Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
2.
Anal Bioanal Chem ; 416(11): 2711-2724, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37541974

RESUMEN

Volumetric absorptive micro-sampling (VAMS) has emerged as a simple and safe tool for collecting and storing blood samples in clinical and bioanalytical fields. This study presents a novel method for determining essential and non-essential trace elements (As, Be, Cd, Cs, Cu, Fe, Mg, P, Pb, S, Sb, Se, Tl, V, U) in VAMS-collected blood samples using microwave-assisted digestion with diluted acid as sample preparation method and an inductively coupled plasma triple quadrupole mass spectrometry (ICP-QQQ) as determination technique. While certain elements posed challenges due to VAMS tip background issues (Al, Ti, Cr, Mn, Co, Ni, Sn, Mo, Ba), the method demonstrated high precision and accuracy for the targeted analytes. It was demonstrated that 4.5 mol L-1 HNO3 plus 100 µL H2O2 30% (w/w) was suitable for an efficiency of digestion for further elemental determination using micro-analysis (spending less than 300 µL analytical solution) by ICP-QQQ, given that the residual carbon content (RCC) after the digestion procedure was lower than 5%. All the results higher than limit of quantification (LOQ) were in agreement with reference values for all analytes. Accuracy was assessed through reference material analysis and recovery tests using spiked samples. Moreover, suitable agreements (p > 0.05) between this method (VAMS-M) and the comparative method (liquid sampling method) were obtained for all analytes >LOQ. Furthermore, all results >LOQ showed good precision according to precision requirements (Horwitz equation). In this way, with the use of dilute acid, low dilution factor (30-fold), and excellent digestion efficiency (>95%), the proposed method was able to achieve an excellent detection limit, precision, and accuracy for 15 elements: As, Be, Cd, Cs, Cu, Fe, Mg, P, Pb, S, Sb, Se, Tl, V, and U using ICP-MS/MS, without the need for matrix-matched calibration curves. This research showcases an innovative analytical approach using VAMS for blood samples, offering biosafety, practicality, sensitivity, versatility, and robustness. This method contributes to the advancement of trace element analysis in biomedical research and clinical applications.


Asunto(s)
Espectrometría de Masas en Tándem , Oligoelementos , Peróxido de Hidrógeno , Cadmio , Plomo , Oligoelementos/análisis
3.
Front Public Health ; 11: 1192315, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37529436

RESUMEN

Introduction: Improving patient safety is one of the most critical components of modern healthcare. Emergency medical services (EMS) are, by nature, a challenging environment for ensuring patient safety. It is fast-paced, physically dangerous, and highly stressful, requiring rapid decision-making and action. This can create risks not only for patients but also for employees. We assessed variations in perceptions of safety culture in prehospital emergency care among an international sample of paramedics and nurses. Methods: The Emergency Medical Services Safety Attitudes Questionnaire (EMS-SAQ) was used for the study. The instrument measures six domains of safety culture in the workplace: teamwork climate, job satisfaction, safety climate, working conditions, stress recognition, and perceptions of management. A total of 1,128 EMS from 9 countries participated in this study. Results: Safety Climate was 81.32/100 (SD 6.90), Teamwork Climate 84.14/100 (SD 8.74), Perceptions of Management 76.30/100 (SD 10.54), Stress Recognition 89.86/100 (SD 5.70), Working Conditions 81.07/100 (SD 9.75), and Job Satisfaction 70.71/100 (SD 7.21). There was significant variation in safety culture scores across countries for teamwork climate (TWC), working conditions (WC), and job satisfaction (JS). Among the individual variables (age, gender, level of education, and work experience), variations in safety culture scores were unaffected by age, gender, or work experience. Organizational characteristics: employment status and position type were linked to significant variations in safety culture domain scores. Conclusion: Participants' perceptions of the patient safety climate were not particularly satisfactory, confirming that there is still a need to develop a culture of patient safety in prehospital emergency care.


Asunto(s)
Servicios Médicos de Urgencia , Cultura Organizacional , Humanos , Estudios Transversales , Administración de la Seguridad , Hospitales
4.
Artículo en Inglés | MEDLINE | ID: mdl-36011431

RESUMEN

INTRODUCTION: Nursing staff working in a shift or night system are exposed to sleep disorders, which has a direct impact on the emergence of dangerous health consequences for them. Melatonin secretion is abnormal at night and the circadian rhythm is disturbed. The aim of the study was to assess the occurrence of sleep disorders and their consequences for the body in a group of representative nursing staff working in a shift and night system. PARTICIPANTS: The study was conducted among 126 nurses who are generally healthy, employed in health care facilities in the Malopolskie voivodship. METHODS: The Athens Insomnia Scale consisting of 8 test items was used to obtain research material: falling asleep, waking up at night, waking up in the morning, total sleep time, sleep quality, well-being the next day, mental and physical fitness the next day, and sleepiness during the next day. As well as an original questionnaire. RESULTS: The research showed significant negative consequences of shift work on the health of health-care workers. The subjects noticed symptoms related to the nervous system, such as increased nervous tension 53%, lack of patience in 62% of all respondents. As many as 85% pointed to the negative impact of shift work on their family life, 82% of all respondents on social life and 56% of all respondents on sex life. The other variables were not confirmed. CONCLUSIONS: Symptoms of insomnia are common among night-work nurses.


Asunto(s)
Enfermeras y Enfermeros , Trastornos del Sueño del Ritmo Circadiano , Trastornos del Inicio y del Mantenimiento del Sueño , Ritmo Circadiano , Humanos , Sueño/fisiología , Trastornos del Sueño del Ritmo Circadiano/epidemiología , Trastornos del Inicio y del Mantenimiento del Sueño/epidemiología , Tolerancia al Trabajo Programado/fisiología
5.
Artículo en Inglés | MEDLINE | ID: mdl-35955067

RESUMEN

The patient safety climate is a key element of quality in healthcare. It should be a priority in the healthcare systems of all countries in the world. The goal of patient safety programs is to prevent errors and reduce the potential harm to patients when using healthcare services. A safety climate is also necessary to ensure a safe working environment for healthcare professionals. The attitudes of healthcare workers toward patient safety in various aspects of work, organization and functioning of the ward are important elements of the organization's safety culture. The aim of this study was to determine the perception of the patient safety climate by healthcare workers during the COVID-19 pandemic. Methods: The study was conducted in five European countries. The Safety Attitude Questionnaire (SAQ) short version was used for the study. A total of 1061 healthcare workers: physicians, nurses and paramedics, participated in this study. Results: All groups received the highest mean results on the stress recognition subscale (SR): nurses 98.77, paramedics 96.39 and physician 98.28. Nurses and physicians evaluated work conditions (WC) to be the lowest (47.19 and 44.99), while paramedics evaluated perceptions of management (PM) as the worst (46.44). Paramedics achieved statistically significantly lower scores compared to nurses and physicians in job satisfaction (JS), stress recognition (SR) and perception of management (PM) (p < 0.0001). Paramedics compared to nurses and physicians rank better in working conditions (WC) in relation to patient safety (16.21%). Most often, persons of lower seniority scored higher in all subscales (p = 0.001). In Poland, Spain, France, Turkey, and Greece, healthcare workers scored highest in stress recognition (SR). In Poland, Spain, France, and Turkey, they assessed working conditions (WC) as the worst, while in Greece, the perception of management (PM) had the lowest result. Conclusion: Participant perceptions about the patient safety climate were not at a particularly satisfactory level, and there is still a need for the development of patient safety culture in healthcare in Europe. Overall, positive working conditions, good management and effective teamwork can contribute to improving employees' attitudes toward patient safety. This study was carried out during the COVID-19 pandemic and should be repeated after its completion, and comparative studies will allow for a more precise determination of the safety climate in the assessment of employees.


Asunto(s)
COVID-19 , Seguridad del Paciente , Actitud del Personal de Salud , COVID-19/epidemiología , Estudios Transversales , Personal de Salud , Humanos , Satisfacción en el Trabajo , Cultura Organizacional , Pandemias , Percepción , Administración de la Seguridad , Encuestas y Cuestionarios
6.
Mult Scler Relat Disord ; 57: 103344, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35158453

RESUMEN

BACKGROUND: Epidemiologic data on pediatric-onset multiple sclerosis (POMS) in Central and Eastern Europe are limited. The aim of this study was to determine the incidence, prevalence and the clinical features of POMS in Poland. METHODS: Registry-based retrospective study was conducted among Polish children population (age ≤ 18 years), between 1 January 2010 and 31 December 2019. A total of 329 pediatric or juvenile patients fulfilled the International Pediatric MS Study Group (IPMSSG) criteria for MS, reported to the Polish Multiple Sclerosis Registry, were considered for estimation of age- and sex-specific prevalence (per 100,000 persons), and incidence rates (per 100,000 person-years). The demographic data, clinical presentation and treatment strategies also were investigated. RESULTS: On December 31, 2019 in the database were collected data of 329 patients up to 18 years with POMS diagnosis (101 boys and 228 girls; mean age 15.3 ± 3.8 years). The age-adjusted prevalence standardized to the European Standard Population was 5.19/100,000 (95% confidence interval (CI), 4.64-5.78). A significantly higher prevalence was recorded in girls (7.41; 95% CI, 6.48-8.44) than in boys (3.08; 95% CI, 2.50-3.74; P<0.001). The mean annual standardized incidence in Poland between 2015 - 2019 was 0.77 (95%CI, 0.45-1.02) per 100,000 person-years. The highest overall standardized incidence 1.06 (95%CI, 0.82-1.34) was noted in 2018. Most of patients (95.7%) had relapsing-remitting disease with polysymptomatic onset in one-thirds of the cases, and 82.3% were treated with disease-modifying drugs. Family history of MS was reported in 26 cases (7.9%). CONCLUSION: In this first report of registry-based study from Poland an increasing prevalence and incidence of POMS was found during the last years. This temporal trend corroborate the findings of studies conducted elsewhere.


Asunto(s)
Esclerosis Múltiple , Adolescente , Adulto , Niño , Femenino , Humanos , Incidencia , Masculino , Esclerosis Múltiple/epidemiología , Polonia/epidemiología , Sistema de Registros , Estudios Retrospectivos , Adulto Joven
9.
Eur J Heart Fail ; 15(7): 796-807, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23426023

RESUMEN

AIMS: To assess, and identify predictors of 2-year adverse outcomes of surgical high-risk patients after successful MitraClip therapy (MC), differentiated by the aetiology of mitral regurgitation (MR). METHODS AND RESULTS: Kaplan-Meier analysis was used to assess survival free from death, heart failure rehospitalization, and reintervention up to 2 years in 202 successfully treated patients [74 ± 9 years, 132 men (65%); secondary MR aetiology in 140 patients, primary MR in 62]. Predictors for study endpoints were determined using Cox regression analyses. Mortality was 20% at 1 year and 33% at 2 years in both primary and secondary MR patients; independent predictors of death were reduced forward stroke volume, impaired LV function, and renal failure in primary MR, yet only an increased logistic EuroSCORE in functional MR patients. The rate of rehospitalizations was not different between the patient subgroups for 6 months, but then diverged significantly in favour of primary MR patients (estimated 2-year incidence, primary MR 40% vs. secondary MR 66%). No predictor was found for primary MR patients, but increased LV end-diastolic volume significantly increased the risk of rehospitalization in functional MR patients. Reinterventions were overall rare (7.4% at 1 year, 9.7% at 2 years); primary MR patients required all except one reintervention within 2 months of MC, with again no predictors found, whereas secondary MR patients (all except one with discharge MR of 2+) exhibited a steadily declining freedom from reintervention curve throughout follow-up. CONCLUSION: MR aetiology affects rehospitalization and reintervention, but not mortality, differently after successful MC.


Asunto(s)
Insuficiencia Cardíaca/complicaciones , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/etiología , Anciano , Ecocardiografía , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Humanos , Estimación de Kaplan-Meier , Imagen por Resonancia Cinemagnética , Masculino , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/cirugía , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento
11.
JACC Cardiovasc Interv ; 5(3): 341-9, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22440502

RESUMEN

OBJECTIVES: This study reports the results of a series of transapical mitral valve-in-valve implantations and aims to offer guidance on technical aspects of the procedure. BACKGROUND: Mitral valve reoperations due to failing bioprostheses are associated with high morbidity and mortality. Transcatheter techniques may evolve as complementary approaches to surgery in these high-risk patients. METHODS: Six patients (age 75 ± 15 years) received transapical implantation of a balloon-expandable pericardial heart valve into a degenerated bioprosthesis (range 27 to 31 mm) in mitral position at our institution. All patients were considered high risk for surgical valve replacement (logistic EuroSCORE: 33 ± 15%) after evaluation by an interdisciplinary heart team. Procedural and clinical outcomes were analyzed. RESULTS: Implantation was successful in all patients with reduction of mean transvalvular gradients from 11.3 ± 5.2 mm Hg to 5.5 ± 3.6 mm Hg (p = 0.016) and median regurgitation from grade 3.0 (interquartile range [IQR]: 2.7 to 3.1) to 0 (IQR: 0 to 1.0, p = 0.033) with trace paravalvular regurgitation remaining in 2 patients. Apical bleeding occurred in 2 patients requiring rethoracotomy in 1 and resuscitation in a second patient, the latter of whom died on postoperative day 6. In the remaining patients, median New York Heart Association functional class improved from 3.0 (IQR: 3.0 to 3.5) to 2.0 (IQR: 1.5 to 2.0, p = 0.048) over a median follow-up of 70 (IQR: 25.5 to 358) days. CONCLUSIONS: With acceptable results in a high-risk population, transapical mitral valve-in-valve implantation can be considered as a complementary approach to reoperative mitral valve surgery in select patients.


Asunto(s)
Bioprótesis , Cateterismo Cardíaco/instrumentación , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo , Femenino , Alemania , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Modelos Logísticos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Diseño de Prótesis , Radiografía , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía
12.
J Thorac Cardiovasc Surg ; 143(3): 617-24, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22169448

RESUMEN

OBJECTIVE: Transcatheter valve-in-valve implantation is evolving as an alternative to reoperative valve replacement in high-risk patients with degenerated bioprostheses. Nevertheless, hemodynamic performance is limited by the previously implanted xenograft. We report our experience with patient-prosthesis mismatch (PPM) after valve-in-valve implantation in the aortic position. METHODS: Eleven patients (aged 79.3 ± 6.1 years) received transapical implantation of a balloon-expandable pericardial heart valve into a degenerated bioprosthesis (size, 23.9 ± 1.6 mm; range, 21-27 mm) in the aortic position. All patients were considered high risk for surgical valve replacement (logistic European System for Cardiac Operative Risk Evaluation, 31.8% ± 24.1%). Severe PPM was defined as an indexed effective orifice area less than 0.65 cm(2)/m(2), determined by discharge echocardiography. RESULTS: Severe PPM was evident in 5 patients (group 1) and absent in 6 patients (group 2). Mean transvalvular gradients decreased from 29.2 ± 15.4 mm Hg before implantation to 21.2 ± 9.7 mm Hg at discharge (group 1) and from 28.2 ± 9.0 mm Hg before implantation to 15.2 ± 6.5 mm Hg at discharge (group 2). Indexed effective orifice area increased from 0.5 ± 0.1 cm(2)/m(2) to 0.6 ± 0.1 cm(2)/m(2) and from 0.6 ± 0.3 cm(2)/m(2) to 0.8 ± 0.3 cm(2)/m(2). Aortic regurgitation decreased from grade 2.0 ± 1.1 to 0.4 ± 0.5 overall. No differences in New York Heart Association class improvement or survival during follow-up were observed. One patient required reoperation for symptomatic PPM 426 days after implantation. CONCLUSIONS: Valve-in-valve implantation can be performed in high-risk surgical patients to avoid reoperation. However, PPM frequently occurs, making adequate patient selection crucial. Small bioprostheses (<23 mm) should be avoided. Implantation into 23-mm xenografts can be recommended only for patients with a body surface area less than 1.8 m(2). Larger prostheses seem to carry a lower risk for PPM. Although no delay in clinical improvement was seen at short-term, 1 PPM-related surgical intervention raises concern regarding long-term performance.


Asunto(s)
Insuficiencia de la Válvula Aórtica/terapia , Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/cirugía , Bioprótesis , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/mortalidad , Cateterismo Cardíaco/efectos adversos , Femenino , Alemania , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento , Ultrasonografía
13.
J Thorac Cardiovasc Surg ; 143(1): 78-84, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22036261

RESUMEN

OBJECTIVE: Surgical mitral valve repair carries an elevated perioperative risk in the presence of severely reduced ventricular function and relevant comorbidities. We sought to assess the feasibility of catheter-based mitral valve repair using a clip-based percutaneous edge-to-edge repair system in selected patients at high surgical risk with mitral regurgitation grade 3 or worse. METHODS: Between 2002 and January 2011, 202 consecutive patients without prior mitral valve surgery (age 75 ± 9 years; 63% were male) with symptomatic functional (65%), degenerative (27%), or mixed (8%) mitral regurgitation were treated with a percutaneous clip system for approximation of the anterior and posterior mitral leaflets. Risk for mitral valve surgery was considered high in terms of a mean logistic European System for Cardiac Operative Risk Evaluation of 44% (range, 21%-54%). Preprocedural left ventricular ejection fraction was 35% or less in 36% of patients. An interdisciplinary heart team of cardiologists and cardiac surgeons discussed all patients. RESULTS: Percutaneous clip implantation was successful in 186 patients (92%). Patients were treated with 1 clip (n = 125; 62%), 2 clips (n = 64; 32%), or 3 or more clips (n = 7; 3%). Reduction in mitral regurgitation from pre- to postprocedure was significant (P < .0001) and remained stable within the first 12 months in the majority of patients. Thirty-day mortality was 3.5% (7/202 patients). Hospital stay was 12 ± 10 days, and median intensive care unit stay was 1 day (range, 0-45 days). Eleven patients required surgical valve repair/replacement at a median of 38 days (0-468 days) after percutaneous clip implantation. CONCLUSIONS: Clip-based percutaneous mitral valve repair is a safe, low-risk, and effective therapeutic option in symptomatic patients with a high risk for surgery and does not exclude later surgical repair.


Asunto(s)
Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Actitud del Personal de Salud , Procedimientos Quirúrgicos Cardíacos/métodos , Árboles de Decisión , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Grupo de Atención al Paciente , Estudios Prospectivos , Implantación de Prótesis/métodos , Factores de Riesgo
14.
J Am Coll Cardiol ; 58(21): 2190-5, 2011 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-22078425

RESUMEN

OBJECTIVES: The aim of this study was to assess the outcomes of patients at prohibitive surgical risk undergoing MitraClip therapy (Abbott Vascular, Redwood City, California) for severe mitral regurgitation (MR). BACKGROUND: The safety of percutaneous mitral valve repair has been documented. However, midterm development of mitral valve function, ventricular remodeling, and clinical outcomes in patients not amenable to surgery are unknown. METHODS: A total of 104 consecutive patients (mean age 74 ± 9 years; 64 men; 49 and 54 with MR 3+ and 4+, respectively; 69 with functional MR; 59 and 45 in New York Heart Association classes III and IV, respectively) were followed for a median of 359 days. RESULTS: Device success was achieved in 96 patients (92%). In patients with successful index procedures, MR grade ≤2+ was present at follow-up in 82.5%, left ventricular end-diastolic and -systolic volumes were reduced, and forward stroke volumes were significantly increased. Improvements in New York Heart Association functional class were observed in 80% of patients, with 69% in class I or II; 75% improved in the 6-min walk test; and 74% reported improvements in quality of life. One-year estimates of mortality and rehospitalization were 22% and 31%, respectively. Forward stroke volume at discharge emerged as a predictor of event-free survival. CONCLUSIONS: MitraClip therapy improves clinical and echocardiographic outcomes at 1 year in about three-quarters of critically ill, elderly patients with moderate to severe MR not amenable to surgery.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Ecocardiografía , Insuficiencia de la Válvula Mitral/terapia , Remodelación Ventricular/fisiología , Anciano , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Estudios Retrospectivos , Volumen Sistólico/fisiología , Resultado del Tratamiento
15.
Eur Heart J ; 31(11): 1373-81, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20219746

RESUMEN

AIMS: We sought to assess the feasibility of catheter-based mitral valve repair using the MitraClip system in high-surgical-risk patients with mitral regurgitation (MR) > or =grade 3+. METHODS AND RESULTS: MitraClip therapy was performed in 51 consecutive patients [73 +/- 10 years; 34 (67%) men] with symptomatic functional [n = 35 (69%)] or organic MR [n = 16 (31%)]. Mean logistic EuroSCORE was 29 +/- 22%; Society of Thoracic Surgeons score was 15 +/- 11. Left ventricular (LV) ejection fraction was 36 +/- 17%. In 35 patients (69%), adverse mitral valve morphology and/or severe LV dysfunction were present. MitraClip implantation was successful in 49 patients (96%). Most patients [n = 34/49 (69%)] were treated with a single clip, whereas 14 patients (29%) received two clips and one patient received three clips. Mean device and fluoroscopy times were 105 +/- 65 min and 44 +/- 28 min, respectively. Procedure-related reduction in MR severity was one grade in 16 patients (31%), two grades in 24 patients (47%), and three grades in 9 patients (18%). Forty-four of the 49 successfully treated patients (90%) showed clinical improvement at discharge [NYHA functional class > or =III in 48 patients (98%) before and 16 patients (33%) after the procedure (P < 0.0001)]. There were no procedure-related major adverse events and no in-hospital mortality. CONCLUSION: Mitral valve repair using the MitraClip system was shown to be feasible in patients at high surgical risk primarily determined by an adverse mitral valve morphology and/or severe LV dysfunction.


Asunto(s)
Anuloplastia de la Válvula Mitral/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Complicaciones Posoperatorias/etiología , Instrumentos Quirúrgicos , Disfunción Ventricular Izquierda/cirugía , Anciano , Anciano de 80 o más Años , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Estudios de Factibilidad , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/patología , Insuficiencia de la Válvula Mitral/patología , Insuficiencia de la Válvula Mitral/fisiopatología , Factores de Riesgo , Disfunción Ventricular Izquierda/patología , Disfunción Ventricular Izquierda/fisiopatología
16.
J Clin Oncol ; 25(25): 3859-65, 2007 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-17646669

RESUMEN

PURPOSE: The purpose of this analysis was to investigate trastuzumab-associated cardiac adverse effects in breast cancer patients after completion of (neo)adjuvant chemotherapy with or without radiotherapy. PATIENTS AND METHODS: The Herceptin Adjuvant (HERA) trial is a three-group, multicenter, open-label randomized trial that compared 1 or 2 years of trastuzumab given once every 3 weeks with observation in patients with HER-2-positive breast cancer. Only patients who after completion of (neo)adjuvant chemotherapy with or without radiotherapy had normal left ventricular ejection fraction (LVEF > or = 55%) were eligible. A repeat LVEF assessment was performed in case of cardiac dysfunction. RESULTS: Data were available for 1,693 patients randomly assigned to 1 year trastuzumab and 1,693 patients randomly assigned to observation. The incidence of trastuzumab discontinuation due to cardiac disorders was low (4.3%). The incidence of cardiac end points was higher in the trastuzumab group compared with observation (severe congestive heart failure [CHF], 0.60% v 0.00%; symptomatic CHF, 2.15% v 0.12%; confirmed significant LVEF drops, 3.04% v 0.53%). Most patients with cardiac dysfunction recovered in fewer than 6 months. Patients with trastuzumab-associated cardiac dysfunction were treated with higher cumulative doses of doxorubicin (287 mg/m(2) v 257 mg/m(2)) or epirubicin (480 mg/m(2) v 422 mg/m(2)) and had a lower screening LVEF and a higher body mass index. CONCLUSION: Given the clear benefit in disease-free survival, the low incidence of cardiac adverse events, and the suggestion that cardiac dysfunction might be reversible, adjuvant trastuzumab should be considered for treatment of breast cancer patients who fulfill the HERA trial eligibility criteria.


Asunto(s)
Anticuerpos Monoclonales/efectos adversos , Antineoplásicos/efectos adversos , Neoplasias de la Mama/tratamiento farmacológico , Enfermedades Cardiovasculares/inducido químicamente , Anticuerpos Monoclonales/administración & dosificación , Anticuerpos Monoclonales Humanizados , Supervivencia sin Enfermedad , Femenino , Insuficiencia Cardíaca/inducido químicamente , Humanos , Persona de Mediana Edad , Receptor ErbB-2/metabolismo , Trastuzumab
17.
Circulation ; 112(9 Suppl): I260-4, 2005 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-16159828

RESUMEN

BACKGROUND: Despite growing interest in stent-graft implantation for type-B aortic dissection, there are no established recommendations to prepare and perform an implantation procedure. METHODS AND RESULTS: We directly compared angiography (ANGIO), transesophageal echocardiography (TEE), and intravascular ultrasound (IVUS) intraprocedually before and after placement of 48 stent grafts in 42 consecutive patients (12 women, 61+/-11 years of age) with acute and chronic type-B aortic dissection for both usefulness and capability to guide aortic stent-graft implantation. Both IVUS and TEE are superior to ANGIO to identify multiple entries (52 and 43 versus 34; P<0.005 each), to diagnose false-lumen slow flow after stent-graft implantation (32 and 31 versus 24; P<0.005 each) and to detect incomplete stent apposition (18 and 16 versus 8; P<0.005 each). In comparison with ANGIO, guide wire position over the entire length of the aorta was documented more frequently by TEE and IVUS (40 and 42 versus 25; P<0.001 each). In 4 patients with abdominal extension of the dissection, only IVUS was able to accurately identify the false lumen over the entire length of the diseased aorta. TEE was superior to IVUS and ANGIO in the detection of endoleaks (5 versus 0 and 1; P<0.05 each). Intraprocedural ANGIO, TEE, and IVUS had been performed without complications in all patients. CONCLUSIONS: TEE in conjunction with ANGIO appears to be advantageous and adds incremental information to safely guide stent-graft placement in type-B aortic dissection. Additional use of IVUS was found to be helpful in patients with complex anatomy and abdominal extension of the dissection.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Aortografía , Implantación de Prótesis Vascular/métodos , Ecocardiografía Transesofágica , Radiografía Intervencional , Stents , Ultrasonografía Intervencional , Anciano , Disección Aórtica/clasificación , Disección Aórtica/diagnóstico por imagen , Aneurisma de la Aorta/clasificación , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/clasificación , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/clasificación , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Cateterismo Cardíaco , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tereftalatos Polietilenos , Estudios Retrospectivos
18.
J Card Surg ; 18(5): 471-7, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12974938

RESUMEN

BACKGROUND: Endovascular stent-graft placement is a new concept for the treatment of aortic dissection and aneurysm. Intravascular ultrasound (IVUS) with established diagnostic features may be instrumental in guiding endovascular procedures. METHODS: We performed IVUS and digital angiography before, during, and after implantation of 47 stent grafts in 40 patients with Stanford type B dissection (26 patients, 28 stent grafts), thoracic aneurysm (9 patients, 11 stent grafts), and abdominal aneurysm (5 patients, 8 stent grafts). RESULTS: IVUS could clearly identify the aortic anatomy and differentiate between true and false lumen in all cases of dissection. In four patients with type B dissection extending from the thoracic to the abdominal aorta the true lumen was exclusively identified by IVUS, and thus, essential for safe execution of the procedure. In another patient stent-graft placement in the aorta was optimized by covering a second entry detected by IVUS, but undetected by angiography. The site of stent implantation, the true and false lumen, as well as entry and reentry were always identified in both thoracic and abdominal aorta. In comparison with angiography, IVUS information led to additional balloon molding due to incomplete stent apposition in seven cases. CONCLUSIONS: As an adjunctive imaging modality IVUS is likely to improve stent-graft placement in aortic type B dissection, especially in patients with abdominal extension.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Implantación de Prótesis Vascular , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Stents , Ultrasonografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA