Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 123
1.
ACS Nano ; 18(19): 12025-12048, 2024 May 14.
Article En | MEDLINE | ID: mdl-38706306

Cardiac interfacing devices are essential components for the management of cardiovascular diseases, particularly in terms of electrophysiological monitoring and implementation of therapies. However, conventional cardiac devices are typically composed of rigid and bulky materials and thus pose significant challenges for effective long-term interfacing with the curvilinear surface of a dynamically beating heart. In this regard, the recent development of intrinsically soft bioelectronic devices using nanocomposites, which are fabricated by blending conductive nanofillers in polymeric and elastomeric matrices, has shown great promise. The intrinsically soft bioelectronics not only endure the dynamic beating motion of the heart and maintain stable performance but also enable conformal, reliable, and large-area interfacing with the target cardiac tissue, allowing for high-quality electrophysiological mapping, feedback electrical stimulations, and even mechanical assistance. Here, we explore next-generation cardiac interfacing strategies based on soft bioelectronic devices that utilize elastic conductive nanocomposites. We first discuss the conventional cardiac devices used to manage cardiovascular diseases and explain their undesired limitations. Then, we introduce intrinsically soft polymeric materials and mechanical restraint devices utilizing soft polymeric materials. After the discussion of the fabrication and functionalization of conductive nanomaterials, the introduction of intrinsically soft bioelectronics using nanocomposites and their application to cardiac monitoring and feedback therapy follow. Finally, comments on the future prospects of soft bioelectronics for cardiac interfacing technologies are discussed.


Nanostructures , Humans , Nanostructures/chemistry , Cardiovascular Diseases/therapy , Electric Conductivity , Polymers/chemistry , Animals , Nanocomposites/chemistry , Heart/physiology
2.
Sci Adv ; 10(12): eadi7724, 2024 Mar 22.
Article En | MEDLINE | ID: mdl-38507496

Stretchable bioelectronics has notably contributed to the advancement of continuous health monitoring and point-of-care type health care. However, microscale nonconformal contact and locally dehydrated interface limit performance, especially in dynamic environments. Therefore, hydrogels can be a promising interfacial material for the stretchable bioelectronics due to their unique advantages including tissue-like softness, water-rich property, and biocompatibility. However, there are still practical challenges in terms of their electrical performance, material homogeneity, and monolithic integration with stretchable devices. Here, we report the synthesis of a homogeneously conductive polyacrylamide hydrogel with an exceptionally low impedance (~21 ohms) and a reasonably high conductivity (~24 S/cm) by incorporating polyaniline-decorated poly(3,4-ethylenedioxythiophene:polystyrene). We also establish robust adhesion (interfacial toughness: ~296.7 J/m2) and reliable integration between the conductive hydrogel and the stretchable device through on-device polymerization as well as covalent and hydrogen bonding. These strategies enable the fabrication of a stretchable multichannel sensor array for the high-quality on-skin impedance and pH measurements under in vitro and in vivo circumstances.


Hydrogels , Hydrogels/chemistry , Electric Impedance , Electric Conductivity , Polymerization , Hydrogen Bonding
3.
ACS Nano ; 18(2): 1241-1256, 2024 Jan 16.
Article En | MEDLINE | ID: mdl-38166167

High-performance robotic vision empowers mobile and humanoid robots to detect and identify their surrounding objects efficiently, which enables them to cooperate with humans and assist human activities. For error-free execution of these robots' tasks, efficient imaging and data processing capabilities are essential, even under diverse and complex environments. However, conventional technologies fall short of meeting the high-standard requirements of robotic vision under such circumstances. Here, we discuss recent progress in artificial vision systems with high-performance imaging and data processing capabilities enabled by distinctive electrical, optical, and mechanical characteristics of nanomaterials surpassing the limitations of traditional silicon technologies. In particular, we focus on nanomaterial-based electronic eyes and in-sensor processing devices inspired by biological eyes and animal visual recognition systems, respectively. We provide perspectives on key nanomaterials, device components, and their functionalities, as well as explain the remaining challenges and future prospects of the artificial vision systems.


Nanostructures , Robotics , Animals , Humans , Vision, Ocular , Electronics , Biomimetics/methods
4.
Sci Rep ; 14(1): 1393, 2024 01 16.
Article En | MEDLINE | ID: mdl-38228674

Skin electronics, facilitating a high-quality interface between external devices and human skin for recording physiological and/or electrophysiological signals as well as delivering external electrical and/or mechanical energy into the human body, has shown significant progress. However, achieving mechanically conformal contact and electrically low contact resistance at the device-skin interface remains challenging. Here, we propose a material strategy to potentially address such an issue by using phase separation of silver nanowires and silver nanoparticles (Ag NWs and Ag NPs) within a stretchable conductive nanocomposite (NC). This phase-separated NC ensures low contact resistance and high conductivity, which are key requirements in skin electronics, while maintaining excellent mechanical contact with the skin. To achieve phase separation, we hydrophobically treated the surfaces of Ag NWs and Ag NPs. Then, as the NC solidified, the solvent contained in the NC was slowly evaporated to sufficiently precipitate Ag NPs within the NC. As a result, the phase-separated NC exhibited high conductivity (~ 18,535 S cm-1), excellent stretchability (~ 80%), and low contact resistance on both the top and bottom NC surfaces (average ~ 0.132 Ω). The phase-separated NC has enabled implementation of high performance skin-mounted devices, including strain sensors, electrophysiological sensors, and a wearable heater.


Metal Nanoparticles , Nanocomposites , Nanowires , Wearable Electronic Devices , Humans , Silver , Electronics
5.
Chem Rev ; 124(3): 768-859, 2024 Feb 14.
Article En | MEDLINE | ID: mdl-38241488

Optoelectronic devices with unconventional form factors, such as flexible and stretchable light-emitting or photoresponsive devices, are core elements for the next-generation human-centric optoelectronics. For instance, these deformable devices can be utilized as closely fitted wearable sensors to acquire precise biosignals that are subsequently uploaded to the cloud for immediate examination and diagnosis, and also can be used for vision systems for human-interactive robotics. Their inception was propelled by breakthroughs in novel optoelectronic material technologies and device blueprinting methodologies, endowing flexibility and mechanical resilience to conventional rigid optoelectronic devices. This paper reviews the advancements in such soft optoelectronic device technologies, honing in on various materials, manufacturing techniques, and device design strategies. We will first highlight the general approaches for flexible and stretchable device fabrication, including the appropriate material selection for the substrate, electrodes, and insulation layers. We will then focus on the materials for flexible and stretchable light-emitting diodes, their device integration strategies, and representative application examples. Next, we will move on to the materials for flexible and stretchable photodetectors, highlighting the state-of-the-art materials and device fabrication methods, followed by their representative application examples. At the end, a brief summary will be given, and the potential challenges for further development of functional devices will be discussed as a conclusion.

6.
Adv Healthc Mater ; : e2303563, 2023 Dec 20.
Article En | MEDLINE | ID: mdl-38117136

Soft bioelectronic technologies for neuroengineering have shown remarkable progress, which include novel soft material technologies and device design strategies. Such technological advances that are initiated from fundamental brain science are applied to clinical neuroscience and provided meaningful promises for significant improvement in the diagnosis efficiency and therapeutic efficacy of various brain diseases recently. System-level integration strategies in consideration of specific disease circumstances can enhance treatment effects further. Here, recent advances in soft implantable bioelectronics for neuroengineering, focusing on materials and device designs optimized for the treatment of intracranial disease environments, are reviewed. Various types of soft bioelectronics for neuroengineering are categorized and exemplified first, and then details for the sensing and stimulating device components are explained. Next, application examples of soft implantable bioelectronics to clinical neuroscience, particularly focusing on the treatment of brain tumor and epilepsy are reviewed. Finally, an ideal system of soft intracranial bioelectronics such as closed-loop-type fully-integrated systems is presented, and the remaining challenges for their clinical translation are discussed.

7.
ACS Nano ; 17(20): 20013-20023, 2023 10 24.
Article En | MEDLINE | ID: mdl-37787474

Mechanically deformable photodetectors (PDs) are key device components for wearable health monitoring systems based on photoplethysmography (PPG). Achieving high detectivity, fast response time, and an ultrathin form factor in the PD is highly needed for next-generation wearable PPG systems. Self-powered operation without a bulky power-supply unit is also beneficial for point-of-care application. Here, we propose ultrathin self-powered PDs using heavy-metal-free Cu-In-Se quantum dots (QDs), which enable high-performance wearable PPG systems. Although the light-absorbing QD layer is extremely thin (∼40 nm), the developed PD exhibits excellent performance (specific detectivity: 2.10 × 1012 Jones, linear dynamic range: 102 dB, and spectral range: 250-1050 nm at zero bias), which is comparable to that of conventional rigid QD-PDs employing thick Pb-chalcogenide QD layers. This is attributed to material and device strategies─materials that include Cu-In-Se QDs, a MoS2-nanosheet-blended poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) hole transport layer, a ZnO nanoparticle electron transport layer, Ag and ITO electrodes, and an ultrathin form factor (∼120 nm except the electrodes) that enable excellent mechanical deformability. These allow the successful application of QD-PDs to a wearable system for real-time PPG monitoring, expanding their potential in the field of mobile bioelectronics.


Metals, Heavy , Nanoparticles , Quantum Dots , Wearable Electronic Devices , Electric Power Supplies , Electrodes
8.
Adv Mater ; 35(52): e2306092, 2023 Dec.
Article En | MEDLINE | ID: mdl-37739451

Conversion of sunlight and organic carbon substrates to sustainable energy sources through microbial metabolism has great potential for the renewable energy industry. Despite recent progress in microbial photosynthesis, the development of microbial platforms that warrant efficient and scalable fuel production remains in its infancy. Efficient transfer and retrieval of gaseous reactants and products to and from microbes are particular hurdles. Here, inspired by water lily leaves floating on water, a microbial device designed to operate at the air-water interface and facilitate concomitant supply of gaseous reactants, smooth capture of gaseous products, and efficient sunlight delivery is presented. The floatable device carrying Rhodopseudomonas parapalustris, of which nitrogen fixation activity is first determined through this study, exhibits a hydrogen production rate of 104 mmol h-1  m-2 , which is 53 times higher than that of a conventional device placed at a depth of 2 cm in the medium. Furthermore, a scaled-up device with an area of 144 cm2 generates hydrogen at a high rate of 1.52 L h-1  m-2 . Efficient nitrogen fixation and hydrogen generation, low fabrication cost, and mechanical durability corroborate the potential of the floatable microbial device toward practical and sustainable solar energy conversion.

9.
Adv Mater ; 35(44): e2303458, 2023 Nov.
Article En | MEDLINE | ID: mdl-37591512

Stretchable conductive nanocomposites have been intensively studied for wearable bioelectronics. However, development of nanocomposites that simultaneously feature metal-like conductivity(> 100 000 S cm-1 ) and high stretchability (> 100%) for high-performance skin-mountable devices is still extremely challenging. Here a material strategy for such a nanocomposite is presented by using local bundling of silver nanowires stabilized with dual ligands (i.e., 1-propanethiols and 1-decanethiols). When the nanocomposite is solidified via solvent evaporation under a highly humid condition, the nanowires in the organic solution are bundled and stabilized. The resulting locally-bundled nanowires lower contact resistance while maintain their percolation network, leading to high conductivity. Dual ligands of 1-propanethiol and 1-decanethiol further boost up the conductivity. As a result, a nanocomposite with both high conductivity of ≈122,120 S cm-1 and high stretchability of ≈200% is obtained. Such superb electrical and mechanical properties are critical for various applications in skin-like electronics, and herein, a wearable thermo-stimulation device is demonstrated.

10.
Small Methods ; 7(9): e2300032, 2023 09.
Article En | MEDLINE | ID: mdl-37199695

Despite advances in a wide range of device applications of hydrogels, including implantable ones, a method for deploying patterned hydrogel devices into the body in a minimally-invasive manner is not available yet. However, in situ patterning of the hydrogel in vivo has an obvious advantage, by which incision surgery for implantation of the hydrogel device can be avoided. Here, a minimally-invasive and in vivo hydrogel patterning method for in situ fabrication of implantable hydrogel devices is presented. The sequential application of injectable hydrogels and enzymes, with assistance of minimally-invasive surgical instruments, enables the in vivo and in situ hydrogel patterning. This patterning method can be achieved by adopting an appropriate combination of the sacrificial mold hydrogel and the frame hydrogel, in consideration of unique material properties of the hydrogels such as high softness, facile mass transfer, biocompatibility, and diverse crosslinking mechanisms. In vivo and in situ patterning of the hydrogels functionalized with nanomaterials is also demonstrated to fabricate the wireless heater and tissue scaffold, showcasing broad applicability of the patterning method.


Hydrogels , Tissue Engineering , Tissue Engineering/methods , Tissue Scaffolds
11.
Nat Nanotechnol ; 18(7): 754-762, 2023 Jul.
Article En | MEDLINE | ID: mdl-37106047

Storing solar energy in chemical bonds aided by heterogeneous photocatalysis is desirable for sustainable energy conversion. Despite recent progress in designing highly active photocatalysts, inefficient solar energy and mass transfer, the instability of catalysts and reverse reactions impede their practical large-scale applications. Here we tackle these challenges by designing a floatable photocatalytic platform constructed from porous elastomer-hydrogel nanocomposites. The nanocomposites at the air-water interface feature efficient light delivery, facile supply of water and instantaneous gas separation. Consequently, a high hydrogen evolution rate of 163 mmol h-1 m-2 can be achieved using Pt/TiO2 cryoaerogel, even without forced convection. When fabricated in an area of 1 m2 and incorporated with economically feasible single-atom Cu/TiO2 photocatalysts, the nanocomposites produce 79.2 ml of hydrogen per day under natural sunlight. Furthermore, long-term stable hydrogen production in seawater and highly turbid water and photoreforming of polyethylene terephthalate demonstrate the potential of the nanocomposites as a commercially viable photocatalytic system.

12.
ACS Nano ; 17(8): 7550-7561, 2023 04 25.
Article En | MEDLINE | ID: mdl-37039606

Mechanically soft metallic nanocomposites have gained much attention as a key material for intrinsically stretchable biointegrated devices. However, it has been challenging to develop a stretchable conductive nanocomposite with all the desired material characteristics including high conductivity, high stretchability, low cytotoxicity, and low impedance. Here, we present a material strategy for the stretchable conductive nanocomposite, particularly emphasizing low impedance, by combining silver-gold-platinum core-shell-shell nanowires and homogeneously dispersed in situ synthesized platinum nanoparticles (Pt NPs). The highly embossed structure of the outermost Pt shell, together with the intrinsic electrical property of Pt, contributes to minimizing the impedance. The gold-platinum double-layer sheath prevents leaching of cytotoxic Ag ions, thus improving biocompatibility. Homogeneously dispersed Pt NPs, synthesized in situ during fabrication of the nanocomposite, simultaneously enhance conductivity, reduce impedance, and improve stretchability by supporting the percolation network formation. This intrinsically stretchable nanocomposite conductor can be applied to wearable and implantable bioelectronics for recording biosignals and delivering electrical stimulations in vivo.


Metal Nanoparticles , Nanowires , Wearable Electronic Devices , Nanowires/chemistry , Electric Impedance , Metal Nanoparticles/chemistry , Platinum , Gold/chemistry
13.
ACS Nano ; 17(6): 5435-5447, 2023 03 28.
Article En | MEDLINE | ID: mdl-36926815

Postsurgical treatment of glioblastoma multiforme (GBM) by systemic chemotherapy and radiotherapy is often inefficient. Tumor cells infiltrating deeply into the brain parenchyma are significant obstacles to the eradication of GBM. Here, we present a potential solution to this challenge by introducing an injectable thermoresponsive hydrogel nanocomposite. As a liquid solution that contains drug-loaded micelles and water-dispersible ferrimagnetic iron oxide nanocubes (wFIONs), the hydrogel nanocomposite is injected into the resected tumor site after surgery. It promptly gelates at body temperature to serve as a soft, deep intracortical drug reservoir. The drug-loaded micelles target residual GBM cells and deliver drugs with a minimum premature release. Alternating magnetic fields accelerate diffusion through heat generation from wFIONs, enabling penetrative drug delivery. Significantly suppressed tumor growth and improved survival rates are demonstrated in an orthotopic mouse GBM model. Our system proves the potential of the hydrogel nanocomposite platform for postsurgical GBM treatment.


Brain Neoplasms , Glioblastoma , Nanocomposites , Animals , Mice , Hydrogels/therapeutic use , Micelles , Drug Delivery Systems , Brain Neoplasms/drug therapy , Brain Neoplasms/surgery , Glioblastoma/drug therapy , Glioblastoma/surgery , Nanocomposites/therapeutic use , Cell Line, Tumor
14.
Sci Adv ; 9(13): eadf6856, 2023 03 31.
Article En | MEDLINE | ID: mdl-37000879

The implantable cardioverter-defibrillator (ICD) is an effective method to prevent sudden cardiac death in high-risk patients. However, the transvenous lead is incompatible with large-area electrophysiological mapping and cannot accommodate selective multichannel precision stimulations. Moreover, it involves high-energy shocks, resulting in pain, myocardial damage, and recurrences of ventricular tachyarrhythmia (VTA). We present a method for VTA treatment based on subthreshold electrical stimulations using a stretchable epicardial multichannel electrode array, which does not disturb the normal contraction or electrical propagation of the ventricle. In rabbit models with myocardial infarction, the infarction was detected by mapping intracardiac electrograms with the stretchable epicardial multichannel electrode array. Then, VTAs could be terminated by sequential electrical stimuli from the epicardial multichannel electrode array beginning with low-energy subthreshold stimulations. Last, we used these subthreshold stimulations to prevent the occurrence of additional VTAs. The proposed protocol using the stretchable epicardial multichannel electrode array provides opportunities toward the development of innovative methods for painless ICD therapy.


Defibrillators, Implantable , Myocardial Infarction , Tachycardia, Ventricular , Rabbits , Animals , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/etiology , Defibrillators, Implantable/adverse effects , Heart Ventricles , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/epidemiology , Myocardial Infarction/therapy , Myocardial Infarction/etiology
15.
ACS Nano ; 17(6): 5211-5295, 2023 03 28.
Article En | MEDLINE | ID: mdl-36892156

Humans rely increasingly on sensors to address grand challenges and to improve quality of life in the era of digitalization and big data. For ubiquitous sensing, flexible sensors are developed to overcome the limitations of conventional rigid counterparts. Despite rapid advancement in bench-side research over the last decade, the market adoption of flexible sensors remains limited. To ease and to expedite their deployment, here, we identify bottlenecks hindering the maturation of flexible sensors and propose promising solutions. We first analyze challenges in achieving satisfactory sensing performance for real-world applications and then summarize issues in compatible sensor-biology interfaces, followed by brief discussions on powering and connecting sensor networks. Issues en route to commercialization and for sustainable growth of the sector are also analyzed, highlighting environmental concerns and emphasizing nontechnical issues such as business, regulatory, and ethical considerations. Additionally, we look at future intelligent flexible sensors. In proposing a comprehensive roadmap, we hope to steer research efforts towards common goals and to guide coordinated development strategies from disparate communities. Through such collaborative efforts, scientific breakthroughs can be made sooner and capitalized for the betterment of humanity.


Wearable Electronic Devices , Humans , Quality of Life
16.
ACS Omega ; 8(6): 5209-5224, 2023 Feb 14.
Article En | MEDLINE | ID: mdl-36816688

With the advance in information technologies involving machine vision applications, the demand for energy- and time-efficient acquisition, transfer, and processing of a large amount of image data has rapidly increased. However, current architectures of the machine vision system have inherent limitations in terms of power consumption and data latency owing to the physical isolation of image sensors and processors. Meanwhile, synaptic optoelectronic devices that exhibit photoresponse similar to the behaviors of the human synapse enable in-sensor preprocessing, which makes the front-end part of the image recognition process more efficient. Herein, we review recent progress in the development of synaptic optoelectronic devices using functional nanomaterials and their unique interfacial characteristics. First, we provide an overview of representative functional nanomaterials and device configurations for the synaptic optoelectronic devices. Then, we discuss the underlying physics of each nanomaterial in the synaptic optoelectronic device and explain related device characteristics that allow for the in-sensor preprocessing. We also discuss advantages achieved by the application of the synaptic optoelectronic devices to image preprocessing, such as contrast enhancement and image filtering. Finally, we conclude this review and present a short prospect.

17.
Sci Robot ; 8(75): eade4698, 2023 02 22.
Article En | MEDLINE | ID: mdl-36791214

With the rise of mobile robotics, including self-driving automobiles and drones, developing artificial vision for high-contrast and high-acuity imaging in vertically uneven illumination conditions has become an important goal. In such situations, balancing uneven illumination, improving image contrast for facile object detection, and achieving high visual acuity in the main visual fields are key requirements. Meanwhile, in nature, cuttlefish (genus Sepia) have evolved an eye optimized for vertically uneven illumination conditions, which consists of a W-shaped pupil, a single spherical lens, and a curved retina with a high-density photoreceptor arrangement and polarized light sensitivity. Here, inspired by the cuttlefish eye, we report an artificial vision system consisting of a W-shaped pupil, a single ball lens, a surface-integrated flexible polarizer, and a cylindrical silicon photodiode array with a locally densified pixel arrangement. The W-shaped pupil integrated on the ball lens balances vertically uneven illumination, and the cylindrical silicon photodiode array integrated with the flexible polarizer enables high-contrast and high-acuity imaging.


Decapodiformes , Robotics , Animals , Lighting , Silicon , Visual Acuity
18.
Sci Adv ; 8(41): eabq3101, 2022 Oct 14.
Article En | MEDLINE | ID: mdl-36223475

Synaptic photodetectors exhibit photon-triggered synaptic plasticity, which thus can improve the image recognition rate by enhancing the image contrast. However, still, the visualization and recognition of invisible ultraviolet (UV) patterns are challenging, owing to intense background noise. Here, inspired by all-or-none potentiation of synapse, we develop an integrated device of synaptic phototransistors (SPTrs) and quantum dot light-emitting diodes (QLEDs), facilitating noise reduction and visualization of UV patterns through on-device preprocessing. The SPTrs convert noisy UV inputs into a weighted photocurrent, which is applied to the QLEDs as a voltage input through an external current-voltage-converting circuit. The threshold switching characteristics of the QLEDs result in amplified current and visible illumination by the suprathreshold input voltage or nearly zero current and no visible illumination by the input voltage below the threshold. The preprocessing of image data with the SPTr-QLED can amplify the image contrast, which is helpful for high-accuracy image recognition.

...