RESUMEN
INTRODUCTION: The aim of this study was to present the mid-term results of patients who had undergone a carotid-subclavian bypass surgery after a thoracic endovascular aortic repair (TEVAR) stent-graft implantation with proximal landing at zone 2 of the aorta. METHODS: A total of 66 patients had undergone TEVAR and carotid-subclavian bypass between January 2015 and May 2020 at our clinic. Five of these patients were lost to follow-up, so 61 patients were included in this retrospective study. At follow-up visits, patency of the carotid-subclavian bypass grafts was evaluated with physical examination and radiological imaging. RESULTS: The mean follow-up time was 15.11±12.29 months (ranging from 1 to 56 months). There were 3 (4.91%) in-hospital deaths of patients admitted with bilateral lower limb and visceral malperfusion. There were also 2 (3.27%) deaths unrelated to the procedure. Carotid-subclavian graft occlusion occurred in 3 (4.91%) patients. The occlusion was detected with radiological imaging within a period of 12 to 24 months. The graft patency rate was 100% in the first 12 months. The mean graft patency time (survival) was 52.56±2.10 months. CONCLUSION: Periprocedural carotid-subclavian bypass surgery with synthetic grafts is a recommended procedure with high patency and acceptably low mortality and morbidity rates in TEVAR.
Asunto(s)
Aneurisma de la Aorta Torácica , Arteriopatías Oclusivas , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/métodos , Prótesis Vascular , Arteria Subclavia/cirugía , Procedimientos Endovasculares/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Factores de Tiempo , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Arteriopatías Oclusivas/cirugía , StentsRESUMEN
OBJECTIVE: To investigate the correlation between cardiac output values and renal neutrophil gelatinase-associated lipocalin (NGAL) levels as a biomarker of renal ischemia. METHODS: Forty patients, who underwent off-pump coronary artery bypass (OPCAB) surgery and in whom the positioning of the heart was fixed with simple suspension sutures without a mechanical stabilizer, were included in the study. Continuous cardiac output (CO) measurements were recorded using the arterial pressure waveform analysis method (FloTrac sensor system) in the perioperative period. CO was recorded every minute during non-anatomical cardiac positioning for left anterior descending artery (LAD), diagonal artery (D), circumflex artery (Cx), and right coronary artery (RCA) bypasses. Serum NGAL samples were analyzed in the preoperative, perioperative, and postoperative periods. RESULTS: The CO values measured at various non-anatomical cardiac positions during distal anastomosis for LAD, D, Cx, and RCA were significantly lower than pre- and postoperative values measured with the heart in normal anatomical position (3.45±0.78, 2.9±0.71, 3.11±0.56, 3.19±0.81, 5.03±1.4, and 4.85±0.78, respectively, P=0.008). There was no significant difference between CO values measured at various non-anatomical cardiac positions during distal anastomosis. Although there was no significant correlation between NGAL levels and age, duration of surgery, preoperative CO, D-CO, RCA-CO, and postoperative CO measurements, there was a significant correlation between NGAL levels and LAD-CO (P=0.044) and Cx-CO (P=0.018) at the postoperative 12th hour. CONCLUSION: Full revascularization may be achieved by employing the OPCAB technique while using simple suspension sutures without a mechanical stabilizer and by providing safe CO levels and low risk of renal ischemia.
Asunto(s)
Puente de Arteria Coronaria Off-Pump , Lipocalina 2/metabolismo , Gasto Cardíaco , Vasos Coronarios , Humanos , Riñón , MasculinoRESUMEN
Abstract Objective: To investigate the correlation between cardiac output values and renal neutrophil gelatinase-associated lipocalin (NGAL) levels as a biomarker of renal ischemia. Methods: Forty patients, who underwent off-pump coronary artery bypass (OPCAB) surgery and in whom the positioning of the heart was fixed with simple suspension sutures without a mechanical stabilizer, were included in the study. Continuous cardiac output (CO) measurements were recorded using the arterial pressure waveform analysis method (FloTrac sensor system) in the perioperative period. CO was recorded every minute during non-anatomical cardiac positioning for left anterior descending artery (LAD), diagonal artery (D), circumflex artery (Cx), and right coronary artery (RCA) bypasses. Serum NGAL samples were analyzed in the preoperative, perioperative, and postoperative periods. Results: The CO values measured at various non-anatomical cardiac positions during distal anastomosis for LAD, D, Cx, and RCA were significantly lower than pre- and postoperative values measured with the heart in normal anatomical position (3.45±0.78, 2.9±0.71, 3.11±0.56, 3.19±0.81, 5.03±1.4, and 4.85±0.78, respectively, P=0.008). There was no significant difference between CO values measured at various non-anatomical cardiac positions during distal anastomosis. Although there was no significant correlation between NGAL levels and age, duration of surgery, preoperative CO, D-CO, RCA-CO, and postoperative CO measurements, there was a significant correlation between NGAL levels and LAD-CO (P=0.044) and Cx-CO (P=0.018) at the postoperative 12th hour. Conclusion: Full revascularization may be achieved by employing the OPCAB technique while using simple suspension sutures without a mechanical stabilizer and by providing safe CO levels and low risk of renal ischemia.