Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Toxicol Pathol ; 47(4): 494-503, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30987541

RESUMEN

Drug-induced unique cytoplasmic vacuolation was found in the subchronic oral toxicity study of 4-dimethylamino-1-{3-(1-methyl-1H-imidazole-2-yl)propanoyl}piperidine (DMIP), a potential therapeutic agent for neuropathic pain, in beagle dogs. In the first study, DMIP was administered at a dose of 250, 500, or 1,000 mg/kg/day once daily for 14 days. Discoloration of tapetum lucidum accompanied by tapetal swelling was observed at ≥250 mg/kg/day. The tapetal swelling was correlated to the light microscopic observation of cytoplasmic vacuolation in tapetal cells, and similar vacuolation was observed in several other tissues, including the coronary artery and aortal arch, in a dose-dependent manner. Immunohistochemistry for lysosomal-associated membrane protein 2 indicated that the vacuoles were enlarged lysosomes. However, the nature of these vacuoles was different from that of phospholipidosis because no lamellar bodies were observed. In the second study, DMIP was administered at a dose of 10, 50, or 250 mg/kg/day once daily for 14 days followed by a 14-day recovery period. Tapetal changes and systemic vacuolation were not observed at ≤50 mg/kg/day, and vacuolation observed at 250 mg/kg/day was reversible. A few reports have described the enlargement of lysosomes not attributable to phospholipid accumulation. Our findings provide further information about the toxicological implications of drug-induced lysosomal swelling.


Asunto(s)
Analgésicos/toxicidad , Coroides/efectos de los fármacos , Imidazoles/toxicidad , Piperidinas/toxicidad , Vacuolas/efectos de los fármacos , Administración Oral , Animales , Coroides/citología , Coroides/metabolismo , Perros , Relación Dosis-Respuesta a Droga , Femenino , Proteína 2 de la Membrana Asociada a los Lisosomas/metabolismo , Lisosomas/efectos de los fármacos , Lisosomas/metabolismo , Masculino , Microscopía , Vacuolas/metabolismo
3.
Acta Radiol ; 55(8): 938-44, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24123996

RESUMEN

BACKGROUND: Iodinated contrast media (CM) have molecular and pharmacokinetic properties likely to make them highly dialyzable. Controlled clinical studies allowing for comparisons of hemodialysis clearance between different test substances and in multiple hemodialysis filters are, however, complex and not always practically feasible. A miniaturized in vitro method was therefore developed to evaluate the dialyzability of a new CM. PURPOSE: To evaluate hemodialysis clearance of iosimenol, a novel iso-osmolar contrast medium (CM), in a select variety of hemodialysis filters and in comparison to commercially available CM. MATERIAL AND METHODS: Three different high-flux and one low-flux membrane were used in miniaturized dialyzers to evaluate the in vitro blood clearance of iosimenol. Commercially available CM (iodixanol and iohexol) served as control substances. In vitro dialysis parameters were then used to predict clinical hemodialysis clearances. Residual ratios of endogenous substances (inorganic phosphate, urea nitrogen, creatinine, total bilirubin, and albumin) were used as proof of reliability of the in vitro dialysis system. RESULTS: Dialyzable small endogenous molecules were readily eliminated in all membranes. The removal ratios of iosimenol were generally similar to that of iodixanol in all membranes except the high-flux polysulfone but were consistently lower than that of iohexol. The blood clearance of iosimenol during clinical hemodialysis was predicted as, on average, approximately 85 mL/min with the high-flux membranes and 47 mL/min with the low-flux membrane. CONCLUSION: The dialyzability of iosimenol was evaluated using a newly developed in vitro dialysis system, and iosimenol was readily cleared from blood with all four tested membranes. And it is suggested that the dialysis parameters can predict clinical hemodialysis clearance of CM.


Asunto(s)
Benzamidas/farmacocinética , Medios de Contraste/farmacocinética , Propanolaminas/farmacocinética , Diálisis Renal/métodos , Filtración/instrumentación , Humanos , Diálisis Renal/instrumentación , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA