIVES: To compare the carbon footprint and environmental impact of single-use and reusable flexible cystoscopes. MATERIALS AND METHODS: We analysed the expected clinical lifecycle of single-use (Ambu aScope™ 4 Cysto) and reusable (Olympus CYF-V2) flexible cystoscopes, from manufacture to disposal. Performance data on cumulative procedures between repairs and before decommissioning were derived from a high-volume multispecialty practice. We estimated carbon expenditures per-case using published data on endoscope manufacturing, energy consumption during transportation and reprocessing, and solid waste disposal. RESULTS: A fleet of 16 reusable cystoscopes in service for up to 135 months averaged 207 cases between repairs and 3920 cases per lifecycle. Based on a manufacturing carbon footprint of 11.49 kg CO2 /kg device for reusable flexible endoscopes and 8.54 kg CO2 /kg device for single-use endoscopes, the per-case manufacturing cost was 1.37 kg CO2 for single-use devices and 0.0017 kg CO2 for reusable devices. The solid mass of single-use and reusable devices was 0.16 and 0.57 kg, respectively. For reusable devices, the energy consumption of reusable device reprocessing using an automated endoscope reprocessor was 0.20 kg CO2 , and per-case costs of device repackaging and repair were 0.005 and 0.02 kg CO2 , respectively. The total estimated per-case carbon footprint of single-use and reusable devices was 2.40 and 0.53 kg CO2 , respectively, favouring reusable devices. CONCLUSION: In this lifecycle analysis, the environmental impact of reusable flexible cystoscopes is markedly less than single-use cystoscopes. The primary contributor to the per-case carbon cost of reusable devices is energy consumption of reprocessing.


Asunto(s)
Dióxido de Carbono , Cistoscopios , Humanos , Cistoscopía/métodos , Huella de Carbono , Gastos en Salud
5.
Front Physiol ; 13: 955538, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36091359

RESUMEN

Aberrant carotid body chemoreceptor (CBC) function contributes to increased sympathetic nerve activity (SNA) and reduced renal blood flow (RBF) in chronic heart failure (CHF). Intermittent asphyxia (IA) mimicking sleep apnea is associated with additional increases in SNA and may worsen reductions in RBF and renal PO2 (RPO2) in CHF. The combined effects of decreased RBF and RPO2 may contribute to biochemical changes precipitating renal injury. This study sought to determine the role of CBC activity on glomerular filtration rate (GFR), RBF and RPO2 in CHF, and to assess the additive effects of IA. Furthermore, we sought to identify changes in gene expression that might contribute to renal injury. We hypothesized that GFR, RBF, and RPO2 would be reduced in CHF, that decreases in RBF and RPO2 would be worsened by IA, and that these changes would be ameliorated by CBC ablation (CBD). Finally, we hypothesized that CHF would be associated with pro-oxidative pro-fibrotic changes in renal gene expression that would be ameliorated by CBD. CHF was induced in adult male Sprague Dawley rats using coronary artery ligation (CAL). Carotid body denervation was performed by cryogenic ablation. GFR was assessed in conscious animals at the beginning and end of the experimental period. At 8-weeks post-CAL, cardiac function was assessed via echocardiography, and GFR, baseline and IA RBF and RPO2 were measured. Renal gene expression was measured using qRT-PCR. GFR was lower in CHF compared to sham (p < 0.05) but CBD had no salutary effect. RBF and RPO2 were decreased in CHF compared to sham (p < 0.05), and this effect was attenuated by CBD (p < 0.05). RBF and RPO2 were reduced to a greater extent in CHF vs. sham during exposure to IA (p < 0.05), and this effect was attenuated by CBD for RBF (p < 0.05). Downregulation of antioxidant defense and fibrosis-suppressing genes was observed in CHF vs. sham however CBD had no salutary effect. These results suggest that aberrant CBC function in CHF has a clear modulatory effect on RBF during normoxia and during IA simulating central sleep apnea.