Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Nat Med ; 24(9): 1351-1359, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30127395

RESUMEN

Nicotinamide adenine dinucleotide (NAD+) extends longevity in experimental organisms, raising interest in its impact on human health. De novo NAD+ biosynthesis from tryptophan is evolutionarily conserved yet considered supplanted among higher species by biosynthesis from nicotinamide (NAM). Here we show that a bottleneck enzyme in de novo biosynthesis, quinolinate phosphoribosyltransferase (QPRT), defends renal NAD+ and mediates resistance to acute kidney injury (AKI). Following murine AKI, renal NAD+ fell, quinolinate rose, and QPRT declined. QPRT+/- mice exhibited higher quinolinate, lower NAD+, and higher AKI susceptibility. Metabolomics suggested an elevated urinary quinolinate/tryptophan ratio (uQ/T) as an indicator of reduced QPRT. Elevated uQ/T predicted AKI and other adverse outcomes in critically ill patients. A phase 1 placebo-controlled study of oral NAM demonstrated a dose-related increase in circulating NAD+ metabolites. NAM was well tolerated and was associated with less AKI. Therefore, impaired NAD+ biosynthesis may be a feature of high-risk hospitalizations for which NAD+ augmentation could be beneficial.


Asunto(s)
Lesión Renal Aguda/metabolismo , Vías Biosintéticas , NAD/biosíntesis , Lesión Renal Aguda/tratamiento farmacológico , Lesión Renal Aguda/orina , Anciano , Animales , Procedimientos Quirúrgicos Cardíacos , Humanos , Isquemia/orina , Ratones , Persona de Mediana Edad , Niacinamida/administración & dosificación , Niacinamida/uso terapéutico , Pentosiltransferasa/metabolismo , Proyectos Piloto , Ácido Quinolínico/metabolismo , Ácido Quinolínico/orina , Resultado del Tratamiento , Triptófano/orina
2.
Med Instrum (Luton) ; 2(2)2014 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-25045526

RESUMEN

BACKGROUND: The purpose of this study was to investigate the utility and limitations of various imaging modalities in the noninvasive assessment of a novel compact hemodialyzer under development for renal replacement therapy, with specific aim towards monitoring its functional performance. METHODS: The prototype is a 4×3×6 cm aluminum cartridge housing "blood" and "dialysate" flow paths arranged in parallel. A sheet of semipermeable silicon nanopore membranes forms the blood-dialysate interface, allowing passage of small molecules. Blood flow was simulated using a peristaltic pump to instill iodinated contrast through the blood compartment, while de-ionized water was instilled through the dialysate compartment at a matched rate in the countercurrent direction. Images were acquired under these flow conditions using multi-detector computed tomography (MDCT), fluoroscopy, high-resolution quantitative computed tomography (HR-QCT), and magnetic resonance imaging (MRI). MDCT was used to monitor contrast diffusion efficiency by plotting contrast density as a function of position along the path of flow through the cartridge during steady state infusion at 1 and 20 mL/min. Both linear and exponential regressions were used to model contrast decay along the flow path. RESULTS: Both linear and exponential models of contrast decay appeared to be reasonable approximations, yielding similar results for contrast diffusion during a single pass through the cartridge. There was no measurable difference in contrast diffusion when comparing 1 mL/min and 20 mL/min flow rates. Fluoroscopy allowed a gross qualitative assessment of flow within the device, and revealed flow inhomogeneity within the corner of the cartridge opposite the blood inlet port. MRI and HR-QCT were both severely limited due to the paramagnetic properties and high atomic number of the target material, respectively. During testing, we encountered several causes of device malfunction, including leak formation, trapped gas, and contrast-mediated nanopore clogging. We illustrate the imaging manifestations of each. CONCLUSIONS: Despite the inherent challenges in imaging a predominantly metallic device, some modalities show potential in the non-invasive assessment of a novel compact hemodialyzer. The approaches described here could potentially be translated to device evaluation in the implanted setting.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...