Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38482095

RESUMEN

Takotsubo Cardiomyopathy is an established transient cardiomyopathy found predominately in females with intense emotional and physical strain. It has four notable variants: Apical, Mid-Ventricular, Basal and Focal. Mid Ventricular variant is also referred to as Reverse Takotsubo Cardiomyopathy. Dengue is a viral arthopod-borne tropical disease endemic to Pakistan, with multiple reports of cardiovascular involvement. We report an atypical presentation of a 17 year old male, suffering from Dengue Fever, who presented to a tertiary care hospital with Reverse Takotsubo Cardiomyopathy.

2.
Artículo en Inglés | MEDLINE | ID: mdl-36817305

RESUMEN

The aim of this report is to explore the direct and long-term outcome in a high risk patient who was treated with rotational atherectomy (RA) to assist the placement of drug eluting stents in heavily calcified lesions. The patient presented with acute STEMI and had severely calcified Left main stem (LMS) disease, requiring plaque modification before coronary angioplasty and stent implantation. As the patient was elderly, with multiple comorbids including a number of coronary interventions, a decision of conservative management was made. Patient then re-presented with typical chest pain and pulmonary edema. A Heart Team meeting was called and high risk decision of RA to LMS was taken. His percutaneous transluminal coronary angioplasty (PTCA) to LM and LAD was planned. LMS to LAD was rotablated with 1.75 burr and PTCA with 3.5 NC at 20 Atm. During the procedure, patient developed flash pulmonary edema. In post-operative care, his renal functions deteriorated and nephrology was taken on board. After multiple sessions of hemodialysis, patient was clinically improved and stabilized. The report highlights the expertise required in RA of a complex LMS disease and judicious post-procedure care which resulted in significant reduction of morbidity, mortality and frequent hospitalizations of the patient.

4.
J Geriatr Cardiol ; 18(12): 1068-1070, 2021 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-35136402
6.
Am J Cardiol ; 125(8): 1222-1229, 2020 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-32093955

RESUMEN

New persistent left bundle branch block (NP-LBBB) has been associated with adverse outcomes after TAVI but few predictors thus far reported. We sought to identify predictors of NP-LBBB after TAVI with EvolutR/PRO (ER/EP). From 1/2016 to 4/2019, 544 patients from 2 centers underwent TAVI with Evolut (54% ER, 46% EP) for severe native aortic stenosis. Patients with previous LBBB and pacemaker were excluded. Aortic root analysis was performed using 3Mensio Valves Software and membranous septal length (MSL) was determined using the standard coronal view. Clinical, anatomic and procedural characteristics of 396 Evolut were analyzed and predictors of NP-LBBB were identified. Valve Academic Research Consortium-2 outcomes were reported. At discharge, NP-LBBB was seen in 76(19.2%) patients. NP-LBBB in Evolut was associated with implant depth at left coronary cusp (p = 0.004) and 34 mm ER (p = 0.026). Independent predictors of NP-LBBB in Evolut were shorter MSL (odds ratio [OR] = 0.82 per mm septum, 95% confidence interval [CI] = 0.68 to 0.98,p = 0.030), left ventricular outflow tract (LVOT) eccentricity (OR = 1.04 per %, 95% CI = 1.01 to 1.06,p = 0.002), implant depth at noncoronary cusp (NCC) (OR = 1.28 per mm ventricular, 95% CI = 1.11 to 1.48,p = 0.001) and annular perimeter oversizing ≥20% (OR = 2.38, 95% CI = 1.20 to 4.72, p = 0.013). On ROC curve analysis, MSL ≤6.5 mm, NCC depth ≥3 mm and LVOT eccentricity ≥35% were optimal threshold values to predict NP-LBBB. In Conclusion, shorter MSL, LVOT eccentricity, annular oversizing and deeper implant depth are novel predictors of NP-LBBB in Evolut TAVI. Preprocedural CT assessment of aortic root anatomy may help identify patients at risk for NP-LBBB. In such patients, modifying procedural factors such as higher implant and less annular oversizing may reduce the risk of NP-LBBB. Further evaluation of our hypothesis is warranted.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anatomía & histología , Bloqueo de Rama/epidemiología , Ventrículos Cardíacos/anatomía & histología , Complicaciones Posoperatorias/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Tabique Interventricular/anatomía & histología , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Toma de Decisiones Clínicas , Ecocardiografía , Femenino , Prótesis Valvulares Cardíacas , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Tomografía Computarizada Multidetector , Tamaño de los Órganos , Factores de Riesgo , Tabique Interventricular/diagnóstico por imagen
8.
Ann Hepatobiliary Pancreat Surg ; 23(4): 392-396, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31825007

RESUMEN

BACKGROUNDS/AIMS: Pancreatic leak and fistula formation following pancreatic resection is a dreaded complication associated with significant morbidity and mortality. The perioperative use of inotropes has been implicated in anastomotic dehiscence in other types of gastrointestinal surgery but their impact in pancreatic surgery remains unclear and a potentially modifiable risk factor for pancreatic leak. This study aims to assess the impact of perioperative inotrope infusion on the incidence of pancreatic leak following pancreaticoduodenectomy. METHODS: Retrospective data analysis of all patients undergoing pancreaticoduodenectomy at a tertiary HPB institute. Multivariate analysis and regression models assessed the impact of inotrope use against other known risk factors such as pancreatic duct size and gland texture. Pancreatic fistulae were graded as per ISGPF as Grade A (biochemical leak), Grade B and Grade C fistula. RESULTS: One-hundred and twenty-three (123) patients were included. A total of 52 patients (42%) developed a leak (29 grade A, 15 grade B, and 8 Grade C). In the fistula group, 28 patients (55%) received perioperative inotropes compared to 26 (35%) in the no fistula group. On univariate analysis, patients receiving inotropes (p=0.04) and patients with a soft pancreatic texture (p=0.003) had a statistically higher incidence of developing a pancreatic fistula of any grade. On multivariate analysis, only inotrope use was associated with an increased risk of developing a pancreatic fistula of any grade (OR 2.46, p=0.026), independent of pancreatic texture and pancreatic duct size. CONCLUSIONS: Perioperative inotrope use is associated with an increase incidence of pancreatic leak following pancreaticoduodenectomy and should therefore be used judiciously.

11.
Catheter Cardiovasc Interv ; 94(3): 376-377, 2019 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-31622006

RESUMEN

Retroperitoneal hemorrhage (RPH) and other femoral artery access site complications are associated with "high" arterial punctures. Using the nadir of inferior epigastric artery (IEA) as the landmark for identifying the inguinal ligament and high punctures can reduce access site complications. Traditional teaching of aiming for the middle of the femoral head while obtaining femoral access can result in higher than desired puncture site more frequently than aiming for the lower quarter. Enhanced understanding of anatomical landmarks, use of imaging guidance and strict adherence to safe access practices can help improve outcomes.


Asunto(s)
Cateterismo Cardíaco , Arteria Femoral , Angiografía , Punciones , Resultado del Tratamiento
15.
Catheter Cardiovasc Interv ; 93(6): 1095-1096, 2019 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-31025524

RESUMEN

Repeat surgery is the ideal choice for degenerated bioprosthetic mitral valves. Percutaneous valve-in-valve (ViV) replacement for the treatment of degenerated bioprostheses has emerged as an alternative to open surgery in patients who are at high risk of surgical complications. Joseph et al have described the feasibility and long-term outcomes of Melody ViV Implantation for bioprosthetic mitral valve dysfunction in high-risk population.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Cateterismo Cardíaco , Humanos , Válvula Mitral/cirugía , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
16.
Catheter Cardiovasc Interv ; 93(3): 530-531, 2019 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-30770668

RESUMEN

The anatomic interplay between aortic valve, ascending aorta, left ventricular outflow tract and peripheral vasculature play a major role in determining device related outcomes in transcatheter aortic valve replacement. Factors such as the alignment angle (prosthesis-ascending aorta), pre-dilatation, operating team experience and chronic kidney disease may play a role in valve displacement. Careful analysis of all imaging modalities while sizing and selecting a valve type, and attention to newer deployment techniques may improve outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Ego , Humanos , Diseño de Prótesis
17.
Catheter Cardiovasc Interv ; 92(7): 1412-1413, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-30548182

RESUMEN

Use of bioprosthetic implants for surgical aortic valve replacements (SAVR) has been increasing in the recent years Surgical redo AVRs for failed surgical aortic bioprostheses have been traditionally considered the standard practice; however, in patients with higher surgical risk scores, transcatheter valve-in-valve aortic valve replacements are being commonly performed There is scarcity of data comparing these two approaches in this complex patient cohort Available data suggest that transcatheter ViV aortic valve replacement is generally a safe approach once some caveats are accounted for.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Humanos , Resultado del Tratamiento
18.
J Interv Cardiol ; 31(6): 907-915, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30168203

RESUMEN

OBJECTIVES: We report our multicenter experience on continuous hemodynamic monitoring using exclusively the steerable guide catheter (SGC) during MitraClip repair. BACKGROUND: Left atrial pressure (LAP) and V-wave are useful to evaluate MitraClip repair but no simple method of continuous monitoring exists. METHODS: From 11/2016 to 8/2017, 74 patients from four centers with symptomatic moderate-severe to severe mitral regurgitation (MR), underwent MitraClip NT repair with continuous hemodynamic monitoring via the SGC. Real-time LAP/V-wave changes were compared with transesophageal echocardiography (TEE). When mitral stenosis was suspected, transmitral gradients were verified by invasive hemodynamics. Clinical and echocardiographic outcomes were determined. RESULTS: Mean age was 78 ± 10 years and STS score 9.1 ± 11.0%. Pathology included leaflet prolapse/flail (45%), restriction (35%), and mixed (20%). Number of clips averaged 1.7 ± 0.7 per case. There was a significant reduction in LAP (21 ± 10 to 15 ± 7 mmHg, P < 0.0001) and V-wave(37 ± 19 to 24 ± 10 mmHg, P < 0.0001) post MitraClip, but the decrease was less in patients with atrial fibrillation (P < 0.05). Transmitral gradient significantly increased from 2.0 ± 1.2 to 4.0 ± 1.7 mmHg (P < 0.0001). Paradoxical increases in LAP and V-wave despite MR reduction were observed in three cases requiring MitraClip repositioning or retrieval to avoid stenosis. Follow-up averaged 5.0 ± 2.9 months and was 100% complete. KCCQ improvement was significant and MR reduction to <1+ was 67% and <2+ was 93% at 30 days. CONCLUSIONS: Continuous hemodynamic monitoring using the SGC complements TEE to assess and optimize MitraClip repair in real-time. Further validation is necessary but this feature may be part of future MitraClip and other transcatheter mitral repair systems.


Asunto(s)
Cateterismo Cardíaco/métodos , Monitorización Hemodinámica/métodos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Ecocardiografía Transesofágica/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Sistema de Registros , Estudios Retrospectivos , Instrumentos Quirúrgicos/efectos adversos , Resultado del Tratamiento
19.
Heart ; 104(24): 2044-2050, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30030334

RESUMEN

OBJECTIVE: The prevalence of heart failure (HF) among adult patients with congenital heart disease (ACHD) is rising. Right ventricle (RV) exercise reserve and its relationship to outcomes have not been characterised. We aim to evaluate the prognostic impact of impaired RV reserve in an ACHD population referred for cardiopulmonary exercise testing (CPET). METHODS: This retrospective study evaluates patients with ACHD who underwent CPET (n=147) with first-pass radionuclide ventriculography at a single tertiary care centre. RV reserve was categorised as normal, mild to moderately or severely impaired. The primary composite clinical outcome included clinical right HF, arrhythmia, transplantation or death. RESULTS: Patients were median age 41±13 years, 50% were female and median follow-up was 1.1 (IQR: 0.7-2.0) years. Exercise RV reserve was impaired in 103 patients (70%), of whom 32% were asymptomatic. Resting RV systolic function poorly predicted RV reserve, with 52% of patients with severe impairment having a qualitatively normal echocardiographic assessment. The severely impaired reserve group had lower peak oxygen consumption (VO2)(17.2 vs 22.5 mL/kg/min, p<0.0001) compared with the normal reserve group, and was more likely to develop the composite outcome (48% vs 9%, log-rank p<0.001). Severely impaired RV reserve predicted event-free survival after adjusting for peak VO2, age, sex, RV pathology, QRS duration, New York Heart Association class, resting RV ejection fraction and RV dilation by echocardiography or MRI (HR 3.7, 95% CI 1.1 to 13.0, p=0.039). CONCLUSION: Impaired RV reserve, occurred in asymptomatic patients, was not well predicted by resting systolic function assessment, and strongly predicted adverse cardiovascular outcomes.


Asunto(s)
Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/fisiopatología , Volumen Sistólico/fisiología , Función Ventricular Derecha/fisiología , Adulto , Ecocardiografía , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Pronóstico , Estudios Retrospectivos
20.
Catheter Cardiovasc Interv ; 91(7): 1210-1211, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29894590

RESUMEN

The results of overlapping metallic stents have been concerning but this practice is often unavoidable in the setting of long or tortuous lesions, diameter discrepancy of proximal and distal vessel, and for residual dissections. Theoretically, bio-absorbable scaffolds may carry an advantage over metallic stents due to the progressive resorption of the scaffold theoretically rendering the overlap a non-issue; this has not been clinically evident. Since stent/scaffold overlap cannot be entirely avoided, improved stent delivery/deployment and scaffold design modification may reduce complications in this complex patient subset.


Asunto(s)
Implantes Absorbibles , Stents Liberadores de Fármacos , Everolimus , Humanos , Stents , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA