Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 35
1.
J Clin Sleep Med ; 2024 May 09.
Article En | MEDLINE | ID: mdl-38722264

STUDY OBJECTIVES: Excessive daytime sleepiness (EDS) in patients with obstructive sleep apnea (OSA) is poorly explained by standard clinical sleep architecture metrics. We hypothesized that reduced sleep stage continuity mediates this connection independently from standard sleep architecture metrics. METHODS: 1,907 patients with suspected OSA with daytime sleepiness complaints underwent in-lab diagnostic polysomnography and next-day Multiple Sleep Latency Test (MSLT). Sleep architecture was evaluated with novel sleep-stage continuity quantifications (mean sleep stage duration and probability of remaining in each sleep stage), and conventional metrics (total N1, N2, N3 and REM times; and sleep onset latency). Multivariate analyses were utilized to identify variables associated with moderate EDS (5 ≤ mean daytime sleep latency (MSL) ≤ 10 minutes) and severe EDS (MSL < 5 minutes). RESULTS: Compared to those without EDS, participants with severe EDS had lower N3 sleep continuity (mean N3 period duration 10.4 vs 13.7 minutes, p<0.05), less N3 time (53.8 vs 76.5 minutes, p<0.05); greater total sleep time (374.0 vs 352.5 minutes, p<0.05) and greater N2 time (227.5 vs 186.8 minutes, p<0.05). After adjusting for standard sleep architecture metrics using multivariate logistic regression, decreased mean wake and N3 period duration, and the decreased probability of remaining in N2 and N3 sleep remained significantly associated with severe EDS, while the decreased probability of remaining in wake and N2 sleep were associated with moderate EDS. CONCLUSIONS: Patients with OSA with EDS experience lower sleep continuity, noticeable especially during N3 sleep and wake. Sleep-stage continuity quantifications assist in characterizing the sleep architecture and are associated with objective daytime sleepiness highlighting the need for more detailed evaluations of sleep quality.

2.
IEEE J Transl Eng Health Med ; 12: 328-339, 2024.
Article En | MEDLINE | ID: mdl-38444399

OBJECTIVE: The aim of this study was to assess how the photoplethysmogram frequency and amplitude responses to arousals from sleep differ between arousals caused by apneas and hypopneas with and without blood oxygen desaturations, and spontaneous arousals. Stronger arousal causes were hypothesized to lead to larger and faster responses. METHODS AND PROCEDURES: Photoplethysmogram signal segments during and around respiratory and spontaneous arousals of 876 suspected obstructive sleep apnea patients were analyzed. Logistic functions were fit to the mean instantaneous frequency and instantaneous amplitude of the signal to detect the responses. Response intensities and timings were compared between arousals of different causes. RESULTS: The majority of the studied arousals induced photoplethysmogram responses. The frequency response was more intense ([Formula: see text]) after respiratory than spontaneous arousals, and after arousals caused by apneas compared to those caused by hypopneas. The amplitude response was stronger ([Formula: see text]) following hypopneas associated with blood oxygen desaturations compared to those that were not. The delays of these responses relative to the electroencephalogram arousal start times were the longest ([Formula: see text]) after arousals caused by apneas and the shortest after spontaneous arousals and arousals caused by hypopneas without blood oxygen desaturations. CONCLUSION: The presence and type of an airway obstruction and the presence of a blood oxygen desaturation affect the intensity and the timing of photoplethysmogram responses to arousals from sleep. CLINICAL IMPACT: The photoplethysmogram responses could be used for detecting arousals and assessing their intensity, and the individual variation in the response intensity and timing may hold diagnostically significant information.


Photoplethysmography , Sleep Apnea, Obstructive , Humans , Sleep , Sleep Apnea, Obstructive/diagnosis , Arousal , Oxygen
3.
Sleep Adv ; 5(1): zpad054, 2024.
Article En | MEDLINE | ID: mdl-38264141

Polygraphy (PG) is often used to diagnose obstructive sleep apnea (OSA). However, it does not use electroencephalography, and therefore cannot estimate sleep time or score arousals and related hypopneas. Consequently, the PG-derived respiratory event index (REI) differs from the polysomnography (PSG)-derived apnea-hypopnea index (AHI). In this study, we comprehensively analyzed the differences between AHI and REI. Conventional AHI and REI were calculated based on total sleep time (TST) and total analyzed time (TAT), respectively, from two different PSG datasets (n = 1561). Moreover, TAT-based AHI (AHITAT) and TST-based REI (REITST) were calculated. These indices were compared keeping AHI as the gold standard. The REI, AHITAT, and REITST were significantly lower than AHI (p < 0.0001, p ≤ 0.002, and p ≤ 0.01, respectively). The total classification accuracy of OSA severity based on REI was 42.1% and 72.8% for two datasets. Based on AHITAT, the accuracies were 68.4% and 85.9%, and based on REITST, they were 65.9% and 88.5% compared to AHI. AHI was most correlated with REITST (r = 0.98 and r = 0.99 for the datasets) and least with REI (r = 0.92 and r = 0.97). Compared to AHI, REI had the largest mean absolute errors (13.9 and 6.7) and REITST the lowest (5.9 and 1.9). REI had the lowest sensitivities (42.1% and 72.8%) and specificities (80.7% and 90.9%) in both datasets. Based on these present results, REI underestimates AHI. Furthermore, these results indicate that arousal-related hypopneas are an important measure for accurately classifying OSA severity.

4.
Sleep Med Rev ; 73: 101874, 2024 Feb.
Article En | MEDLINE | ID: mdl-38091850

Sleep-disordered breathing, ranging from habitual snoring to severe obstructive sleep apnea, is a prevalent public health issue. Despite rising interest in sleep and awareness of sleep disorders, sleep research and diagnostic practices still rely on outdated metrics and laborious methods reducing the diagnostic capacity and preventing timely diagnosis and treatment. Consequently, a significant portion of individuals affected by sleep-disordered breathing remain undiagnosed or are misdiagnosed. Taking advantage of state-of-the-art scientific, technological, and computational advances could be an effective way to optimize the diagnostic and treatment pathways. We discuss state-of-the-art multidisciplinary research, review the shortcomings in the current practices of SDB diagnosis and management in adult populations, and provide possible future directions. We critically review the opportunities for modern data analysis methods and machine learning to combine multimodal information, provide a perspective on the pitfalls of big data analysis, and discuss approaches for developing analysis strategies that overcome current limitations. We argue that large-scale and multidisciplinary collaborative efforts based on clinical, scientific, and technical knowledge and rigorous clinical validation and implementation of the outcomes in practice are needed to move the research of sleep-disordered breathing forward, thus increasing the quality of diagnostics and treatment.


Sleep Apnea Syndromes , Adult , Humans , Sleep Apnea Syndromes/diagnosis , Sleep Apnea Syndromes/therapy , Snoring
5.
J Sleep Res ; 33(1): e13956, 2024 Feb.
Article En | MEDLINE | ID: mdl-37309714

Determining sleep stages accurately is an important part of the diagnostic process for numerous sleep disorders. However, as the sleep stage scoring is done manually following visual scoring rules there can be considerable variation in the sleep staging between different scorers. Thus, this study aimed to comprehensively evaluate the inter-rater agreement in sleep staging. A total of 50 polysomnography recordings were manually scored by 10 independent scorers from seven different sleep centres. We used the 10 scorings to calculate a majority score by taking the sleep stage that was the most scored stage for each epoch. The overall agreement for sleep staging was κ = 0.71 and the mean agreement with the majority score was 0.86. The scorers were in perfect agreement in 48% of all scored epochs. The agreement was highest in rapid eye movement sleep (κ = 0.86) and lowest in N1 sleep (κ = 0.41). The agreement with the majority scoring varied between the scorers from 81% to 91%, with large variations between the scorers in sleep stage-specific agreements. Scorers from the same sleep centres had the highest pairwise agreements at κ = 0.79, κ = 0.85, and κ = 0.78, while the lowest pairwise agreement between the scorers was κ = 0.58. We also found a moderate negative correlation between sleep staging agreement and the apnea-hypopnea index, as well as the rate of sleep stage transitions. In conclusion, although the overall agreement was high, several areas of low agreement were also found, mainly between non-rapid eye movement stages.


Sleep Apnea Syndromes , Sleep , Humans , Observer Variation , Reproducibility of Results , Sleep Stages , Sleep Apnea Syndromes/diagnosis
6.
J Sleep Res ; 33(2): e13977, 2024 Apr.
Article En | MEDLINE | ID: mdl-37400248

Sleep recordings are increasingly being conducted in patients' homes where patients apply the sensors themselves according to instructions. However, certain sensor types such as cup electrodes used in conventional polysomnography are unfeasible for self-application. To overcome this, self-applied forehead montages with electroencephalography and electro-oculography sensors have been developed. We evaluated the technical feasibility of a self-applied electrode set from Nox Medical (Reykjavik, Iceland) through home sleep recordings of healthy and suspected sleep-disordered adults (n = 174) in the context of sleep staging. Subjects slept with a double setup of conventional type II polysomnography sensors and self-applied forehead sensors. We found that the self-applied electroencephalography and electro-oculography electrodes had acceptable impedance levels but were more prone to losing proper skin-electrode contact than the conventional cup electrodes. Moreover, the forehead electroencephalography signals recorded using the self-applied electrodes expressed lower amplitudes (difference 25.3%-43.9%, p < 0.001) and less absolute power (at 1-40 Hz, p < 0.001) than the polysomnography electroencephalography signals in all sleep stages. However, the signals recorded with the self-applied electroencephalography electrodes expressed more relative power (p < 0.001) at very low frequencies (0.3-1.0 Hz) in all sleep stages. The electro-oculography signals recorded with the self-applied electrodes expressed comparable characteristics with standard electro-oculography. In conclusion, the results support the technical feasibility of the self-applied electroencephalography and electro-oculography for sleep staging in home sleep recordings, after adjustment for amplitude differences, especially for scoring Stage N3 sleep.


Electroencephalography , Sleep , Adult , Humans , Polysomnography/methods , Feasibility Studies , Electrooculography/methods , Sleep Stages , Electrodes
7.
J Sleep Res ; 33(2): e13988, 2024 Apr.
Article En | MEDLINE | ID: mdl-37448111

Oxygen saturation (SpO2 )-based parameters are more strongly linked to impaired daytime vigilance than the conventional diagnostic metrics in patients with obstructive sleep apnea (OSA). However, whether the association between SpO2 -based parameters and impaired daytime vigilance is modulated by sex, remains unknown. Hence, we investigated the interplay between sex and detailed SpO2 -based metrics and their association with impaired vigilance in patients with OSA. The study population consisted of 855 (473 males, 382 females) patients with suspected OSA who underwent overnight polysomnography and psychomotor vigilance task (PVT). The population was grouped by sex and divided into quartiles (Q1-Q4) based on median reaction times (RTs) in the PVT. In addition to conventional diagnostic metrics, desaturation severity (DesSev), fall severity (FallSev), and recovery severity (RecovSev) were compared between the sexes and between the best (Q1) and worst (Q4) performing quartiles by using cumulative distribution functions (CDFs). Additionally, sex-specific covariate-adjusted linear regression models were used to investigate the connection between the parameters and RTs. The CDFs showed significantly higher hypoxic load in Q4 in males compared to females. In addition, the DesSev (ß = 8.05, p < 0.01), FallSev (ß = 6.48, p = 0.02), RecovSev (ß = 9.13, p < 0.01), and Oxygen Desaturation Index (ß = 12.29, p < 0.01) were associated with increased RTs only in males. Conversely, the Arousal Index (ß = 10.75-11.04, p < 0.01) was associated with impaired vigilance in females. The severity of intermittent hypoxaemia was strongly associated with longer RTs in males whereas the Arousal Index had the strongest association in females. Thus, the impact of hypoxic load on impaired vigilance seems to be stronger in males than females.


Sleep Apnea Syndromes , Sleep Apnea, Obstructive , Male , Female , Humans , Reaction Time , Sleep Apnea Syndromes/complications , Sleep Apnea, Obstructive/complications , Hypoxia/complications , Severity of Illness Index
8.
Ann Noninvasive Electrocardiol ; 29(1): e13101, 2024 01.
Article En | MEDLINE | ID: mdl-38031823

BACKGROUND: Obesity is a global issue with a major impact on cardiovascular health. This study explores how obesity influences nocturnal cardiac electrophysiology in suspected obstructive sleep apnea (OSA) patients. METHODS: We randomly selected 12 patients from each of the five World Health Organization body mass index (BMI) classifications groups (ntotal = 60) while keeping the group's age and sex matched. We evaluated 1965 nocturnal electrocardiography (ECG) samples (10 s) using modified lead II recorded during normal saturation conditions. R-wave peaks were detected and confirmed using dedicated software, with the exclusion of ventricular extrasystoles and artifacts. The duration of waves and intervals was manually marked. The average electric potential graphs were computed for each segment. Thresholds for abnormal ECG waveforms were P-wave > 120 ms, PQ interval > 200 ms, QRS complex > 120 ms for, and QTc > 440 ms. RESULTS: Obesity was significantly (p < .05) associated with prolonged conduction times. Compared to the normal weight (18.5 ≤ BMI < 25) group, the morbidly obese patients (BMI ≥ 40) had a significantly longer P-wave duration (101.7 vs. 117.2 ms), PQ interval (175.8 vs. 198.0 ms), QRS interval (89.9 vs. 97.7 ms), and QTc interval (402.8 vs. 421.2 ms). We further examined ECG waveform prolongations related to BMI. Compared to other patient groups, the morbidly obese patients had the highest number of ECG segments with PQ interval (44% of the ECG samples), QRS duration (14%), and QTc duration (20%) above the normal limits. CONCLUSIONS: Morbid obesity predisposes patients to prolongation of cardiac conduction times. This might increase the risk of arrhythmias, stroke, and even sudden cardiac death.


Obesity, Morbid , Sleep Apnea, Obstructive , Humans , Electrocardiography , Obesity, Morbid/complications , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Death, Sudden, Cardiac , Sleep Apnea, Obstructive/complications , Sleep Apnea, Obstructive/diagnosis
9.
J Sleep Res ; : e14127, 2023 Dec 26.
Article En | MEDLINE | ID: mdl-38148632

We investigated arousal scoring agreement within full-night polysomnography in a multi-centre setting. Ten expert scorers from seven centres annotated 50 polysomnograms using the American Academy of Sleep Medicine guidelines. The agreement between arousal indexes (ArIs) was investigated using intraclass correlation coefficients (ICCs). Moreover, kappa statistics were used to evaluate the second-by-second agreement in whole recordings and in different sleep stages. Finally, arousal clusters, that is, periods with overlapping arousals by multiple scorers, were extracted. The overall similarity of the ArIs was fair (ICC = 0.41), varying from poor to excellent between the scorer pairs (ICC = 0.04-0.88). The ArI similarity was better in respiratory (ICC = 0.65) compared with spontaneous (ICC = 0.23) arousals. The overall second-by-second agreement was fair (Fleiss' kappa = 0.40), varying from poor to substantial depending on the scorer pair (Cohen's kappa = 0.07-0.68). Fleiss' kappa increased from light to deep sleep (0.45, 0.45, and 0.53 for stages N1, N2, and N3, respectively), was moderate in the rapid eye movement stage (0.48), and the lowest in the wake stage (0.25). Over a half of the arousal clusters were scored by one or two scorers, and less than a third by at least five scorers. In conclusion, the scoring agreement varied depending on the arousal type, sleep stage, and scorer pair, but was overall relatively low. The most uncertain areas were related to spontaneous arousals and arousals scored in the wake stage. These results indicate that manual arousal scoring is generally not reliable, and that changes are needed in the assessment of sleep fragmentation for clinical and research purposes.

10.
Front Neurol ; 14: 1239016, 2023.
Article En | MEDLINE | ID: mdl-37693751

Obstructive Sleep Apnea (OSA) arises due to periodic blockage of the upper airway (UA) during sleep, as negative pressure generated during inspiration overcomes the force exerted by the UA dilator muscles to maintain patency. This imbalance is primarily seen in individuals with a narrowed UA, attributable to factors such as inherent craniofacial anatomy, neck fat accumulation, and rostral fluid shifts in the supine posture. Sleep-induced attenuation of UA dilating muscle responsiveness, respiratory instability, and high loop gain further exacerbate UA obstruction. The widespread comorbidity profile of OSA, encompassing cardiovascular, metabolic, and neuropsychiatric domains, suggests complex bidirectional relationships with conditions like heart failure, stroke, and metabolic syndrome. Recent advances have delineated distinct OSA phenotypes beyond mere obstruction frequency, showing links with specific symptomatic manifestations. It is vital to bridge the gap between measurable patient characteristics, phenotypes, and underlying pathophysiological traits to enhance our understanding of OSA and its interplay with related outcomes. This knowledge could stimulate the development of tailored therapies targeting specific phenotypic and pathophysiological endotypes. This review aims to elucidate the multifaceted pathophysiology of OSA, focusing on the relationships between UA anatomy, functional traits, clinical manifestations, and comorbidities. The ultimate objective is to pave the way for a more personalized treatment paradigm in OSA, offering alternatives to continuous positive airway pressure therapy for selected patients and thereby optimizing treatment efficacy and adherence. There is an urgent need for personalized treatment strategies in the ever-evolving field of sleep medicine, as we progress from a 'one-size-fits-all' to a 'tailored-therapy' approach.

11.
Front Neurol ; 14: 1162998, 2023.
Article En | MEDLINE | ID: mdl-37122306

Introduction: Visual sleep scoring has several shortcomings, including inter-scorer inconsistency, which may adversely affect diagnostic decision-making. Although automatic sleep staging in adults has been extensively studied, it is uncertain whether such sophisticated algorithms generalize well to different pediatric age groups due to distinctive EEG characteristics. The preadolescent age group (10-13-year-olds) is relatively understudied, and thus, we aimed to develop an automatic deep learning-based sleep stage classifier specifically targeting this cohort. Methods: A dataset (n = 115) containing polysomnographic recordings of Icelandic preadolescent children with sleep-disordered breathing (SDB) symptoms, and age and sex-matched controls was utilized. We developed a combined convolutional and long short-term memory neural network architecture relying on electroencephalography (F4-M1), electrooculography (E1-M2), and chin electromyography signals. Performance relative to human scoring was further evaluated by analyzing intra- and inter-rater agreements in a subset (n = 10) of data with repeat scoring from two manual scorers. Results: The deep learning-based model achieved an overall cross-validated accuracy of 84.1% (Cohen's kappa κ = 0.78). There was no meaningful performance difference between SDB-symptomatic (n = 53) and control subgroups (n = 52) [83.9% (κ = 0.78) vs. 84.2% (κ = 0.78)]. The inter-rater reliability between manual scorers was 84.6% (κ = 0.78), and the automatic method reached similar agreements with scorers, 83.4% (κ = 0.76) and 82.7% (κ = 0.75). Conclusion: The developed algorithm achieved high classification accuracy and substantial agreements with two manual scorers; the performance metrics compared favorably with typical inter-rater reliability between manual scorers and performance reported in previous studies. These suggest that our algorithm may facilitate less labor-intensive and reliable automatic sleep scoring in preadolescent children.

12.
IEEE Trans Biomed Eng ; 70(7): 2122-2130, 2023 07.
Article En | MEDLINE | ID: mdl-37018722

OBJECTIVE: We aimed to investigate how acute and long-term effects of atrial arrhythmias affect the desaturation severity and characteristics determined from the oxygen saturation signal in obstructive sleep apnea (OSA) patients. METHODS: 520 suspected OSA patients were included in retrospective analyses. Eight desaturation area and slope parameters were calculated from blood oxygen saturation signals recorded during polysomnographic recordings. Patients were grouped based on whether they had previously diagnosed atrial arrhythmia (i.e., atrial fibrillation (AFib) or atrial flutter) or not. Furthermore, patients with a previous atrial arrhythmia diagnosis were sub-grouped based on whether they had continuous AFib or sinus rhythm during the polysomnographic recordings. Empirical cumulative distribution functions and linear mixed models were utilized to investigate the connection between diagnosed atrial arrhythmia and the desaturation characteristics. RESULTS: Patients with previous atrial arrhythmia diagnosis had greater desaturation recovery area when the 100% oxygen saturation baseline reference was considered (ß = 0.150--0.127, p ≤ 0.039) and more gradual recovery slopes (ß = -0.181 to -0.199, p < 0.004) than patients without a previous atrial arrhythmia diagnosis. Furthermore, patients with AFib had more gradual oxygen saturation fall and recovery slopes than patients with sinus rhythm. CONCLUSION: Desaturation recovery characteristics in the oxygen saturation signal contains essential information about the cardiovascular response to hypoxemic periods. SIGNIFICANCE: More comprehensive consideration of the desaturation recovery section could provide more detailed information about OSA severity, for example when developing new diagnostic parameters.


Atrial Fibrillation , Sleep Apnea, Obstructive , Humans , Atrial Fibrillation/diagnosis , Retrospective Studies , Polysomnography , Sleep Apnea, Obstructive/diagnosis , Oxygen
13.
IEEE Trans Biomed Eng ; 70(5): 1704-1714, 2023 05.
Article En | MEDLINE | ID: mdl-36441886

OBJECTIVE: Obstructive sleep apnea (OSA) is diagnosed using the apnea-hypopnea index (AHI), which is the average number of respiratory events per hour of sleep. Recently, machine learning algorithms for automatic AHI assessment have been developed, but many of them do not consider the individual sleep stages or events. In this study, we aimed to develop a deep learning model to simultaneously score both sleep stages and respiratory events. The hypothesis was that the scoring and subsequent AHI calculation could be performed utilizing pulse oximetry data only. METHODS: Polysomnography recordings of 877 individuals with suspected OSA were used to train the deep learning models. The same architecture was trained with three different input signal combinations (model 1: photoplethysmogram (PPG) and oxygen saturation (SpO 2); model 2: PPG, SpO 2, and nasal pressure; model 3: SpO 2, nasal pressure, electroencephalogram (EEG), oronasal thermocouple, and respiratory belts). RESULTS: Model 1 reached comparative performance with models 2 and 3 for estimating the AHI (model 1 intraclass correlation coefficient (ICC) = 0.946; model 2 ICC = 0.931; model 3 ICC = 0.945), and REM-AHI (model 1 ICC = 0.912; model 2 ICC = 0.921; model 3 ICC = 0.883). The automatic sleep staging accuracies (wake/N1/N2/N3/REM) were 69%, 70%, and 79% with models 1, 2, and 3, respectively. CONCLUSION: AHI can be estimated using pulse oximetry-based automatic scoring. Explicit scoring of sleep stages and respiratory events allows visual validation of the automatic analysis, and provides information on OSA phenotypes. SIGNIFICANCE: Automatic scoring of sleep stages and respiratory events with a simple pulse oximetry setup could allow cost-effective, large-scale screening of OSA.


Deep Learning , Sleep Apnea, Obstructive , Humans , Sleep Apnea, Obstructive/diagnosis , Sleep , Sleep Stages , Polysomnography
14.
J Sleep Res ; 32(3): e13803, 2023 06.
Article En | MEDLINE | ID: mdl-36482788

Obstructive sleep apnea (OSA)-related intermittent hypoxaemia is a potential risk factor for different OSA comorbidities, for example cardiovascular disease. However, conflicting results are found as to whether intermittent hypoxaemia is associated with impaired vigilance. Therefore, we aimed to investigate how desaturation characteristics differ between the non-impaired vigilance and impaired vigilance patient groups formed based on psychomotor vigilance task (PVT) performance and compared with traditional OSA severity parameters. The study population comprised 863 patients with suspected OSA who underwent a PVT test before polysomnography. The conventional OSA parameters, for example, the apnea-hypopnea index, oxygen desaturation index, and arousal index were computed. Furthermore, the median desaturation area, fall area, recovery area, and desaturation depth were computed with the pre-event baseline reference and with reference to the 100% oxygen saturation level. Patients were grouped into best- and worst-performing quartiles based on the number of lapses in PVT (Q1: PVT lapses <5 and Q4: PVT lapses >36). The association between parameters and impaired vigilance was evaluated by cumulative distribution functions (CDFs) and binomial logistic regression. Based on the CDFs, patients in Q4 had larger desaturation areas, recovery areas, and deeper desaturations when these were referenced to 100% saturation compared with Q1. The odds ratio (OR) of the median desaturation area (OR = 1.56), recovery area (OR = 1.71), and depth (OR = 1.65) were significantly elevated in Q4 in regression models. However, conventional OSA parameters were not significantly associated with impaired vigilance (ORs: 0.79-1.09). Considering desaturation parameters with a 100% SpO2 reference in the diagnosis of OSA could provide additional information on the severity of OSA and related daytime vigilance impairment.


Sleep Apnea, Obstructive , Humans , Wakefulness , Psychomotor Performance , Hypoxia/complications , Arousal , Oxygen
15.
Adv Exp Med Biol ; 1384: 205-218, 2022.
Article En | MEDLINE | ID: mdl-36217086

Pulse oximeters are routinely used in various medical-grade and consumer-grade applications. They can be used to estimate, for example, blood oxygen saturation, autonomic nervous system activity and cardiac function, blood pressure, sleep quality, and recovery through the recording of photoplethysmography signal. Medical-grade devices often record red and infra-red light-based photoplethysmography signals while smartwatches and other consumer-grade devices usually rely on a green light. At its simplest, a pulse oximeter can consist of one or two photodiodes and a photodetector attached, for example, a fingertip or earlobe. These sensors are used to record light absorption in a medium as a function of time. This time-varying absorption information is used to form a photoplethysmography signal. In this chapter, we discuss the working principles of pulse oximeters and the formation of the photoplethysmography signal. We will further discuss the advantages and disadvantages of pulse oximeters, which kind of applications exist in the medical field, and how pulse oximeters are utilized in daily health monitoring.


Oximetry , Photoplethysmography , Blood Pressure , Fingers , Oxygen
16.
Sleep Med ; 100: 479-486, 2022 12.
Article En | MEDLINE | ID: mdl-36257201

OBJECTIVES/BACKGROUND: Interest in using blood oxygen desaturations in the diagnostics of sleep apnea has risen in recent years. However, no standardized criteria for desaturation scoring exist which complicates the drawing of solid conclusions from literature. PATIENTS/METHODS: We investigated how different desaturation scoring criteria affect the severity of nocturnal hypoxic load and the prediction of impaired daytime vigilance in 845 patients. Desaturations were scored based on three features: 1) minimum oxygen saturation drop during the event (2-20%, 1% interval), 2) minimum duration of the event (2-20s, 1s interval), and 3) maximum plateau duration within the event (5-60s, 5s interval), resulting in 4332 different scoring criteria. The hypoxic load was described with oxygen desaturation index (ODI), desaturation severity (DesSev), and desaturation duration (DesDur) parameters. Association between hypoxic load and impaired vigilance was investigated with covariate-adjusted area under curve (AUC) analyses by dividing patients into normal (≤5 lapses) and impaired (≥36 lapses) vigilance groups based on psychomotor vigilance task performance. RESULTS: The severity of hypoxic load varied greatly between different scoring criteria. For example, median ODI ranged between 0.4 and 12.9 events/h, DesSev 0.01-0.23 %-point, and DesDur 0.3-9.6 %-point when the minimum transient drop criterion of 3% was used and other two features were altered. Overall, the minimum transient drop criterion had the largest effect on parameter values. All models with differently determined parameters predicted impaired vigilance moderately (AUC = 0.722-0.734). CONCLUSIONS: Desaturation scoring criteria greatly affected the severity of hypoxic load. However, the difference in the prediction of impaired vigilance between different criteria was rather small.


Hypoxia , Sleep Apnea Syndromes , Humans , Hypoxia/complications , Sleep Apnea Syndromes/complications , Oxygen
17.
Sci Rep ; 12(1): 15859, 2022 09 23.
Article En | MEDLINE | ID: mdl-36151239

Sleep research often relies on large retrospective clinical datasets. However, as the data is usually stored in proprietary formats specific for each sleep software, the raw data cannot be easily accessed and analyzed with external tools. While the raw data can usually be exported to more common data formats, this is often a cumbersome and labor-intensive task as it is not required for clinical purposes. Additionally, the recordings often include sensitive patient information which must be removed before the data can be shared or analyzed externally. This anonymization can be difficult to perform manually without the correct tools or knowledge of the file types and how they internally store the data. The STAR sleep recording export software provides a simple tool that can be used to perform the sleep study exports automatically. This allows the user to easily export a batch of sleep studies with minimal effort. In addition, the software can also be used to automatically anonymize the exported sleep recordings allowing researchers to save time and personnel resources as these do not need to be allocated for exporting and anonymizing sleep studies. The software supports Noxturnal, RemLogic, Profusion PSG and Sleepware G3 and it is free and openly available for anyone to download and use.


Sleep , Software , Humans , Polysomnography , Retrospective Studies
18.
BMC Pulm Med ; 22(1): 204, 2022 May 24.
Article En | MEDLINE | ID: mdl-35610617

BACKGROUND: Obstructive sleep apnea (OSA) is associated with vascular diseases from which stroke and sudden cardiac death are the most significant ones. It is known that disturbances of the autonomic nervous system and electrocardiographic changes are seen in patients with a previous cerebrovascular event. However, the pathophysiological cascade between breathing cessations, autonomic regulation, and cardiovascular events is not fully understood. METHODS: We aimed to investigate the acute effect of desaturation on repolarisation in OSA patients with a previous stroke. We retrospectively analysed heart-rate corrected QT (QTc) intervals before, within, and after 975 desaturations in OSA patients with a stroke history and at least moderate sleep apnea (apnea-hypopnea index ≥ 15 events/h, n = 18). For the control population (n = 18), QTc intervals related to 1070 desaturation were analysed. Desaturations were assigned to groups according to their length and duration. Groupwise comparisons and regression analyses were further executed to investigate the influence of desaturation features on repolarization. RESULTS: In the stroke population the QTc prolonged at least 11 ms during 27.1% of desaturations, and over 20 ms during 12.2% of desaturations. QTc was significantly prolonged during longer (> 30 s, p < 0.04) and deeper (> 7%, p < 0.03) desaturations. Less severe desaturations didn't influence QTc. In median, QTc prolonged 7.5 ms during > 45 s desaturations and 7.4 ms during > 9% deep desaturations. In the control population, QTc prolongation was observed but to a significantly lesser extent than in stroke patients. In addition, desaturation duration was found to be an independent predictor of QTc prolongation (ß = 0.08, p < 0.001) among all study patients. CONCLUSIONS: We demonstrated that longer (> 30 s) and deeper (> 7%) desaturations prolong QTc in patients with stroke history. A significant proportion of desaturations produced clinically relevant QTc prolongation. As it is known that a long QTc interval is associated with lethal arrhythmias, this finding might in part explain the pathophysiological sequelae of cardiovascular mortality in OSA patients with a history of stroke.


Long QT Syndrome , Sleep Apnea Syndromes , Sleep Apnea, Obstructive , Stroke , Electrocardiography , Humans , Long QT Syndrome/complications , Polysomnography , Retrospective Studies , Sleep Apnea Syndromes/complications , Sleep Apnea, Obstructive/complications , Stroke/complications
19.
IEEE Trans Biomed Eng ; 69(4): 1417-1423, 2022 04.
Article En | MEDLINE | ID: mdl-34613906

OBJECTIVE: We aimed to investigate the differences in electroencephalogram (EEG) gamma power (30-40 Hz) of respiratory arousals between varying types and severities of respiratory events, and in different sleep stages. METHODS: Power spectral densities of EEG signals from diagnostic Type I polysomnograms of 869 patients with clinically suspected obstructive sleep apnea were investigated. Arousal gamma powers were compared between sleep stages, and between the type (obstructive apnea and hypopnea) and duration (10-20 s, 20-30 s, and >30 s) of the related respiratory event. Moreover, we investigated whether the presence of a ≥3% blood oxygen desaturation influenced the arousal gamma power. RESULTS: Gamma power of respiratory arousals was the lowest in Stage R sleep and increased from Stage N1 towards Stage N3. Gamma power was higher when the arousals were caused by obstructive apneas compared to hypopneas. Moreover, arousal gamma power increased when the duration of the related apnea increased, whereas an increase in the hypopnea duration did not have a similar effect. Furthermore, respiratory events associated with desaturations increased the arousal gamma power more than respiratory events not associated with desaturations. CONCLUSION: Gamma power of respiratory arousals increased towards deeper sleep and as the severity of the related respiratory event increased in terms of type and duration of obstruction, and presence of desaturation. SIGNIFICANCE: As increased gamma power might indicate a greater shift towards wakefulness, the present findings demonstrate that the respiratory arousal intensity and the magnitude of sleep disruption may vary depending on the event type and severity.


Sleep Apnea Syndromes , Sleep Apnea, Obstructive , Arousal , Electroencephalography , Humans , Polysomnography , Sleep Apnea Syndromes/diagnosis , Sleep Apnea, Obstructive/diagnosis , Sleep Stages
...