Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Lab Hematol ; 45(5): 707-716, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37403230

RESUMEN

INTRODUCTION: Verification of blood collection tubes is essential for clinical laboratories. The aim of this study was to assess performance of candidate tubes from four alternative suppliers for routine diagnostic haematology testing during an impending global shortage of blood collection tubes. METHODS: A multicentre verification study was performed in Cape Town, South Africa. Blood from 300 healthy volunteers was collected into K2 EDTA and sodium citrate tubes of BD Vacutainer® comparator tubes and one of four candidate tubes (Vacucare, Vacuette®, V-TUBE™ and Vacutest®). A technical verification was performed, which included tube physical properties and safety. Routine haematology testing was performed for clinical verification. RESULTS: Vacucare tubes did not have a fill-line indicator, Vacuette® tubes had external blood contamination on the caps post-venesection and Vacutest® tubes had hard rubber stoppers. K2 EDTA tubes of Vacuette®, Vacucare and Vacutest® performed similarly to the comparator. Unacceptable constant bias was seen for PT in Vacucare (95% CI -2.38 to -0.10), Vacutest® (95% CI -1.91 to -0.49) and Vacuette® (95% CI 0.10-1.84) tubes and for aPTT in Vacuette® (95% CI 0.22-2.00) and V-TUBE™ (95% CI -2.88 to -0.44). Unacceptable %bias was seen for aPTT in Vacucare (95% CI 2.78-4.59) and Vacutest® tubes (95% CI 2.53-3.82; desirable ±2.30), and in V-TUBE™ for mean cell volume (95% CI 1.15-1.47, desirable ±0.95%) and mean cell haemoglobin concentration (95% CI -1.65 to -0.93, desirable ±0.43%). CONCLUSION: Blood collection tubes introduce variability to routine haematology results. We recommend that laboratories use one brand of tube. Verification of new candidate tubes should be performed to ensure consistency and reliable reporting of results.


Asunto(s)
Hematología , Laboratorios , Humanos , Ácido Edético , Sudáfrica , Recolección de Muestras de Sangre/métodos
2.
Biochem Med (Zagreb) ; 33(2): 020802, 2023 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-37324116

RESUMEN

Renal tubular acidosis (RTA) is a rare disorder that can be inherited or acquired, and results in an inability of the kidneys to maintain normal acid-base balance. We present a case of recurrent, severe hypokalaemia and rhabdomyolysis in a young woman who had an associated normal anion gap metabolic acidosis and was subsequently diagnosed with distal RTA associated with Hashimoto's thyroiditis. Distal RTA associated with Hashimoto's thyroiditis is rare and probably develops because of autoimmune-mediated mechanisms, causing an inability of the H+-ATPase pump in alpha-intercalated cells of the cortical collecting duct to secrete H+, with subsequent failure of urinary acidification. In this case, this hypothesis was supported by the exclusion of common genetic mutations associated with distal RTA. We illustrate that utilizing a systematic, physiology-based approach for challenging electrolyte and acid-base disorders enables identification of the root cause and underlying disease mechanisms.


Asunto(s)
Acidosis Tubular Renal , Acidosis , Hipopotasemia , Tiroiditis , Femenino , Humanos , Acidosis Tubular Renal/complicaciones , Acidosis Tubular Renal/diagnóstico , Hipopotasemia/complicaciones , Mutación , Tiroiditis/complicaciones
3.
BMC Nephrol ; 21(1): 32, 2020 01 30.
Artículo en Inglés | MEDLINE | ID: mdl-32000712

RESUMEN

BACKGROUND: To assess whether the agreement between fasting glucose and glycated proteins is affected by chronic kidney disease (CKD) in a community-based sample of 1621 mixed-ancestry South Africans. METHODS: CKD was defined as an estimated glomerular filtration rate < 60 ml/min/1.73 m2. Fasting plasma glucose and haemoglobin A1c (HbA1c) concentrations were measured by enzymatic hexokinase method and high-performance liquid chromatography, respectively, with fructosamine and glycated albumin measured by immunoturbidimetry and enzymatic method, respectively. RESULTS: Of those with CKD (n = 96), 79, 16 and 5% where in stages 3, 4 and 5, respectively. Those with CKD had higher levels of HbA1c (6.2 vs. 5.7%; p < 0.0001), glycated albumin (15.0 vs. 13.0%; p < 0.0001) and fructosamine levels (269.7 vs. 236.4 µmol/l; p < 0.0001), compared to those without CKD. Higher fasting glucose levels were associated with higher HbA1c, glycated albumin and fructosamine, independent of age, gender, and CKD. However, the association with HbA1c and glycated albumin differed by CKD status, at the upper concentrations of the respective markers (interaction term for both: p ≤ 0.095). CONCLUSION: Our results suggest that although HbA1c and glycated albumin perform acceptably under conditions of normoglycaemia, these markers correlate less well with blood glucose levels in people with CKD who are not on dialysis.


Asunto(s)
Glucemia/metabolismo , Fructosamina/sangre , Hemoglobina Glucada/metabolismo , Insuficiencia Renal Crónica/sangre , Albúmina Sérica/metabolismo , Adulto , Anciano , Biomarcadores/sangre , Estudios de Casos y Controles , Estudios Transversales , Ayuno , Femenino , Productos Finales de Glicación Avanzada , Humanos , Fallo Renal Crónico/sangre , Fallo Renal Crónico/fisiopatología , Fallo Renal Crónico/terapia , Masculino , Persona de Mediana Edad , Diálisis Renal , Insuficiencia Renal Crónica/fisiopatología , Insuficiencia Renal Crónica/terapia , Albúmina Sérica Glicada
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...