Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Cureus ; 16(8): e66885, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39280472

RESUMEN

Ocular myasthenia gravis (OMG) is a neuromuscular disease characterized by the production of autoantibodies against post-synaptic proteins at the neuromuscular junction (NMJ). An 18-year-old male who had symptoms of drooping eyelids and double vision was diagnosed with ocular myasthenia gravis on investigations and examinations. Treatment was initiated with a tablet of pyridostigmine 60 mg twice daily per oral for two weeks, followed by three times daily for four weeks. The patient demonstrated significant improvement in ptosis and diplopia. There are still a considerable number of challenges in the diagnosis and treatment of ocular myasthenia gravis, with the typical treatment involving acetylcholinesterase inhibitors and immunosuppressants.

2.
Cureus ; 16(6): e61993, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38983996

RESUMEN

Objective The objective of this study was to compare K1, K2, Kmax, and pachymetry values from Pentacam and Galilei scans of corneal topography in order to assess their correlation and interchangeability in clinical practice. Methodology A total of 34 patients (68 eyes) were enrolled in the study. Corneal topography was performed using Pentacam and Galilei devices on the same day. K1, K2, Kmax, and pachymetry readings were obtained from the scans and analyzed using paired t-tests and Bland-Altman plots. Results There were minimal differences in clinical settings between Pentacam and Galilei for K1, K2, Kmax (>0.75 D), and pachymetry values (>15 um). However, there was a statistically significant difference found between Kmax and pachymetry, making their interchangeability questionable. Conclusion Pentacam and Galilei demonstrate a good correlation between corneal keratometric values (K1, K2, and Kmax) and pachymetry values in clinical settings, and they should be used interchangeably with caution.

3.
Cureus ; 15(6): e41100, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37519538

RESUMEN

Purtscher retinopathy (PR) is an occlusive vasculopathy of the retinal microvasculature that classically presents 24-48 hours after compressive chest trauma. Symptoms vary from mild to severe acute visual loss. Characteristic findings on fundus examination such as Purtscher flecken, cotton wool spots, and retinal hemorrhages may also be found. Here, we discuss a case of Purtscher retinopathy due to compressive chest trauma.

4.
Cureus ; 15(5): e38371, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37265880

RESUMEN

Microspherophakia is a rare congenital anomaly characterized by an abnormally small and spherical crystalline lens, which can be associated with several systemic syndromes. We present an extremely rare case of bilateral anteriorly displaced microspherophakia in a female child with Marfanoid habitus. The patient displayed phenotypic features resembling Marfan syndrome, including tall stature, muscle hypotonia, dolichostenomelia, and increased arm span than body length. However, unlike Marfan syndrome, Marfanoid habitus is not associated with mutations in the fibrillin-1 gene. The association between microspherophakia and Marfanoid habitus is a unique presentation that has not been reported in the literature. This case report aims to increase awareness of microspherophakia as a possible ocular association of Marfanoid habitus.

5.
Cureus ; 14(10): e30747, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36457596

RESUMEN

Introduction Color vision testing was first seen as a parameter to be tested in the 1700s. Nowadays, it is a well-known phenomenon with significant quality-of-life implications. Structures involved in color vision include the lens, pupil, retinal cone photopigments, and several photoreceptor processes that translate the incoming spectrum of different light wavelengths into a processed colored image. An initial color vision assessment was made simply by comparing the color perception of the individual to that of the examiner. The most commonly used tools to screen for color vision defects today are color plates, such as the Ishihara color plates. In the modern age, smartphones have evolved to become an essential part of our everyday lives with applications such as Eye Handbook, which allow easier access to color vision testing using color plates displayed on smartphone screens. In this study, we compared color vision testing on Android and iOS devices to the standard Ishihara booklet. Materials and methods A cross-sectional validation study was performed on patients presenting to the Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan for six months. The sample size collected was 162 with a 95% confidence interval. The age range of the sample population was kept at 12-70 years. A patient was selected for participation in the study, and a color vision assessment was performed using the Ishihara color plates and Android and iOS smartphones. The collected data was then entered into IBM SPSS (Statistical Package for the Social Sciences) Statistics 25 for analysis, with the p-value being kept at 0.05. Results The sample size was 162, with the gender distribution being predominantly male (69.14%). The average age of the participants was 35.94 (SD = 12.04). The result of the two-tailed paired sample z-testwas not significant based on a p-value of 0.565, indicating the null hypothesis cannot be rejected. This finding suggests the difference between the mean of Ishihara and the mean of the iPhone was not significantly different from zero. Similar results were found for comparisons between Android smartphones and the Ishihara booklet. Conclusions Previous studies conducted showed nearly 60% of subjects with normal color vision correctly identified all colors on standard Ishihara color plates. The two-tailed paired sample t-test conducted in our study showed no significant difference between either of the smartphone groups (iPhone or Android) and the Ishihara booklet group, indicating that smartphones present a viable alternative to standard Ishihara booklet testing. However, there are certain limitations to our study. Different types of smartphone screens present a challenge in standardization while testing color vision, something that is not a problem when using the Ishihara booklet. However, smartphones are more widely available, more versatile, and present far greater ease of access. Both these factors should be considered when comparing the two in future studies.

6.
Cureus ; 14(8): e28048, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36127994

RESUMEN

Ocular coloboma is a rare congenital anomaly that arises due to an abnormality in embryogenesis. It occurs due to failed fusion of the embryonic fissure resulting in a persistent defect. Colobomas may present with vision loss but are most commonly asymptomatic and diagnosed incidentally. In this article, we present a case of asymptomatic chorioretinal coloboma diagnosed on routine screening. The patient was managed with prophylactic argon laser retinopexy to prevent complications leading to visual impairment in the future.

7.
Cureus ; 14(5): e25128, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35733478

RESUMEN

Axenfeld-Rieger syndrome (ARS) is a rare autosomal dominant condition characterized by the dysgenesis of the anterior segment along with some systemic abnormalities such as dental and facial bone defects. Its incidence is thought to be 1 in 200,000. Treatment is predominantly the management of glaucoma and is mostly medical but can be surgical in refractory cases. Here, we describe the case of a 35-year-old female patient who presented with co-existing vernal keratoconjunctivitis and ARS. The treatment was more challenging as we had to manage two conditions simultaneously.

8.
Cureus ; 14(12): e32094, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36601199

RESUMEN

Introduction Standard automated perimetry (SAP) is the gold standard of visual field assessment in patients with neuro-ophthalmic conditions. Glaucoma is a progressive optic neuropathy characterized by damage to the ganglion cell complex with corresponding visual field defects and intraocular pressure (IOP) being the only modifiable ocular risk factor. Recent advances in technology have paved the way for remote screening and monitoring of visual field defects with the aid of a computer or tablet-based software. One such personal computer (PC)-based software is 'Specvis', which has shown promising reliability as compared to SAP. The primary objective of this study was to compare Specvis and Humphrey Field Analyzer (HFA) visual field reports in the graphical domain while secondary objectives were to estimate the ease of use of Specvis in comparison to HFA and comparison of test duration between Specvis and HFA.  Materials and methods This was a cross-sectional validation study performed at a tertiary care ophthalmology institute in Rawalpindi, Pakistan. Subjects presenting to the outpatient department were recruited based on consecutive sampling technique and were divided into healthy and diseased groups. Basic data collection instrument after informed consent was filled with demographic data, ophthalmic data, disease condition, and attached with analysis reports of both HFA and Specvis for assessment by three senior ophthalmology consultants independently. A total of 218 eyes of 109 subjects were included in this pilot study. SAP was done on the VF 30-2 program using HFA 3. The same patient then performed the visual field assessment on a PC with Specvis installed and settings adjusted to match the VF 30-2 program of HFA as closely as possible. Visual fields of a subject obtained from HFA and Specvis were then coupled and sent to three different senior ophthalmologists. The assessment was done by comparing the greyscale visual field printouts in the graphical domain and scored based on a 5-point Likert scale which were then analyzed for inter-observer reliability. After each test, all subjects were asked to rate the difficulty level of performing the test on HFA and Specvis based on a 5-point Likert scale. The duration of the test performed on HFA and Specvis was also noted for comparison. Results We observed male preponderance in our study participants (n=128, 58.72%). The majority of the participants were non-diseased (n=170, 77.98%) while advanced glaucoma was the commonest disease in the diseased group (n = 22, 10.09%). The mean age of the participants was 40.71 (SD=15.24). The observations for the HFA test duration had an average of 213.33 seconds (SD=33.49, Min=174.00, Max=314.00) while the Specvis test duration had an average of 267.36 seconds (SD=35.98, Min=228.00, Max=370.00). A significant positive correlation was observed between score 1, score 2, and score 3 given by the three ophthalmologists. A significant negative correlation was observed between ease of using HFA and age, with a correlation of -.28. A significant negative correlation was also observed between ease of using Specvis and age. Conclusion Specvis, a computer-based free open-source software used in our study, can give promising results in diagnosing as well as monitoring the progression of visual field defects. It can act as a significantly cost-effective and readily available bridge between visual field examination by confrontation method and SAP.

9.
Cureus ; 13(4): e14672, 2021 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-34055519

RESUMEN

Large ovarian tumours are rare. Various diagnostic modalities are used to help in confirming the size and type of ovarian tumours. Laparotomy in a lateral decubitus position under general anaesthesia is the most common treatment approach. Here we present a case of a 17-year-old unmarried girl from whom a 13 kg ovarian tumor was resected. We highlight in this case report the mental stress that a patient goes through when accused of having an extramarital pregnancy by the community in a conservative society like ours. Furthermore, the importance of psychological support and counselling is paramount.

10.
Cureus ; 12(11): e11557, 2020 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-33364085

RESUMEN

Migrainous infarction is a complication of migraine that accounts for 0.5-1.5% of all cerebral infarcts, usually seen in the posterior circulation and in young women. In this case report, we report a case of a right-sided middle cerebral artery ischemic stroke in a young male presenting with migraine, photophobia and phonophobia lasting for more than 60 minutes and followed by ipsilateral hemiparesis, which is a very unusual presentation. The provisional diagnosis of ischemic infarction of the right middle cerebral artery was made that was confirmed on radio imaging. A high index of suspicion is always required while dealing with patients with migraine especially in atypical presentations as in this case.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA