1.
ACS Nano ; 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39058962

RESUMEN

In the Fourth Industrial Revolution, as the connection between objects and people becomes increasingly important, interest in wearable optoelectronic device-based medical diagnosis is on the rise. Pulse oximetry sensors based on a fiber platform, which is the smallest unit of clothing, could be considered an attractive candidate for this application. In this study, red and green quantum-dot light-emitting fibers (QDLEFs) based on a 250 µm-diameter 1-dimensional fiber were successfully implemented, achieving high current efficiencies of approximately 22.46 mW/sr/A and 23.6 mW/sr/A and narrow full-width at half-maximum (FWHM) of about 33 nm, respectively. In addition, its omnidirectional flexibility was confirmed through a vertical and lateral bending test with 0.92% strain. By employing a transparent and flexible elastomer, a wearable pulse oximeter incorporating QDLEFs was successfully demonstrated for oxygen saturation level (SpO2) monitoring on finger and wrist. It was demonstrated to be washable, and could be operated for up to about 18 h. Due to the elastomer and bottom emission, it exhibited excellent wear resistance characteristics in a 50 cycle reciprocating test conducted at about 2180.43 kPa with 220-grit abrasive paper sheet. A theoretical investigation based on modified photon diffusion analysis (MPDA) modeling also determined that using narrow FWHM light sources, such as QDLEFs, improves the resolution and accuracy of SpO2 monitoring. Accordingly, the proposed QDLEF showed distinguished potential as an all-in-one clothing type pulse oximetry.

2.
Npj Flex Electron ; 7(1): 15, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36945320

RESUMEN

Increasing demand for real-time healthcare monitoring is leading to advances in thin and flexible optoelectronic device-based wearable pulse oximetry. Most previous studies have used OLEDs for this purpose, but did not consider the side effects of broad full-width half-maximum (FWHM) characteristics and single substrates. In this study, we performed SpO2 measurement using a fiber-based quantum-dot pulse oximetry (FQPO) system capable of mass production with a transferable encapsulation technique, and a narrow FWHM of about 30 nm. Based on analyses we determined that uniform angular narrow FWHM-based light sources are important for accurate SpO2 measurements through multi-layer structures and human skin tissues. The FQPO was shown to have improved photoplethysmogram (PPG) signal sensitivity with no waveguide-mode noise signal, as is typically generated when using a single substrate (30-50%). We successfully demonstrate improved SpO2 measurement accuracy as well as all-in-one clothing-type pulse oximetry with FQPO.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA