1.
Sci Rep ; 14(1): 7134, 2024 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-38532018

RESUMEN

We aimed to investigate the deliverability of dynamic conformal arc therapy (DCAT) by gantry wobble owing to the intrinsic inter-segment break of the Elekta linear accelerator (LINAC) and its adverse influence on the dose to the patient. The deliverability of DCAT was evaluated according to the plan parameters, which affect the gantry rotation speed and resultant positional inaccuracies; the deliverability according to the number of control points and dose rates was investigated by using treatment machine log files and dosimetry devices, respectively. A non-negligible degradation in DCAT deliverability due to gantry wobble was observed in both the treatment machine log files and dosimetry devices. The resulting dose-delivery error occurred below a certain number of control points or above a certain dose rate. Dose simulations in the patient domain showed a similar impact on deteriorated deliverability. For targets located primarily in the isocenter, the dose differences were negligible, whereas for organs at risk located mainly off-isocenter, the dose differences were significant up to - 8.77%. To ensure safe and accurate radiotherapy, optimal plan parameters should be selected, and gantry angle-specific validations should be conducted before treatment.


Asunto(s)
Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Radioterapia Conformacional/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Aceleradores de Partículas , Radiometría/métodos , Radioterapia de Intensidad Modulada/métodos
2.
Sci Rep ; 13(1): 11027, 2023 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-37419940

RESUMEN

This study aims to evaluate the specific characteristics of various multileaf collimator (MLC) position errors that are correlated with the indices using dose distribution. The dose distribution was investigated using the gamma, structural similarity, and dosiomics indices. Cases from the American Association of Physicists in Medicine Task Group 119 were planned, and systematic and random MLC position errors were simulated. The indices were obtained from distribution maps and statistically significant indices were selected. The final model was determined when all values of the area under the curve, accuracy, precision, sensitivity, and specificity were higher than 0.8 (p < 0.05). The dose-volume histogram (DVH) relative percentage difference between the error-free and error datasets was examined to investigate clinical relations. Seven multivariate predictive models were finalized. The common significant dosiomics indices (GLCM Energy and GLRLM_LRHGE) can characterize the MLC position error. In addition, the finalized logistic regression model for MLC position error prediction showed excellent performance with AUC > 0.9. Furthermore, the results of the DVH were related to dosiomics analysis in that it reflects the characteristics of the MLC position error. It was also shown that dosiomics analysis could provide important information on localized dose-distribution differences in addition to DVH information.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Fantasmas de Imagen , Rayos gamma , Dosificación Radioterapéutica
3.
PLoS One ; 17(8): e0272639, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36026490

RESUMEN

The uncertainties of four-dimensional computed tomography (4DCT), also called as residual motion artefacts (RMA), induced from irregular respiratory patterns can degrade the quality of overall radiotherapy. This study aims to quantify and reduce those uncertainties. A comparative study on quantitative indicators for RMA was performed, and based on this, we proposed a new 4DCT sorting method that is applicable without disrupting the current clinical workflow. In addition to the default phase sorting strategy, both additional amplitude information from external surrogates and the quantitative metric for RMA, investigated in this study, were introduced. The comparison of quantitative indicators and the performance of the proposed sorting method were evaluated via 10 cases of breath-hold (BH) CT and 30 cases of 4DCT. It was confirmed that N-RMSD (normalised root-mean-square-deviation) was best matched to the visual standards of our institute's regime, manual sorting method, and could accurately represent RMA. The performance of the proposed method to reduce 4DCT uncertainties was improved by about 18.8% in the averaged value of N-RMSD compared to the default phase sorting method. To the best of our knowledge, this is the first study that evaluates RMA indicators using both BHCT and 4DCT with visual-criteria-based manual sorting and proposes an improved 4DCT sorting strategy based on them.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Artefactos , Contencion de la Respiración , Humanos , Movimiento (Física) , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador , Respiración
4.
Rev Sci Instrum ; 92(8): 084104, 2021 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-34470429

RESUMEN

Specific tissue lengths or volumes in x-ray images are measured for diagnostic and therapeutic purposes. Measurements are used to make clinical decisions; however, the accuracy of these measurements has not been studied. In this study, based on the sources of uncertainty, an SI-traceable length standard phantom and an x-ray imaging system calibration method are proposed. The uncertainty in the length of the fabricated standard phantom is determined using a toolmaker's microscope. The sources of uncertainty in an x-ray imaging system, such as magnification, pixel-to-millimeter unit conversion, and penumbra effect, are considered, and the lengths of the phantom before and after imaging system calibration were compared. The maximum deviation of length measurements with and without calibration is (-0.11 ± 0.10) and (-3.37 ± 0.15) mm (k = 2, 95% level of confidence), respectively. The proposed phantom and calibration method can be used for calibrating x-ray images and obtaining their length correction values. Furthermore, length correction values are expected to be useful for diagnosis and treatment planning, where precise length measurements are essential.


Asunto(s)
Tomografía Computarizada por Rayos X , Calibración , Fantasmas de Imagen , Rayos X
5.
PLoS One ; 15(12): e0234829, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33270667

RESUMEN

BACKGROUND: This study investigated the effect of accumulated doses on radio-photoluminescence glass dosimeters (RPLGDs) from measurements involving mega-voltage photons. METHODS: Forty-five commercially available RPLGDs were irradiated to estimate their dose responses. Photon beams of 6, 10, and 15 MV were irradiated onto the RPLGDs inside a phantom, which were divided into five groups with different doses and energies. Groups 1 and 2 were irradiated at 1, 5, 10, 50, and 100 Gy in a sequential manner; Group 3 was irradiated 10 times with a dose of 10 Gy; and Groups 4 and 5 followed the same method as that of Group 3, but with doses of 50 Gy and 100 Gy, respectively. Each device was subjected to a measurement reading procedure each time irradiation. RESULTS: For the annealed Group 1, RPLGD exhibited a linearity response with variance within 5%. For the non-annealed Group 2, readings demonstrated hyperlinearity at 6 MV and 10 MV, and linearity at 15 MV. Following the 100 Gy irradiation, the readings for Group 2 were 118.7 ± 1.9%, 112.2 ± 2.7%, and 101.5 ± 2.3% at 6, 10, and 15 MV, respectively. For Groups 3, 4, and 5, the responsiveness of the RPLGDs gradually decreased as the number of repeated irradiations increased. The percentage readings for the 10th beam irradiation with respect to the readings for the primary beam irradiation were 84.6 ± 1.9%, 87.5 ± 2.4%, and 93.0 ± 3.0% at 6 MV, 10 MV, and 15 MV, respectively. CONCLUSIONS: The non-annealed RPLGD response to dose was hyperlinear for the 6 MV and 10 MV photon beams but not for the 15 MV photon beam. Additionally, the annealed RPLGD exhibited a fading phenomenon when the measurement was repeated several times and demonstrated a relatively large fading effect at low energies than at high energies.


Asunto(s)
Dosímetros de Radiación , Vidrio , Fantasmas de Imagen , Fotones , Dosis de Radiación , Dosificación Radioterapéutica , Sensibilidad y Especificidad