Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
1.
Medicines (Basel) ; 7(4)2020 Mar 31.
Article En | MEDLINE | ID: mdl-32244404

Background: Gagging during transesophageal echocardiography examination (TEE) can be distressing and even dangerous for patients. The needling of acupuncture point CV24 was described to be effective in reducing the gag reflex during TEE in patients with ischemic stroke or transient ischemic attack. Methods: We describe a proposal for a prospective, randomized, patient, practitioner and assessor-blinded, single-center trial with two arms/groups; real acupuncture will be compared to placebo acupuncture. A total of 60 (30 per group) patients scheduled for elective TEE in order to exclude a cardiac embolic source, endocarditis or for valve failure evaluation will be recruited according to patients' selection criteria and receive either indwelling fixed intradermal needles at acupoints CV24 and bilateral PC6 or placebo needles at the same areas. Patients, the practitioners who will perform the TEE procedure, and the assessor of the outcome measures will be unaware of the group's (real or placebo) allocation. Results: The primary outcome is the intensity of gagging, measured using verbal rating scale (VRS-11) from 0 = no gagging to 10 = intolerable gagging. Secondary outcomes include the incidence of gagging, the use of rescue medication, patients' satisfaction with relief of unwanted side effects during TEE procedure, success of patients' blinding (patients' opinion to group allocation), heart rate and oxygen saturation measured by pulse oxymetry. Conclusions: To study the effects of acupuncture against gagging during TEE, we test the needling of acupoints CV24 and PC6 bilaterally. A placebo acupuncture is used for the control group. Trial registration number: NCT NCT0382142.

2.
Curr Opin Anaesthesiol ; 30(6): 652-657, 2017 Dec.
Article En | MEDLINE | ID: mdl-28938299

PURPOSE OF REVIEW: The purpose of this review is to take a look on some practical aspects of anesthetic care in the endoscopy suite, concerning the general approach, safety, and monitoring issues. RECENT FINDINGS: Concerning propofol popularity for sedation during endoscopic procedures new studies create doubt in the safety of higher doses of propofol used for sedation. Careful titration of propofol, addition of synergistic supplements like ketamine and dexmedetomidine, and monitoring of anesthetic depth may limit the dose of propofol given to the patients. Capnography has the potential to detect airway compromise earlier than pulse-oximetry and by this enhancing patient safety. SUMMARY: Sedation or anesthesia in the endoscopy suite is not without risk. For complex and longer lasting procedures and in patients with significant comorbidities and risk factors, good clinical judgment, built on experience, is essential and to foster this, it seems prudent to build up a group of anesthesiologists dedicated to a special sedation service.


Anesthesia/methods , Endoscopy/methods , Anesthesia/adverse effects , Anesthetics , Conscious Sedation , Endoscopy/adverse effects , Humans , Hypnotics and Sedatives , Patient Safety , Propofol
3.
Crit Care ; 19: 321, 2015 Sep 08.
Article En | MEDLINE | ID: mdl-26353802

INTRODUCTION: Ionized calcium (iCa) concentration is often used in critical care and measured using blood gas analyzers at the point of care. Controlling and adjusting regional citrate anticoagulation (RCA) for continuous renal replacement therapy (CRRT) involves measuring the iCa concentration in two samples: systemic with physiological iCa concentrations and post filter samples with very low iCa concentrations. However, modern blood gas analyzers are optimized for physiological iCa concentrations which might make them less suitable for measuring low iCa in blood with a high concentration of citrate. We present results of iCa measurements from six different blood gas analyzers and the impact on clinical decisions based on the recommendations of the dialysis' device manufacturer. METHOD: The iCa concentrations of systemic and post filter samples were measured using six distinct, frequently used blood gas analyzers. We obtained iCa results of 74 systemic and 84 post filter samples from patients undergoing RCA for CRRT at the University Medicine of Greifswald. RESULTS: The systemic samples showed concordant results on all analyzers with median iCa concentrations ranging from 1.07 to 1.16 mmol/L. The medians of iCa concentrations for post filter samples ranged from 0.21 to 0.50 mmol/L. Results of >70% of the post filter samples would lead to major differences in decisions regarding citrate flow depending on the instrument used. CONCLUSION: Measurements of iCa in post filter samples may give misleading information in monitoring the RCA. Recommendations of the dialysis manufacturer need to be revised. Meanwhile, little weight should be given to post filter iCa. Reference methods for low iCa in whole blood containing citrate should be established.


Anticoagulants/therapeutic use , Blood Gas Analysis , Calcium/blood , Citrates/therapeutic use , Hemofiltration/methods , Blood Gas Analysis/instrumentation , Blood Gas Analysis/methods , False Negative Reactions , False Positive Reactions , Humans , Reproducibility of Results
...