Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 7 de 7
1.
Respir Care ; 67(12): 1558-1567, 2022 12.
Article En | MEDLINE | ID: mdl-36100277

BACKGROUND: Clinical diagnosis of ICU-acquired pneumonia after cardiothoracic surgery is challenging. Johanson criteria (chest radiograph infiltrate, purulent tracheal secretions, fever, and leukocytosis) fail in half the cases. A high Clinical Pulmonary Infection Score (CPIS) and ≥ 2-point increase in Sequential Organ Failure Assessment (SOFA) score (SOFA↑ ≥ 2) may improve diagnosis. The aim of the study was to evaluate whether CPIS or SOFA↑ ≥ 2 contributes to predict ICU-acquired pneumonia in subjects after cardiothoracic surgery. METHODS: We used a prospective observational design. Spiegelhalter-Knill-Jones scoring systems including CPIS or SOFA↑ ≥ 2, together with other clinical and laboratory variables, were developed in a derivation cohort. A positive quantitative pulmonary sample culture was required to confirm ICU-acquired pneumonia. Area under the receiver operating characteristic curve (AUROC) was computed for each of the 2 scoring systems. The best system was evaluated in a validation cohort. RESULTS: Derivation and validation cohorts included 172 and 108 subjects, with 410 and 216 suspected ICU-acquired pneumonia episodes, respectively. AUROC was 0.53 ± 0.03 for CPIS (P = .29) and 0.54 ± 0.03 for SOFA↑ ≥ 2 (P = .29). Adding purulent tracheal secretions and leukocytosis to SOFA↑ ≥ 2 (SOFA model) increased AUROC to 0.65 ± 0.03 (P < .001). Adding catecholamine use to CPIS (CPIS model) increased AUROC only slightly, to 0.57 ± 0.03. The probabilities predicted by the SOFA model were reliable, especially when high or low. CONCLUSIONS: A clinical scoring system including at least SOFA↑ ≥ 2 increase barely improved ICU-acquired pneumonia prediction in subjects after cardiothoracic surgery.


Cross Infection , Healthcare-Associated Pneumonia , Pneumonia , Humans , Intensive Care Units , Cross Infection/diagnosis , Multiple Organ Failure , Leukocytosis , Healthcare-Associated Pneumonia/diagnosis , Healthcare-Associated Pneumonia/epidemiology , Healthcare-Associated Pneumonia/etiology , Pneumonia/diagnosis , Pneumonia/etiology , ROC Curve , Prognosis , Retrospective Studies
3.
Anaesth Crit Care Pain Med ; 36(5): 273-277, 2017 Oct.
Article En | MEDLINE | ID: mdl-27867133

INTRODUCTION: Sedation optimizes patient comfort and ease of execution during fiber optic bronchoscopy (FOB). Our objective was to describe the safety and efficacy of remifentanil-TCI during FOB in non-intubated, hypoxaemic, thoracic surgery ICU patients. METHODS: Consecutive spontaneously breathing adults requiring FOB after thoracic surgery were included if they had hypoxaemia (PaO2/FiO2<300mmHg or need for non-invasive ventilation [NIV]) and prior FOB failure under topical anaesthesia. The remifentanil initial target was chosen at 1ng/mL brain effect-site concentration (Cet), then titrated to 0.5ng/mL Cet increments according to patient comfort and coughing. Outcomes were patient-reported pain and discomfort (Visual Analogue Scale scores), ventilatory support intensification within 24hours after bronchoscopy, and ease of FOB execution. RESULTS: Thirty-nine patients were included; all had a successful FOB. Their median PO2/FiO2 before starting FOB was 187±84mmHg and 24 patients received NIV. Median [interquartile range] pain scores were not different before and after FOB (1.0 [0.0-3.0] and 0.0 [0.0-2.0], respectively). Discomfort was reported as absent or minimal by 27 patients (69%; 95% confidence interval [95% CI], 54-81%) and as bothersome but tolerable by 12 patients (31%; 95% CI, 19-46%). Mean FiO2 returned to baseline within 2hours after FOB in 30 patients; the remaining 9 patients (23%; 95% CI, 13-38%) received ventilatory support intensification. Ease of execution was good or very good in 34 patients (87%; 95% CI, 73-94%), acceptable in 4 patients, and poor in 1 patient (persistent cough). CONCLUSION: Sedation with remifentanil-TCI during FOB with prior failure under topical anaesthesia alone was effective and acceptably safe in non-intubated hypoxaemic thoracic surgery patients.


Bronchoscopy/instrumentation , Bronchoscopy/methods , Critical Care/methods , Fiber Optic Technology , Hypnotics and Sedatives/administration & dosage , Hypoxia/therapy , Piperidines/administration & dosage , Respiratory Insufficiency/therapy , Adult , Aged , Cohort Studies , Critical Illness , Female , Humans , Hypoxia/blood , Infusions, Intravenous , Male , Middle Aged , Pain/etiology , Pain Measurement , Prospective Studies , Remifentanil , Respiratory Insufficiency/blood , Thoracic Surgical Procedures/methods
4.
Clin Transplant ; 30(9): 1152-8, 2016 09.
Article En | MEDLINE | ID: mdl-27412378

After bilateral lung and heart-lung transplantation in adults with pulmonary hypertension, hemodynamic and oxygenation deficiencies are life-threatening complications that are increasingly managed with extracorporeal life support (ECLS). The primary aim of this retrospective study was to assess 30-day and 1-year survival rates in patients managed with vs without post-operative venoarterial ECLS in 2008-2013. The secondary endpoints were the occurrence rates of nosocomial infection, bleeding, and acute renal failure. Of the 93 patients with pulmonary hypertension who received heart-lung (n=29) or bilateral lung (n=64) transplants, 28 (30%) required ECLS a median of 0 [0-6] hours after surgery completion and for a median of 3.0 [2.0-8.5] days. Compared to ECLS patients, controls had higher survival at 30 days (95.0% vs 78.5%; P=.02) and 1 year (83% vs 64%; P=.005), fewer nosocomial infections (48% vs 79%; P=.0006), and fewer bleeding events (17% vs 43%; P=.008). The need for renal replacement therapy was not different between groups (11% vs 17%; P=.54). Venoarterial ECLS is effective in treating pulmonary graft dysfunction with hemodynamic failure after heart-lung or bilateral lung. However, ECLS use was associated with higher rates of infection and bleeding.


Extracorporeal Circulation/methods , Extracorporeal Membrane Oxygenation/methods , Heart-Lung Transplantation , Hemodynamics/physiology , Hypertension, Pulmonary/surgery , Adult , Female , Follow-Up Studies , Humans , Hypertension, Pulmonary/physiopathology , Male , Retrospective Studies , Time Factors , Treatment Outcome
6.
Respir Care ; 61(3): 324-32, 2016 Mar.
Article En | MEDLINE | ID: mdl-26701366

BACKGROUND: Non-ventilator ICU-acquired pneumonia after cardiothoracic surgery is challenging to diagnose, and little is known about its impact on patient outcomes. Here, our primary objective was to compare the sensitivity and specificity of cultures of 2 types of fiberoptic bronchoscopy (FOB) specimens: endotracheal aspirates (FOB-EA) and bronchoalveolar lavage fluid (FOB-BAL). The secondary objectives were to evaluate the sensitivity and specificity of spontaneous sputum cultures and of the modified Clinical Pulmonary Infection Score (CPIS) and to describe patient outcomes. METHODS: We conducted a prospective observational study of consecutive cardiothoracic surgery subjects with suspected non-ventilator ICU-acquired pneumonia. Using FOB-BAL cultures ≥10(4) cfu/mL as the reference standard, we evaluated the accuracy of FOB-EA ≥10(5) cfu/mL and spontaneous sputum ≥10(7) cfu/mL. On the day of FOB, we determined the modified CPIS. Mortality and antibiotic treatments were recorded. RESULTS: Of 105 subjects, 57 (54.3%) received a diagnosis of non-ventilator ICU-acquired pneumonia. FOB-EA cultures had 82% (95% CI 69-91%) sensitivity and 100% (95% CI 89-100%) specificity and were significantly less sensitive than FOB-BAL cultures (P < .004). Spontaneous sputum was obtained from one-third of subjects. Spontaneous sputum cultures had 82% (95% CI 56-95%) sensitivity and 94% (95% CI 68-100%) specificity and were non-significantly less sensitive than FOB-BAL (P = .061). A modified CPIS >6 had 42% (95% CI 29-56%) sensitivity and 87% (95% CI 74-95%) specificity for non-ventilator ICU-acquired pneumonia. Antibiotic therapy was stopped in all subjects without non-ventilator ICU-acquired pneumonia, after 1.6 ± 1.2 d, without deleterious effects. CONCLUSIONS: The modified CPIS has low diagnostic accuracy for non-ventilator ICU-acquired pneumonia. FOB-EA cultures perform less well than do FOB-BAL cultures for diagnosing non-ventilator ICU-acquired pneumonia. Spontaneous sputum is valuable when FOB cannot be performed but could be obtained in only a minority of subjects. When cultures are negative, antibiotic discontinuation is safe.


Cardiac Surgical Procedures/adverse effects , Cross Infection/diagnosis , Intensive Care Units , Pneumonia/diagnosis , Postoperative Complications/microbiology , Aged , Aged, 80 and over , Anti-Bacterial Agents/therapeutic use , Bronchoalveolar Lavage Fluid/microbiology , Bronchoscopy/methods , Cross Infection/drug therapy , Cross Infection/microbiology , Female , Humans , Male , Middle Aged , Pneumonia/drug therapy , Pneumonia/microbiology , Prospective Studies , Sensitivity and Specificity , Sputum/microbiology , Trachea/microbiology
7.
Pediatr Emerg Care ; 24(3): 161-3, 2008 Mar.
Article En | MEDLINE | ID: mdl-18347494

Children involved in high-speed vehicle collision could be particularly exposed to severe injuries when adult restraints are used. We report a case where adult 3-point restraint used without booster seat was responsible for severe thoracic injury resulting in complete shoulder and clavicle dislocation, occipito-atloidal dislocation, and complete disruption of right common carotid artery in a 7-year-old boy. Misplacement of the adult shoulder harness at the base of the neck could be directly responsible for these lethal injuries, which could probably be avoided by concomitant use of a booster seat.


Infant Equipment/statistics & numerical data , Seat Belts/adverse effects , Wounds and Injuries/etiology , Wounds and Injuries/prevention & control , Accidents, Traffic , Child , Fatal Outcome , Humans , Male , Multiple Trauma
...