1.
JACC Clin Electrophysiol ; 6(3): 304-310, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32192681

RESUMEN

OBJECTIVES: This study investigated the performance of Temporary Pacing via an Externalized Active-Fixation (TPEAF) lead. BACKGROUND: The incidence of cardiac implantable electronic device infections is increasing, which necessitates the need for transvenous lead extraction (TLE). Pacemaker-dependent patients require temporary pacing during the guideline-recommended waiting period before reimplantation. Data regarding safety and efficacy of TPEAF leads are very limited. METHODS: We evaluated patients implanted with TPEAF leads post-TLE at our center between April 2004 and December 2017. RESULTS: TPEAF leads were placed in 158 patients. The mean age was 74 ± 11 years. The median duration of the temporary lead was 6 days (range 1 to 29). There were 4 procedural complications (2.5% incidence): 1 patient had cardiac arrest from hyperkalemia, 2 developed cardiac tamponade, and 1 had profuse bleeding from the entry point of the leads. There were 13 complications post-implantation (8.2% incidence): 8 lead dislodgments, 1 elevated pacing threshold, 2 vegetations on the temporary lead, 1 pneumothorax, and 1 loss of capture due to the generator "safety switch." All dislodgements occurred within 24 h, except 1 on day 3. Sixteen patients died during the hospital stay: 10 due to septic shock, 2 due to hyperkalemic cardiac arrest, 3 due to ventricular tachycardia, and 1 due to a massive cerebrovascular accident. CONCLUSIONS: The use of TPEAF leads is safe and efficacious in pacemaker-dependent patients post-TLE. Dislodgement can occur within the first 24 h. The presence of persistent fever and positive blood cultures should raise concern for vegetation on the temporary lead.


Asunto(s)
Estimulación Cardíaca Artificial , Desfibriladores Implantables , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estimulación Cardíaca Artificial/estadística & datos numéricos , Desfibriladores Implantables/efectos adversos , Desfibriladores Implantables/estadística & datos numéricos , Remoción de Dispositivos/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos , Marcapaso Artificial/estadística & datos numéricos , Resultado del Tratamiento
3.
Clin Pract ; 8(2): 1054, 2018 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-30069298

RESUMEN

Amyloidosis is a complex group of disorders that can involve many organs and cause their dysfunction. Cardiac involvement indicates worse prognosis and influences treatment strategies. Cardiac amyloidosis is an under-diagnosed entity and high index of clinical suspicion and careful interpretation of basic diagnostic tools such as electrocardiogram and echocardiography is needed for early detection. Congestive heart failure due to restrictive pattern and/or conduction system abnormality, in absence of coronary artery disease should raise suspicion. We present a case of transthyretin related cardiac amyloidosis and discuss the key clinical and diagnostic findings along with review of existing literature regarding its management and outcomes.

4.
J Interv Card Electrophysiol ; 45(2): 219-23, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26768264

RESUMEN

BACKGROUND: Subcutaneous implantable cardioverter-defibrillator (S-ICD) provides potential benefits in patients on hemodialysis (HD) by reducing the risk of blood stream infection and preserving vascular access sites. We evaluated the safety and efficacy of S-ICD in patients with end-stage renal disease (ESRD) on HD. METHODS: All consecutive patients implanted with S-ICD between October 2012 and April 2015 at our high-volume center were included in this retrospective, single-center study. Baseline demographics, procedural details, and short- as well as long-term outcomes were compared between patients on HD and not on HD. RESULTS: A total of 86 S-ICDs were implanted at our institution during the study period. Eighteen (21%) patients were on HD at the time of implant. HD patients were more likely to be implanted for secondary prevention. There was no statistically significant difference in procedural complications between the two groups. HD patients had a longer duration hospital stay after implant (3.6 ± 5.14 vs. 1.69 ± 2.29 days, p = 0.021). During a mean follow-up of 205 ± 208 days in the HD cohort and 242 ± 238 days in the non-HD cohort (p = 0.268), there was no device or blood stream infection in the HD group, compared with five device infections in the non-HD group. The incidence of inappropriate shocks was similar in both groups. All appropriate shocks were successful in terminating ventricular tachyarrhythmias in both groups. Patients on hemodialysis had worse inpatient as well as long-term mortality after S-ICD implant, compared with non-HD patients. CONCLUSIONS: Our study demonstrates the safety and efficacy of S-ICD in patients on HD. Despite representing a sicker patient population, HD patients implanted with S-ICD had similar procedural outcomes and inappropriate shocks. There was no device or blood stream-related infection in HD patients. All appropriate shocks for ventricular arrhythmias in HD patients were successful.


Asunto(s)
Desfibriladores Implantables/estadística & datos numéricos , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/prevención & control , Fallo Renal Crónico/mortalidad , Fallo Renal Crónico/terapia , Diálisis Renal/mortalidad , Comorbilidad , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Pennsylvania/epidemiología , Prevalencia , Implantación de Prótesis/mortalidad , Implantación de Prótesis/estadística & datos numéricos , Diálisis Renal/estadística & datos numéricos , Insuficiencia Renal , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA